• 제목/요약/키워드: Proton Resonance Frequency Shift

검색결과 6건 처리시간 0.02초

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권4호
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

완전발달 난류 원관 유동에서의 3T 및 7T MRI를 이용한 자기공명온도계의 적용 (Application of Magnetic Resonance Thermometry (MRT) on Fully Developed Turbulent Pipe Flow using 3T and 7T MRI)

  • 류형우;백승찬;김동현;이활;오석훈;황원태
    • 한국가시화정보학회지
    • /
    • 제18권1호
    • /
    • pp.26-37
    • /
    • 2020
  • Magnetic resonance thermometry (MRT) is a technique capable of measuring three-dimensional mean temperature fields by utilizing temperature-dependent shifts in proton resonance frequency. In this study, experimental verification of the technique is obtained by measuring 3D temperature fields within fully developed turbulent pipe flow, using 3T and 7T MRI scanners. The effect of the proton resonance frequency (PRF) thermal constant is examined in detail.

온도범위에 따른 비침습적 자기공명 온도측정방법의 최적화 (Temperature-Range-Dependent Optimization of Noninvasive MR Thermometry Methods)

  • 김종민;;조영승;;김정희;이철현;오창현
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권6호
    • /
    • pp.241-250
    • /
    • 2015
  • Noninvasive temperature monitoring is feasible with Magnetic Resonance Imaging (MRI) based on temperature sensitive MR parameters such as $T_1$ and $T_2$ relaxation times, Proton Resonance Frequency shift (PRFs), diffusion, exchange process, magnetization transfer contrast, chemical exchange saturation transfer, etc. While the temperature monitoring is very useful to guide the thermal treatment such as RF hyperthermia or thermal ablation, the optimization of the MR thermometry method is essential because the range of temperature measurement depends on the choice of the measurement methods. Useful temperature range depends on the purpose of treatment methods, for example, $42^{\circ}C$ to $45^{\circ}C$ for RF hyperthermia and over $50^{\circ}C$ for thermal ablation. In this paper, MR thermometry methods using $T_1$ and $T_2$ relaxation times and PRFs-based MR thermometry are tried on a 3.0 T MRI system and their results are reported and compared. In addition, the scanning protocol and temperature calculation algorithms from $T_1$ and $T_2$ relaxation times and PRFs are optimized for the different temperature ranges for the purpose of RF hyperthermia and/or thermal ablation.

[ $^1H$ ] Nuclear Magnetic Resonance Study of Ferroelectric $(NH_4)_3H(SO_4)_2$

  • Choi, S.H.;Han, K.S.;Kwon, S.K.;Nam, S.K.;Choi, H.H.;Lee, Moo-Hee;Lim, Ae-Ran
    • 한국자기공명학회논문지
    • /
    • 제11권2호
    • /
    • pp.64-72
    • /
    • 2007
  • [ $^1H$ ] nuclear magnetic resonance (NMR) experiments have been performed at 30 - 300 K and 7 T to investigate dynamics of hydrogen bond network in the single crystal $(NH_4)_3H(SO_4)_2$. The two proton sites, ammonium proton and hydrogen-bond proton, are identified from the $^1H$ NMR MAS spectrum at 340 K. As temperature decreases, the $^1H$ NMR spectrum shifts to the higher frequency side with a larger linewidth. The spectrum at 65 K shows a distinctive change in line shape toward the ferroelectric transition at 63 K. The measured values of $T_1$ for ammonium and hydrogen-bond protons are similar in the whole range of temperature. $T_1$ of $^1H$ NMR shows a gradual decrease down to 120 K and starts to steeply increase below 100 K. Then $T_1$ shows abrupt decrease below 70 K with a sharp minimum at 63 K, where the ferroelectric transition occurs. This temperature dependence of spectrum and $T_1$ clearly prove that the large change in the dynamics of hydrogen bond network is associated with the ferroelectric phase transition at 63 K.

  • PDF

무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법 (Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder)

  • 윤문현;성미숙;인창식;이흥규;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.98-107
    • /
    • 2006
  • 자화전이영상 (MTI)은 무릎의 연골조직, 활액, 연대 등에 있는 거대분자에 붙어 분자운동에 제한을 받은 수소와 비교적 자유로운 물 분자의 수소가 두 가지 자화 상태로 서로 교환되고 있는 상태에서 한쪽 자화상태를 RF 펄스를 사용하여 포화시키면 다른 자화 상태가 교환 상황에 따라 그 신호강도가 달라지면서 영상의 대조도를 이룬다. 교차이완은 수소의 T2 이완시간이 다르면서 생기는 두 스핀 풀로 모델화하여 물 분자와 거대분자 사이의 쌍극자들의 상호교환 뿐만 아니라 물분자와 거대분자의 수소 화학교환으로 설명된다. 이에 의학영상에서 가장 필수적 요소인 신호강도와 대조도를 조절하는 능력으로서 양성자 밀도와 T2 강조 무릎영상을 획득하여 비정상적 조직과 그 변화 위에 시퀀스와 더불어 무릎 조인트의 중간신호들에 의해 무릎 연골주위의 다른 조직과의 신호강도 차이를 더욱 높이기도 한다. 또한 지방억제 기술은 조직 대조도를 증대시키고 화학전이 인공물을 제거할 뿐 아니라 움직임과 관련한 고스트 인공물을 감소시킨다. 이와 같은 지방 포화억제는 위상감각 방법 (Phase Sensitive Method)에서 물과 지방의 세차운동 주파수에 차이를 나타낸다. 본 연구에서 위상감각 방법은 Larmor 주파수 차이를 직접 사용하기 보다는 그 주파수 차이결과를 축적하여 생기는 위상 차이를 보고자 하였다. 자화전이영상이 어떻게 작동하는가는 무릎조직의 자화전이(MT)에 대한 정량적 모델로 유도되는 임상적 증거에서 주어지지만 그 자화전이 효과를 설명하는 수학적 공식화는 전방 십자형 인대 (Anterior Cruciate Ligament)파열과 관절간연골 파열과 같은 무릎관절질환을 평가하는 데 적용하였고, 자화전이 포화 효과의 계산은 MT 펄스에 의한 신호강도에 상대적 감소를 정량적으로 측정하는 자화전이률에 의해 주어졌다.糖) 및 이성화당(異性化糖)의 개발생산(開發生産)이 시급(時急)하며 이런 감미원(甘味源) 생산공장(生産工場)의 대규모화(大規模化)로 경제적(經濟的) 양산(量産)을 서둘러야 될 줄 생각(生覺)한다. 우선적(優先的)으로 소요(所要)의 효소생산(酵素生産)에 대(對)한 개발연구(開發硏究)가 앞서야 하며, 이어서 전분(澱粉)으로부터 이성화당(異性化糖)에 이르기까지 단계적(段階的) 효소처리공정(酵素處理工程)의 확립(確立)과 새로운 공정(工程)의 개발연구(開發硏究)가 이루어져야 하겠다. 나아가서 보다 더 경제적(經濟的) 감미료(甘味料)의 생산(生産)과 생산공정(生産工程)의 능율화(能率化)를 위(爲)하여 전분당화(澱粉糖化) 및 이성화(異性化) 공정(工程)의 연속화(連續化)가 필연적(必然的)이며, 이에 소요(所要) 및 불용성(不溶性) 효소(酵素)의 생산공정(生産工程)도 연구(硏究)되어야 한다.>$16.8{\sim}30.1$ kcal/mole의 범위 안에 있으며 ginsenoside-Re 및 $-Rg_1$$ginsenoside-Rb_1,\;-Rb_2$, -Rc 및 -Rd 보다 훨씬 높으므로 troil saponin이 diol saponin보다 온도(溫度)의 영향(影響)을 더 많이 받고 있었다. 마. total ginsenosides의 분해반응시(分解反應時)의 활성화(活性化)에너지($E_a$)는 17.7kcal/mole이었고 분해속도상수(分解速度常數)의 온도의존성(溫度依存性)은 $k=4.574{\times}10^8{\exp}(-8898.8/T)$의 관계식(關係式)으로 표시(表示)할 수 있다rc}C,\;30^{\circ}C,\;45^{\circ}C$ 별로 각 fine spirit에 oak chip을 넣고 숙성시킨

  • PDF

Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구 (Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm)

  • ;김태형;천송이;한용희;최기승;이광식;전재량;은충기;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.131-141
    • /
    • 2008
  • 목적: 물체 내부의 온도를 비침습적으로 측정할 수 있는 양성자 공명 주파수 이동에 의한 MR 온도영상의 재구성에 center array-sequencing 위상펼침(PU) 기법을 적용시켜 그 성능 및 유용성을 평가하고자 하였다. 대상 및 방법: MR 온도 영상에 앞서 잡음 수준이 다른 타원형 팬텀들을 컴퓨터 모의 실험으로 제작하고 제안된 PU방 법을 적용시켜 잡음에 대한 성능을 평가하였다. MR 실험은 PU 실험과 이를 이용한 온도분포영상획득 실험으로 구분하여 수행되었다. 1.5T MR 영상장치에서 무릎코일과 $T2^*$ 경사자장에코 펄스열을 이용하여 MR 영상을 얻었다. 물통, 오렌지, 아가젤 등의 팬텀을 실험 대상으로 하였고 자체 제작된 온수펌프 장치로 팬텀의 온도를 조절하였다. T 형 열전쌍 온도측정장치로 팬텀 온도를 측정하고 MR 온도영상 결과와 비교하였다. 획득된 MR영상의 위상분포는 제안된 PU방법으로 위상을 편 후 온도분포 영상을 재구성하였다. 가열 전 후의 온도변화와 MR 영상의 위상변화 관계를 이용하여 아가젤 팬텀 내의 MR온도분포 영상을 구하였다. 결과: 제안된 center array-sequencing PU 알고리즘을 이용하여 여러 팬텀에 대한 MR 위상영상의 접힘 현상을 기존 방법보다 간편하고 빠르게 제거할 수 있었고 이를 이용하여 MR 온도영상을 획득할 수 있었다. 결론: 본 연구는 제안된 center array-sequencing 위상펼침 방법이 잡음에 강하고 처리 속도가 빠를 뿐만 아니라 양성자 공명 주파수 이동의 성질을 이용한 MR 온도 영상 획득에 성공적으로 적용될 수 있음을 보였다.

  • PDF