$Al_2O_3-ZrO_2-SiC$ Whisker 복합재료에서의 R-curve 거동에 관한 연구 (Study on the R-curve Behaviour in $Al_2O_3-ZrO_2-SiC$ Whisker Comosite)

  • 김현하;박현;최성철
    • 한국세라믹학회지
    • /
    • 제30권9호
    • /
    • pp.731-739
    • /
    • 1993
  • R-curve measurements were performed on Al2O3(matrix)-ZrO2-SiC whisker composite and Al2O3-ZrO2, Al2O3-SiC whisker composites in the favor of comparing the effect of ZrO2 and SiC whisker, as a second phase, to Al2O3 matrix. Al2O3-SiC whisker and Al2O3-ZrO2-SiC whisker were fabricated by hot pressing at 1$700^{\circ}C$, 15MPa and Al2O3-ZrO2 by pressureless sintering at 1$600^{\circ}C$. A controlled flaw/strength technique was utilized to determine fracture resistance as a function of crack extension and R-curve behaviour was determined from the relationship which is KR=K0(Δa)m. R-curveresults were KR=6.173$\times$Δa0.031 for Al2O3-ZrO2, KR=18.796$\times$Δa0.172 for Al2O3-SiC whisker and KR=11.96$\times$Δa0.110 for Al2O3-ZrO2-SiC whisker composite. From the analysis of R-curve and expeirmental data above three composites, it is found that R-curve behaviour of Al2O3-ZrO2-SiC whisker composite was dominated initially by the strengthening effect of ZrO2 and after, some extended crack were influenced by the effect of SiC whisker. Analysis of SEM and X-ray data revealed that whisker bridging in the crack wake and whisker pull-out mechanisms were the main mechanism for the R-curve behaviour.

  • PDF

Effectiveness of Calcium Nitrite in Retarding Corrosion of Steel in Concrete

  • Abosrra, L.;Youseffi, M.;Ashour, A.F.
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권1호
    • /
    • pp.65-73
    • /
    • 2011
  • Corrosion of steel bars embedded in concrete admixed with 0%, 2% and 4% calcium nitrite (CN), having compressive strengths of 20 and 46 MPa was investigated. Reinforced concrete specimens were immersed in 3% NaCl solutions for 1, 7 and 15 days where 0.4A external current was applied to accelerate the chemical reactions. Corrosion rate was measured by retrieving electrochemical data via potentiodynamic polarization technique. Pull-out tests of reinforced concrete specimens were then conducted to assess the corroded steel-concrete bond characteristics. Experimental results showed that corrosion rate of steel bars and steel-concrete bond strength were dependent on concrete strength, amount of CN added and accelerated corrosion period. As concrete strength increased from 20 to 46 MPa, corrosion rate of embedded steel decreased. The addition of 2% CN to concrete of 20 MPa was not effective in retarding corrosion of steel at long time of exposure. However, the combination of higher strength concrete and 2% or 4% CN appear to be a desirable approach to reduce the effect of chloride-induced corrosion of steel reinforcement. After 1 day of corrosion acceleration, specimens without CN showed higher bond strength in both concrete mixes than those with CN. After 7 and 15 days of exposure, the higher concentration of CN, the higher bond strength in both concrete mixes achieved, except for the concrete specimen of 20 MPa compressive strength with 2% CN that recorded the highest deterioration in bond strength at 15 days of exposure.

가압식 그라우팅 쏘일네일 보강사면의 거동분석 (Stability Analysis for a Slope Reinforced with Pressure Grouted Soil Nails)

  • 김용민;윤여혁;이성준;정상섬
    • 한국지반공학회논문집
    • /
    • 제27권12호
    • /
    • pp.39-52
    • /
    • 2011
  • 본 연구에서는 유한요소해석 및 전단강도 감소기법을 적용하여 가압식 그라우팅 쏘일네일로 보강된 사면의 시공 단계를 고려한 사면안정 해석을 수행하였으며 무보강 자연사면 및 중력식 그라우팅 쏘일네일로 보강된 사면의 안전율과 비교함으로써 가압식 그라우팅 쏘일네일의 사면 보강효과를 분석하였다. 그 결과, 가압식 그라우팅 쏘일네일로 보강된 사면의 안전율이 중력식 그라우팅 쏘일네일로 보강된 사면에 비해 50% 이상 크게 나타났으며, 쏘일네일의 길이가 증가할수록 가압에 따른 보강효과가 우수한 것으로 나타났다. 또한 가압에 의해 사면 활동파괴영역이 확대됨에 따라 사면 전단저항 능력이 증가하는 것을 확인하였으며, 쏘일네일의 인발저항력이 사면보강에 가장 큰 영형을 미치는 것을 알 수 있었다.

표면 요철이 발달된 캐필러리 적용에 따른 Cu 와이어의 본딩 특성 (Enhancement of Cu Wire Bondability by Increasing the Surface Roughness of Capillary)

  • 이종현;김주형;강홍전;김학범;문정탁;류도형
    • 대한금속재료학회지
    • /
    • 제50권12호
    • /
    • pp.913-920
    • /
    • 2012
  • In spite of some problems in processability and bondability, Au wires in the microelectronics industry are gradually being replaced by copper wires to reduce the cost of raw material. In this article, the effects of surface roughness enhanced capillaries on thermosonic Cu wire bonding were evaluated. The roughness-enhanced zirconia toughened alumina (ZTA) capillaries were fabricated via a thermal grooving technique. As a result, the shear bond strength of first bonds (ball bonds) bonded using the roughness-enhanced capillary was enhanced by 15% as compared with that of normal bonds due to more effective plastic deformation and flow of a Cu ball. In the pull-out test of second bonds (stitch bonds), processed at two limit conditions on combinations of process parameters, the bond strength of bonds formed using the roughness-enhanced capillary also resulted in values higher by 55.5% than that of normal bonds because of the increase in the bonding area, indicating the expansion of a processing window for Cu wire bonding. These results suggest that the adoption of roughness-enhanced capillaries is a promising approach for enhancing processability and bondability in Cu wire bonding.

전방 십자 인대의 일차 봉합술 후 MRI 소견 (MRI Findings of the Repaired Anterior Cruciate Ligament)

  • 김정만;고인준;이동엽;이윤민
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.14-21
    • /
    • 2009
  • 목적: 관절경하 일차 봉합술 후 전방 십자인대의 자기 공명 영상 소견에 대하여 알아보고자 하였다. 대상 및 방법: 봉합사 견인 결찰(pull-out) 기법으로 관절경하 일차 봉합술을 시행한 17예를 대상으로 하였다. 평균 추시 기간은 21.4개월(범위: 12~60개월)이었다. 외래 방문시 신체 검사 및 KT-1000 arthrometer (MEDmetric, San Diego, CA) 측기로 안정성을 검사하였으며 수술 후 자기 공명 영상으로 추적하였다. 남아 있는 활막 소매(synovial sleeve)의 위치로 정의한 파열부의 위치에 따라 환자를 두 군으로 분류하였으며 제 1군은 파열이 대퇴골 부착 부위부터 근위 1/3 실질부 이내에 위치하는 경우, 제 2군은 파열이 근위 1/3 실질부 보다 원위에 위치하는 경우로 하였다. 수술 후 자기 공명 영상소견을 일정한 주기로 촬영하였으며 봉합된 십자인대의 주행 경로, 경계의 명확성, 두께 및 신호 강도를 3등급으로 분류하여 평가하였으며 두 군간의 차이를 분석하였다. 결과: 모든 예에서 Lachman검사와 flexion-rotation drawer 검사는 음성이었으며 Pivot-shift 검사는 1도 이하였으며 건측과 환측의 KT-1000 arthrometer 차이는 평균 1.4 mm(범위: -1.0~2.5 mm)로 측정되었다. 파열부 위치에 따른 분류로 제1군은 11예, 제 2군은 6예가 해당하였다. 자기 공명 영상 소견상 모든 예에서 전방 십자 인대의 전반적인 연속성은 유지되고 있었으나 10예(58.8%)에서 경도의 처진 주행 경로를 보였고 6예(35.3%)에서 경도의 불명확한 경계를 보였으며 8예(47.1%)에서 두께의 증가, 5예(29.4%)에서 신호 강도의 증가를 보였다. 모든 항목에서 두 군간 유의한 차이는 없었다. 한편, 시상면상 제1군의 2예(18.2%), 제 2군의 5예(83.3%), 전체 환자의 7예(41.2%)에서 대퇴골 부착 부위의 후방 변연부 실질부의 국소 결핍 소견이 관찰되었으며 이는 제2군에서 의미 있게 더 높은 빈도로 관찰되었다(p=0.035). 결론: 일차 봉합술 후 임상적으로 불안정이 없는 슬관절의 자기 공명 영상 검사 소견으로 주행 경로의 처짐, 경계의 불명확, 두께 및 신호 강도의 증가, 대퇴 부착 지점의 국소 결핍 등의 비정상 소견을 보일 수 있다. 한편 대퇴 부착부의 국소결핍 소견은 파열의 위치와 관계가 있다.

  • PDF

탄소섬유메쉬와 콘크리트의 부착거동 (Bond Behavior between Parent Concrete and Carbon Fiber Mesh)

  • 윤현도;성수용;오재혁;서수연;김태용
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.769-777
    • /
    • 2003
  • 최근 철근콘크리트(RC) 구조물의 보강기법으로 큰 인장강도와 탄성계수를 갖는 탄소섬유계열 보강재를 사용한 보강공법 개발과 이와 관련된 많은 실험 및 이론적 연구가 진행되고 있다. CFS 및 강판 보강재에 의한 보강시 야기되는 문제점을 해결하기 위하여 대체 재료로 국내에 도입된 탄소섬유메쉬(CFM)를 실 구조물의 보강공사에 적용하기 위하여 우선적으로 CFM을 이용한 보강기법 및 보강된 부재의 구조성능 규명에 대한 연구가 요구되고 있다. 본 연구에서는 탄소섬유메쉬와 콘크리트의 부착특성 규명을 위한 실험적 연구를 수행하였다. 일반적으로 탄소섬유 부착 보강공법은 보강재와 기존 부재와의 부착성능에 의해 보강효과가 지배받게 된다. 즉 부착강도가 충분한 보강효과를 기대할 수 없을 경우의 부착파괴의 가장 큰 원인으로는 계면에서의 전단강도에 기인한다고 할 수 있다. 따라서 본 연구에서는 CFM을 콘크리트에 부착하는데 있어서 정착철물(Clip)의 설치 유무, 정착철물의 정착위치, 정착철물의 설치 열 수, 부착 모르타르의 바름 유무, 부착 모르타르의 바름 두께 등의 실험 변수를 설정하고 인장전단 실험을 수행하였다. 실험결과 적절한 정착철물의 부착위치 및 정착철물 및 부착 모르타르의 부착특성을 규명할 수 있었다. 또한 본 연구에서는 범용 비선형 유한요소 해석 프로그램인 ABAQUS를 이용하여 CFM의 부착특성을 규명하기 위한 유한요소 모델 및 해석기법을 개발하였고 이를 실험결과와 비교하여 이에 대한 검증을 하였다.

마찰교반점접합한 5454-O 알루미늄합금 판재의 접합부 거시조직 및 기계적 특성에 미치는 접합인자의 영향 (Influence of Welding Parameters on Macrostructure and Mechanical Properties of Friction-Stir-Spot-Welded 5454-O Aluminum Alloy Sheets)

  • 최원호;권용재;윤성욱;강명수;임창용;서종덕;홍성태;박동환;이광학
    • Journal of Welding and Joining
    • /
    • 제29권6호
    • /
    • pp.56-64
    • /
    • 2011
  • Friction stir spot welding between 5454 aluminum alloy sheets with the different thicknesses of 1.4 and 1.0 mm was performed. In the welding process, the tool for welding was rotated ranging from 500 to 2500, and plunged to the depth of 1.8 mm under a constant tool plunge speed of 100 mm/min. And then, the rotating tool was maintained at the plunge depth during the dwell time ranging from 0 to 7 sec. The pull-out speed of the rotating tool was 100 mm/min. The increase of tool rotation speed resulted in the change of the macrostructure of friction-stir-spot-welded zone, especially the geometry of welding interface. The results of the tensile shear test showed that the total displacement and toughness of the welds were increased with the increase of the tool rotation speed, although the maximum tensile shear load was decreased. However, the change in the dwell time at the plunge depth of the tool did not produce the remarkable variation in the macrostructure and mechanical properties of the welds. In all cases, the average hardness in friction-stir-spot-welded zone was higher than that of the base metal zone. By the friction stir spot welding technique, the welds with the excellent mechanical properties than the mechanically-clinched joints could be obtained.

익산 왕궁리유적에서 후원의 위상과 의미에 대한 연구 (A Study on the Position and Meaning of the Back Garden in Wanggung-ri Site, Iksan)

  • 전용호
    • 한국전통조경학회지
    • /
    • 제34권4호
    • /
    • pp.1-13
    • /
    • 2016
  • 익산 왕궁리유적의 후원은 구릉상에 복잡한 수로체계를 통하여 정원과 연결된 구조로 동아시아 조경사에서 상당히 독특한 면모를 한 백제 조원기술(造苑技術)의 일면을 잘 보여준다. 후원은 구릉상에 입지하여 최소한의 물로 조경 효과를 높이면서도 집중 호우시 침수 피해를 줄이고, 궁성 중심 공간에 필요한 용수를 확보하기 위하여 역U자형 대형수로와 이에 연결된 수로, 곡수로 및 집수시설로 이루어진 복잡한 수로 체계를 갖추고 있다. 특히 역U자형 대형수로의 내부에서 물이 고이는 지점이나 그 가장자리에 크기나 형태가 다양한 괴석으로 장식한 조경시설도 설치되어 있다. 그리고 후원의 중심부인 구릉의 상면에는 원형 초석 시설로 둘러싼 내부에 방형 초석을 사용한 정면 4칸, 측면 4칸의 건물지가 자리하고 있다. 또한 구릉의 좌 우 사면에는 말각장방형의 석축시설로 일부분이 감싸져 있는 공간 내부에 건물도 확인되었다. 아직까지 말각장방형의 석축시설의 기능 및 역할에 대해서는 잔존 상태가 좋지 못하여 정확하게 알 수 없으나 그 내부의 건물과 관련된 시설임에는 분명하다. 이런 점에서 익산 왕궁리유적의 후원은 백제의 전통적인 조원 수법인 방지(方池) 스타일의 정원에 물을 끌어 들이거나 내보기 위한 곡지(曲池) 스타일의 수로(水路)를 함께 지니고 있다. 아울러 익산 왕궁리유적의 '정원'과 '후원'은 상호 유기적인 연결체계를 이루고 있다는 점에서 익산 왕궁성의 내부에 있는 '궁원(宮苑)'으로 보고자 한다.

주요(主要) 고농서(高農書)를 통(通)한 조선시대(朝鮮時代)의 도작기술(稻作技術) 전개(展開) 과정(過程) 연구(硏究) - VII. 중경(中耕) 제초(除草) 방식(方式)의 전환(轉換) (A Study on Transition of Rice Culture Practices During Chosun Dynasty Through Old References - VII. Transition of Weeding Technique)

  • 구자옥;이숭겸;이은웅;이홍석
    • 한국잡초학회지
    • /
    • 제12권1호
    • /
    • pp.61-69
    • /
    • 1992
  • 도전(稻田)의 서지(鋤地)(중경제초(中耕除草))법(法)은 서구(西歐)나 또는 중국(中國)과도 달리 우리 현실에 맞도록 일찍부터 체계화되고 있었으며, 가장 대표적인 서지법(鋤地法)은 배수(排水)한 후에 손제초(除草)와 서지법(鋤地法)을 순서대로 조화 있게 집행해 가는 3-4회 반복(反復)의 고도집약적(高度集約的) 농법(濃法)에 따랐다. 또한 묘종법(苗種法)으로의 전환과정(轉換過程)이나 직조파(直條播)하는 요령 자체부터 제초관리(除草管理)를 효율적으로 하려는 데 목적이 있었던 것으로 재배양식(栽培樣式)의 발전은 곧 서지(鋤地)와 직결된 관련을 가졌다. 또한 17세기(世紀)부터 고대(古代) 중국(中國)의 심경법(深耕法)(심경역누(深耕易耨)의 원리(原理) 때문), 화누법(황지(荒地)의 기숙잡초관리(旣熟雜草管理)를 효율적(效率的)으로 하기 위한 화경수누법에서 유래(由來))을 새롭게 인용하여 보급을 강조한 것은 당시의 실정(實情)에 기인하겠지만, 이로 인한 광작농(廣作農)의 실현은 곧 이들 방법과 기술적용(技術適用)의 결과라 하겠다. 18-19세기(世紀)에도 서지법(鋤地法)에 큰 차이는 없었으나 경작법(耕作法)의 변화에 맞추어 제초회수(除草回數)가 감소될 수 있었고, 특히 수도건파재배기술(水稻乾播栽培技術)은 북부조지(北部早地)에서 도작(稻作)을 하는 데 제한인자(制限因子) 역할을 하였던 물의 이용성(利用性)을 향상시킴과 동시에 잡초문제(雜草問題)를 쉽게 관리할 수 있도록 이상적인 서지방법( 鋤地方法)을 창안(創案)하여 완성시킨 경작법(耕作法)이었다. 이와 함께 조방적(粗放的) 광작농(廣作農)의 제초관리요령(除草管理要領)을 현실적으로 비평하여 반종(反種)이나 화누법의 기술(技術)들을 취사선택(取捨選擇)케 유도했던 ‘천일록(千一錄)’의 우하영(禹夏永)은 당시의 광작농기술(廣作農技術) 위에 집약농기술(集約農技術)을 접목시켜 선말(鮮末)의 '집약적광작농(集約的廣作農)'을 실현케 하고 이를 통하여 국가(國家) 농업생산력(農業生産力)을 5배(倍) 증가시키는데 크게 기여한 것으로 평가된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF