• 제목/요약/키워드: Proximal humeral fractures

검색결과 42건 처리시간 0.018초

Inter-rater agreement among shoulder surgeons on treatment options for proximal humeral fractures among shoulder surgeons

  • Kim, Hyojune;Song, Si-Jung;Jeon, In-Ho;Koh, Kyoung Hwan
    • Clinics in Shoulder and Elbow
    • /
    • 제25권1호
    • /
    • pp.49-56
    • /
    • 2022
  • Background: The treatment approach for proximal humeral fractures is determined by various factors, including patient age, sex, dominant arm, fracture pattern, presence of osteoporosis, preexisting arthritis, rotator cuff status, and medical comorbidities. However, there is a lack of consensus in the literature regarding the optimal treatment for displaced proximal humeral fractures. This study aimed to assess and quantify the decision-making process for either conservative or surgical treatment and the choice of surgical method among shoulder surgeons when treating proximal humeral fractures. Methods: Forty sets of true anteroposterior view, scapular Y projection view, and three-dimensional computed tomography of proximal humeral fractures were provided to 12 shoulder surgeons along with clinical information. Surveys regarding Neer classification, decisions between conservative and surgical treatments, and chosen methods were conducted twice with an interval of 2 months. The factors affecting the treatment plans were also assessed. Results: The inter-rater agreement was fair for Neer classification (kappa=0.395), moderate for the decision between conservative and surgical treatments (kappa=0.528), and substantial for the chosen method of surgical treatment (kappa=0.740). The percentage of agreement was 71.1% for Neer classification, 84.6% for the decision between conservative and surgical treatment, and 96.4% for the chosen method of surgical treatment. The fracture pattern was the most crucial factor in deciding between conservative and surgical treatments, followed by age and physical activity. Conclusions: The decision between conservative and surgical treatment for proximal humeral fractures showed good agreement, while the chosen method between osteosynthesis and arthroplasty showed substantial agreement among shoulder surgeons.

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • 제17권1호
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.

An Anterosuperior Deltoid Splitting Approach for Plate Fixation of Proximal Humeral Fractures

  • Shin, Dong-Ju;Byun, Young-Soo;Cho, Young-Ho;Park, Ki-Hong;Yoo, Hyun-Seong
    • Clinics in Shoulder and Elbow
    • /
    • 제18권1호
    • /
    • pp.2-7
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the usefulness and safety of the anterosuperior deltoid splitting approach for fixation of displaced proximal humeral fractures by analyzing the surgical outcomes. Methods: Twenty-three patients who could be followed-up for at least 8 months after the treatment of displaced proximal humeral fractures through the anterosuperior deltoid splitting approach were enrolled. We evaluated the reduction of the fractures and surgery-related complications at the last follow-up using X-ray results and clinical outcomes comprising the University of California at Los Angeles (UCLA) scoring system and the Korean Shoulder Society (KSS) score. Results: At the last follow-up of patients treated using the anterosuperior deltoid splitting approach for internal fixation of proximal humeral fractures, we found 22 cases (95.6%) of bone union, a mean UCLA score of 28.3 (range, 15 to 34) and a mean KSS score of 82.1 (range, 67 to 95). Various surgery-related complications were noted; a case of varus malunion after fracture displacement, a case of nonunion, a case of delayed union, two cases of impingement, and a case of partial axillary nerve injury, which recovered completely through the follow-up. Conclusions: Plate fixation using the anterosuperior deltoid splitting approach could be another reliable option for treating displaced proximal humeral fractures.

상완골 근위부 골절 또는 골절 및 탈구에서의 상완골 두 치환술 (Hemiarthroplasty for Fractures or Fracture-Dislocations of the Proximal Humerus)

  • 김영규;엄기석
    • Clinics in Shoulder and Elbow
    • /
    • 제3권1호
    • /
    • pp.20-25
    • /
    • 2000
  • Purpose : To evaluate functional results and study factors influencing results after humeral hemiarthroplasty for comminuted fractures of the proximal humerus. Materials and Methods: We reviewed 12 patients with average follow-up period of 23 months(12 to 42). The proximal humeral fractures consisted of one anatomical neck fracture, five three-part and six four-part fractures or fracture-dislocations. Constant score and Compito et al' evaluation system were used for clinical assessment. Statistical analysis was done with the Wilcoxon test. Results: Six cases of anatomical neck, three-part fractures or fracture-dislocations showed 61 points on the average Constant score and three unsatisfactory results on the Compito et al' evaluation; Six of four-part fractures or fracture-dislocations showed 51 points and three unsatisfactory results. There were 59(two unsatisfactory) for five non-associated dislocation and 53(four unsatistactory) for seven associated dislocation; 66(one unsatisfactory) for three under 60 years and 41(five unsatisfactory) for nine over 60 years; 67(two unsatisfactory) for seven tuberosity union and 41(four unsatisfactory) for five tuberosity non-union or resorption; 58(four unsatisfactory) for ten early operation within two weeks and 43(all unsatisfactory) for two delayed operation; and 18(unsatisfactory) for one case of a accompanied rotator cuff tear. Conclusion: We concluded that tuberosity union was important factor influencing the results. Also, we thought that age, timing of operation and accompanied rotator cuff tear could be influenced to results.

  • PDF

Short Humeral Stems in Shoulder Arthroplasty

  • Oh, Hwang Kyun;Lim, Tae Kang
    • Clinics in Shoulder and Elbow
    • /
    • 제21권2호
    • /
    • pp.105-110
    • /
    • 2018
  • Since the introduction of shoulder arthroplasty by Neer in 1974, the design of not only the glenoid component but also the humeral component used in shoulder arthroplasty has continually evolved. Changes to the design of the humeral component include a gradually disappearing proximal fin; diversified surface finishes (such as smooth, grit-blasted, and porous coating); a more contoured stem from the originally straight and cylindrical shape; and the use of press-fit uncemented fixation as opposed to cemented fixation. Despite the evolution of the humeral component for shoulder arthroplasty, however, stem-related complications are not uncommon. Examples of stem-related complications include intraoperative humeral fractures, stem loosening, periprosthetic fractures, and stress shielding. These become much more common in revision arthroplasty, where patients are associated with further complications such as surgical difficulty in extracting the humeral component, proximal metaphyseal bone loss due to stress shielding, intraoperative humeral shaft fractures, and incomplete cement removal. Physicians have made many attempts to reduce these complications by shortening the stem of the humeral component. In this review, we will discuss some of the limitations of long-stem humeral components, the feasibility of replacing them with short-stem humeral components, and the clinical outcomes associated with short-stemmed humeral components in shoulder arthroplasty.

Comparison between minimally invasive plate osteosynthesis and the deltopectoral approach with allogenous fibular bone graft in proximal humeral fractures

  • Kim, Joon Yub;Lee, Jinho;Kim, Seong-Hun
    • Clinics in Shoulder and Elbow
    • /
    • 제23권3호
    • /
    • pp.136-143
    • /
    • 2020
  • Background: The purpose of this study was to investigate the clinical differences between open reduction and plate fixation via a deltopectoral approach with allogenous fibular bone graft and a minimally invasive plate osteosynthesis (MIPO), in Neer's classification two-, threepart proximal humeral fractures. Methods: In this retrospective study, 77 patients with two-, three-part proximal humeral fractures were treated at two different institutions. Clinical and radiological evaluations were performed in 39 patients, who underwent MIPO at one institution (group A), and 38 patients, who underwent a deltopectoral approach with allo-fibular bone graft (group B) at another institution. The results between the groups were compared. Results: The MIPO technique was significantly less time consuming and caused less bleeding than the deltopectoral approach with allo-fibular bone graft (P<0.05). The duration of the fracture union was significantly reduced in group A (14.5±3.4; range, 10-22 weeks) compared to group B (16.4±4.3; range, 12-28) weeks (P<0.05). There were no statistically significant differences between the two groups when evaluating the visual analog scale and Constant scores between the two groups, 1 year postoperatively. In radiological evaluation, there was no difference in radiological outcomes between the two groups. There were no statistically significant differences in malunion between the two groups. Conclusions: The MIPO technique and deltopectoral approach with allo-fibular bone graft for two-, three-part proximal humeral fractures, show similar clinical and radiological results. However, allogenous fibular grafts require longer surgery, cause more bleeding, and result in longer fracture healing time than MIPO technique.

Preventing Varus Deformity in Senile Patients with Proximal Humerus Fractures and Poor Medial Support

  • Kim, Young-Kyu;Kang, Suk-Woong;Kim, Jin-Woo
    • Clinics in Shoulder and Elbow
    • /
    • 제19권4호
    • /
    • pp.216-222
    • /
    • 2016
  • Background: We investigated the effectiveness of fibular strut allograft augmentation of proximal humerus fractures to prevent varus deformity in patients over the age of 65 years with insufficient medial support. Methods: We analyzed the clinical and radiological outcomes of locking plate fixation with adjunct fibular strut allograft augmentation in 21 patients with proximal humeral fractures. The inclusion criteria were age (65-year-old or older); presence of severe medial comminution; inadequate medial support; and those who could participate in at least a one year follow-up. The average age was 76.4 years. We analyzed each patient's Constant score, our indicator of clinical outcome. As radiological parameters, we analyzed time-to-bone union; restoration of the medial hinge; difference between the immediately postoperative and the last follow-up humeral neck-shaft angles;; and anatomical reduction status, which was assessed using the Paavolainen method. Results: A successful bone union was achieved in all patients at an average of 11.4 weeks. We found that the average Constant score was 74.2, showing a satisfactory outcome. The average difference in the humeral neck-shaft angles between the immediately postoperative time-point and at the final follow-up was $3.09^{\circ}$. According to the Paavolainen method, the anatomical reduction was rated excellent. The medial hinge was restored in 14 of 21 patients. Although we did not find evidence for osteonecrosis, we found that a single patient had a postoperative complication of screw cut-out. Conclusions: Fibular strut allografting as an adjunct treatment of proximal humeral fractures may reduce varus deformity in patients with severe medial comminution.

Efficacy of Additive Trans-cuff Augmentation Sutures for Proximal Humeral Fractures Stabilized by Locking Plates in Elderly Patients

  • Cho, Nam Su;Shim, Hee Seok;Lee, Sang Hyeon;Jeon, Jong Wook;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.68-74
    • /
    • 2015
  • Background: The purpose of our study was to evaluate the functional and radiologic outcomes of additive augmentation sutures through rotator cuff for proximal humeral fractures stabilized locking plate in elderly patients. Methods: We enrolled 74 patients over the age of 60 years who received internal fixation using locking plates for proximal humeral fractures. Of these, 50 patients had additive augmentation sutures through rotator cuff. The mean age at the time of surgery was 72.1 years (range, 60-89 years), and the mean follow-up period was 17.5 months (range, 12-62 months). The humeral neck-shaft angle and humeral head height were used as radiological markers to assess the effect of additive augmentation sutures through rotator cuff. We allocated the patients who received additive augmentation sutures into group A and those who did not into group B. Results: At the final follow-up, the mean Korean Showlder Society score and Constant scores were $88.96{\pm}12.1$ and $86.6{\pm}11.9$, respectively, in group A and $86.21{\pm}11.8$ and $85.3{\pm}11.7$, respectively, in group B (p=0.368, 0.271). At the final follow-up, the mean loss in humeral neck-shaft angle from the time of immediate postoperative measurement was $1.6^{\circ}$ in group A and $4.8^{\circ}$ in group B, whereas the mean loss in humeral head height was 0.82 mm in group A and 0.52 mm in group B (p=0.029, 0.178). Conclusions: The surgical outcomes of internal fixation using locking plates for proximal humeral fractures were clinically and radiologically good in elderly patients over the age of 60 years without any observable complications. Further, the loss of humeral head shaft angle at the final follow-up from its initial postoperative measurement was significantly smaller in patients who received an additive augmentation suture than in those who did not. Thus, we conclude that augmentation sutures are a beneficial option for elderly patients that clinicians can consider at the time of surgical decision making.

Minimally Invasive Percutaneous Plate Osteosynthesis via a Deltoid-splitting Approach with Strut Allograft for the Treatment of Displaced 3- or 4-part Proximal Humeral Fractures

  • Noh, Young-Min;Kim, Dong Ryul;Kim, Chul-Hong;Lee, Seung Yup
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.220-226
    • /
    • 2018
  • Background: This study introduces a surgical technique with good clinical outcome useful in the treatment of osteoporotic displaced 3- or 4-part proximal humeral fractures. Methods: From May 2014 to February 2016, 16 patients with displaced 3- or 4-part proximal humeral fractures were treated by application of a locking plate with an endosteal strut allograft via a deltoid splitting approach with a minimum follow-up of 12 months. The allograft was inserted through a fractured gap of the greater tuberosity to support the humeral head and then fixed by a locking plate with meticulous soft tissue dissection to protect the axillary nerve. Surgical outcomes were evaluated by the American Shoulder and Elbow Surgeons (ASES) and visual analogue scale (VAS) scores, radiological imaging, and clinical examination. Fixation failure on radiographs was defined as a >$5^{\circ}$ loss of neck shaft angle (NSA) compared to that on an immediate postoperative radiograph. Avascular necrosis (AVN) of the humeral head was also evaluated. Results: In all cases, complete union was achieved. The ASES and VAS scores were improved to $85.4{\pm}2.1$ and $3.2{\pm}1.3$, respectively. Twelve patients (75.0%) had greater than a $5^{\circ}$ change in NSA; the average NSA change was $3.8^{\circ}$. Five patients (31.3%) had unsatisfactory ranges of motion exhibiting a <$100^{\circ}$ active forward flexion. No axillary nerve injuries or AVN were observed at the last follow-up. One patient was converted to reverse total arthroplasty due to severe pain and functional deficit. Conclusions: Minimally invasive fixation via a locking compression plate and an endosteal fibula strut allograft in Neer classification 3-or 4-part fractures with severe osteoporosis in elderly patients can achieve good clinical results.

근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교 (Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures)

  • 김재화;이윤석;안태근;최정필
    • Clinics in Shoulder and Elbow
    • /
    • 제11권2호
    • /
    • pp.143-149
    • /
    • 2008
  • 목적: 근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과를 비교 분석하고자 하였다. 대상 및 방법: 2003년부터 2007년 까지 본원에서 근위 상완골 골절로 입원하였던 87명의 환자중 금속판 고정술을 시행 받았던 환자 20명을 대상으로 하였으며 20명의 환자는 잠김 압박 금속판 고정을 시행하였던 환자 10명, 비잠김 금속판 고정을 시행하였던 환자 10명의 두 군으로 나뉘었다. 각각의 환자군은 수술 직후와 수술 후 6개월 뒤 방사선 사진상 상완골의 경간각, 골유합까지 소요된 시간, 합병증의 빈도 그리고 마지막 추시 당시의 Constant score를 측정하여 서로 비교 분석 하였다. 결과: 상완골의 경각간 및 골유합, Constant score에 대해서 두 군은 유의한 차이를 보이지 않았으나 비잠김 금속판을 사용한 군에서 나사 풀림 현상이 3례에서 발견되었다. 결론: 추시 결과상 잠김 압박 금속판의 사용이 비잠김 금속판에 비하여 임상적, 방사선학적으로 유의한 차이는 없었으나 근위 상완골 골절의 치료에서 나사 풀림 현상 등의 합병증이 적은 잠김 압박 금속판을 사용하는 것이 더 효과적일 것으로 사료된다.