• 제목/요약/키워드: Protective solution

검색결과 293건 처리시간 0.027초

간수, 기문혈의 당귀 약침자극이 acetaminophen으로 유발된 흰쥐의 손상간에 미치는 영향 (Effects of Angelicae gigantis Radix Aqua-acupuncture at Ganshu(BL18) and Qimen(LR14) on Liver Damage induced by Acetaminophen in Rats)

  • 박경미;문진영;안준철;최미정;남경수;임종국
    • 동국한의학연구소논문집
    • /
    • 제5권
    • /
    • pp.1-13
    • /
    • 1996
  • This study was done in order to investigate the protective effects of A.G.R.(Angelicae gigantis Radix) aqua-acupuncture on acetaminophen induced liver damage in rats. The liver damage was induced by acetaminophen (500mg/kg) injection into the peritoneum. The A.G.R. aqua-acupuncture solution was injected into the corresponding loci to Ganshu($BL_{18}$) and Qimen($LR_{14}$) of human body and a blank locus of the root of tail on four consecutive times at 0, 3, 6, and 12 hours after acetaminophen injection. And the serum GOT, GPT, LDH, ALP activities, total bilirubin, direct bilirubin levels were measured in the rats. The serum GOT, GPT, LDH ALP activities and bilirubin level were decreased comparing with that of a control group in case of A.G.R. aqua-acupuncture treated group, specially Ganshu and Qimen aqua-acupuncture treated groups showed an obvious significant decrease.

  • PDF

염산 테트라싸이클린이 이중 산부식 임플란트 표면 구조에 미치는 영향 (The influence of tetracycline-HCI for micromorphology of Thermal dual acid etched surface implants)

  • 정도민;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.265-275
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Implants with thermal dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ Tetracycline-HCI solution and sterilized saline for O.5min, 1min, 1.5min, 2min, 2.5min and 3min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation and measured surface roughness by optical interferometer. The results of this study were as follows. 1. The thermal dual acid etched surfaces showed many small peaks and valleys distributed overall surface. 2. The surface conditioning with Tetracycline-HCI and saline didn't influence on its micromorphology. In conclusion, the implant with thermal dual acid etched surface has a protective micromorphology from the detoxification with $50mg/m{\ell}$ Tetracycline-HCI and a scrubbing with cotton pellet. Therefore, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI is an effective method for peri-implantitis in case implants with thermal dual acid etched surface.

Effects of acrylamide in the presence of vitamin E on sperm parameters, chromatin quality, and testosterone levels in mice

  • Anvari, Morteza;Talebi, Ali Reza;Mangoli, Esmat;Shahedi, Abbas;Ghasemi, Mohammad Rasool;Pourentezari, Majid
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제47권2호
    • /
    • pp.101-107
    • /
    • 2020
  • Objective: The present study investigated sperm chromatin quality and testosterone levels in acrylamide-treated mice and the possible protective effects of vitamin E on the fertility potential of spermatozoa. Methods: Thirty-two adult male mice were divided equally into four groups. Group 1 was the control, group 2 received acrylamide (10 mg/kg, water solution), group 3 received vitamin E (100 mg/kg, intraperitoneal), and group 4 received both acrylamide and vitamin E. After 35 days, spermatozoa from the right cauda epididymis were analyzed in terms of count, motility, morphology, and viability. Sperm DNA integrity and chromatin condensation were assessed by acridine orange (AO), aniline blue (AB), toluidine blue (TB), and chromomycin A3 (CMA3) staining. Results: In acrylamide-treated mice, significantly lower sperm concentration, viability, motility, and testosterone levels were found in comparison with the control and acrylamide+vitamin E groups (p< 0.05). In the vitamin E group, significantly more favorable sperm parameters and testosterone levels were found than in the other groups (p< 0.05). There were also significantly more spermatozoa with less condensed chromatin in the acrylamide-treated mice than in the other groups. Moreover, significantly more spermatozoa with mature nuclei (assessed by AB, CMA3, AO, and TB staining) were present in the vitamin E group than in the control and acrylamide+vitamin E groups. Conclusion: This study revealed the deleterious effects of acrylamide on sperm parameters and sperm chromatin quality. Vitamin E can not only compensate for the toxic effects of acrylamide, but also improve sperm chromatin quality in mice.

Radiation Technology in the Preparation of Polyethylene Oxide Hydrophilic Gels and Immobilization of Proteases for Use in Medical Practice

  • E.I.Vereschagin;Han, Do-Hung;A.W.Troitsky;O.V.Grishin;S.E.Petrov;E.P.Gulyaeva;L.A.Bogdanova;M.V.Korobeinikov;V.L.Auslender
    • Archives of Pharmacal Research
    • /
    • 제24권3호
    • /
    • pp.229-233
    • /
    • 2001
  • This Paper deals with the development of a technology for making a hydrophilic gel of Polyethylene oxide reception in which radiating ability is employed to cause cross-linking of Polymers in a water solution. The gel of polyethylene oxide was shown to be nontoxic contain 5-50% of polymer and be useful in composite medicinal forms along with biologically active substances including Bac. subtilis proteases. Proteases immobilized in the gel possess high thermal stability and proteolytic activity and are readily applied in medicine. The effect of immobilized proteolytic and glucolytic enzymes of Bac. subtillis (Immozimase) on the warm ischemia-reperfusion (I/R) which can cause hepatic and jejunum injury was also studied. These enzymes were immobilized on water-soluble polymer polyethylene glycol by means of an electron beam. The number of degraanulated mast cells as well as serum ALT after I/R in the group with Immozimase was decreased to almost half as compared with the control group. Pretreatment with Immozimase resulted in significant reduction of hepatic and gut neutrophil accumulation as compared with control animals. It was concluded that Immozimase has a protective effect for hepatic and gut ischemia/reperfusion, and this effect seems to be associated with prevention of leukocyte accumulation .

  • PDF

APPLICATION OF COLD SPRAY COATING TECHNIQUE TO AN UNDERGROUND DISPOSAL COPPER CANISTER AND ITS CORROSION PROPERTIES

  • Lee, Min-Soo;Choi, Heui-Joo;Choi, Jong-Won;Kim, Hyung-Jun
    • Nuclear Engineering and Technology
    • /
    • 제43권6호
    • /
    • pp.557-566
    • /
    • 2011
  • A cold spray coating (CSC) of copper was studied for its application to a high-level radioactive waste (HLW) disposal canister. Several copper coatings of 10 mm thick were fabricated using two kinds of copper powders with different oxygen contents, and SS 304 and nodular cast iron were used as their base metal substrates. The fabricated CSC coppers showed a high tensile strength but were brittle in comparison with conventional non-coating copper, hereinafter defined to as "commercial copper". The corrosion behavior of CSC coppers was evaluated by comparison with commercial coppers, such as extruded and forged coppers. The polarization test results showed that the corrosion potential of the CSC coppers was closely related to its purity; low-purity (i.e., high oxygen content) copper exhibited a lower corrosion potential, and high-purity copper exhibited a relatively high corrosion potential. The corrosion rate converted from the measured corrosion current was not, however, dependent on its purity: CSC copper showed a little higher rate than that of commercial copper. Immersion tests in aqueous HCl solution showed that CSC coppers were more susceptible to corrosion, i.e., they had a higher corrosion rate. However, the difference was not significant between commercial copper and high-purity CSC copper. The decrease of corrosion was observed in a humid air test presumably due to the formation of a protective passive film. In conclusion, the results of this study indicate that CSC application of copper could be a useful option for fabricating a copper HLW disposal canister.

Pharmacological Properties of CDBT in Hypoxia-induced Neuronal Cell Injury and Their Underlying Mechanisms

  • Park, Sang-kyu;Jung, Eun-sun;Cha, Ji-yoon;Cho, Hyun-kyoung;Yoo, Ho-ryong;Kim, Yoon-sik;Seol, In-chan
    • 대한한방내과학회지
    • /
    • 제40권3호
    • /
    • pp.425-442
    • /
    • 2019
  • Objectives: This study aimed to reveal the pharmacological properties of the newly prescribed herbal mixture, Chenmadansamgamibokhap-tang(CDBT), against hypoxia-induced neuronal cell injury (especially mouse hippocampal neuronal cell line, HT-22 cells) and their corresponding mechanisms. Methods: A cell-based in vitro experiment, in which a hypoxia condition induced neuronal cell death, was performed. Various concentrations of the CDBT were pre-treated to the HT-22 cells for 4 h before 18 h in the hypoxia chamber. The glial cell BV-2 cells were stimulated with $IFN{\gamma}$ and LSP to produce inflammatory cytokines and reactive oxygen species. When the neuronal HT-22 cells were treated with this culture solution, the drug efficacy against neuronal cell death was examined. Results: CDBT showed cytotoxicity in the normal condition of HT-22 cells at a dose of $125{\mu}g/mL$ and showed a protective effect against hypoxia-induced neuronal cell death at a dose of $31.3{\mu}g/mL$. CDBT prevented hypoxia-induced neuronal cell death in a dose-dependent manner in the HT-22 cells by regulating $HIF1{\alpha}$ and cell death signaling. CDBT prevented neuronal cell death signals and DNA fragmentation due to the hypoxia condition. CDBT significantly reduced cellular oxidation, cell death signals, and caspase-3 activities due to microglial cell activations. Moreover, CDBT significantly ameliorated LPS-induced BV-2 cell activation and evoked cellular oxidation through the recovery of redox homeostasis. Conclusions: CDBT cam be considered as a vital therapeutic agent against neuronal cell deaths. Further studies are required to reveal the other functions of CDBT in vivo or in the clinical field.

스마트 제조혁신을 위한 보호필름 공정 제조데이터의 활용모델 설계 (The Design of Application Model using Manufacturing Data in Protection Film Process for Smart Manufacturing Innovation)

  • 차병래;박선;이성호;신병춘;김종원
    • 스마트미디어저널
    • /
    • 제8권3호
    • /
    • pp.95-103
    • /
    • 2019
  • 세계 제조업은 장기적인 경기침체, 노동 원가 및 원자재 가격 상승으로 성장 한계에 봉착하게 되었으며, 이에 대한 해결방안으로 ICT와 센서 기술을 바탕으로 제조업의 4차 산업혁명을 진행하고 있다. 이러한 흐름에 따라 화학 산업에서의 스마트공장보급 확산과 스마트제조 기술 향상을 위해, 본 논문은 스마트 제조혁신을 위한 보호필름 공정 제조데이터 활용모델의 설계를 제안한다. 보호필름 공정 중에서 원료 배합 및 교반, 압출, 그리고 검수 공정에 대해서 온도, 압력, 습도, 그리고 동영상 및 열화상의 제조 데이터를 획득한다. 또한 획득된 제조 데이터는 대용량 스토리지에 저장되며, AI 서비스에 의한 시계열 및 이미지 분석과 시각화가 진행된다.

Ti-Ta-Zr합금의 전기화학적 특성에 미치는 HA/TiN 코팅의 영향 (Effects of HA/TiN Coating on the Electrochemical Characteristics of Ti-Ta-Zr Alloys)

  • 오미영;김원기;최한철
    • 대한금속재료학회지
    • /
    • 제46권10호
    • /
    • pp.691-699
    • /
    • 2008
  • Electrochemical characteristics of Ti-30Ta-xZr alloys coated with HA/TiN by using magnetron sputtering method were studied. The Ti-30Ta containing Zr(3, 7, 10 and 15wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and coating, and then coated with HA/TiN, respectively, by using DC and RF-magnetron sputtering method. The analyses of coated surface and coated layer were carried out by using optical microscope(OM), field emission scanning electron microscope(FE-SEM) and X-ray diffractometer(XRD). The electrochemical characteristics were examined using potentiodynamic (-1,500 mV~ + 2,000 mV) and A.C. impedance spectroscopy(100 kHz ~ 10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructure of homogenized Ti-30Ta-xZr alloys showed needle-like structure. In case of homogenized Ti-30Ta-xZr alloys, a-peak was increased with increasing Zr content. The thickness of TiN and HA coated layer showed 400 nm and 100 nm, respectively. The corrosion resistance of HA/TiN-coated Ti-30Ta-xZr alloys were higher than that of the non-coated Ti-30TaxZr alloys, whic hindicate better protective effect. The polarization resistance($R_p$) value of HA/TiN coated Ti-30Ta-xZr alloys showed $8.40{\times}10^5{\Omega}cm^2$ which was higher than that of non-coated Ti-30Ta-xZr alloys.

Effect of pH and Concentration on Electrochemical Corrosion Behavior of Aluminum Al-7075 T6 Alloy in NaCl Aqueous Environment

  • Raza, Syed Abbas;Karim, Muhammad Ramzan Abdul;Shehbaz, Tauheed;Taimoor, Aqeel Ahmad;Ali, Rashid;Khan, Muhammad Imran
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.213-226
    • /
    • 2022
  • In the present study, the corrosion behavior of aluminum Al-7075 tempered (T-6 condition) alloy was evaluated by immersion testing and electrochemical testing in 1.75% and 3.5% NaCl environment at acidic, neutral and basic pH. The data obtained by both immersion tests and electrochemical corrosion tests (potentiodynamic polarization and electrochemical impedance spectroscopy tests) present that the corrosion rate of the alloy specimens is minimum for the pH=7 condition of the solution due to the formation of dense and well adherent thin protective oxide layer. Whereas the solutions with acidic and alkaline pH cause shift in the corrosion behavior of aluminum alloy to more active domains aggravated by the constant flux of acidic and alkaline ions (Cl- and OH-) in the media which anodically dissolve the Al matrix in comparison to precipitated intermetallic phases (cathodic in nature) formed due to T6 treatment. Consequently, the pitting behavior of the alloy, as observed by cyclic polarization tests, shifts to more active regions when pH of the solutions changes from neutral to alkaline environment due to localized dissolution of the matrix in alkaline environment that ingress by diffusion through the pores in the oxide film. Microscopic analysis also strengthens the results obtained by immersion corrosion testing and electrochemical corrosion testing as the study examines the corrosion behavior of this alloy under a systematic evaluation in marine environment.

실리콘 혼합 차폐체의 개발과 성능비교 (Development and Performance Comparison of Silicon Mixed Shielding Material)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.187-195
    • /
    • 2023
  • A shield was made by mixing materials such as bismuth(Bi) and barium(Ba) with silicon to evaluate its shielding ability. Bismuth was made into a shield by mixing a bismuth oxide(Bi2O3) colloidal solution and a silicon base and applied to a fibrous fabric, and barium was made by mixing lead oxide(PbO) and barium sulfate(BaSO4) with a silicon curing agent and solidifying it to make a shield. The test was conducted according to the lead equivalent test method for X-ray protective products of the Korean Industrial Standard. The experiment was conducted by increasing the shielding body one by one from the test condition of 60 kVp, 200 mA, 0.1sec and 100 kVp, 200 mA, 0.1 sec. At 60 kVp, 2 lead oxide-barium sulfate shields, 2 bismuth oxide 1.5 mm shields, and 5 bismuth oxide 0.3 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. At 100 kVp, 2 lead oxide-barium sulfate shields and 2 bismuth oxide 1.5 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. It was confirmed that when using 2 pieces of lead oxide-barium sulfate and 1.5 mm of bismuth oxide, respectively, it has shielding ability equivalent to that of lead. Bismuth oxide and lead oxide-barium sulfate are lightweight and have excellent shielding ability, thus they have excellent properties to be used as an apron for radiation protection or other shielding materials.