• 제목/요약/키워드: Pulse Analyzer

검색결과 152건 처리시간 0.025초

응집입자와 비응집 입자의 CNC 내에서 응축성장에 관한 실험적 연구 (The growth effect of agglomerated and nonagglomerated particles in Condensation Nuclei Counter (CNC))

  • 김영원;문형우;윤진욱;안강호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.579-584
    • /
    • 2001
  • Agglomerated and nonagglomerated SiO2 particles are synthesized in furnace by the electrohydrodynamic spraying method and the vapor feeding method for the test particle generator this study. These polydispersed particles are classified with DMA to extract equal mobility particles. Then these particles are introduced into CNC (Condensation Nuclei Counter) to see the pulse height using Multi-channel Analyzer. The response characteristics of these two kinds of particles in CNCs (TSI CNC 3022 and 3025A) have been studied as a function of particle size using mono disperse particles classified by DMA. The results show that the higher drag resistance particles, so called agglomerated particles have generated a lower CNC pulse height than the spherical particles for these two different CNCs, which means the nonagglomerated particles may start to grow larger than the agglomerated particles.

  • PDF

1-3형 압전복합재료의 제조 및 펄스응답특성 (Pulse response characteristics and preparation of piezoelectic composite materials with 1-3 connectivity)

  • 김진수;김용혁;김호기;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.77-80
    • /
    • 1989
  • The aim of the study is to develope the processing technique of PZT-Polymer piezoelectric composite materials for ultrasonic transducer application such as biomedical probe and hydrophone. Piezoelectric composite of PZT and polymer with 1-3 connectivity patterns have been fabricated by dicing-filling method and extrusion forming method. In this study processing forming method. In the study processing steps by extrusion forming method in the preperation of PZT/polymer piezoelectric composites are described. The PZT powder used in the study is commercial powder which is prepared by mixing PbO, TiO$_2$ and ZrO$_2$. The binder, water and plasticizer are mixed with the PZT powder to form a slip. It is necessary to adjust the viescosity of slip according on the PZT rod diameters to be extruded. The electromechanical properties of the piezoelectric composites are characterized in terms of the thickness resonance mode. The pulse response characteristics by the ultrasonic transducer analyzer and osciloscope are evaluated.

  • PDF

25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교 (Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear)

  • 구선근;한기선;곽주식;주형준;정문규
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends

Single-poly EEPROM 의 프로그램 특성 (Programming characteristics of single-poly EEPROM)

  • 한재천;나기열;이성철;김영석
    • 전자공학회논문지A
    • /
    • 제33A권2호
    • /
    • pp.131-139
    • /
    • 1996
  • Inthis apper wa analyzed the channel-hot-electron programming characteristics of the single-poly EEPROM with different control gate and drain structures. The single-poly EEPROM uses the p$^{+}$/n$^{+}$-diffusion in the n-well as a control gate instead of the second poly-silicon. The program and erase characteristics of the single-poly EEPROM were verified using the two-dimensional device simulator, MEDICI. The single-poly EEPROM was fabricated using 0.8$\mu$m ASIC CMOS process, and its CHE programming characteristics were measured using HP4155 parameteric analyzer and HP8110 pulse gnerator. Especially we investigated the CHE programming characteristics of the single-poly EEPROM with the p$^{+}$-diffusion or n$^{+}$-diffusion in the n-well as a control gate and the LDD or single-drain structure. The single-poly EEPROM with p$^{+}$-diffusion in the n-well as a control gate and single-drain structure was programmed to about VT$\thickapprox$5V with VDS=6V, VCG=12V(1ms pulse width).th).

  • PDF

放射能 落塵의 核種檢出의 一例 (Radioactive Nuclide Identification of a Fall-Out Sample in Korea)

  • 김종국
    • 대한화학회지
    • /
    • 제6권2호
    • /
    • pp.155-157
    • /
    • 1962
  • A tiny dust found at the balcony of the Institute indicated about 8,0000 counts per minute by T.G.C.-2 Geiger-Muller tube (1.8mg/$cm^2$ window-thickness) at the distance of 2cm from the window. The main fission fragments, as identified by the present analysis, are 12.5day Ba-140 and 33.1 day Ce-141. The gamma energies were determined using $2"{\times}2"$ NaI(Tl) scintillation detector connected to RCL-256 channel pulse heigt analyzer. The beta energies were evaluated by Feather plot.

  • PDF

Laser와 PZT - Target간의 반응과 그에 따른 Plume 형성 및 입자 방출에 관한 연구 (Interaction of Laser Beam with PZT - Target and Observation of Laser - Induced Plume and Particle Ejection)

  • 이병우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권5호
    • /
    • pp.93-102
    • /
    • 1996
  • Laser-induced plume and laser-target interaction during pulsed laser deposition are demonstrated for a lead zirconate titanate (PZT). A KrF excimer laser (wavelength 248nm) was used and the laser was pulsed at 20Hz, with nominal pulse width of 20ns. The laser fluence was~$16J/cm^2,$ with 100mJ per pulse. The laser-induced plasma plume for nanosecond laser irradiation on PZT target has been investigated by optical emission spectra using an optical multichannel analyzer(OMA) and by direct observation of the plume using an ICCD high speed photography. OMA analysis showed two distinct ionic species with different expansion velocities of fast or slow according to their ionization states. The ion velocity of the front surface of the developing plume was about $10^7$cm/sec and corresponding kinetic energy was about 100eV. ICCD photograph showed another kind of even slower moving particles ejected from the target. These particles considered expelled molten parts of the target. SEM morphologies of the laser irradiated targets showed drastic melting and material removal by the laser pulse, and also showed the evidence of the molten particle ejection. The physics of the plasma(plume) formation and particle ejection has been discussed.

  • PDF

레이저 유도 플라즈마 분광분석법을 활용한 정밀 우주 자원 탐사 (Precision exploration of space resources using laser-induced breakdown spectroscopy)

  • 최수진;여재익
    • 한국항공우주학회지
    • /
    • 제39권5호
    • /
    • pp.451-457
    • /
    • 2011
  • 레이저 조사 시 발생되는 플라즈마는 물질에 따라 특정한 파장의 빛을 방출하므로, 이 빛을 수집하여 물질의 구성 성분을 정성 정량적으로 분석할 수 있다. LIBS(Laser-Induced Breakdown Spectroscopy)는 실시간에 가까운 분석과 원거리 검출이 가능하다는 점에서 우주 자원 탐사 기술로 주목받고 있다. 본 연구에서는 달 환경, 즉 고진공 하에서의 성분 분석을 위하여 double-pulse LIBS 기법을 이용하여 LIBS 신호 세기를 크게 증가시켰다. 또한 시편에 레이저가 조사되는 각도를 조절하여 임의 형상 물질의 분석을 모사하였다.

파형추적기술을 이용한 전자기기 고장진단용 회로분석기 설계 및 구현 (Design and Implementation of Circuit Analyzer for Electronics Appliance Troubleshooting and Diagnosis using Curve Tracer Technology)

  • 장재철;양규식
    • 한국정보통신학회논문지
    • /
    • 제3권2호
    • /
    • pp.273-280
    • /
    • 1999
  • 본 논문에서는 아나로그 파형분석의 파형추적기술을 이용하여 전자기기의 고장진단을 용이하게 할 수 있는 회로분석 시스템을 설계하고 구현하였다. 회로분석기는 CMOS, MOS 회로와 같은 신기술 전자부품들을 간단하게 검사할 수 있는 개선된 능력을 가지며, 내장된 펄스 구동기를 사용하여 SCR, TRIAC 그리고 Optocoupler와 같은 게이트 구동소자들을 고장진단하게 한다. 회로분석기는 측정하고자 하는 부품 및 기판에 전원을 인가하지 않고 측정하도록 하여 측정하는 중에 발생 가능성 있는 일시적인 Short로 인한 회로의 추가적인 손상을 방지하고 반도체소자의 임피던스 상태를 분석하며 시스템 또는 PCB기판의 영구적인 고장을 일으키는 누액 또는 기판손상으로 인한 문제를 완벽하게 찾아낼 수 있었다. 이상이 의심되는 부품과 정상 부품간의 상호 비교할 수 있기 때문에 부품 식별 번호가 없거나 알아보기 힘든 부품의 고장진단에 이상적으로 응용할 수 있는 방안을 제시하도록 한다.

  • PDF

통합 체질진단 시스템 개발 및 반복성 평가 (Development and Evaluation of Repeatability of the Integrated Constitutional Diagnosis System)

  • 전영주;김장웅;김재욱;배장한;김종열;김근호
    • 사상체질의학회지
    • /
    • 제24권3호
    • /
    • pp.34-41
    • /
    • 2012
  • Objectives In this study, we developed a mock-up of the system for Sasang Constitutional (SC) diagnosis. This system consists of 5 devices which are the face analyzer, the voice analyzer, the skin analyzer, the pulse analyzer, and the computer-based questionnaire. Our goal is to evaluate the repeatability of the system. Methods Each device is capable of classifying SC types. The classification probability of the integrated system for the SC types was obtained by summing the probability from each device. For evaluating the repeatability of the system, we collected data for 5 subjects, and repeated the measurement three times for each individual. The average and standard deviation were used for calculating the Coefficient of Variation. Results The results showed that the repeatability of the classification probability of the integrated system is about 8%, which implies the system is repeatable. Conclusions To increase usability of this system, it is desirable for the system to offer information on health condition of the user. The integrated constitutional diagnosis system will be upgraded to complement the convenience and to develop the diagnostic algorithm for the user's health condition.

Sn-Ag 범프의 조성과 표면 형상에 영향을 미치는 도금 인자들에 관한 연구 (The Effect of Electroplating Parameters on the Compositions and Morphologies of Sn-Ag Bumps)

  • 김종연;유진;배진수;이재호
    • 마이크로전자및패키징학회지
    • /
    • 제10권4호
    • /
    • pp.73-79
    • /
    • 2003
  • Sn-Ag 전해도금시 도금욕의 Ag 이온의 농도, 전류밀도, 펄스 주기, 첨가제등의 인자들이 솔더의 조성과 표면형상에 미치는 영향에 관하여 연구하였다. Ag 이온의 농도와 시편에 가해지는 전류밀도를 변화시킴으로써 Sn-Ag 솔더내의 Ag 조성을 조절하는 것이 가능하였고 또한 전류밀도를 증가시키면 솔더의 미세조직의 크기가 감소되는것을 관찰하였다. 펄스 인가 주기와 첨가제의 양등을 변화시키면 솔더내 Ag의 조성이 달라지고 솔더의 표면 거칠기가 감소하면서 표면 형상이 변화됨을 확인하였다. 이러한 과정을 통하여 30 $\mu\textrm{m}$의 미세피치와 15$\mu\textrm{m}$의 범프 높이를 가지는 공정 Sn-Ag 솔더 범프를 형성하였다. 도금된 솔더의 조성은 EDS와 WDS 분석을 통하여 확인하였고 표면형상은 SEM과 3D surface analyzer를 사용하여 분석하였다.

  • PDF