• Title/Summary/Keyword: Proximal radius

Search Result 42, Processing Time 0.028 seconds

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Elbow Arthrodesis with bone Autograft for the Management of Gunshot Fracture in a Dog (총상 골절 개에서 자가골 이식과 주관절 고정술)

  • Lee Jong Il;Alam Md. Rafiqul;Kim Nam soo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.60-64
    • /
    • 2005
  • A 6year-old intact male hound cross dog, weighing 23 kg, was presented to the Teaching Animal Hospital, Chonbuk National University with the history of gunshot wound at the left elbow joint. Survey radiographs of the affected elbow revealed the presence of a metallic bullet caudal to the olecranon processes and comminuted fracture of the proximal radius and ulna. The first treatment strategy included removal of the bullet and fixation of the radius and ulna using separate bone plates, bone screw, K-wire and surgical wire, was failed. The second treatment strategy included olecranon osteotomy and rigid immobilization of the elbow joint with a bone plate applied to the caudal aspect of the humerus and ulna along with autogenous bone grafts collected from the 13th rib. The optimal angle of the joint following arthrodesis of this case appeared to be 130°. This resulted in improving the case but after 60 weeks the plate was bent and there was exudation from the wound. The third treatment strategy was the same with the second except for that the bone autografts were collected from the proximal metaphyses of the ipsilateral humerus. This resulted in a successful arthrodesis 6 weeks after the surgery. Elbow arthrodesis with bone autograft resulted in acceptable function, but abnormal gait remained in the dog due to mechanical interference with the movement of the joint.

Surgical Correction of an Antebrachial Deformity with Severe External Rotation in Two Dogs (심각한 외측 회전을 동반한 전완 기형의 외과적 교정 치료 2 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.328-331
    • /
    • 2011
  • Two dogs presented to the Dueckso Animal Hospital with a history of intermittent lameness of the left forelimb. On physical examination, a visible antebrachial deformity that resulted in gross external rotation of approximately $90^{\circ}$ was observed in two dogs. Medial-lateral radiographic views revealed distal ulnar subluxation, cranial bowing of the radius, radial and ulnar shortening, and external rotation of the paw. A distal ulnar ostectomy and distal radial closing wedge osteotomy were performed in two dogs. A proximal ulnar osteotomy was performed, adjacent to the elbow joint in case 1. Then, the osteotomized site was supported with an intramedullary pin. A T-plate and cortical screws were applied to the proximal and distal radial segments after derotating the distal segment internally. Postoperative radiographic view verified the correction of the angular deformity in two dogs. The follow-up was completed by physical examination 6 and 10 months after surgery respectively. There was no evidence of lameness of the left forelimb in two dogs. Gross observation of the limb revealed an apparent appropriate correction of the rotational and angular deformity in two dogs.

The Measurement of the Magnitude of Sensory Perception and Displeasure to the Vibration Stimuli applied on Forearm in upper Limb Amputees (진동자극에 대한 상지 절단자의 전완부 감각 인지 크기와 불쾌감 측정)

  • Kim, Sol-Bi;Chang, Yun-Hee;Kim, Shin-Ki;Kim, Gyoo-Suk;Mun, Mu-Sung;Bae, Tae-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.705-710
    • /
    • 2012
  • Research involving discomfort or pain related to haptic vibratory stimulation the for prosthesis users of myoelectrical hand is very lacking. Our objective of this study was to evaluate the displeasure and sensitivity of areas in forearm using vibration stimulation system between upper limb amputees and non-amputees. Twenty transradial amputees and forty non-amputees (20 youth, 20 elderly) were involved. We set up custom-made vibration stimulation system including eight actuators (4 medial parts and 4 lateral parts) and GUI-based acquisition system, to investigate changes of residual somatosensory sensibility and displeasure at proximal 25% of forearm. Eight vibration actuators were attached to the circumference of proximal 25% point of forearm at regular intervals. Sensitivity tests were used to stimulate the 120Hz and discomfort experiment was used to 37 ~ 223Hz. The subjective responses were evaluated by 10 point scale. The results showed that both groups were similar in sensitive areas. Response at around of radius was most sensitive than other areas in all subjects. Elderly group do not appear discomfort of vibrotactile; however, youth group and amputee presented discomfort of vibrotactile. Prosthesis with a vibrotactile feedback system should be developed considering the sensitivity. Furthermore, Future studies should investigate the scope of application of that principle.

Management of gunshot wounds near the elbow: experiences at a high-volume level I trauma center

  • Umar Ghilzai;Abdullah Ghali;Aaron Singh;Thomas Wesley Mitchell;Scott A. Mitchell
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.3-10
    • /
    • 2024
  • Background: Gunshot-related fractures near the elbow are challenging, and available data to guide the practitioner are lacking. This report analyzes injury patterns and treatment strategies in a case series from a high-volume urban trauma center. Methods: All periarticular gunshot fractures near the elbow treated at a level 1 trauma center from 2014 to 2018 were retrospectively reviewed. Fracture location, patient demographics, concomitant injuries, treatment modalities, and complications were analyzed. Results: Twenty-four patients were identified. All patients received prophylactic antibiotics upon admission and underwent urgent surgical debridement. Open reduction and internal fixation (ORIF) was performed with initial debridement in 22 of 24 patients. Seven patients sustained distal humerus fractures, 10 patients sustained isolated proximal ulna or proximal radius fractures, and seven had combined fracture patterns. Eleven patients presented with nerve palsy, and two had transected nerves. Two patients had vascular injury requiring repair. One patient required a temporary elbow-spanning external fixator and underwent staged debridement followed by ORIF. One patient with a grade IIIC fracture developed a deep infection that precluded ORIF. One patient required revision ORIF due to fracture displacement. Conclusions: This investigation reports on management of ballistic fractures near the elbow at a busy urban level I trauma center. Our management centered on rapid debridement, early definitive fixation, and intravenous antibiotic administration. We report on associated neurovascular injury, bone loss, and other challenges in this patient population. Level of evidence: IV.

Delayed Diagnosis of Muculocutaneous Nerve Injury Associated with a Humerus Shaft Fracture - A Case Report - (상완골 간부 골절과 동반된 진단이 지연된 근피신경 손상 - 증례 보고 -)

  • Roh, Young-Hak;Kim, Seong-Wan;Chung, Moon-Sang;Baek, Goo-Hyun;Oh, Joo-Han;Lee, Young-Ho;Gong, Hyun-Sik
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.1
    • /
    • pp.50-55
    • /
    • 2010
  • Injury of the musculocutanous nerve can be associated with a proximal humeral fracture or shoulder dislocation, and injury of the brachial plexus. However, injury of this nerve associated with a humeral shaft fracture has rarely been reported. Diagnosis of the musculocutaneous nerve injury is difficult because its sensory loss is ill-defined, and examination of elbow flexion is difficult when it is associated with fractures. We report an unusual case of musculocutaneous nerve injury in a 27 years old woman who had multiple injuries including a humerus shaft fracture, an ipsilateral radius shaft fracture, and an associated radial nerve laceration. Diagnosis of the musculocutaneous nerve injury was delayed because combined fractures of the humerus and radius prevented proper examination of the elbow motion and nerve grafting of the radial nerve delayed early elbow motion exercise. Delayed exploration of the musculocutaneous nerve 6 months after trauma showed complete rupture of the nerve at its entry into the coracobrachialis muscle and the defect was successfully managed by sural nerve graft.

  • PDF

Analysis of Greater Tuberosity from the Center of the Humeral Head: Progression to Femoralization

  • Lee, Jun-Seok;Song, Hyun Seok;Kim, Hyungsuk;Yoon, Hyung Moon;Han, Sung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.4
    • /
    • pp.216-219
    • /
    • 2019
  • Background: Progression of the tear size and erosion of the greater tuberosity (femoralization) in the supraspinatus tear makes it difficult to repair or increases the risk of a re-tear. This study examined the proximal articular surface and greater tuberosity of the humeral head in plain radiography. Methods: Two-hundred forty-seven cases, whose anteroposterior (AP) radiographs were taken correctly, were included from 288 cases, in whom the status of the supraspinatus had been confirmed by surgery. After downloading the plain AP radiograph as DICOM, the radius of the circle apposed at the superior half of the articular surface of the head, and the distance between the circle and the farthest point of the greater tuberosity ('height' of the greater tuberosity) were calculated using the software (TechHime, Korea). MRI checked the number of torn tendons and degree of muscular atrophy. Results: The following were encountered: 93 intact supraspinatus, 50 partial-thickness tears, and 104 full-thickness tears. In the analysis using the 93 intact cases, the average radius of the rotation center was 25.3 mm in male and 22.3 mm in female. The average height of the greater tuberosity from the circle with the same rotation center was 4.3 mm in male and 4.2 mm in female with no statistical significance. The correlation between the reparability of supraspinatus and height of the greater tuberosity, fatty infiltration, and muscular atrophy was confirmed. Conclusions: The height of the greater tuberosity from the circle with the same rotation center was 4.3 mm in male and 4.2 mm in female. This height was strongly correlated with muscular atrophy and fatty infiltration of the supraspinatus tendon.

Updated Surgical Techniques and Expanded Indications of Free Vascularized Fibular Graft

  • Park, Jong Woong
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.41-49
    • /
    • 2015
  • Free or pedicled vascularized fibular grafts (VFG) are useful for the reconstruction of large skeletal defects, particularly in cases of scarred or avascular beds, or in patients with combined bone and soft tissue defects. Compared to non-VFG, VEG, which contains living osteocytes and osteoblasts, maintains its own viability and serves as good osteoconductive and osteoinductive graft. Due to its many structural and biological advantages, the free fibular osteo- or osteocutaneous graft is considered the most suitable autograft for the reconstruction of long bone defects in the injured extremity. The traditional indication of VFG is the long bone and soft tissue defect, which cannot be reconstructed using a conventional operative method. Recently, the indications have been widely expanded not only for defects of midtibia, humerus, forearm, distal femur, and proximal tibia, but also for the arthrodesis of shoulder and knee joints. Because of its potential to allow further bone growth, free fibular epiphyseal transfer can be used for the hip or for distal radius defects caused by the radical resection of a tumor. The basic anatomy and surgical techniques for harvesting the VFG are well known; however, the condition of the recipient site is different in each case. Therefore, careful preoperative surgical planning should be customized in every patient. In this review, recently expanded surgical indications of VFG and surgical tips based on the author's experiences in the issues of fixation method, one or two staged reconstruction, size mismatching, overcoming the stress fracture, and arthrodesis of shoulder and knee joint using VFG are discussed with the review of literature.

Treatment of Forearm Deformity caused by Hereditary Osteochondromatosis using Free Vascularized Fibular Epiphyseal Transplantation (생비골 성장판 이식술을 이용한 선천성 다발성 골연골증에서 전완부 변형의 치료)

  • Han, Chung-Soo;Yoo, Myung-Chul;Chung, Duke-Whan;Han, Hyun-Soo;Han, Soo-Hong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.60-67
    • /
    • 1995
  • It is difficult to manage the growing deformity of forearm bone caused by hereditary osteochondromatosis in children, because deformity and discrepancy of limb length is progressive. The are many treatment methods of these problems including excisio of osteochondroma, lengthening of ulna, shortening of radius, corrective osteotomy with or without lengthening apparatus. Among many treatment methods, we tried free vascularized epiphyseal transplantation with the proximal fibular epiphysis in 3 patients of hereditary osteochondromatosis for inducement of continuous bone growth and deformity correction. The average duration of follow up was 7 years and 1 month, the shortest duration being to 4 years and 5 months and the longest 10 years and 8 months. Serial radiologic and clinical evaluation were carried out during follow up and there were satisfactory length gain, deformity correction and improvement of adjacent joint motion in 2 cases. According to our follow up evaluation, free vascularized epiphyseal transplantation is valuable procedure in forearm deformity of hereditary osteochondromatosis although it needs skillful and experienced operative technique.

  • PDF

Rapid Lymphedema Progression in Breast Cancer Patient with Previous Forearm Fracture (전완 골절 과거력이 있던 유방암 환자에서 비전형적 림프부종 발생 1례)

  • Son, Sungwook;Lee, Sangcheol;Kim, Chung Reen
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.129-132
    • /
    • 2020
  • Fracture is uncommon cause of lymphedema. The mechanism of lymphedema progression is still unknown, but disruption of the lymphatic system during and after fracture might be involved. In contrast, breast cancer surgery is a common cause of lymphedema and is usually caused by the removal of axillary lymph nodes. Sentinel node biopsy (SNB) has been adopted in early breast cancer to reduce the risk of lymphedema. Thus, the incidence of lymphedema in SNB was lowered. However, less than 10% of SNB patients are still diagnosed with lymphedema, but it is known that it took years to diagnose. Recently, we encountered atypical lymphedema occurred after breast cancer surgery with SNB. Symptoms started earlier than usual and were more severe. Interestingly, she has a history of a proximal radial fracture on the same side of SNB. We thought there could be a relationship between the acceleration of breast cancer-related lymphedema and fracture.