• 제목/요약/키워드: Proximity-concentration

검색결과 37건 처리시간 0.027초

Seasonal and Diurnal Trend of Carbon Dioxide in a Mountainous Site in Seoul, Korea

  • Ghosh, Samik;Jung, Kweon;Jeon, Eui-Chan;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권3호
    • /
    • pp.166-176
    • /
    • 2010
  • In this research, the environmental behavior of carbon dioxide ($CO_2$) was investigated in a mountainous site in the proximity of a highly industrialized megacity, Seoul, Korea. The concentration data of $CO_2$ monitored routinely at hourly intervals at Mt. Gwan-Ak (GA), Seoul, Korea throughout 2009 were analyzed in several respects. The mean $CO_2$ value was $405{\pm}12.1$ ppm (median=403 ppm) with a range of 344 to 508 ppm (N=8548). The analysis of its seasonal trend indicated that the $CO_2$ levels peaked in the winter but reached a minimum in fall. If the short-term trend is analyzed, the $CO_2$ values generally peaked during daytime along with the presence of two shoulders; this is suspected to be indicative of strong man-made effects (e.g., traffic activities). It is seen that the general patterns of $CO_2$ distribution in this study area are highly comparable to those typically found in urban areas with strong signals of anthropogenic activities.

고에너지비소 이온 주입후 2단계 열처리시 2차결함에 대한 연구 (A Study on Secondary Defects in Silicon after 2-step Annealing of the High Energy $^{75}AS^+$ Ion Implanted Silicon)

  • 윤상현;곽계달
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.796-803
    • /
    • 1998
  • Intrinsic and proximity gettering are popular processes to get higher cumulative production yield and usually adopt multi-step annealing and high energy ion implantation, respectively. In order to test the combined processed of these, high energy \ulcornerAs\ulcorner ion implantation and 2-step annealing process were adopted. After the ion implantation followed by 2-step annealing, the wafers were cleaved and etched with Wright etchant. The morphology of cross section on samples was inspected by FESEM. The concentration profile of As was measured by SRP. The location and type of secondary defects inspected by HRTEM were dependent on the 1st annealing temperatures. That is, a line of dislocation located at $1.5mutextrm{m}$ apart from the surface at $600^{\circ}C$ lst annealing was changed to some dislocation lines or loops nearby the surface at 100$0^{\circ}C$. The density of dislocation line was reduced but the size of the defects was enlarged as the temperature increased.

  • PDF

가스렌지와 창문위치에 따른 주방 배기성능 예측 (Prediction of the ventilation performance in a kitchen with various locations of gas range and window)

  • 김경환;이재헌;박명식;이대우
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

Changes in the Microbial Distribution of Buyeo Royal Tombs: Tomb No. 1

  • Lee, Hyun Ju;Chung, Yong Jae
    • 보존과학회지
    • /
    • 제38권4호
    • /
    • pp.254-264
    • /
    • 2022
  • Built in the 6th and 7th centuries during the Baekje period, the Buyeo Royal Tombs consist of seven tombs, including Tomb No. 1, which contains murals. To preserve Tomb No. 1 from damage caused by microorganisms, periodic microbial-distribution investigations are conducted. Following such investigations in August 2016, June 2018, and November 2019, the microbes were classified according to the investigation period, location of collection, and space. This study compares and analyzes the results. The concentration of airborne microorganisms in Tomb No. 1 and the number of microbial genera identified in each space of the tomb decreased as proximity to the main room with murals diminished. During the investigation period, the genera Bacillus, Cladosporium, Penicillium, and Streptomyces were commonly identified on Tomb No. 1. The microorganisms collected from the main room walls were mostly isolated from the east and west walls where the genera Bacillus, Cupriavidus, Paenibacillus, Pseudomonas, and Streptomyces were commonly identified in three or more walls. In particular, the genus Streptomyces is a dangerous strain capable of damaging murals by penetrating into and discoloring the pigments on them. The data generated from this study may be useful for future research on microbial distribution in other domestic mural tombs and those located in North Korea and abroad.

우리나라 산림지역에서의 이산화황 농도의 시.공간적 분포 (Temporal and Spatial Distribution of Ambient Sulfur Dioxide Concentration in Forest Areas, Korea)

  • 이승우;이충화;지동훈;윤희정
    • 한국토양비료학회지
    • /
    • 제43권6호
    • /
    • pp.1035-1039
    • /
    • 2010
  • 전국 65개 산림지역 조사지를 대상으로 장기확산형 패시브샘플러를 이용하여 1993년에서 2008년까지 월별 이산화황 ($SO_2$) 농도를 측정하고 도시지역과 비교하여 산림지역에서의 이산화황 농도의 시간적 및 공간적 분포 특성을 구명하였다. 산림 내 이산화황 ($SO_2$)의 연평균 농도는 관측 시작년도부터 점차 낮아지다가 1997년 이후에는 뚜렷한 변화가 없었으며, 이는 환경부의 도시지역의 연도별 농도 변화와도 같은 경향이었다. 조사기간 동안 전체 산림지역 조사지의 연평균 이산화황 농도는 5.6 ppb로 환경부의 도시지역 평균치 (10.1 ppb)와 EC (1999)의 생태적 위해 기준치 (7.6 ppb)에 비해 낮은 수준이었다. 계절별로는 산림지역과 도시지역 모두에서 난방 연료 사용량이 많은 겨울과 봄에 농도가 높았으며 강우와 고온의 영향이 큰 여름에 낮게 나타났다. 지역별로는 다른 지역에 비해 경북과 경기지역에서 이산화황 연평균 농도가 높게 나타났다. 황산화물 배출량과 이산화황 농도 간에 유의적인 정의 상관성이 나타남에 따라 황산화물 배출원의 규모와 근접성이 대기 중 이산화황의 농도를 결정짓는 중요한 인자임을 반영하였다.

Effect of Multiple Copies of Cohesins on Cellulase and Hemicellulase Activities of Clostridium cellulovorans Mini-cellulosomes

  • Cha, Jae-Ho;Matsuoka, Satoshi;Chan, Helen;Yukawa, Hideaki;Inui, Masayuki;Doi, Roy H.
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권11호
    • /
    • pp.1782-1788
    • /
    • 2007
  • Cellulosomes in Clostridium cellulovorans are assembled by the interaction between the repeated cohesin domains of a scaffolding protein (CbpA) and the dockerin domain of enzyme components. In this study, we determined the synergistic effects on cellulosic and hemicellulosic substrates by three different recombinant mini-cellulosomes containing either endoglucanase EngB or endoxylanase XynA bound to mini-CbpA with one cohesin domain (mini-CbpAl), two cohesins (mini-CbpA12), or four cohesins (mini-CbpAl234). The assembly of EngB or XynA with mini-CbpA increased the activity against carboxymethyl cellulose, acid-swollen cellulose, Avicel, xylan, and com fiber 1.1-1.8-fold compared with that for the corresponding enzyme alone. A most distinct improvement was shown with com fiber, a natural substrate containing xylan, arabinan, and cellulose. However, there was little difference in activity between the three different mini-cellulosomes when the cellulosomal enzyme concentration was held constant regardless of the copy number of cohesins in the cellulosome. A synergistic effect was observed when the enzyme concentration was increased to be proportional to the number of cohesins in the mini-cellulosome. The highest degree of synergy was observed with mini-CbpAl234 (1.8-fold) and then mini-CbpAl2 (1.3-fold), and the lowest synergy was observed with mini-CbpAl (1.2-fold) when Avicel was used as the substrate. As the copy number of cohesin was increased, there was more synergy. These results indicate that the clustering effect (physical enzyme proximity) of the enzyme within the mini-cellulosome is one of the important factors for efficient degradation of plant cell walls.

Estimation of ambient PM10 and PM2.5 concentrations in Seoul, South Korea, using empirical models based on MODIS and Landsat 8 OLI imagery

  • Lee, Peter Sang-Hoon;Park, Jincheol;Seo, Jung-young
    • 농업과학연구
    • /
    • 제47권1호
    • /
    • pp.59-66
    • /
    • 2020
  • Particulate matter (PM) is regarded as a major threat to public health and safety in urban areas. Despite a variety of efforts to systemically monitor the distribution of PM, the limited amount of sampling sites may not provide sufficient coverage over the areas where the monitoring stations are not located in close proximity. This study examined the capacity of using remotely sensed data to estimate the PM10 and PM2.5 concentrations in Seoul, South Korea. Multiple linear regression models were developed using the multispectral band data from the Moderate-resolution imaging spectro-radiometer equipped on Terra (MODIS) and Operational Land Imager equipped on Landsat 8 (Landsat 8) and meteorological parameters. Compared to MODIS-derived models (r2 = 0.25 for PM10, r2 = 0.30 for PM2.5), the Landsat 8-derived models showed improved model reliabilities (r2 = 0.17 to 0.57 for PM10, r2 = 0.47 to 0.71 for PM2.5). Landsat 8 model-derived PM concentration and ground-truth PM measurements were cross-validated to each other to examine the capability of the models for estimating the PM concentration. The modeled PM concentrations showed a stronger correlation to PM10 (r = 0.41 to 0.75) than to PM2.5 (r = 0.14 to 0.82). Overall, the results indicate that Landsat 8-derived models were more suitable in estimating the PM concentrations. Despite the day-to-day fluctuation in the model reliability, several models showed strong correspondences of the modeled PM concentrations to the PM measurements.

해안습지 성장률의 공간적 특성에 관한 연구 - 순천만 염하구 해안습지를 사례로 - (The Spatial Characteristics of Vertical Accretion Rate in a Coastal Wetland - In case of Sunchon bay estuarine marsh, south coast of Korea -)

  • 박의준
    • 한국지역지리학회지
    • /
    • 제6권3호
    • /
    • pp.153-168
    • /
    • 2000
  • 해안습지는 육지와 해양이 만나는 점이지대에 형성된 해안퇴적지형으로, 이 중 염하구는 하천과 조류의 영향이 갯강을 통해 직접적으로 미치는 만입형 해안습지이다. 따라서 하천과 조류에 의한 퇴적작용은 염하구의 성장과 발달에 있어서 가장 중요한 프로세스이다. 해안습지는 최근 중요한 환경문제로 대두되고 있는 해수면 상승의 영향을 직접적으로 받는 지형이기 때문에, 해안습지 성장률에 관한 연구는 해안환경의 이해와 관리에 있어 중요한 자료를 제공한다. 본 연구는 순천만 염하구 해안습지를 대상으로 상이한 시간단위 속에서 진행되는 퇴적률과 조류에 의한 부유하중의 이동패턴 분석을 토대로 해안습지 성장률의 공간적 특성을 밝히고자 하였다. 조석의 일주기간의 퇴적률은 경사변환점이 염생습지보다 높은 값을 나타내었으며, 하구에서 바다로 이동하면서 퇴적률이 감소하였다. 따라서 조석의 일주기간의 퇴적률에서는 갯강과 배후 갯벌사이 경사변환점의 제방효과와 부유하중의 농도가 중요하게 작용하였다. 연간 퇴적률은 염생습지가 경사변환점보다 높은 값을 나타내어 조석의 일주기간의 퇴적률과는 다른 공간적 특성을 보였다. 그러나 하구에서 바다로 이동하면서 퇴적률이 감소하는 것은 동일하였다. 따라서 연간 퇴적률에서는 식생에 의한 부유하중 고착능력과 조류의 정체시간, 부유하중의 농도가 중요하게 작용하였다. 조류내 부유하중의 농도는 전체적으로 썰물시 영생습지를 통과한 직후가 밀물시 경사변환점을 통과한 직후보다 높은 감소율을 나타내었다. 그리고 썰물시 경사변환점을 통과한 직후의 부유하중 농도는 오히려 약간 증가하였는데, 이는 썰물에 의해 경사변환점의 퇴적물이 침식되었기 때문이다. 연구지역의 퇴적률은 시간단위와 지점에 따라 다양한 특성을 보이면서 매우 빠르게 진행되고 있다. 경사변환점은 제방효과에 의한 퇴적과 조류 및 외부요인에 의한 침식이 동시에 일어난 반면, 염생습지는 조류의 정체시간과 식생에 의한 부유하중 포획에 따라 침식보다는 퇴적이 활발하게 일어났다. 따라서 연구지역의 성장률은 갯강을 중심으로 횡적으로는 염생습지가 경사변환점보다 높고, 종적으로하는 하구지점에 가까울수록 높게 나타났다. 특히, 지난 1년간의 성장률은 다른 지역에 비해서 매우 빠른 $0.9{\sim}3.5cm/yr$로 모든 지점에서 퇴적이 침식보다 우세하게 나타났는데, 이는 연구지역이 새로운 퇴적환경으로 전이되고 있는 것과 밀접한 관계가 있는 것이다.

  • PDF

우리나라 조선산업의 공간 집중과 입지 특성 : 동남권을 중심으로 (Spatial Concentration and Locational Characteristics of the Shipbuilding Industry in the South-East Region of Korea)

  • 이종호;유태윤
    • 한국지역지리학회지
    • /
    • 제14권5호
    • /
    • pp.521-535
    • /
    • 2008
  • 조선산업은 한국을 대표하는 기간산업으로 성장해 왔으며, 지리적으로는 경남과 울산 그리고 부산을 포함하는 동남권에 절대적으로 집중되어 있어 동남권 전체가 하나의 조선산업 클러스터로 기능하고 있다. 동남권의 조선산업은 집적지의 유형 측면에서 소수의 대기업을 중심으로 이들에게 부품을 공급하는 다수의 중소기업들이 밀집되어 있는 발전된 허브-스포크형 클러스터 형태를 띠고 있다. 특히 동남권 조선산업 클러스터는 남동 해안 입지를 중심으로 집중되어 있으면서도, 해안 입지를 반드시 필요로 하지 않는 조선 기자재 부품 산업의 발달에 따라 점차 동남권 내륙지역으로 입지가 확산되는 양상을 보이고 있다. 경남지역 조선업체들을 대상으로 조사한 결과, 조선업체들은 지식, 학습, 네트워크, 혁신 등의 신 경제지리적 요소보다는 물적 인프라, 토지, 노동, 공급자와의 연계 등의 전통 경제지리적 요소를 보다 중요한 입지 요인으로 고려한 것으로 나타났다. 또한, 경남의 조선산업 입지 여건에 대해서는 집적경제에 따른 시너지 효과, 고객과의 근접성, 지역의 삶의 질 등은 상대적으로 높게 평가한 반면, 지자체 지원, 산학연 네트워크, 학습 기회, 인력 수급, 산업 용지 확보 측면에서 낮게 평가하고 있는 것으로 나타났다.

  • PDF

초음파를 이용한 수용액 속의 MTBE 분해 특성 연구 (A Study on the Degradation Properties of MTBE in Solution using Ultrasound)

  • 김희석;양인호;오재일;허남국;정상조
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.522-529
    • /
    • 2009
  • To supply safe drinking water to areas lacking in water supply and drainage system, such as rural area and military bases in proximity to Demilitarized Zone, effective method for treating organic contaminants such as MTBE is required. This study focuses on seeking optimal conditions for effective degradation of MTBE using a bath type ultrasound reactor. Effectiveness of MTBE degradation by ultrasound is dependent on the frequency, power, temperature, treatment volume, initial concentration, catalyst, etc. In this study the degradation rate of MTBE by ultrasound was proportional to power/unit volume ratio and removal is relatively more efficient for 0.1 mM than for 1 mM of MTBE solution. Efficiency of ultrasound treatment for 1 mM MTBE solution was enhanced under bath temperature of $30^{\circ}C$ compared to $4^{\circ}C$, but the temperature effect was negligible for 0.1 mM MTBE solution. Also for 0.1 mM MTBE solution, effect of catalyst such as $TiO_2$ and $Fe^0$ on treatment speed was negligible, and zeolite even increases the time taken for the degradation. Under these specific experimental conditions of this study, the most determinant factor for degradation rate of MTBE in solution was frequency and power of ultrasound. The results have shown that a continuous ultrasound reactor system can be used for small scale remediation of organically polluted groundwater, under optimal conditions.