• 제목/요약/키워드: Protection time

검색결과 2,901건 처리시간 0.035초

국내 PBD 기술의 정립을 위한 해외 성능적 피난안전설계사례에 관한 조사 (A Study on PBD case of Evacuation in Japan for PBD Approach of Korea.)

  • 김동은;서동구;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.322-327
    • /
    • 2008
  • Fire safety provisions have to be determined through Performance -based design in many project. There is a need for quick estimation of evacuation time for scenario analysis in hazard assessment. The key equations on estimating evacuation time have to be known. In Japan There are many experience of PBD according to the Architectural law. It is the aim of this study to investigate the PBD case of Evacuation in Japan for PBD Approach of Korea.

  • PDF

정전구간 최소화를 위한 분산전원 보호 (Distributed generation protection technique to minimize the outage section)

  • 강용철;이병은;김은숙;황태근;이지훈;차선희;박종민;정태영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.450-452
    • /
    • 2005
  • Distributed generation (DG) plays an important role in the power system nowadays. Over-current relay, widely used in the DG protection, causes a wide outage section and long time delay. This paper proposes a DG protection technique to minimize the outage section. The proposed method uses three directional over-current relays with time delay, which are connected to the point of common coupling. The method can minimize the outage section.

  • PDF

페트리네트를 이용한 전력계통의 보호시스템 모델링과 고장진단 (Protection Systems Modeling and Fault Diagnosis of Power System Using Petri Nets)

  • 최진묵;노명균;홍상은;오용택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1136-1138
    • /
    • 1999
  • This paper describes a new method of the modeling of protection system and fault diagnosis in power systems using Petri nets. The Petri net models of protection system are compose of the operating process of protective devices and the fault diagnosis process. Fault diagnosis model which makes use of the nature of Petri net is developed to overcome the drawbacks of methods that depend on operator knowledge. The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method covers online processing of real-time data from SCADA.

  • PDF

Real Time Watermark Embedding/Detecting System for HDTV

  • Hahm Sang Jin;Lee KeunSik;Park KenuSoo
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2004년도 정기총회 및 학술대회
    • /
    • pp.285-288
    • /
    • 2004
  • High-quality digital broadcasting contents are susceptible to illegal copy and unauthorized redistribution, which makes broadcasters difficult to protect valuable media assets. So, broadcasters and content providers need the technology for copyright protection of professional digital content. Digital watermarking technology is one of the most actively developed solutions for the copyright protection. This paper suggests the requirements of watermarking technology in DTV(Digital TV) environment for copyright protection and shows the developed real-time watermark embedding/detecting system for HD(High Definition)/SD(Standard Definition) video and experimental results of the system against watermark attack tests. Our watermarking system meets the watermarking requirements of invisibility, robustness and security of DTV environment.

  • PDF

고관성부하용 전동기보호를 위한 속도감지형 과전류계전기 연구 (Study of Speed-biased Overcurrent Relay for High-Inertia Drive Motor)

  • 임진옥;조성돈;강인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.506-508
    • /
    • 1995
  • The relay protection engineers are sometimes faced with the difficulties in full protection of high-inertia drive motors during acceleration period. The problem results from lower permitted locked rotor time of the motor compared with motor starting time. Even though the various types of protection relay and other device (Speed switch, Distance relay) are used, the full protections against abnormal starting conditions may not be available. So, the development of a new speed-biased overcurrent relay is suggested in this paper. This paper also presents that speed-biased overcurrent relay can fully protect the high-inertia motor during abnormal starting condition by computer simulation.

  • PDF

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • 제3권2호
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

강구조 내화성능의 이론적 평가방법에 관한 조사연구

  • 성시창
    • 방재기술
    • /
    • 통권20호
    • /
    • pp.42-47
    • /
    • 1996
  • Prior to real fire test, theoretical of the fire resistant performance of the structural ele-ments is often less time consuming and less costly to calculate it, than to determine the perform-ance experimentally. This study is aimed at introduction of estimating methods of the fire resistant performance of the steel structural elements not by the actual fire tests but by the mathematical models.

  • PDF

Evaluation of Corrosion Protection for Epoxy and Urethane Coating by EIS under Various Cyclic Corrosion Tests

  • Hyun, Jonghun;Shon, Minyoung
    • Corrosion Science and Technology
    • /
    • 제10권3호
    • /
    • pp.95-100
    • /
    • 2011
  • Protective coatings play an important role in the protection of metallic structures against corrosive environment. The main function of anticorrosive coating is to prevent the materials from corrosive agents, such as water, oxygen and ions. In the study, the corrosion protection properties of urethane and epoxy coating systems were evaluated using EIS methods exposed to the corrosion acceleration test such as Norsok M501, Prohesion and hygrothermal cyclic test. AFM analysis of the coating systems was carried out to monitor the change of roughness of coatings. Urethane coating system was more stable than the epoxy coating under given cyclic conditions. Water uptake into the urethane coatings was less than that into the epoxy coating. The urethane coating system showed better corrosion protection than epoxy coating system based on the changes of the impedance modulus at low frequency region with exposure time. Consequently, the corrosion protection properties of the epoxy and urethane coatings was well correspond with their surface roughness changes and water uptakes.

풍력발전단지 보호를 위한 내외부 고장 판별 알고리즘 (A Protection Algorithm Discriminating Between Internal and External Faults for Wind Farms)

  • 권영진;강상희
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.854-859
    • /
    • 2007
  • A wind farm consists of many wind generator(WG)s therefore, it is generally a complex power system. A wind farm as a distributed generation(DG) affects utility power system. If a conventional protection schemes are applied, it is difficult to detect faults correctly and the schemes can't provide proper coordination in some cases. This paper presents a protection algorithm for a wind farm which consists of a looped collection circuit. Because the proposed algorithm can distinguish between an internal fault and an external fault in a wind farm, The proposed algorithm can disconnect the faulted section in a wind farm. This algorithm is based on an overcurrent protection technique with the change of the ratio of the output current of a generator to the current of the looped line connected to each generator to collect the each generator's power. In addition, operating time of the algorithm is shortened by using the voltage drop at a generator collection point. The performance of the proposed algorithm was verified under various fault conditions using PSCAD/EMTDC simulations.

과부하상태의 변동을 고려한 디지털보호계전기의 최적보호알고리즘 연구 (A Study of the Best Suited Algorithm for Digital Protection Relay in Fluctuated Overload Condition)

  • 이창호;백영식;김병진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.21-23
    • /
    • 2005
  • Recently, in power system, even though the needs of digital protection relay are highly increased, there are some problem in the field during apply digital protection relay. When the relay are in the fluctuated overload condition, existing algorithm calculate the trip time only with the measured current of just previous stage, and when the load current fluctuate between overload and normal condition, existing algorithm sometimes dose not make the relay trip. This thesis will study about these kinds of existing algorithm problem in digital protection relay, and will suggest the best suited algorithm for digital protection relay in fluctuated overload condition.

  • PDF