• Title/Summary/Keyword: Protective Performance

Search Result 512, Processing Time 0.025 seconds

The Review of Specification for SPDs used in Railway Signalling Equipment (철도신호설비용 서지보호기에 대한 규격 검토)

  • Lee, Tae-Hoon;Park, Ki-Bum;Jeon, Yong-Joo;Ryu, Young-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.596-602
    • /
    • 2008
  • Recently, there are increasing social needs for safe operation of trains and comforting for passengers. But lightning surges are responsible for serious disturbances such as damage, permanent degradation or temporary erratic operation of sensitive electronics circuits and systems. The purpose of this paper is to identify the requirements for Surge Protective Devices(SPDs) used in protecting railway signalling system. In this paper, we describes tests and requirements which establish methods for testing SPDs and determining their performance.

  • PDF

Solvent Transport Characteristics of Glassy Polymers and its Analysis (유리고분자의 용매전달특성 및 그 해석)

  • 김덕준
    • Membrane Journal
    • /
    • v.8 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • The study on penetrant transport in glassy polymers has been actively pursued for decades because of its growing significance in polymer processing and related applications such as not only membranes, but corrosion protective coatings, microlithography, microelectronic fabrication, etc. In membranes application of polymeric materials, successful utilization requires understanding of how solvents penetrate, swell, and sometimes dissolve polymeric materials under various environmental conditions, as their permselecdve performance is significantly affected by it. The expose of polymer membranes to solvents may result in the structural failure due to mechanical softening, embrittlement or crazing.

  • PDF

A Study on the Development and Application of Digital Protective Relay for DC Feeding System of Light Rail Transit System (경전철 직류급전계통을 위한 디지털 보호제어장치의 개발 및 적용에 관한 연구)

  • Baek, Byung-San;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.77-86
    • /
    • 2005
  • The DC protection and control device for the feeding system of a Light Rail Transit(LRT) system is developed. For the development, the short circuit characteristics in the system are analyzed. As a result a protection algorithm for the DC fault selective relay (50F) is newly proposed, and principles of the DC fault selective relay, Line Test Device (LTD), DC Over Current Relay (DC OCR) are introduced From the development, the specifications and codes used to be unclear have become clarified and summarized. Moreover, the methods to examine the protective characteristics and Electromagnetic Compatibility (EMC) are established Finally, the performance and the effectiveness of the developed protective relay have been verified with the test based on IEC. For the reliability of the system, the relay has been installed and is being operated at the test track of the LRT system at Gyeong-San.

Polymer/Inorganic Nanohybrid Membrane on Lithium Metal Electrode: Effective Control of Surficial Growth of Lithium Layer and Its Improved Electrochemical Performance (리튬 금속 전극상 고분자/무기물 나노복합막 형성: 리튬층의 효과적 표면성장 제어 및 전기화학적 특성 향상)

  • Jeong, Yohan;Seok, Dohyeong;Lee, Sanghyun;Shin, Weon Ho;Sohn, Hiesang
    • Membrane Journal
    • /
    • v.30 no.1
    • /
    • pp.30-37
    • /
    • 2020
  • Polymer/inorganic composites were used as a protective layer of lihitum metal electrode for effective suppression of lithium dendrite. PVDF-HFP was used as an polymer material and TiO2 nanoparticle was used as an inorganic material. PVDF-HFP is a highly flexible polymer that acts as a matrix of inorganic materials while TiO2 nanoparticle improves the mechanical strength and ion conductivity of the protective layer. The as-synthesized protective hybrid membrane exhibited good dispersion of TiO2 in the PVDF-HFP matrix by SEM, AFM and XRD analyses. Furthermore, the electrochemical analysis showed that the polymer-inorganic composite retained high coulombic efficiency of 80% and low overpotential, less than 20 mV until the 100th cycles due to the improved mechanical properties and ion conductivity in comparison to the control sample (untreated and PVDF-HFP polymers/Cu).

Development of Chemical Vapor Sampler for Man-in-Simulant Test(MIST) (화생방 개인보호체계 시험평가용 화학증기 흡착 샘플러의 개발)

  • Jung, Hyunsook;Lee, Kyoo Won;Kah, Dongha;Jung, Heesoo;Ko, Chung Ah;Choi, Geun Seob;Park, Hyen Bae;Lee, Hae Wan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.387-394
    • /
    • 2015
  • We have recently developed a cost-effective and pouch-type chemical vapor sampler which consists of a selectively permeable high density polyethylene(HDPE) membrane, aluminum/nylon barrier film, and adsorbents. Since the sampler mimics the actual adsorption process that occurs when the skin is exposed to chemical vapors, it can be applied to man-in-simulant test(MIST) to determine the protective capability of individual protective ensembles for chemical warfare agents. In this study, we describe the manufacturing process of samplers and results for performance testing on MIST. Methyl salicylate(MeS) is used to simulate chemical agent vapor and the vapor sampler was used to monitor chemical concentration of MeS inside the protective suit system while worn. Values of protection factors(PF) were also analyzed to provide an indication of the protection level of the suit system evaluate by MIST. The results obtained by home-made samplers(ADD samplers) and commercially avaliable ones(Natick samplers) showed no significant differences.

Thermal Packaging for Firefighters' Personal Protective Elctronic Equipments (소방대원 개인보호용 전자장비 패키징 기술개발)

  • Park, Woo-Tae;Jeon, Jiwon;Choi, Han Tak;Woo, Hee Kwon;Woo, Deokha;Lee, Sangyoup
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.319-325
    • /
    • 2015
  • While the conventional personal protective equipments (PPEs) covers a variety of devices and garments such as respirators, turnout gear, gloves, blankets and gas masks, several electronic devices such as personal alert safety system (PASS) and heads-up displays in the facepiece have become a part of firefighters personal protective equipments through past several years. Furthermore, more advanced electronic sensors including location traking sensor, thermal imaging caerma, toxic gas detectors, and even physiological monitoring sensors are being integrated into ensemble elements for better protection of firefighters from fire sites. Despite any electronic equipment placed on the firefighter must withstand environmental extremes and continue to properly function under any thermal conditions that firefighters routinely face, there are no specific criteria for these electronics to define functionability of these devices under given thermal conditions. Although manufacturers provide the specifications and performance guidelines for their products, their operation guidelines hardly match the real thermal conditions. Present study overviews firefighter's fatalities and thermal conditions that firefighters and their equipments face. Lastly, thermal packaging methods that we have developed and tested are introduced.

A study on Protective Coordination of MCA for Performing of the Pad Mounted Transformer's inside Protective Device (지상변압기의 내부 보호장비 작동을 위한 MCA 보호협조에 대한 연구)

  • Hyun, Seung-Yoon;Kim, Chang-Hwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.5-7
    • /
    • 2022
  • KEPCO's plan is undergoing a trial operation to replace the open-loop section with ring main units configuration where underground distribution lines are installed, by linking the multi-way circuit breakers auto (MCA) on the power side of each pad-mounted transformer. However, ring main units application mentioned above may cause the ripple effects, when implementing the configuration without a study of protection coordination. Because ring main units with classical pre-set protection devices contribution in fault condition didn't consider yet. For the reliable ring main units operation, it is necessary to resolve several protection issues such as the protection coordination with substation side, prevention of the transformer inrush current. These issues can radically deteriorate the distribution system reliability Hence, it is essential to design proper protection coordination to reduce these types of problems. This paper presents a scheme of ring main units' configuration and MCA's settings of time-current curves to preserve the performance of protection coordination among the switchgears considering constraints, e.g. prevention of the ripple effects (on the branch section when a transformer failure occurs and the mainline when a branch line failure occurs). It was confirmed that the propagation of the failure for each interrupter segment could be minimized by applying the proposed TCC and the interrupter settings for the MCAs (branch, transformer). Further, it was verified that the undetected area of the distribution automation system (DAS) could be supplemented by having the MCA configurated ring main units operate first, instead of the internal protection equipment in the transformer such as the fuse, STP when a transformer failure occurs.

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

Development of a Blended Corrosion, Scale and Micro-Organism Inhibitor for Open Recirculating Cooling System

  • Choi, Dong-Jin;You, Seung-Jae;Kim, Jung-Gu;Hwang, Woo-Suk
    • Corrosion Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.89-94
    • /
    • 2005
  • This paper presents the results of a study that was undertaken to optimize the ratio of the components of a new multi-component inhibitor blend composed of orthophosphate/ phosphonates/ acrylate copolymer/ isothiazolone. The effects of newly developed inhibitor on carbon steel dissolution in synthetic cooling water were studied through weight loss tests, electrochemical tests, scale tests, and micro-organism tests. The obtained results were compared to blank (uninhibited specimen) and showed that developed inhibitor revealed very good corrosion, scale, and micro-organism inhibition simultaneously. All measurements indicated that the efficiency of the blended mixture exceeded 90 %. The inhibitive effects arose from formation of protective films which might contain calcium phosphate, calcium phosphonate, and iron oxide. The nature of protective films formed on the carbon steel was studied by scanning electron microscopy (SEM) and auger electron spe ctroscopy (AES). Inhibitor used in this study appeared to have better performance for scale inhibition due to their superior crystal modification effect and excellent calcium carbonate scale inhibition properties. The effect of inhibitor on microorganisms was evaluated through minimum inhibitory concentration (MIC) test. All kinds of micro-organisms used in this study were inhibited under 78ppm concentration of inhibitor.