• 제목/요약/키워드: Protective current transformer

검색결과 67건 처리시간 0.023초

Comparative Analysis on Current Limiting Characteristics of Hybrid Superconducting Fault Current Limiters (SFCLs) with First Half Cycle Limiting and Non-Limiting Operations

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.659-663
    • /
    • 2012
  • The application of large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer's impedance caused the short-circuit current of the power distribution system to be increase thus, the higher short-circuit current exceeded the cut-off ratings of the protective devices such as circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. In spite of excellent current limiting performances of the SFCL, on the other hand, the efforts to apply the SFCL into power system has been delayed due to both the limited spaces for the SFCL's installation and its long recovery time after the fault removal. In order to solve these problems, a hybrid SFCL, which can perform either first half cycle limiting of first half cycle non-limiting operation, has been developed by corporation of LSIS (LS Industrial System) and KEPCO (Korea Electric Power Corporation). In this paper, we tried to requirements hybrid SFCL by PSCAD/EMTDC. Simulation results of our analysis of the hybrid SFCL is that its accompanied the characteristics both the limit the fault current and quick recovery caused by the less impact from superconductor.

보호계전기용 CT의 여자특성 자동측정 시스템 개발 (Development of an Automatic Excitation Characteristics Measurement System of the Protective Relaying CT)

  • 권성원;김문석;김재영;이성하;정재갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.868-869
    • /
    • 2008
  • An automatic excitation characteristics measurement system for the protective relaying current transformer(CT) with accuracy of about 1 % has been developed. The system can be used up to 2 kV and 10 A at power frequency. The developed system can calculate the voltage and current at knee points of $30^{\circ}$ and $45^{\circ}$ tangents in accordance with IEEE standard by the interpolation in log scale. The excitation curve of the CT is plotted in auto-scale simultaneously with measuring rms voltage and current at the secondary of the CT.

  • PDF

Double quench and fault current limiting characteristics due to winding ratio of transformer type SFCL with third winding

  • Han, Tae-Hee;Ko, Seok-Cheol;Lim, Sung-Hun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권3호
    • /
    • pp.38-42
    • /
    • 2019
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. And capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system need a counter measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as an effective solutions to reduce the fault current. For the above reasons various type SFCL is studied recently. In this paper, the operational characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. And another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

HCM기반 뉴로-교지 시스템을 이용한 변압기 보호 알고리즘 (Protecive Algorithm for Transformer Using Nuro-Fuzzy System based on HCM)

  • 이명윤;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.552-554
    • /
    • 2003
  • The second harmonic component is commonly used for blocking differential relay in power transformers. However, it is difficult to distinguish between inrush and internal winding fault with differential current protective relaying. This paper proposed a new method using Nuro-Fuzzy System based on HCM(Hard C-Means). The proposed system is more objective and systematic than existing model. The data used in input are 3-phase primary voltage and fundamental harmonic of differential current. Various states of transformer are simulated using BCTRAN and HYSDAT of EMTP. As a result of the application of algorithm in various cases, the exact discrimination between internal winding fault and inrush is performed.

  • PDF

광전자식 과전류 보호계전기의 구현 및 성능 평가 (Implementation and Performance Evaluation of Opto-Electronic OverCurrent Relay)

  • 박병석;안성준;장문종;우희곤
    • 제어로봇시스템학회논문지
    • /
    • 제6권3호
    • /
    • pp.284-290
    • /
    • 2000
  • The measurement of electric current using optical techniques provides a number of important practical advantages including effective isolation from high line potentials and freedom from the saturation effects observed in conventional current transformers. In this work the optical current sensor which uses thin YIG(Yittrium Ion Garnet) film as a Faraday element has been developed. We have characterized this optical current sensor and implemented it to the OOCR(Opto-electronic OverCurrent Realy) Performance of the OOCR shows the possibility of replacing the present overcurrent relays with OOCR.

  • PDF

Dempster 결합룰에 의한 전력용 변압기 외란상태판정 (Disturbance State Identification of Power Transformer Based on Dempster's Rule of Combination)

  • 강상희;이승재;권태원;김상태;강용철;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1479-1485
    • /
    • 1999
  • This paper proposes a fuzzy decision making method for power transformer protection to identify an internal fault from other transient states such as inrush, over-excitation and an external fault with current transformer (CT) saturation. In this paper, analyzing over 300 EMTP simulations of disturbances, four input variables are selected and fuzzified. At every sampling interval from half to one cycle after a disturbance, from the EMPT simulations, different fuzzy rule base is composed of twelve if-then fuzzy rules associated with their basic probability assignments for singleton- or compound-support hypotheses. Dempster's rule of combination is used to process the fuzzy rules and get the final decision. A series of test results clearly indicate that the method can identify not only an internal fault but also the other transients. The average of relay operation times is about 12(ms). The proposed method is implemented into a Digital Signal Processor (TMS320C31) and tested.

  • PDF

내삽법 기반의 최소자승법을 이용한 개선된 CT 포화 복원 알고리즘 (An Enhanced Compensation Algorithm for the CT Saturation Using Interpolation-based LSQ(Least Square) Fitting Method)

  • 류기찬;강상희;이봉현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.14-15
    • /
    • 2006
  • A saturation of magnetic flux in the core may occur when a large primary current flows when the iron-cored current transformer is used. This saturation makes the distorted secondary current of the CT. the distorted secondary current may cause the mal-operation or operation time delay of protective relays. CT compensation algorithm using The LSQ(Least Square) fitting method has a problem. It needs to acquire enough data for executing this algorithm without an error. In this paper, an enhanced algorithm using interpolation based LSQ(Least Square) Fitting Method is proposed. The Lagrange Interpolation Method is used for the interpolation and CT is simulated by EMTP. The results show that the proposed algorithm can accurately compensate a distorted secondary current more than existing Algorithm when the saturation severely occurs.

  • PDF

연계형 태양광발전설비의 새로운 오동작 방지 및 재병입 알고리즘 제안 (Algorithm for Preventing Malfunction and Reclosing in Grid-Connected PV Systems)

  • 황민수;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.70-76
    • /
    • 2012
  • In general, the unidirectional power flow is normal in distribution feeders before activation of distributed power source such as PV. However, the interactive power flow is likely to occur in case of the power system under distributed generation. This interactive power flow can cause an unexpected effect on convectional protection coordination systems designed based only on the unidirectional power flow system. When the power line system encounters a problem, the interactive power flow can be a contributed current source and this makes the fault current bigger or smaller compared to the unidirectional case. The effect of interactive power flow is varied depending on the location of the point to ground fault, relative location of the PV, and connection method. Therefore it is important to analyse characteristics of fault current and interactive flow for various transformer connection and location of the PV. This paper proposes a method of improved protection coordination which can be adopted in the protective device for customers in distribution feeders interconnected with the PV. The proposed method is simulated and analysed using PSCAD/EMTDC under various conditions.

Fuzzy 추론을 이용한 전력용 변압기 보호계전 알고리즘 (Power Transformer Protective Relaying Algorithm based on Fuzzy Decision Making)

  • 김상태;이승재;강상희;최면송;윤상현;이태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.249-251
    • /
    • 2001
  • The two fuzzy criteria to distinguish the internal fault from the inrush for the power transformer protection have been identified. They are based on the terminal voltage, fundamental and second harmonic component of differential current. A systemetic way to determine the associated fuzzy membership function is also proposed.

  • PDF