• Title/Summary/Keyword: Proton-beam

Search Result 271, Processing Time 0.029 seconds

Ion-Beam Induced Changes in the Characteristics of Gd Doped Ceria (이온빔 조사에 따른 Gd-doped Ceria의 특성 변화)

  • Kim, Tae-Hyung;Ryu, Boo-Hyung;Lee, In-Ja
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.401-404
    • /
    • 2010
  • The ion-beam induced changes in the characteristics of gadolinium doped ceria (GDC) pellets have been studied by UV-visible spectroscopy (UV-vis), SEM, and XRD. Implanted ions were protons or Xe ions with the energy of 120 keV or 5 MeV. Densely sintered pristine GDC pellets have cubic fluorite structure and are brown in color. As the ion irradiation proceeded, its color gradually turned into light black and finally into dark black. XRD patterns of GDC pellets were closely related with ion energy and the penetration depth of X-ray. It showed that upon the ion irradiation (120 keV) the lattice parameter of the cubic fluorite phase just beneath the surface is increased.

Simulation of Diocotron Instability of a Hollow Electron Beam Used for the Collimation of Proton Beam

  • Jeong, Seung-Il;Lee, Yeong-Ho;Jeong, Mo-Se;Lee, Ho-Jun;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.494-494
    • /
    • 2012
  • 최근에 현대 물리학과 과학의 정점에 있는 초전도가속기 같은 고에너지 빔 가속기 시스템에서 Diocotron instability의 연구가 재조명 되고 있다. 환형의 전자 빔 사이로 프로톤 빔을 통과시키는 구조로써 자기장과 회전하는 전자빔의 상호작용에 기초를 두고 있으며 이 환형의 전자 빔이 고에너지의 프로톤 빔을 집속하는 역할을 한다. 하지만 전자빔이 진행함과 동시에 왜곡되는 현상이 발생하는데 이 왜곡되는 현상을 충분히 조절하지 못한다면 프로톤 빔의 손실과 가속하는 빔의 에너지 저하를 초래하게 될 것이고 또한 실험장치 자체에도 큰 결함을 발생 시킬 수 있다. 따라서 Diocotron instability는 가속기를 활성화 하는데 주요한 테마가 될 것이다. 환형의 전자 빔 층은 정전기적 효과로 인해서 안쪽과 바깥쪽의 속도차가 발생하게 되고 이로 인하여 drift instability 가 발생하게 되어서 왜곡이 발생하고 결국에는 몇 개의 소용돌이를 생성하게 된다. 본 연구에서는 이를 2차원 원통형 구조의 Particle-in-cell 시뮬레이션을 통하여 연구하였으며 자기장의 효과에 따른 환형의 전자빔의 왜곡현상을 지연시키는 방안에 중점을 두었다. 특히 자기장의 세기, 전자빔의 밀도, 전자빔 층의 두께, 전자빔의 프로필의 차이에 의한 결과로 연구하였다.

  • PDF

DESIGN AND FABRICATION OF THE BEAM POSITION MONITOR FOR THE PEFP LINAC

  • Kwon, Hyeok-Jung;Kim, Han-Sung;Seol, Kyung-Tae;Ryu, Jin-Yeong;Jang, Ji-Ho;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.523-528
    • /
    • 2013
  • The beam position monitor (BPM) is an essential component for the PEFP 100-MeV linac's commissioning. A prototype stripline-type linac BPM was designedfor this purpose. The electrode aperture is 20 mm in diameter, and the electrode is 25 mm long, so it can be installed between Drift Tube Linac (DTL)101 and DTL102, which is the shortest distance. One end of the electrode is connected to the Sub Miniature Type A (SMA) feed through for signal measurement, and the other end is terminated as a short. The signal amplitude of the fundamental component was calculated and compared with that of the second harmonic component. The designed BPM was fabricated and a low-power RF test was conducted. In this paper, the design, fabrication and low power test of the BPM for the PEFP linac are presented.

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Multi-film coated bipolar plates for PEMFC (Proton Exchange Membrane Fuel Cell) application (다층박막 코팅된 PEMFC (Proton Exchange Membrane Fuel Cell)용 바이폴라 플레이트)

  • Jeon, Gwang-Yeon;Yun, Young-Hoon;Cha, In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.646-648
    • /
    • 2008
  • The multi-films of a metallic film and a transparent conducting oxide (TCO, indium-tin oxide, ITO) film were formed on the stainless steel 316 and 304 plates by a sputtering method and an E-beam method and then the external metallic region of the stainless steel bipolar plates was converted into the metal nitride films through an annealing process. The multi-film formed on the stainless steel bipolar plates showed the XRD patterns of the typical indium-tin oxide, the metallic phase and the metal substrate and the external nitride film. The XRD pattern of the thin film on the bipolar plates modified showed two metal nitride phases of CrN and $Cr_2N$ compound. Surface microstructural morphology of the multi-film deposited bipolar plates was observed by AFM and FE-SEM. The electrical resistivity of the stainless steel bipolar plates modified was evaluated.

  • PDF

Surface Morphology and Electrical Property of PEMFC (Proton Exchange Membrane Fuel Cell) Bipolar Plates (고분자전해질 연료전지용 바이폴라 플레이트의 표면형상과 전기적 특성)

  • Song, Yon-Ho;Yun, Young-Hoon
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.3
    • /
    • pp.161-166
    • /
    • 2008
  • The multi-films of a metallic film and a transparent conducting oxide (TCO, indium-tin oxide, ITO) film were formed on the stainless steel 316 and 304 plates by a sputtering method and an E-beam method and then the external metallic region of the stainless steel bipolar plates was converted into the metal nitride films through an annealing process. The multi-film formed on the stainless steel bipolar plates showed the XRD patterns of the typical indium-tin oxide, the metallic phase and the metal substrate and the external nitride film. The XRD pattern of the thin film on the bipolar plates modified showed two metal nitride phases of CrN and $Cr_2N$ compound. Surface microstructural morphology of the multi-film deposited bipolar plates was observed by AFM and FE-SEM. The metal nitride film formed on the stainless steel bipolar plates represented a microstructural morphology of fine columnar grains with 10 nm diameter and 60nm length in FE-SEM images. The electrical resistivity of the stainless steel bipolar plates modified was evaluated.

Simulation Study of a High Current Proton Beam Transport for a 70MeV Cyclotron Injection

  • Choi, Y.K.;Kim, Y.S.;Hong, S.K.;Kim, J.H.;Kim, J.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.183.1-183.1
    • /
    • 2013
  • 70 MeV 사이클로트론의 인젝션 빔 라인은 Multi-CUSP 이온원에서 인출된 H- 빔을 펄스 또는 번칭하여 인플렉터를 통해 사이클로트론의 가속영역인 Dee로 전송하는 역할을 한다. 이 때, 빔을 번칭 시킴으로써 가속효율을 높이고, 손실을 줄여 높은 전류의 빔을 공급할 수 있도록 해야한다. 인젝션 시스템은 einzel lens, chopper, buncher, solenoid 등으로 구성된다. Einzel lens는 빔을 buncher의 중심으로 집속시켜 buncher의 번칭 효율을 높이고, buncher는 전기장을 이용하여 빔을 진행방향으로 집속시키는 기능을 갖는다. Chopper는 번칭된 빔을 일정 주기로 편향을 시켜 펄스 빔의 형태로 전송하는 역할을 한다. 솔레노이드는 적절한 자기장을 이용하여 빔을 집속시켜 인플렉터로 전송한다. 본 연구에서는 사이클로트론의 고전류 인젝션 시스템을 구축하고 각각의 구성요소에서 빔 envelope를 계산하고 비교하였다. SIMION code는 user가 지정한 특성을 가진 개별 입자의 궤도를 추적하는 프로그램으로 인젝션 시스템을 구성하는 각각의 컴포넌트에서의 입자의 진행모습과 buncher를 이용하여 빔의 전송 밀도가 향상됨을 확인하였다. 아울러 TRANSPORT 및 TURTLE 프로그램을 이용하여 SIMION을 통해 계산된 빔의 envelope과 비교하였다.

  • PDF

Brachytherapy: A Comprehensive Review

  • Lim, Young Kyung;Kim, Dohyeon
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.25-39
    • /
    • 2021
  • Brachytherapy, along with external beam radiation therapy (EBRT), is an essential and effective radiation treatment process. In brachytherapy, in contrast to EBRT, the radiation source is radioisotopes. Because these isotopes can be positioned inside or near the tumor, it is possible to protect other organs around the tumor while delivering an extremely high-dose of treatment to the tumor. Brachytherapy has a long history of more than 100 years. In the early 1900s, the radioisotopes used for brachytherapy were only radium or radon isotopes extracted from nature. Over time, however, various radioisotopes have been artificially produced. As radioisotopes have high radioactivity and miniature size, the application of brachytherapy has expanded to high-dose-rate brachytherapy. Recently, advanced treatment techniques used in EBRT, such as image guidance and intensity modulation techniques, have been applied to brachytherapy. Three-dimensional images, such as ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography are used for accurate delineation of treatment targets and normal organs. Intensity-modulated brachytherapy is anticipated to be performed in the near future, and it is anticipated that the treatment outcomes of applicable cancers will be greatly improved by this treatment's excellent dose delivery characteristics.

Remote handling systems for the Selective Production of Exotic Species (SPES) facility

  • Giordano Lilli ;Lisa Centofante ;Mattia Manzolaro ;Alberto Monetti ;Roberto Oboe;Alberto Andrighetto
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.378-390
    • /
    • 2023
  • The SPES (Selective Production of Exotic Species) facility, currently under development at Legnaro National Laboratories of INFN, aims at the production of intense RIB (Radioactive Ion Beams) employing the Isotope Separation On-Line (ISOL) technique for interdisciplinary research. The radioactive isotopes of interest are produced by the interaction of a multi-foil uranium carbide target with a 40 MeV 200 μA proton beam generated by a cyclotron proton driver. The Target Ion Source (TIS) is the core of the SPES project, here the radioactive nuclei, mainly neutron-rich isotopes, are stopped, extracted, ionized, separated, accelerated and delivered to specific experimental areas. Due to efficiency reasons, the TIS unit needs to be replaced periodically during operation. In this highly radioactive environment, the employment of autonomous systems allows the manipulation, transport, and storage of the TIS unit without the need for human intervention. A dedicated remote handling infrastructure is therefore under development to fulfill the functional and safety requirement of the project. This contribution describes the layout of the SPES target area, where all the remote handling systems operate to grant the smooth operation of the facility avoiding personnel exposure to a high dose rate or contamination issues.

The Characterization of Proton Irradiated BaSrFBr:Eu Film by the Coincidence Doppler Broadening Positron Annihilation Spectroscopy (동시계수 양전자 소멸 측정에 의한 양성자 조사된 BaSrFBr:Eu 박막 특성)

  • Kim, J.H.;Nagai, Y.;Lee, C.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.447-452
    • /
    • 2009
  • Enhance signal-to-noise ratio, Coincidence Doppler Broadening positron method has been applied to study of characteristics of BaSrFBr:Eu film sample. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the spectrum and the total counts of whole spectrum. The films were exposed by 0, 3, 5, and 7.5 MeV proton beams ranging from 0 to $10^{13}$ ptls. The S-parameter values were increased as increasing the exposed time and the energies, that indicated the defects generate more.