• Title/Summary/Keyword: Protective action distance

Search Result 7, Processing Time 0.025 seconds

A Study on Adequacy Assessment of Protective Action Distance in Hazardous Chemical Accident by AERMOD Modeling (AERMOD 모델링 분석을 통한 유해화학물질 누출사고 시 방호활동거리의 적정성 평가연구)

  • Lim, Chea-Hyun;Doh, Sang-Hyeun
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.7-11
    • /
    • 2015
  • In Korea, The protective action distance based on Canada's ERG has been adopted for safety of residents in case of hazardous chemicals leakage accident. However, it couldn't respond properly on the accidents because of geographical and meteorological differences between two nations. In this study, It was found that the protective action distance varies depending on season and terrain, Through AERMOD modeling analysis for the petrochemical complex reflected local geographical data and meteorological conditions.

Improvement of Damage Range Calculation for First Response to Chemical Accidents (화학사고의 일차 대응을 위한 피해영향범위 산정 개선 방안)

  • Lee, Deok Jae;Ahn, Jae-Hyun;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • Calculation of the damage impact of chemical accidents is an important element in site, and the initial isolation distance and the protective action distances are significant factors in coping the chemical accident. In this study, three major cities that represent each Province were selected, and the safety distances were calculated considering regional climate conditions. The results were compared with the prescribed values in Emergency Response Guidebook. It is concluded that the regional meteorological conditions such as temperature, vapour pressure, relative humidity, wind speed, and cloud cover should be reflected in estimating the initial isolation distance and the protective action distance.

Considerations of the Optimized Protective Action Distance to Meet the Korean Protective Action Guides Following Maximum Hypothesis Accidents of Major KAERI Nuclear Facilities

  • Goanyup Lee;Hyun Ki Kim
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.52-57
    • /
    • 2023
  • Background: Korea Atomic Energy Research Institute (KAERI) operates several nuclear research facilities licensed by Nuclear Safety and Security Commission (NSSC). The emergency preparedness requirements, GSR Part 7, by International Atomic Energy Agency (IAEA) request protection strategy based on the hazard assessment that is not applied in Korea. Materials and Methods: In developing the protection strategy, it is important to consider an accident scenario and its consequence. KAERI has tried the hazard assessment based on a hypothesis accident scenario for the major nuclear facilities. During the assessment, the safety analysis report of the related facilities was reviewed, the simulation using MELCOR, MACCS2 code was implemented based on a considered accident scenario of each facility, and the international guidance was considered. Results and Discussion: The results of the optimized protective actions were 300 m evacuation and 800 m sheltering for the High-Flux Advanced Neutron Application Reactor (HANARO), the evacuation to radius 50 m, the sheltering 400 m for post-irradiation examination facility (PIEF), 100 m evacuation or sheltering for HANARO fuel fabrication plant (HFFP) facility. Conclusion: The results of the optimized protective actions and its distances for the KAERI facilities for the maximum postulated accidents were considered in establishing the emergency plan and procedures and implementing an emergency exercise for the KAERI facilities.

Near-explosion protection method of π-section reinforced concrete beam

  • Sun, Qixin;Liu, Chao
    • Geomechanics and Engineering
    • /
    • v.28 no.3
    • /
    • pp.209-224
    • /
    • 2022
  • In this study, the numerical analysis model of π-beam explosion is established to compare and analyze the failure modes of the π-beam under the action of explosive loads, thus verifying the accuracy of the numerical model. Then, based on the numerical analysis of different protection forms of π beams under explosive loads, the peak pressure of π beam under different protection conditions, the law of structural energy consumption, the damage pattern of the π beam after protection, and the protection efficiency of different protective layers was studied. The testing results indicate that the pressure peak of π beam is relatively small under the combined protection of steel plate and aluminum foam, and the peak value of pressure decays quickly along the beam longitudinal. Besides, as the longitudinal distance increases, the pressure peak attenuates most heavily on the roof's explosion-facing surface. Meanwhile, the combined protective layer has a strong energy consumption capacity, the energy consumed accounts for 90% of the three parts of the π beam (concrete, steel, and protective layer). The damaged area of π beam is relatively small under the combined protection of steel plate and aluminum foam. We also calculate the protection efficiency of π beams under different protection conditions using the maximum spalling area of concrete. The results show that the protective efficiency of the combined protective layer is 45%, demonstrating a relatively good protective ability.

The Estimated Evacuation Time for the Emergency Planning Zone of the Kori Nuclear Site, with a Focus on the Precautionary Action Zone

  • Lee, Janghee;Jeong, Jae Jun;Shin, Wonki;Song, Eunyoung;Cho, Cheolwoo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.196-205
    • /
    • 2016
  • Background: The emergency planning zone (EPZ) of the city of Busan is divided into the precautionary actions zone (PAZ) and the urgent protective action planning zone; which have a 5-km radius and a 20-km to 21-km radius from the nuclear power plant site, respectively. In this study, we assumed that a severe accident occurred at Shin-Kori nuclear unit 3 and evaluated the dispersion speed of radiological material at each distance at various wind speeds, and estimated the effective dose equivalent and the evacuation time of PAZ residents with the goal of supporting off-site emergency action planning for the nuclear site. Materials and Methods: The total effective dose equivalent, which shows the effect of released radioactive materials on the residents, was evaluated using the RASCAL 4.2 program. In addition, a survey of 1,036 residents was performed using a standardized questionnaire, and the resident evacuation time according to road and distance was analyzed using the VISSIM 6.0 program. Results and Discussion: According to the results obtained using the VISSIM and RASCAL programs, it would take approximately 80 to 252.2 minutes for permanent residents to move out of the PAZ boundary, 40 to 197.2 minutes for students, 60 to 232.2 minutes for the infirm, such as elderly people and those in a nursing home or hospital, and 30 to 182.2 minutes for those temporarily within the area. Consequently, in the event of any delay in the evacuation, it is estimated that the residents would be exposed to up to $10mSv{\cdot}h^{-1}$ of radiation at the Exclusion Area Boundaries (EAB) boundary and $4-6mSv{\cdot}h^{-1}$ at the PAZ boundary. Conclusion: It was shown that the evacuation time for the residents is adequate in light of the time lapse from the initial moment of a severe accident to the radiation release. However, in order to minimize the evacuation time, it is necessary to maintain a system of close collaboration to avoid traffic congestion and spontaneous evacuation attempts.

Protective Effect of Sesaminol Glucosides on Memory Impairment and ${\beta}$, ${\gamma}$-Secretase Activity In Vivo (Sesaminol Glucosides의 기억력 회복능 및 ${\beta}$, ${\gamma}$-Secretase)

  • Lee, Sun-Young;Son, Dong-Ju;Ha, Tae-Youl;Hong, Jin-Tae
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.168-173
    • /
    • 2005
  • Alzheimers disease (AD) is the most prevalent form of neurodegenerations associated with aging in the human population. This disease is characterized by the extracellular deposition of beta-amyloid (A ${\beta}$) peptide in cerebral plaques. The A ${\beta}$ peptide is derived from the ${\beta}$-amyloid precursor protein ( ${\beta}$APP). Photolytic processing of ${\beta}$APP by ${\beta}$-secretase(beta-site APP-cleaving enzyme, BASE) and ${\gamma}$-secretase generates the A ${\beta}$ peptide. Several lines of evidence support that A ${\beta}$-induced neuronal cell death is major mechanisms of development of AD. Accordingly, the ${\beta}$-and ${\gamma}$-secretase have been implicated to be excellent targets for the treatment of AD. We previously found that sesaminol glucosides have improving effect on memory functions through anti-oxidative mechanism. In this study, to elucidate possible other mechanism (inhibition of ${\beta}$-and ${\gamma}$-secretase) of sesaminol glucosides, we examined the improving effect of sesaminol glucosides in the scopolamine (1 mg/kg/mouse)-induced memory dysfunction using water maze test in the mice. Sesaminol glucosides (3.75, 7.5 mg/kg/6ml/day p.o., for 3 weeks) reversed the latency time, distance and velocity by scopolamine in dose dependent manner. Next, ${\beta}$-and ${\gamma}$-secretase activities were determined in different regions of brain. Sesaminol glucosides dose-dependently attenuated scopolamine-induced ${\beta}$-secretase activities in cortex and hippocampous and ${\gamma}$-secretase in cortex. This study therefore suggests that sesaminol glucosides may be a useful agent for prevention of the development or progression of AD, and its inhibitory effect on secretase may play a role in the improving action of sesaminol glucosides on memory function.

A Study on Improvement Plan for Selecting Boundary Areas to Respond to Chemical Accidents and Terrorism (화학물질 사고·테러 대응을 위한 경계구역 선정 개선방안 연구)

  • Jeon, Byeong-Han;Kim, Hyun-Sub;Lee, Hyun-Seung;Park, Choon-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.60-66
    • /
    • 2020
  • This paper presents a method for improving the selection of boundary areas suitable for Korea's situation based on domestic and foreign case studies on the establishment of boundary areas to protect people and the environment from chemical substances in response to chemical accidents and chemical terrorism. Currently, various related ministries are divided into hot zones, warm zones, and cold zones in common, but in specific areas, they are used in different ways in terms of terminology utilization. Therefore, it was suggested that the boundary areas be divided into four zones: hot zone, warm zone, cold zone, and safety zone. In addition, the terms warm zone and safety zone should be re-established. The existing ERPG acute exposure standard does not take into account various exposure times. Therefore, it is unsuitable for long-term exposure, so the priority of application should be AEGL, ERPG, PAC, and IDLHs. The CARIS information provision method is classified into substances that can or cannot be diffused or classified as indoor leaks. In addition, the wind direction trust line and the ERG's initial separation distance and protective action distance are expressed together so that they can be used for accident responses.