• 제목/요약/키워드: Protection test

검색결과 2,047건 처리시간 0.03초

국내 낙석방지울타리의 적정성 파악을 위한 현장 실물 실험 및 설계기준 제시 (In Situ Rockfall Tests for Evaluation of Rockfall Protection Fences)

  • 구호본;박혁진;이경미;김규한;이재욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.629-634
    • /
    • 2000
  • Rockfall protection fence which is used for mitigation of rockfall hazard, has been constructed without consideration of lithology, height and dip angle of rock slope. However, those factors should be considered for the construction of the protection fence. In addition, the protection fence should be evaluated its performance by in-situ test in order to utilize the fence effectively. This is the first full sized rockfall test in Korea. For this test, the rock cut slope whose height is about 20 m and dip angle is 65 $^{\circ}$ has been chosen. Based on the preliminary simulation procedure, four different concrete balls (0.5 ton, 1.0 ton, 2.0 ton and 5.0 ton) were prepared and four different types of protection fence were constructed. The results of this test will be utilized in the establishment of rockfall protection fence construction manual.

  • PDF

Fusible Link Type 감열체 성능시험보고 (A Report on Test Results of Fusible-Link Type Heat Responsive Links)

  • 권오승
    • 방재기술
    • /
    • 통권10호
    • /
    • pp.5-8
    • /
    • 1991
  • This report is explained about test results of heat responsive links for fire protection service, such as fire dampers and fire doors, automatic fire suppression systems and so forth. The testing program was progressed divided by two testing items, external appearance test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

태양광전원의 연계에 의한 배전계통 보호기기의 최적 운용방안에 관한 연구 (Optimal Operation Methods of Protection Devices in Distribution Systems with PV Systems)

  • 김병기;박재범;유경상;노대석
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1485-1491
    • /
    • 2011
  • This paper deals with the technical problems for the protection devices, by simulating test facilities of protection coordination for Photovoltaic systems. In order to analyze the operation characteristics for the protection devices in the case that the Photovoltaic systems with bi-directional power supply are located in the feeder, this paper proposes the test facilities composed of model distribution system, protection device and model Photovoltaic systems. By performing the simulation for operation characteristics for the protection devices based on the test facilities, this paper presents the malfunction mechanism for the protection devices. The test results show that this paper is practical and effective for the technical guideline for the Photovoltaic systems.

지능형 보호기기 적용 태양광 인버터 성능시험 (Performance Test of an Integrated Electronic Protection Device Based Photovoltaic Inverter)

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1744-1750
    • /
    • 2007
  • This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.

액체로켓엔진 비상보호시스템 연구 (Study on the Emergency Protection System of Liquid Rocket Engine)

  • 김승한;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.97-103
    • /
    • 2011
  • 본 논문에서는 엔진 비상보호시스템 구성 시 주요 고려 사항과 엔진 선행 개발 시험에서의 적용사례를 제시하였다. 액체로켓엔진 선행 개발 시험을 위해 적용된 비상보호시스템은 시험 중 발생한 모든 오작동 상황에서 오류 없이 작동하여 시험을 중지함으로써 추가적인 오작동의 전파를 방지하여 시험시제와 시험설비를 안전하게 보호하는 역할을 성공적으로 수행하였다. 본 연구 결과는 향후 엔진시험을 위한 비상보호시스템 개발 시 유용하게 활용될 것이다.

  • PDF

전기체 구조시험을 위한 고성능 과하중 방지 모듈 개발

  • 채동철;김성찬;황귀철;성경진;심재열;황인희
    • 항공우주기술
    • /
    • 제3권2호
    • /
    • pp.208-216
    • /
    • 2004
  • 항공기 전기체 구조시험에 사용되는 기존의 과하중 방지모듈의 성능을 개량하여 고성능의 과하중방지 모듈을 개발하였다. 항공기 전기체 구조시험 수행시에는 예기치 않은 오류(자연재해로 인한 정전사고, 시험체의 파손, 설계강도 미달로 인한 시험정지 등)로 인해 시험하중보다 큰 하중이 시험체에 가해질 수 있다. 이 때 발생한 과하중을 해소하여 시험체를 파손으로부터 보호하는 과하중 방지기능이 필요하다. 본 논문에서는 상용의 기존 과하중 방지모듈에 대해 구성요소별로 기능을 살펴보고, 기존 제품을 이용하여 구조시험을 수행하는 도중 나타난 문제점을 분석하였다. 또한, 기존 과하중 방지모듈이 갖고 있는 문제점을 개선한 고성능 과하중 방지모듈의 개발에 대해 기술하였다.

  • PDF

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

소형 위성 발사체의 페이로드 페어링부에 대한 음향 가진 시험 (Acoustic test of the payload fairing of Korea satellite launch vehicle)

  • 박순홍;서상현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.220-223
    • /
    • 2007
  • Acoustic test of the payload fairing of Korea satellite launch vehicle was conducted to verify the performance of acoustic protection system installed inside the payload fairing. This paper briefly introduces the acoustic test procedures and its results. Overall 148 dB acoustic loads were exerted on the payload fairing structures which mated with the upper stage structure of the launch vehicle. In order to verify the increase of insertion loss by the acoustic protection system, two kinds of test were performed. One is conducted with acoustic protection system and the other without acoustic protection system. Internal acoustic loads as well as external ones were measured and the measured insertion losses were compared with the requirement. The results showed that the acoustic protection system increases the insertion loss by more than 6 dB above 125 Hz. They also indicated that some design modification of Helmholtz resonator array is required to increase the insertion loss at a cavity resonant frequency.

  • PDF

경량전철 시험선로의 디지털 직류보호제어장치 개발 및 적용 (Development and Application of Digital D.C Protection Relay for the test line of Light Rail Transit)

  • 전용주;김수남;김지홍;백병산;이현두
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1373-1375
    • /
    • 2004
  • This paper presents the design of DC protection Relay for Light Rail Transit system, which is very beginning product in domestic. Protection Function characteristic, principle and I/O interface including interlock signal has been introduced. The protection algorithm and EMC characteristics have been certified by official organization and Type test report has been introduced. Up to date in domestic, the test procedure for DC Protection relay hasn't been established so the new method and test equipment based on IEC regulations are proposed. Finally the product will be proved based on field test.

  • PDF

수술실 간호사의 방사선 방어행위의 영향 요인 (Factors Affecting Radiation Protection Behaviors among Operating Room Nurses)

  • 김진;김진선;김현례
    • 성인간호학회지
    • /
    • 제28권6호
    • /
    • pp.680-690
    • /
    • 2016
  • Purpose: This study was designed to identify knowledge, attitude, environment, and self-efficacy among perioperative nurses in terms of radiation protection and to describe those factors affecting radiation protection behaviors. Methods: The sample was comprised of 128 perioperative nurses who agreed to participate in this descriptive study. Data were collected from a self-administered questionnaire and were analyzed using the t-test, analysis of variance, Mann-whitney U test, Kruskal-Wallis test, Pearson's correlation, and multiple regression analyses. Results: Radiation protection behaviors were significantly different by participant's gender, length of career as a perioperative nurse, educational level and prior experience with radiation protection education. Radiation protection behaviors were significantly correlated with radiation protection environment and self-efficacy in terms of radiation protection behaviors. In the multiple linear regression models, radiation protection environment and self-efficacy on radiation protection behaviors were statistically significant predictors of radiation protection behaviors, which accounted for 50.3% of variance in dependent variable. Conclusion: This study concluded that radiation protective environment in operating room is important to promote radiation protective behaviors and radiation safety management program to enhance self-efficacy is highly recommended.