• Title/Summary/Keyword: Proximal fracture

Search Result 255, Processing Time 0.023 seconds

Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density (골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성)

  • Hwang, Kyo Seung;Kim, Yoon Mi;Park, Jong Chan;Choi, Min Joo;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.502-508
    • /
    • 2012
  • Quantitative ultrasound technologies for osteoporosis diagnosis measure ultrasonic parameters such as speed of sound(SOS) and normalized broadband ultrasound attenuation(nBUA) in the calcaneus (heel bone). In the present study, the dependences of SOS and nBUA on bone mineral density in the proximal femur with high risk of fracture were investigated by using 20 trabecular bone samples extracted from bovine femurs. SOS and nBUA in the femoral trabecular bone samples were measured by using a transverse transmission method with one matched pair of ultrasonic transducers with a center frequency of 1.0 MHz. SOS and nBUA measured in the 20 trabecular bone samples exhibited high Pearson's correlation coefficients (r) of r = 0.83 and 0.72 with apparent bone density, respectively. The multiple regression analysis with SOS and nBUA as independent variables and apparent bone density as a dependent variable showed that the correlation coefficient r = 0.85 of the multiple linear regression model was higher than those of the simple linear regression model with either parameter SOS or nBUA as an independent variable. These high linear correlations between the ultrasonic parameters and the bone density suggest that the ultrasonic parameters measured in the femur can be useful for predicting the femoral bone mineral density.

Evaluation of the Femoral Stem Implant in Canine Total Hip Arthroplasty: A Cadaver Study

  • Cho, Hyoung Sun;Kwon, Yonghwan;Kim, Young-Ung;Kang, Jin-Su;Lee, Kichang;Kim, Namsoo;Kim, Min Su
    • Journal of Veterinary Clinics
    • /
    • v.36 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • Total hip arthroplasty (THA) is a successful surgical treatment for both patients with chronical lameness and dogs who are nonresponsive to medical treatments, providing excellent joint function for returning dogs to the normal gait in 80% to 98% of hip dysplasia (HD) patients. The THA surgical implant system manufactured by BioMedtrix and Kyon are today widely accepted. When comparing the BioMedtrix biological fixation (BFX) system to the BioMedtrix cemented fixation (CFX) system, the many advantages of BFX, which include longer potential implant life, decreased risk of postoperative or later infection, and better implant stability, become evident. However, BFX implies a greater risk of femoral fracture during reaming and requires a more precise surgical technique to achieve good implant fit, given the press-fit nature of cementless THA. The purposes of this study are to both describe the mistakes and complications during stem implantation for beginner surgeons with both the BFX and the CFX systems and to document the initial result of 12 implantations in canine cadavers. Given the detailed evaluations of 3 specialists, who are Diplomate American College of Veterinary Surgeons (DACVS), only 3 of 11 stems were appropriately sized. Specifically, 6 stems were anteverted rather than being retroverted; further, although 7 stems were coaxial with the femoral long axis in the frontal plane, the other stems were in the varus at the frontal plane, with the proximal medial stem adjacent to the medial femoral cortex. Moderate angulation from the cranial to the caudal directions was found in 4 cases in the sagittal plane. Additionally, 1 case of femoral fissure and 1 case of perforated femoral cortex were reported. It is not easy for surgeons performing cementless THA for the first time to achieve a good result, even though they completed an educational course about it and given that catastrophic complications often occurred during early surgical clinical cases. Therefore, ex-vivo studies are sincerely required to get an expertise by rehearsing the preparation of the femoral envelop in isolated bones. Further studies should be conducted to achieve both highly accurate implant size and correct orientation during the preoperative planning. Additionally, surgeons' learning curve should be examined in future investigations.

Complications of PCL Reconstruction using Tibial Inlay Technique (경골 Inlay 방법을 이용한 후방 십자 인대 재건술의 합병증)

  • Kim Myung-Ho;Park Hee-Gon;Yoo Moon-Jib;Byun Woo-Sup;Shim Shang-Ho
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.2
    • /
    • pp.128-133
    • /
    • 2004
  • Purpose: This study was planned to evaluate complications? of posterior cruciate ligament (PCL) reconstruction with tibial inlay technique using autogenous bone-patellar tendon-bone graft. Materials and Methods: From September 1994 to January 2004, we analyzed surgical complications in fifty-seven patients with fifty-eight cases who underwent PCL reconstruction. Fifty of them were male and seven female. The mean age of the patients was 35(15$\~$73). Twenty eight cases of injury were isolated PCL, while thirty cases had associated injury of knee. The causes of injury were thirty-nine cases of traffic accident, seven sport injuries, seven fall down injuries, and five of others. The follow-up study was done at 4 weeks, 3 months,6 months and 1 year after surgery. KT-2000 arthrometer and posterior stress X-ray were used to examine the stability of the knee joint and the Lysholm Knee Score and a variety of clinical complications were evaluated. Results: Although the mean score of the preoperative Lysholm Knee Score was 43.2, the postoperative score was increased to 87.9. The preoperative mean value of knee stability using KT-2000 arthrometer was 8.75 mm(6.2$\~$14.3 mm) but the postoperative mean was 3.41 mm(2.1$\~$10.6 mm). The intraoperative complications were: one case of popliteal artery injury with compartment syndrome, one case of patellar fracture, two cases of 20$^{\circ}$ flexion loss, and two cases of anterior cortical penetration of the screw through proximal tibia during screw fixation. The postoperative complications were: eleven cases of knee instability, one case of patellar fracture, five cases of extension loss, thirteen cases of flexion loss, twenty-one cases of around knee pain and eight cases of kneeling pain. Conclusion: After PCL reconstruction with tibial inlay technique using autogenous bone-patella tendon-bone graft, complications were observed in this study. Careful attention during and after the operation, as well as rehabilitation must be required.

  • PDF

Outcome of Tumor Prosthetic Reconstruction in Osteosarcoma Patient (골육종 환자에서 종양 대치물을 이용한 재건술의 치료결과)

  • Kim, Jae-Do;Kim, Cheung-Kue;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.79-86
    • /
    • 2011
  • Purpose: Modular tumor prosthesis is the most popular recontructive modality after resection of malignat tumor in extremity. Complications and survival of tumor prosthesis reconstruction are well-known. however, reports on the long-term outcome of tumor prosthesis in osteosarcoma patientss are scarece. Materials and Methods: In 158 cases as diagnosed as osteosarcoma from feburary 1989 to December 2006 in a single cancer center. We retrospectively reviewd 48 osteosarcoma patients who under went tumor prosthetic reconstruction. Mean follow up preiod was 75.6 months (range; 60 to 179 months). There were 28 males, 20 females and mean age was 22.4 years (range; 11-71). Pathologic subtypes were conventional central osteosarcoma in 46 cases and periosteal in 2 cases. The location of the tumor was proximal tibia (26 cases), distal femor (20 cases), femor diaphysis (1 case), and tibia diaphysis (1 case). In 41 cases built-up-type tumor prosthesis have been used and 7 cases expansion-type tumor prosthesis have been used. We used Musculoskeletal tumor society (MSTS) grading system to asses post operation function, and we analyzed survival rate of patient and tumor prosthesis and complication. Results: The overall survival rate was 77.7% and disease free survival rate was 68.9%. The survival rate of tumor prosthesis was 73%, in last follow up tumor prosthesis has been removed in 12 cases. All of them, 17 complications occurred, which included infection in 16 cases, Periprosthetic Fracture and Loosening of tumor prosthesis in 4 cases, articular instability in 4 cases. MSTS functional score was 74.1% in post operation. Conclusion: In long term follow up result, Primary tumor prosthesis -a reconstruction method after a wide extensional resecion of a bone tumor- can be a effective treatment method in asepect of survival rate, functional assesment and complication.

Midterm Results of Bipolar Hemiarthroplasty for Unstable Intertrochanteric Femoral Fractures Using a Type 3C Cementless Stem (불안정성 대퇴골 전자간 골절에 3C형 무시멘트 대퇴 스템을 이용한 고관절 반치환술의 중기 결과)

  • Chung, Woochull;Cho, Hong Man;Kim, Sun do;Park, Jiyeon;Kwon, Kihyun;Lee, Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • Purpose: Bipolar hemiarthroplasty is used as an alternative to open reduction and internal fixation for unstable intertrochanteric fractures in elderly patients. Recent advances in medical systems and technologies have resulted in increased survival rates after intertrochanteric fractures of the femur, requiring selection of the appropriate femoral stems considering the mid- to long-term duration of survival. Hemiarthroplasty was performed for unstable intertrochanteric fractures using a double tapered quadrilateral femoral stem (C2 stem), and the clinical and radiological results were evaluated as a five-year follow-up post-surgery. Materials and Methods: From January 2004 to December 2013, 43 patients (43 hips) who underwent hemiarthroplasty with a C2 stem were enrolled in this study. Their mean age was 78.6 years (range, 70-84 years), and the mean follow-up period was 85.4 months (range, 60-96 months). During the follow-up period, clinical parameters, such as the changes in pain, walking ability, and functional status, were examined. Radiologically, changes in the proximal femur, such as osteoporosis and bone resorption of cortical bone, were noted. Complications that occurred during the follow-up period, such as dislocation and prosthetic features, were also reviewed. Results: Initially, the pain was relieved postoperatively, but it increased four years after surgery. The walking ability was reduced by two steps in nine patients after 60 months, and the Harris hip score was reduced significantly postoperatively after two to three years. Radiologically, cortical osteoporosis occurred in 14 patients. Five patients developed cortical bone resorption. Four of them showed nonunion of the trochanteric fracture fragments, and three of them suffered reverse oblique fractures. Conclusion: Careful selection considering the general health condition and remaining lifespan of the patient would be necessary for primary hip hemiarthroplasty using a 3C type cementless femoral stem for unstable intertrochanteric fractures in elderly patients with osteoporosis.