• 제목/요약/키워드: Pulse Correction

검색결과 141건 처리시간 0.157초

메탈 핼라이드 램프의 순시 재점등을 위한 점화기 개발 (The Ignitor Development for Momentary Restarting of Metal Halide Lamps)

  • 박종연;배수호
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.169-174
    • /
    • 2000
  • The most of metalhalide lamps is what the momentary restarting cannot be realized when the arc tube is in the hot condition. The discharge starting voltage of arc tube in the hot condition is much higher than in the cold condition in proportion to the gaseous pressure. Therefore it takes about ten minutes to restart the metal Halide lamps, that is to say, it is possible to start when the pressure and the temperature are decreased. But, if the lamp is restarted in the hot condition, we must supply the high voltage pulse with 15kV between the both electrodes of lamp. The proposed ignitor has two ignitors. If we connect each ignitor at the both sides, the high voltages of two different frequencies are generated. If so, when the one of the ignitor generates the highest voltage and the other applied to elecrodes of the lamp. In this way, we can restart the lamp with the voltage 15kV, even if the lamp is in the hot condition.

  • PDF

조합법에 의한 현장 콘크리트 강도의 비파괴 측정에 관한 연구 (A Study on the Determination of In-Situ Concrete Strength by Combined Nondestructive Testing Method)

  • 임선택;김창환;김영진;정한중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 봄 학술발표회 논문집
    • /
    • pp.114-119
    • /
    • 1992
  • The main disadvantages of destructive testing methods are the delay in obtaining test results, the relatively high cost of testing, and the lack of reproducibility in the test results. As a result, nondestructive testing methods are generally used. There are three objectives in this paper. The first is to determine the equations of the compressive strength of concrete estimated by Schmidt hammer technique, ultrasonic pulse velocity method and combined method respectively in laboratory. The second is to determine the correction factors according to the concrete age which affects most in evaluating the compressive strength of in-situ concrete. The third is to examine the applicability of the equations to evaluation of the compressive strength of in-situ concrete structures.

  • PDF

Analysis and Design of a PFC AC-DC Converter with Electrical Isolation

  • Lin, Chia-Ching;Yang, Lung-Sheng;Zheng, Ren-Jun
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.874-881
    • /
    • 2014
  • This study presents a single-phase power factor correction AC-DC converter that operates in discontinuous conduction mode. This converter uses the pulse-width modulation technique to achieve almost unity power factor and low total harmonic distortion of input current for universal input voltage $90V_{rms}$ to $264V_{rms}$) applications. The converter has a simple structure and electrical isolation. The magnetizing-inductor energy of the transformer can be recycled to the output without an additional third winding. The steady-state analysis of voltage gain and boundary operating conditions are discussed in detail. Finally, experimental results are shown to verify the performance of the proposed converter.

A Novel Soft Switching PWM·PFC AC·DC Boost Converter

  • Sahin, Yakup
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.256-262
    • /
    • 2018
  • This study introduces a novel Soft Switching (SS) Pulse Width Modulated (PWM) AC-DC boost converter. In the proposed converter, the main switch is turned on with Zero Voltage Transition (ZVT) and turned off with Zero Current Transition (ZCT). The main diode is turned on with Zero Voltage Switching (ZVS) and turned off with Zero Current Switching (ZCS). The auxiliary switch is turned on and off with ZCS. All auxiliary semiconductor devices are turned on and off with SS. There is no extra current or voltage stress on the main semiconductor devices. The majority of switching energies are transferred to the output by auxiliary transformer. Thus, the current stress of auxiliary switch is significantly reduced. Besides, the proposed converter has simple structure and ease of control due to common ground. The theoretical analysis of the proposed converter is verified by a prototype with 100 kHz switching frequency and 500 W output power. Furthermore, the efficiency of the proposed converter is 98.9% at nominal output power.

반도체 변압기용 단상 계통 연계형 인버터의 소신호 모델링과 제어기 설계 (Small-Signal Modeling and Controller Design of Grid-Connected Inverter for Solid State Transformer)

  • 김보경;이준영;;정지훈
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.40-47
    • /
    • 2017
  • In this paper, a small signal model for grid-connected inverter with unipolar pulse width modulation method is presented. Small-signal analysis allows to predict the stability and dynamics of the inverter. To regulate output voltage and to achieve power factor correction, inverter has two control loops. Loop gains are useful to identify the stability for multi-loop controlled system. Based on small-signal model, controllers are designed to improve audio susceptibility and output impedance characteristics. Proposed small-signal model and controllers are verified by PSIM simulation and experiments.

메탈헬라이드램프용 순시재점등 전자식안정기 개발 (The Development of Electric Ballast for a Instant Restart of Metalhalide Lamp)

  • 김수경;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.185-190
    • /
    • 2003
  • The most shortcoming of metalhalide lamps is what the instant restarting cannot be realized when the arc tube is in the hot condition. The discharge starting voltage of arc tube in the hot condition is much higher than in the cold condition. Therefore it takes about five minutes to restart the metalhalide lamps, that is to say, it is possible to start when the pressure and the temperature are decreased. But, if the lamp is restarted in the hot condition, we must supply the high voltage pulse with 20kV at the both sides of lamp. The proposed electronic ballast is consist of a electromagnetic interference (EMI) filter, a power factor correction (PFC) circuit, a flyback converter, a half-bridge inverter, and a high voltage igniter circuit. By this composition we can restart the lamp with the voltage 20kV, even if the lamp is in the hot condition.

  • PDF

Asymmetrical 반브리지 컨버터의 이차측 다이오드 전압스트레스저감을 위한 새로운 하이브리드 제어기법 (A new hybrid control scheme for reduction of secondary diode voltage stresses Based on interleaved PFC Asymmetrical Half Bridge Topology)

  • 박남주;이동윤;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1416-1418
    • /
    • 2005
  • This paper presents a new hybrid control method of asymmetrical half-bridge converter(AHBC) with low voltage stresses of the diodes and interleaved PFC(power factor correction). The proposed new control scheme can observe variation of secondary diodes voltage stresses by variation of duty ratio and then decide the control portions which are asymmetrical control and PFM(Pulse Frequency Modulation). Therefore, the proposed control scheme has many advantages such as a low rated voltage of the secondary diodes, low conduction loss according to the low voltage drop and wide zvs range by load variation. Through simulation results, the validity of the proposed control scheme is demonstrated.

  • PDF

에너지 저감과 업무 효율성을 위한 LED 조명환경 평가에 대한 연구 (A Study on Evaluation of LED Lighting Environments for Energy Saving and Work Effectiveness)

  • 김형선;임재현;이기선;김길희;정희창;김진호
    • 감성과학
    • /
    • 제18권2호
    • /
    • pp.45-54
    • /
    • 2015
  • 본 연구에서는 LED 광원에 대하여 재실자의 업무 효율성과 에너지 저감 효과를 알아보기 위한 실험을 실시하였다. 이를 위해 LED 광원의 특성인 펄 스 폭변조(PWM, pulse width modulation)와 조도(lux)를 제어하여 총 9가지의 다양한 조명환경을 구성하였다. LED 조명의 펄스변조 비율은 각각 R:G:B=1:1:1, R:G:B=4:1:5, R:G:B=8:7:7으로 하였으며, 조도는 각각 400 lx, 700 lx, 1000 lx 으로 설정하였다. 또한, 실내환경은 온도 $20{\sim}24^{\circ}C$, 습도 50~60%, 착의량 1 clo 로 설정하였다. 각각의 주어진 9개의 조명환경에서 업무 효율성과 에너지 소비에 대해 분석하였다. 업무 효율성 분석을 위해 오류검색수정 작업을 실시하였으며, 에너지 소비 분석을 위해 각 조명환경에서 누적 소비전력을 측정하였다. 제안한 조명환경을 통해 실험한 결과, 업무 효율성은 400 lx 보다 700 lx 이상에서 정확도 및 소요시간의 효율이 좋았으며, 소요시간의 경우 제안한 펄스변조 R:G:B=8:7:7 에서 가장 좋은 효율을 나타냈다. 또한, 각각의 조도에 대한 소비전력은 펄스변조 R:G:B=8:7:7 > RGB=1:1:1 > R:G:B=4:1:5의 순으로 낮게 나타났다. 따라서, 본 논문에서 제안한 펄스 폭 변조 효과가 업무효율성 및 에너지 저감에 영향을 미치는 것을 확인할 수 있었다.

기후변화가 극한강우와 I-D-F 분석에 미치는 영향 평가 (Impact Assessment of Climate Change on Extreme Rainfall and I-D-F Analysis)

  • 김병식;김보경;경민수;김형수
    • 한국수자원학회논문집
    • /
    • 제41권4호
    • /
    • pp.379-394
    • /
    • 2008
  • 최근 수공시설물의 설계규모를 넘어서는 극한 강우사상이 발생하여 홍수방어를 위하여 구축된 수리구조물이 파괴 되는 등 많은 홍수피해가 발생하고 있다. 따라서 극한 강우사상의 시공간적 발생 특성을 파악하고 미래의 기후변화하에서 극한강우사상이 어떻게 변화하고 설계수명기간(Design period)동안 분포 특성이 어떻게 변화할지를 이해하는 것은 매우 중요하다. 이에 본 논문에서는 미래의 기후변화가 극한 강우에 어떠한 영향을 미치는지를 평가하기 위해 기후변화 시나리오를 이용하여 미래의 극한강우의 특성 분석과 I-D-F 분석을 실시하였다. 본 연구에서는 SRES B2 온난화가스 시나리오와 YONU CGCM 를 이용하여 2030s(2031-2050)를 모의하였으며 통계학적 축소기법을 적용하여 우리나라에 위치한 기상청 산하 관측소별로 일 기상자료를 구축하였다. 또한, 이를 과거 관측 자료와 비교하여 Quantile Mapping 방법으로 편이보정을 실시하였고, 구형펄스(Modified Bartlett Lewis Rectangular Pulse, MBLRP) 모형(Onof과 Wheater, 1993; Onof 2000)과 분해기법(adjust method)을 적용하여 일 강우 시계열자료를 시 강우 시계열 자료로 변환하였으며 지속기간별 빈도별 강우량을 산정하여 I-D-F 곡선을 작성하였다. 본 논문에서는 66개 관측소 중에서 서울, 대구, 전주, 광주 지점의 결과만을 수록하였으며 그 결과 거의 모든 지점에서 현재와 비교하였을 때 지속기간이 길어질수록 강우강도가 증가함을 확인할 수 있었다.

산소포화도 측정을 위한 신호처리방법 및 계산 알고리즘 (Signl processing method and diagnostic algorithm for arterial oxygen-saturation measument)

  • 김수진;황돈연;전계진;이종연;정성규;윤길원
    • 한국광학회지
    • /
    • 제11권6호
    • /
    • pp.452-456
    • /
    • 2000
  • 동맥혈의 맥동성분에 의한 파장별 광흡수도를 측정하여 비침습적으로 산소포화도 값을 알수 있는 펄스옥시미터 장치와 신호처리방법을 개발하고 예측 알고리즘을 적용하였다. 본 장치는 광원 및 검출기로 구성된 프로브와 광신호 처리부, LED 구동회로 PC 인터페이스부로 구성되었고 데이터의 수집을 위한 구동소프트웨어 및 데이터 처리 소프트웨어를 개발하였다. 개발된 산소포화도 측정장치의 성능을 평가하는데에는 Bio-Tek 사의 펄스 옥시미터 시뮬레이터를 사용하여 다양한 알고리즘 및 데이터처리 방법들을 비교분석한 결과 맥동파형의 $In(I_p/I_v) 값을 I_{avr}$값으로 보정하는 계산 알고리즘의 방법과 진폭비보다 면적비를 이용한 계산방법이 산소포화도와의 상관관계가 우수한 것으로 나타났다. 정확한 신호 획득을 위해 개발된 맥동의 기저선 보상처리 프로그램을 inv-vivo 테스트의 데이터 처리방법에 적용하여 결과가 향상되는 것을 확인하였고 광원으로 660nm(Red)와 805nm(IR)파장을 이용한 경우보다 660nm(Red)와 940nm(IR) 파장을 이용했을 때 산소포화도와의 상관관계 및 정밀도에서 더 우수한 결과를 얻을 수 있었다.

  • PDF