• Title/Summary/Keyword: Proximal fracture

Search Result 252, Processing Time 0.025 seconds

Treatment of Tibial Fractures by Interlocking Intramedullary Nailing (Interlocking Intramedullary Nail을 이용한 경골 골절의 치료)

  • Jung, Kwang-Yeoung;Lee, Dong-Chul;Suh, Jae-Sung;Kim, Se-Dong
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.388-399
    • /
    • 1993
  • The adequate treatment of tibia fracture is one of the most difficult due to severe commiuntion, open wound, delayed union, angulation deformity and infection. We treated 38 fractures of the tibia by Interlocking intramedullary nail from Feb. 1983 to Mar. 1993, 35 cases of the tibia fracture were fresh, 13 cases of fracture were open. The other 3 cases were delayed union and nonunion. The Mean follow-up was 14.0 months. The results were as followings. 1. Of the 38 fractures, 37 fractures united and the mean union time was 18.7 weeks. 2. Interlocking intramedullary nail could be used to the majority of fractures of the proximal & distal tibia shaft fractures. 3. The Interlocking nail had rigid rotational stability and was appropriate for the treatment in severe unstable fractures, commninution and open with bone loss. 4. Delayed union or nonunion was a good indication for intramedullary nailling. 5. The major complication were valgus deformity of 2 cases, varus deformity of 1 case, 1 case deep infection. 6. Interlocking intramedullary nailing provided rigid fixation of fracture and then made early joint motion exercise and ambulation.

  • PDF

Comparison of 4 mg dexamethasone versus 8 mg dexamethasone as an adjuvant to levobupivacaine in fascia iliaca block-a prospective study

  • Acharya, Ranjita;Sriramka, Bhavna;Panigrahi, Sandeep
    • The Korean Journal of Pain
    • /
    • v.31 no.4
    • /
    • pp.261-267
    • /
    • 2018
  • Background: To compare the effects of adding two different doses of dexamethasone on the duration and quality of the fascia iliaca block in patients undergoing proximal femoral fracture surgery. Methods: A total of 60 patients (age 18-70 years) undergoing proximal femoral nailing surgery under spinal anesthesia were given fascia iliaca block after random assignment to one of the two groups: Group H received an injection of levobupivacaine (0.5%) 28 ml with 2 ml (8 mg) dexamethasone, and Group L received an injection of levobupivacaine (0.5%) 28 ml with dexamethasone 1 ml (4 mg) with 1 ml normal saline. Assessment of the duration of analgesia and the total tramadol requirement over 48 hours were noted after a successful block. Results: The duration of analgesia was found to be significantly longer in Group H ($17.02{\pm}0.45h$) than in the Group L patients ($14.29{\pm}0.45h$) with a p-value of 0.000. Postoperative analgesic requirement (amount of tramadol in mg) was significantly higher in Group L (Q2: 200.0; IQR: 100.0, 200.0) as compared to Group H (Q2: 100.0; IQR: 100.0, 200.0) with a p-value of 0.034. No patient showed any sign of neurotoxicity. Conclusions: Dexamethasone, in a dose of 8 mg, is superior to 4 mg when used as an adjuvant with levobupivacaine in the FIB. Though both prolonged analgesia and were effective in reducing oral/intravenous analgesics, 8 mg dexamethasone can be recommended as a more efficacious adjuvant to local anesthetics in the FIB.

Influence of the amount of tooth surface preparation on the shear bond strength of zirconia cantilever single-retainer resin-bonded fixed partial denture

  • Sillam, Charles-Ellie;Cetik, Sibel;Ha, Thai Hoang;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.286-290
    • /
    • 2018
  • PURPOSE. Conventional resin-bonded fixed partial dentures (RBFPDs) are usually made with a two-retainer design. Unlike conventional RBFPDs, cantilever resin-bonded fixed partial dentures (Cantilever RBFPDs) are, for their part, made with a single-retainer design. The aim of this study was to compare the effect of tooth surface preparation on the bond strength of zirconia cantilever single-retainer RBFPDs. The objective is to evaluate the shear bond strength of these single-retainer RBFPDs bonded on 3 different amount of tooth surface preparation. MATERIALS AND METHODS. Thirty extracted bovine incisors were categorized to 3 groups (n=10), with different amounts of tooth surface preparations. Teeth were restored with single-retainer RBFPDs with different retainer surfaces: large retainer of $32mm^2$; medium retainer of $22mm^2$; no retainer and only a proximal connecting box of $12mm^2$. All RBFPDs were made of zirconia and were bonded using an adhesive system without adhesive capacity. Shear forces were applied to these restorations until debonding. RESULTS. Mean shear bond strength values for the groups I, II, and II were $2.39{\pm}0.53MPa$, $3.13{\pm}0.69MPa$, and $5.40{\pm}0.96MPa$, respectively. Statistical analyses were performed using a one-way ANOVA test with Bonferroni post-hoc test, at a significance level of 0.001. Failure modes were observed and showed a 100% adhesive fracture. CONCLUSION. It can be concluded that the preparation of large tooth surface preparation might be irrelevant. For zirconia single-retainer RBFPD, only the preparation of a proximal connecting box seems to be a reliable and minimally invasive approach. The differences are statistically significant.

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Comparison Study of Different Approach (Deltoid Splitting Approach and Delto-pectoral Interval Approach) for Proximal Humeral Fractures (근위 상완골 골절의 수술적 치료에서 삼각근 분할 도달법과 삼각 대흉간 도달법의 임상적, 방사선학적 추시 결과 비교)

  • Kim, Seung-Hee;Dan, Jinmyoung;Kim, Byoung-Kook;Lee, Yun-Seok;Kim, Hyoeng-Jung;Ryu, Keun-Jeong;Lee, Jin-Hyun;Kim, Jae-Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2013
  • Purpose: A comparison of the radiographic and the clinical outcomes between two different surgical approaches-Deltoid splitting and Delto-pectoral interval-on the proximal humerus fractures treated by locking compressive plate (LCP), is done. Materials and Methods: Medical records and pre- and postoperative radiographs were reviewed retrospectively for 75 adult patients who underwent surgical fixations with locking compressive plates from May 2005 to December 2011. Patients were divided into two groups according to the surgical methods. Differences in the neck-shaft angle between immediate postoperative period and final follow-up were compared between the two groups. Differences in constant score and Korean shoulder score (KSS) between affected arms and contralateral arms at final follow-up were also compared. Results: The differences in the neck-shaft angle between immediate postoperative period and at final follow-up was 12.04 degrees on average in Deltoid splitting approach and 10.20 degrees in Delto-pectoral interval approach, which was not statistically significant. Differences in constant score/KSS between the affected arm and the contralateral arm were 13.78/22.74 points in deltoid-splitting approach on average and 19.41/31.13 points in Delto-pectoral interval approach, showing that deltoid-splitting approach is significantly superior. Conclusion: Deltoid-splitting approach showed better functional outcomes in the fracture reduction and internal fixation using LCP for the treatment of unstable proximal humerus fractures.

Surgical Treatment for Pathologic Fracture of Skeletal Metastatic Lesion of the Proximal Femur: Comparison of Clinical Outcomes for Prosthetic Joint Replacement and Osteosynthetic Fixation (근위 대퇴골에 발생한 전이성 골종양의 병적 골절의 수술적 치료: 종양대치 인공관절 치환술과 골절 고정술의 치료 성적 비교)

  • Shin, Duk-Seop;Kim, Ui-Sik;Kwak, Hae-Jun;Ko, Young-Jin
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.44-50
    • /
    • 2011
  • Purpose: To compare clinical outcomes of the tumor prosthetic replacement and osteosynthetic fixation for pathologic fracture of skeletal metastatic lesion of the proximal femur. Materials and Methods: From 1994 May to 2009 May, medical records of 22 patients who underwent tumor prosthetic replacement with tumor resection (group 1) and 15 others (16 hips) who underwent osteosynthetic fixation without tumor resection (group 2) were reviewed. The mean age of overall patients were 59 (group 1) and 60 (group 2). Mean follow up periods were 23 and 11 months. The oncological and functional results were evaluated with Kaplan-Meier methods and Musculoskeletal Tumor Society (MSTS) scoring system, 1993. The statistical evaluation was assessed with Log rank test and t-test. Results: The mean survival periods were 24 months in group 1 and 11months in group 2. The 1 year survival rates were 86% in group 1 and 50 % in group 2, and 2 year survival rates were 29.7% in group 1 and 9.4% in group 2. The mean MSTS functional score were 26.4 (19-30), 87.9% in group 1 and 15.3 (10-23), 51.0% in group 2. Conclusion: The results of tumor resection and prosthetic replacement in selected cases was better than osteosynthetic fixation without tumor resection for metastatic bone tumors around proximal femur in oncological and functional aspects.

Functional and Radiological Results of Intermediate-term Follow Up in $MUTARS^{(R)}$ Tumor Endoprostheses ($MUTARS^{(R)}$ 종양 대치물을 이용한 사지 구제술의 기능적 및 방사선학적 중기 추시 결과)

  • Kang, Dong-Joon;Kim, Jeung-Il;Oh, Jong-Seok;Moon, Tae-Yong;Lee, In-Sook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • Purpose: This study was designed to verify intermediate-term functional and radiological results of limb salvage operation using endoprosthetic replacement system ($MUTARS^{(R)}$) used in patients with a malignant bone tumor. Materials and Methods: Thirty one cases which used $MUTARS^{(R)}$ tumor prosthesis were reviewed. The mean age of the patients was 49.2 years and the mean follow up was 39.8 months. We retrospectively reviewed complications, and evaluated functionally and radiologically by Enneking functional score, ISOLS radiological implants evaluation system at last follow-up. Results: 3 patients had died of disease, distant metastasis was seen in 4 patients and local recurrence was seen in 1 patients. Complications were developed in 12 patients. (infection 6, leg length discrepancy 2, aseptic loosening 2, periprosthetic femoral fracture 1, screw loosening 1) Mean value of total functional scores were 81.2% in proximal femur, 77.4% in distal femur, 78.1% in proximal tibia, and 80.2% in proximal humerus. The overall radiological result was relatively satisfactory. Conclusion: Our results suggest limb salvage with the $MUTARS^{(R)}$ endoprosthesis is successful with good functional and radiological results. But we should be careful with complications such as infection.

Operative Treatment of Fractures of the Midshaft Clavicle using Locking Compression Plate (Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료)

  • Chung, Nam-Sik;Hong, Ki-Do;Ha, Sung-Sik;Park, Sung-Joon;Kang, Jung-Ho;Sim, Jae-Cheon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.63-68
    • /
    • 2006
  • Purpose: To assess the effectiveness of the Locking compression plate (LCP) after open reduction for the treatment of the displaced clavicular shaft fracture, the clinical and radiologic outcome of the patients who were managed with the LCP for internal fixation after open reduction has been analyzed. Materials and Methods: We reviewed 26 cases with a displaced clavicular shaft fracture treated by internal fixation using Locking compression plate after open reduction between May 2003 and November 2004. The patients were followed up for at least six months period, and final postoperative outcome was evaluated using clinical results based on Kang's criteria, radiologic signs of fusion. Results: All fractures united by an average of 9.3 weeks without delayed union and showed fast recovery of motion fraction and shoulder function. In addition,24 cases without the fractures of proximal humerus recovered to normal range of shoulder notion within 2.9 weeks. Clinically, according to Kang's criteria, the outcome was good or better in 22 patients. The complications included shoulder joint dysfunction in two cases and keloid formation in one case, and no other complications were observed. Conclusion: The internal fixation using LCP for the treatment of displaced clavicular shaft fracture is a safe, reliable method of treatment, with few complications, and offers rapid recovery of shoulder joint function and bone union.

  • PDF

Reconstruction of Tibial Defects in Lower Extremity With Various Versions of Vascularized Fibula Transfer (다양한 형태의 생 비골 이식술을 이용한 경골의 재건)

  • Nam, Sang-Hyun;Kim, Bom-Jin;Koh, Sung-Hoon;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.1
    • /
    • pp.17-25
    • /
    • 2006
  • Twelve cases in eleven patients with segmental bone defects were treated with contralateral fibula free flap and ipsilateral island fibula flap in an antegrade, retrograde or bidirectional flow fashion. Five cases were managed with free flaps and seven were with ipsilateral fibula island transfer. Among seven cases, antegrade fashion was three, retrograde was three, and bidirectional was one. All patients were related with open tibial fractures and its sequelae except one who had open foot bone fracture. According to Gustilo's classification, ten patients were type IIIb and one was type IIIc. Basically, antegrade-flow flaps based on the peroneal vessels as in the conventional free flap were used for the proximal or middle one-third tibial defects. On the contrary, retrograde-flow flaps based on the communicating branch between the peroneal and posterior tibial vessels were used for the middle or distal one-third of the tibia. Bidirection-flow flap based on intact peroneal vessels were used for the middle portion of the tibia. The patients who have undergone ipsilateral fibula island flap had one of the following problems: a previously failed free flap, below-knee amputation of the opposite leg because of open tibial fracture, refusal to use the contralateral sound leg, or poor general condition to stand a lengthy operation. Six of the patients who have got ipsilateral fibula island flap also had an associated fibula fracture on the same leg, which was ultimately used as one of the osteotomy sites. The follow-up period was from 1 to 10 years. Two cases of free flap were failed: one patient had below-knee amputation and the other patient had ipsilateral fibula transfer. Other cases were successful and excellent hypertophy of the transferred fibula was achieved. Time to bone union ranged from 4 to 11 months. Time to full weight bearing was from 5 to 13 months after surgery. All of the transferred fibulas showed hypertrophy after weight bearing. In one case, stress fracture was developed during ambulation, which was healed conservatively. Nonunion occurred in two cases, which were treated with a long leg cast and cancellous bone graft, respectively. Length discrepancy of the legs was noted. The limb was shorter by an average 0.5 cm in three cases, longer by 1.1 cm in one case. In the case of island fibula transfer, limited arc of rotation was not a problem. Other disabling complications were not seen. We believe that these diverse modalities using a vascularized fibula will make us more comfortable to handle major bone defects.

  • PDF

Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb (오픈소스 기반 수술항법장치의 하지 골절수술 응용검토)

  • Joung, Sanghyun;Park, Jaeyeong;Park, Chul-Woo;Oh, Chang-Wug;Park, Il Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.497-503
    • /
    • 2014
  • Minimally invasive intramedullary nail insertion or plate osteosynthesis has shown good results for the treatment of long bone fractures. However, directly seeing the fracture site is impossible; surgeons can only confirm bone fragments through a fluoroscopic imaging system. The narrow field of view of the equipment causes malalignment of the fracture reduction, and radiation exposure to medical staff is inevitable. This paper suggests two methods to solve these problems: surgical navigation using 3D models reconstructed from computed tomography (CT) images to show the real positions of bone fragments and estimating the rotational angle of proximal bone fragments from 2D fluoroscopic images. The suggested methods were implemented using open-source code or software and evaluated using a model bone. The registration error was about 2 mm with surgical navigation, and the rotation estimation software could discern differences of $2.5^{\circ}$ within a range of $15^{\circ}$ through a comparison with the image of a normal bone.