• Title/Summary/Keyword: Public Water

Search Result 1,668, Processing Time 0.035 seconds

Ab-Anbar, the Ancient Underground Water Houses of Iran

  • Yazdi, J. Tababaee;Han, Moo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1438-1441
    • /
    • 2008
  • Throughout the history, the people of Iran have battled the dryness by innovations to preserve every drop of water that lands from the rare clouds, or from a stream flowing out of distant springs. Water is precious and held with highest respect, whether stored for drinking at an Ab-Anbar, or for washing and farming at the Houz in the middle of their oasis homes and orchards, or sourced at a Qanat spring or Jooy under ground. How it is that drinking water as cold as a mountain fall is found in desert of Iran? Ab-Anbar is an ancient means of water preservation and cooling through anunderground building structure. These underground structures have been present in Khorasan and other desert provinces of Iran as public or private water storage facilities, widely used before the installation of public plumbing systems in the late 1950s. Although many of these structures are still functional, most have been protected by government for restoration or viewing by the public as historical heritage. Khorasan natural dry climate and the massive surrounding deserts have been a breeding ground for many designs of Ab-Anbars. Today the existing number of such facilities stands in the province of Khorasan. Usually these structures were built in populated areas, also there are some forms of such structures on old trade routes and roadways leading to and from populated towns. This paper considers the history of Ab-Anbars in Khorasan as well as other relevant aspects such as types, components, construction methods and materials, filling and withdrawal systems.

  • PDF

Identification of Nontuberculous Mycobacteria Existing in Public Bathroom Water by PCR-Restriction Fragment Length Polymorphism (PCR-RFLP에 의한 대중목욕탕 내 Nontuberculous Mycobacteria의 동정)

  • Choi, Seung-Gu;Song, Woon-Heung;Kang, Chee-Hwan;Cho, Kyu-Bong;Lee, Jae-Sang;Lee, Jang-Ho;Kim, Sung-Il;Jee, Soo-Il
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.40 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Thirty two of bathroom water samples from public bathroom in Seoul areas were examined using acid-fast staining, Lowenstein-Jensen (L-J) medium culture and PCR-restriction fragment length polymorphism (PCR-RFLP). In 6.25% (2/32) bathroom water samples, acid-fast bacilli were detected by AFB stain, and in 21.9% (7/32) bathroom water samples, acid fast bacilli grew on L-J media. Of them, six acid-fast bacilli were identified as Mycobacterium avium, and the other AFB as Mycobacterium szulgai by PCR-RFLP. These results are suggested that accidental nontuberculosis mycobacterial infection to a weakness person will be possible in public area.

  • PDF

Water Education for Public Servants of Developing Countries in the post COVID-19 world (포스트 코로나 시대, 개도국 공무원 대상 물 교육)

  • Kim, Saebhom;Sung, Sukkyung;Choi, Younggyun
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.248-256
    • /
    • 2021
  • After the COVID-19 pandemic, hand hygiene has become more important to prevent and reduce infection. To manage and provide water to ensure safe handwashing, water governance and the role of public servants are also getting critical. Many organizations have given their priority to capacity building of public servants. In the Strategic Plan for the ninth phase of the Intergovernmental Hydrological Programme (2022-2029), 'Water education in the Fourth Industrial Revolution' is included as a priority. In Korea, ODA in the field of water and sanitation is emphasized in Korea's 3rd Mid-term Strategy for Development Cooperation (2021-2025). Also, KOICA and various water-related organizations have been organizing water education programs for developing countries. This study presents the direction for water education for public servants in developing countries in the post COVID-19 through the education program cases of the International Centre for Water Security and Sustainable Management established by the agreement between the Korean government and UNESCO in 2017. The study suggests that water-related organizations should cooperate with each other to prevent duplication of water education contents. It also suggests that blended learning should be actively utilized for the improvement of education program effectiveness. Lastly, the study emphasizes that education demand for the water technologies related to the fourth industrial revolution and smart water management is increasing, which should be considered when water-related organizations create online content or design education programs.

Evaluation of Influent Water Quality Using Indicator Microorganisms in Lake Shiwha (지표미생물을 이용한 시화호 유입수의 수질평가)

  • Lee, Hee-Tae;Kim, Hee-Yeon;Park, Hyun-Jin;Cho, Young-Eun;Ryu, So-Young;Lee, Kyung-Jin;Jung, Jong-Sun;Ko, Gwang-Pyo
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.86-94
    • /
    • 2008
  • Lake Shiwha, an artificial lake located near metropolitan Seoul, offers a unique water environment and has been suspected to have high levels of chemical and microbiological contaminations. Lake Shiwha was originally connected to the sea but currently has four major surface water inputs from agricultural, municipal, industrial areas and in addition an occasional inflow from the sea. The objectives of this study are to investigate the relative contribution of microbial contaminants from each of the inflowing surface waters and to identify appropriate microbial indicator organisms in this unique water environment. We measured the levels of microbial contaminations in the four inflowing surface waters. A number of microbial indicator organisms including total coliform (TC), fecal coliform (FC), E. coli, Enterococci, somatic and male-specific coliphages were analyzed. Bacterial indicator microorganisms were detected and quantified by the $Colilert^{(R)},\;Enterolert^{(R)}$ kit. Surface water (50 l) was sampled by $ViroCap^{TM}\;5"$ cartridge filters and analyzed by the single agar layer method for detecting coliphages. The concentrations of TC, FC, E. coli, and Enterococci were 1543 CFU/100 ml${\sim}1.99{\times}10^6$ CFU/100 ml, 0 CFU/100 ml${\sim}202$ CFU/100ml, 0 CFU/100 ml${\sim}1.80{\sim}10^5$ CFU/100ml, 74 CFU/100 ml${\sim}3408$ CFU/100 ml, respectively. The male-specific and somatic coliphages were detected in three different inflowing surface waters. Isolated E. coli and Enterococci strains were further analyzed by 16s rDNA amplification and subsequent phylogenetic analysis from Jungwang-chun, Ansan-chun, Banwol-chun and penstock of inflowing surface water. Our results indicated that the concentrations of different fecal indicator microorganisms might not be highly correlated with each other. Multiple microbial indicator organisms should be used for monitoring microbial contamination and microbial source tracking methods.

The Comparative Analysis of Rn-222 in Water for Public Supply Pump Houses of Ulaanbaatar City

  • Oyunchimeg, Ts.;Khuukhenkhuu, G.;Norov, N,
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.51-53
    • /
    • 2003
  • The results of the measured specific activities of Rn-222 in water for public water supply pump houses (wells) of Ulaanbaatar City, Mongolia using the HP-Ge gamma-spectrometer, are described. The average of the specific radioactivies for the Rn-222 were for the station “Centre” 82.59 Bq/l, station “Combinat” 91.35 Bq/l and station “Makh” 158.25 Bq/l, respectively.

  • PDF

A study on the analysis of performance differences according to the operation method of public sewage treatment facility (공공하수처리시설 운영방식에 따른 성과 차이 분석에 관한 연구)

  • Ko, Hyunsoo;Ha, Donggyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.357-370
    • /
    • 2022
  • This study aims to analyze the differences in performance according to various operation methods (direct management, public consignment, and private agency) of public sewage treatment facilities and derive the most efficient and high level of sewage treatment services to the public based on the research results. To this end, economic performance indicators (sewage treatment cost, sewerage rate) and social performance indicators (water quality, number of civil complaints) were selected, and cross-sectional analysis and longitudinal analysis were used to verify the difference between the averages of three or more groups through one-way ANOVA. As a result of the analysis, cross-sectional analysis, there was no difference in economic performance dimension according to the operating method, but in terms of social performance dimension, it was found that there was a difference according to the operating method. In the case of water quality indicators, the results were superior to those directly managed by public consignment and private agencies in the number of civil complaints. In the longitudinal analysis examining the improvement of performance indicators, there was no significant difference by operation method in most performance indicators. In order to improve the efficiency of public services and improve the service level, various approaches suitable for the characteristics of each service are required in addition to the logic of public consignment or introduction of private agency. In the future, when local governments promote public consignment or private agency, it is necessary to understand and promote the nature of the service, the specificity of each local government, and the needs of service users.

A Comparison Study of Various Water Sources for Feasibility of Expanding the use of Groundwater in Public Water Supply of South Korea (지하수 상수원 활용의 타당성 고찰을 위한 상수도 취수원의 특성 비교 연구)

  • Cha, Eun-Jee;Hyun, Yunjung
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.4
    • /
    • pp.60-70
    • /
    • 2017
  • As water sources become more vulnerable to the effects of climate change such as drought and contamination, the diversification of water sources is important for securing water supply. This study examines the properties of five water sources for public supply, including river and river-bed water, dams, reservoirs, and groundwater, while ensuring that the quantities available from such sources are stable and the water itself is safe for use. This study also analyzes the power, chemical, repair and maintenance, and labor costs associated with each water source. The results demonstrate that groundwater has high potential as a water source because it is readily available (about $12.89billion\;m^3/yr$), but only a small portion of it is currently used. Analyses indicated that groundwater is the most efficient source of water to meet water demand below $1,000,000m^3/yr$, which covers 62.5% of water supply facilicities. With the implementation of groundwater dams, groundwater can become cost-efficient even for larger water demand. Additionally, the water source protection areas are the smallest for groundwater among the five water sources. In conclusion, the use of groundwater as an alternative water source is feasible becasue it is readily available, safe, cost-efficient, and requires the lowest amount of environmental regulations for the diversification of water supply sources.

Assessment of the Naktong River Pollution after Phenol Spillage from the Kumi Industrial Estates II, Korea (페놀오염사건 이후의 낙동강수 오염평가)

  • Kim, Doo-Hie;Jang, Bong-Ki;Hong, Sung-Chul;Moon, Hyo-Jung;Lee, Duck-Hee;Oh, Hae-Ju
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.268-281
    • /
    • 1993
  • The aquatic quality of the Naktong river after two or three months in June, 1991 with phenol spillage from a electrical factory in Kumi was investigated. The samples were collected at six sites of the Naktong river basin and Kachang and Kongsan lakes. Phenol was not detected from all water samples. Turbidity was very much increased to the down stream in the Naktong river. The BOD and COD values exceeded the 2nd grade(3mg/l) of the Korean standard quality of Environmenal Water Act at the all sampling sites of the Naktong river. Especially, the value of COD at Kaejin (12.5mg/l) was poorly classified as to the 5th grade of water class for the environmental quality standards. Organophosphorous pesticides such as parathion, malathion, fenitrothion and diazinon were investigated but not detected. Diazinon was only detected at the Ilsan bridge(1.42ppb), Okkye stream(6.95ppb), Waekwan bridge(0.32ppb), Gangjung reservior(0.13ppb), Kaejin (0.05ppb). Of the carbamates such as carbanyl, isoprocarb and cabofuran, the carbofuran was detected all sites except tap water, and Kachang and Kongsan lakes. The content of heavy metals such as Cd, Pb, Zn, Fe, Mn, Hg were not exceeding for drinking water standards at the all sampling region, but only mecury was detected from Okkye stream(0.018ppb) and Kaejin (0.09ppb). In the regions of Kachang and Kongsan lakes, the content of heavy meatals were lower than that of reservior of Naktong river.

  • PDF