• Title/Summary/Keyword: Protection time

Search Result 2,901, Processing Time 0.034 seconds

Short-circuit Protection Circuit Design for SiC MOSFET Using Current Sensing Circuit Based on Rogowski Coil (Rogowski Coil 기반의 전류 센싱 회로를 적용한 SiC MOSFET 단락 보호 회로 설계)

  • Lee, Ju-A;Byun, Jongeun;Ann, Sangjoon;Son, Won-Jin;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.214-221
    • /
    • 2021
  • SiC MOSFETs require a faster and more reliable short-circuit protection circuit than conventional methods due to narrow short-circuit withstand times. Therefore, this research proposes a short-circuit protection circuit using a current-sensing circuit based on Rogowski coil. The method of designing the current-sensing circuit, which is a component of the proposed circuit, is presented first. The integrator and input/output filter that compose the current-sensing circuit are designed to have a wide bandwidth for accurately measuring short-circuit currents with high di/dt. The precision of the designed sensing circuit is verified on a double pulse test (DPT). In addition, the sensing accuracy according to the bandwidth of the filters and the number of turns of the Rogowski coil is analyzed. Next, the entire short-circuit protection circuit with the current-sensing circuit is designed in consideration of the fast short-circuit shutdown time. To verify the performance of this circuit, a short-circuit test is conducted for two cases of short-circuit conditions that can occur in the half-bridge structure. Finally, the short-circuit shutdown time is measured to confirm the suitability of the proposed protection circuit for the SiC MOSFET short-circuit protection.

JHPS-KARP-ARPS Joint Program for Commemoration of 2021 Bo Lindell Medal to Discuss the Future of Radiation Protection among Young Scientists and the Award Recipient, Dr. Ogino

  • Fujibuchi, Toshioh;Ogino, Haruyuki;Taek, Han Ki;Tani, Kotaro;Emes, Daniel
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.2
    • /
    • pp.80-82
    • /
    • 2021
  • Dr. Haruyuki Ogino, a member of the Japan Health Physics Society (JHPS), was awarded the 2021 Bo Lindell Medal by the International Commission on Radiological Protection (ICRP). To commemorate this, the "Joint JHPS-KARP-ARPS program for young radiation protection (RP) scientists to discuss the future of RP" was organized via a web meeting system. First, Dr. Ogino gave a lecture, and then young researchers selected from each academic society made presentations on the future of RP. After the presentations by the three researchers, a free talk was held-young researcher groups of each country being active is a great opportunity to collaborate and exchange information. It was emphasized that the low awareness of knowledge related to radiation has been common to all of the participating countries. Thus, it is necessary to utilize communication via web technology, as done for this program, effectively. One of the biggest advantages for Asia and Oceania is that we do not have a significant time difference. The round-table discussion was concluded by expressing the hope of active exchange and development of young researchers in the future.

A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities (대규모 위락시설의 피난안전성능 평가에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.165-173
    • /
    • 2009
  • As the Performance Based Fire Protection Design is legislated, studies on a fire and evacuation are actively in progress. The Performance Based Fire Protection Design should be developed toward enlarging the Life safety. In addition, the Performance Based Fire Protection Design shall not merely review the aspects of fire fighting but it shall also include regulations pertaining to evacuation stipulated in laws and regulations for buildings. This study performed an evacuation time prediction based on OO Night Club, one of the multiplex use facilities located in Gwang-ju Metropolitan City in order to suggest as a referential data for the Performance Based Fire Protection Design implementation. To do this, I investigated domestic and foreign regulations and research papers related to evacuation and went to visit the actual site and collected materials. The collected data was then used as ones to input in Simulex, an evacuation program to measure evacuation time. The collected data was then used as data to input in Simulex, an evacuation program to measure evacuation time. Through this particular research and results, the study was able to suggest a few concerning areas.

A study on SFCL systems for power system application (실계통적용을 위한 초전도한류시스템에 대한 연구)

  • Lee Seung Ryul;Kim Jong Yul;Yoon Jae Young
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.51-56
    • /
    • 2005
  • The recovery time of developing SFCL(Superconducting Fault Current Limiter) has an uncertainty. In general, the recovery time is estimated at 1 sec and more, even though the Process of SFCL technology is considered. However, auto reclosing time of circuit breaker is 0.3 sec in Korean power system. It is impossible to apply only one SFCL to power system because the recovery time is over the reclosing time of protection system. This study proposes two new SFCL systems for power system application. The proposed systems consider auto reclosing action for the protection in practical power system and consist of tow parallel SFCLS.

A Protection Algorithm for DC Railway Systems Using Estimation of Time Constant Based on Fourier Transform (Fourier 변환 기반 시정수 추정 알고리즘을 이용한 직류 급전계통 보호 알고리즘)

  • Kwon, Y.J.;Choi, D.M.;Kang, S.H.;Han, M.S.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.14-16
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. To detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares was presented. But, It have a weakness about harmonic to calculate time constant. So in this paper, new protection algorithm for DC railway systems using estimation of time constant based on fourier transform was presented.

  • PDF

Transformer Differential Relay by Using Neural-Fuzzy System

  • Kim, Byung Whan;Masatoshi, Nakamura
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.157.2-157
    • /
    • 2001
  • This paper describes the synergism of Artificial Neural Network and Fuzzy Logic based approach to improve the reliability of transformer differential protection, the conventional transformer differential protection commonly used a harmonic restraint principle to prevent a tripping from inrush current during initial transformer´s energization but such a principle can not performs the best optimization on tripping time. Furthermore, in some cases there may be false operation such as during CT saturation, high DC offset or harmonic containing in the line. Therefore an artificial neural network and fuzzy logic has been proposed to improve reliability of the transformer protection relay. By using EMTP-ATP the power transformer is modeled, all currents flowing ...

  • PDF

SEQUENTIAL CONFIDENCE INTERVALS WITH ${\beta}-PROTECTION$ IN A NORMAL DISTRIBUTION HAVING EQUAL MEAN AND VARIANCE

  • Kim, Sung-Kyun;Kim, Sung-Lai;Lee, Young-Whan
    • Journal of applied mathematics & informatics
    • /
    • v.23 no.1_2
    • /
    • pp.479-488
    • /
    • 2007
  • A sequential procedure is proposed in order to construct one-sided confidence intervals for a normal mean with guaranteed coverage probability and ${\beta}-protection$ when the normal mean and variance are identical. First-order asymptotic properties on the sequential sample size are found. The derived results hold with uniformity in the total parameter space or its subsets.

Protection Assessment using Reduced Power System Fault Data

  • Littler, T.B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.172-177
    • /
    • 2007
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. The paper discusses the application of the reduction method for expedient fault analysis and protection assessment.

Sequential Estimation with $\beta$-Protection of the Difference of Two Normal Means When an Imprecision Function Is Variable

  • Kim, Sung-Lai;Kim, Sung-Kyun
    • Journal of the Korean Statistical Society
    • /
    • v.31 no.3
    • /
    • pp.379-389
    • /
    • 2002
  • For two normal distribution with unknown means and unknown variances, a sequential procedure for estimating the difference of two normal means which satisfies both the coverage probability condition and the $\beta$-protection is proposed under some smoothness of variable imprecision function, and the asymptotic normality of the proposed stopping time after some centering and scaling is given.

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF