A Simulator for the Validation of Non-invasive Blood Pressure (NIBP) Monitoring Devices (자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발)

  • Doh, Il;Lim, Hyun Kyoon;Ahn, Bongyoung;Chee, Youngjoon;Lee, Jongshill;OH, Jae Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.111-115
    • /
    • 2017
  • Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Development of Pulse Diagnosis Hold-down Pressure Measurement System (맥진 가압 프로파일 측정 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Ryu, Hyun-Hee;Woo, Young-Jae;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1997-1998
    • /
    • 2008
  • Pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors. Although the pulse diagnosis position, Gwan is apart from Chon or Cheok by 10$\sim$20mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Chon, Gwan and Cheok. One the other hand, the education on pulse diagnosis behavior includes tantalizing problem caused by no tool for communication between trainer and trainee. On account of this situation, we tried to develop a system which can measure the hold-down pressure during a pulse diagnosis and compare the hold-down pressure profile of trainer and that of trainee. This system can be divided into three parts - pulse pressure sensing part, signal acquisition part and data storing part. A correction curve was generated by the relation between output voltages and standard weights. Using this system, 3 channel hold-down pressure profile of a oriental medical doctor were recorded three times. In the profile, three period were observed and all period included two process for searching the depth of pulsation and for classifying the pulse feeling into one or more of 28 pulse types. The maximum value of pulse profile was 1.3$kg{\cdot}f$ which was more than reported by previous chinese groups and the mean values of three channel ranged from 240$g{\cdot}f$ to 430$g{\cdot}f$. In frequency domain, each channel has some dominant frequency components - about 10Hz, 35Hz and 75Hz. In further study, we want to collect more profiles from lage number of oriental medicine doctors and hope to develop a measuring system which can measure the hold-down pressure on subject's skin directly.

  • PDF

Spray Structure and Cross-section Characteristics of Pulsed Liquid Jet Injected into a Cross-flow (횡단 유동장으로 펄스 분사된 액체 제트의 분무 구조 및 단면 분포 특성)

  • Lee, In-Chul;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Present studies of these experiments was conducted to using water, over a range of cross-flow velocities from 42 to 136 m/s, with injection frequencies from 35.7 to 166.2 Hz. In cross-flow field, main parameters of liquid jet for secondary breakup were cross-flow drag rather than pressure pulse frequency. As oscillation of the periodic pressure, liquid jet was moved up and down. Also, a bulk of liquid jet puff was detected at upper field of liquid surface. Because of pressure pulsation frequency, an inclination of SMD for the structured layer was evanescent. Cross-sectional characteristics of SMD at downstream area were non-structured distributions. The tendency of volume flux value for various frequency of pressure pulse was same distribution. And volume flux was decreased when the frequency of pressure pulse increasing.

Numerical analysis of unsteady hydrodynamic performance of pump-jet propulsor in oblique flow

  • Qiu, Chengcheng;Pan, Guang;Huang, Qiaogao;Shi, Yao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.102-115
    • /
    • 2020
  • In this study, the SST k - ω turbulence model and the sliding mesh technology based on RANS method have been adopted to simulate the exciting force and hydrodynamic of a pump-jet propulsor in different oblique inflow angle (0°, 10°, 20°, 30°) and different advance ratio (J = 0.95, J = 1.18, J = 1.58).The fully structured grid and full channel model have been adopted to improved computational accuracy. The classical skewed marine propeller E779A with different advance ratio was carried out to verify the accuracy of the numerical simulation method. The grid independence was verified. The time-domain data of pump-jet propulsor exciting force including bearing force and fluctuating pressure in different working conditions was monitored, and then which was converted to frequency domain data by fast Fourier transform (FFT). The variation laws of bearing force and fluctuating pressure in different advance ratio and different oblique flow angle has been presented. The influence of the peak of pulsation pressure in different oblique flow angle and different advance ratio has been presented. The results show that the exciting force increases with the increase of the advance ratio, the closer which is to the rotor domain and the closer to the blades tip, the greater the variation of the pulsating pressure. At the same time, the exciting force decrease with the oblique flow angle increases. And the vertical and transverse forces will change more obviously, which is the main cause of the exciting force. In addition, the pressure distribution and the velocity distribution of rotor blades tip in different oblique flow angles has been investigated.

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

Random Vibration and Harmonic Response Analyses of Upper Guide Structure Assembly to Flow Induced Loads (유체유발하중을 받는 상부안내구조물의 랜덤진동 및 조화응답해석)

  • 지용관;이영신
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.59-68
    • /
    • 2002
  • The cylindrical Upper Guide Structure assembly of the reactor intervals wish the Core Support Barrel and the Inner Barrel Assembly is subjected to flow induced loads horizontally which include random pressure fluctuation due to turbulent flow and pump pulsation pressures. The purpose of this papers is to perform random vibration and harmonic response analyses fort flow induced loads. The dynamic response characteristics due to random turbulence and pump pulsation loads were evaluated using the lumped mass beam model. Especially the model considered the annulus effects due to water gaps existing between cylindrical structures such as the Upper Guide Structure Barrel, the Core Support Barrel, and the Inner Barrel Assembly. The effect of the Inner Barrel Assembly inside the Upper Guide Structure assembly was studied. The peak dynamic responses lot each loading condition due to the addition of IBA were affected by the natural frequencies of the structures. Therefore the peak dynamic responses of the structures should be conservatively obtained from evaluation of dynamic analysis for various loading conditions.

The KMTNet View of Variable Stars : Pulsation and Rotation of the EL CVn-type Eclipsing Binary J0247-25

  • Kim, Seung-Lee;Lee, Jae Woo;Lee, Chung-Uk;Lee, Yongseok;Lee, Dong-Joo;Hong, Kyeongsoo;Cha, Sang-Mok;Kim, Dong-Jin;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.41.2-41.2
    • /
    • 2018
  • EL CVn-type eclipsing binaries are composed of a massive A-type main-sequence primary star and a hotter B-type secondary one. These are worthy of particular attention because the secondary stars are rare objects to be extremely low-mass white dwarf precursors (ELM proto-WD) with the mass of ${\leq}0.2M_{\odot}$, evolving to higher effective temperatures and higher surface gravities. A few of them were discovered to show multi-periodic pulsations in one or both components. We monitored one of these rare and interesting objects, J0247-25 (=1SWASP J024743.37-251549.2), at two KMTNet sites of SAAO in South Africa and SSO in Australia. The observations were performed with the KMTNet 1.6m telescopes and pre-science 4K CCD cameras during the system test run from July to November 2014. Using the photometric data obtained for a total of 23 nights, we constructed well-defined eclipsing light curves in B/V-bands and derived absolute parameters (mass and radius, etc.) of each binary component. After subtracting model eclipsing curves from the data, we detected seven frequencies with 33~53 cycles per day (c/d) and identified them to be Delta Sct-type pulsations originated from the A-type primary component. Five frequencies were turned out to be excited by rotational splitting of non-radial pressure modes, enabled us to investigate rotational properties. We could not detect any frequency higher than 100 c/d, implying that pulsation amplitudes of the proto-WD secondary decrease greatly.

  • PDF

Atypical Aortic Coarctation at the Level of Aortic Hiatus: Report of a case treated by bypass graft (대동맥 열공부에 발생한 비전형적 대동맥 협착증: 외과적 수술을 가한 1례)

  • 남민우;유회성;지정희
    • Journal of Chest Surgery
    • /
    • v.5 no.1
    • /
    • pp.13-18
    • /
    • 1972
  • In 1835,Schlesinger first described a case of subisthmlc lower thoracic aortic coarctation. Since Olim`s unsuccessful reconstructive surgery in 1949 and Beattie`s first successful resection with homograft replacement on such a lesion in 1951 were reported,about 20 cases of atypical aortic coarctation had been treated by definitive surgery until 1964. In Korea, only 2 cases of atypical aortic coarctation treated by bypass graft were reported until now. This is the third case-report treated by reconstructive surgery. The patient,11 year old girl who had 2 year history of headache, visual weakness, intermittent claudlcation, and general weakness, was first diagnosed of having the hypertension due to atypical coarctation by the findings of high blood pressure[170/110mmHg] at the upper extremity and weak pulsation on both femoral artery,murmur on the epigastrium, absence of aortic knob, and aorto graphy. Aortography demonstrated the isolated segmental narrowing[length 5cm, diameter 0.4cm] at the level of aortic hiatus 2cm above celiac arterial origin, the dilated right 9th, 10th, 11th intercostal arteries with multiple dimunitive collaterals and no associated abnormalities in the other arteries. Preoperatlve positive findings were strong positive mantoux test, high AST[720 units]. transient mild cardiomegaly with right lung infiltration on chest X-ray and suggestive left ventricular hypertrophy on ECG. On December 1970, through separate left thoracotomy and abdominal approach, bypass graft between descending thoracic aorta and abdominal aorta below renal artery was performed. The operation was first successful with satisfactory reduction of hypertension on the upper trunk[postoperatlve 130/80mmHg] and strong pulsation on the lower extremities[postop. O, postop. 140/100mmHg]. However,6 weeks after surgery, she expired of sudden hemoptysis and shock due to anastomotic leak within the thorax. Operative finding disclosed that the affected aorta was firm, with rich periaortic fibrosis and the outer diameter of stenotic site was not attenuated. Histopathology of the resected specimen was also compatible with primary arteritis.

  • PDF

An Experimental Determination of a Swing Check Valve Closure Time in the Main Feed Water System of a Power Plant during Shut-down Process (발전소 주급수 계통 감발 과정에서의 스윙체크밸브 닫힘 시점의 실험적 결정)

  • Suh, Jin-Sung;Kim, Won-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.8
    • /
    • pp.843-849
    • /
    • 2009
  • The reliable operation of a swing check valve in the main feed water system of a power plant is most essential for successful shout-down process. A failure to close the valve at proper time often leads to the instability of the main feed water system, or even to an emergency stop of the power plant. In reality it is a very difficult task to monitor the behavior of a swing check valve. Furthermore it is impossible to see the motion of the valve. In this work two measurements were carried out simultaneously to determine the precise valve closure time. The dynamic pressure measurements were made at the inlet and outlet regions of the swing check valve. The transient vibration of the valve housing in the direction of water flow was also measured, which enabled the measurement of the transient vibration of the valve housing near valve closure. By comparing the results produced from these measurements the precise valve closure time could be determined. By carrying out order tracking technique using the dynamic pressure signals and pump rpm signal, the complicated dynamic problems inside the main feed water system can be more easily dealt with. This measurement scheme might be implemented in a power plant on a real-time basis without much difficulty. If this could be implemented, valuable information essential for shut-down operations can readily be passed on to the main control room. The feasibility of this implementation was demonstrated by this experimental work.