• 제목/요약/키워드: Protection schemes

검색결과 213건 처리시간 0.026초

The Inter-tie Protection Schemes of the Utility Interactive Dispersed Generation Units for Distribution Automatic Reclosing

  • Park, Joon-Ho;Kim, Jae-Chul;Moon, Seung-Il
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권4호
    • /
    • pp.166-173
    • /
    • 2002
  • Dispersed Generation (DG) units significantly effect the existing distribution protection practices. Therefore, new protection practices of the distribution system interconnected with DG units should be reevaluated and developed. In this paper, a new inter-tie protection scheme of DG units for distribution automatic reclosing is proposed. The impact of DG units on existing radial-sectionaliser coordination is analyzed. And the effects of the distribution reclosing type (radial and passive reclosing) on DG dynamics are analyzed and classified. From the results of the DG dynamic responses by the reclosing type, i.e. radial and passive reclosing, the inter-tie protection schemes of DG are introduced to improve the reliability and availability of utility interactive DG. The proposed schemes are proved and evaluated by a case study using PSCAD/EMTDC simulation.

분산전원이 연계된 배전계통의 고장특성을 고려한 방향성 보호계전 방식 적용 연구 (Application of Directional Over Current Protection Schemes Considering the Fault Characteristics in the Distribution System with Dispersed Generation)

  • 정원욱;이학주;권성철;채우규
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.97-107
    • /
    • 2010
  • Penetration of distributed generator(DG) to power distribution system can cause malfunction of existing protection schemes. Because grid interconnected DG can contribute fault currents and make bidirectional current flows on the system, fault contributions from DG can cause an interference of protection relay operation. Therefore, over current protection device of the distribution system with DGs need directional protection schemes. In this paper, improved directional protection algorithms are proposed for the distribution system with DG considering their fault characteristics. And than, these directional protection algorithms are tested and validated in various fault conditions. From the simulation results, it can be seen that the proposed directional protection algorithms are practically efficient for the radial distribution system with DG.

Design of Unequal Error Protection for MIMO-OFDM Systems with Hierarchical Signal Constellations

  • Noh, Yu-Jin;Lee, Heun-Chul;Lee, Won-Jun;Lee, In-Kyu
    • Journal of Communications and Networks
    • /
    • 제9권2호
    • /
    • pp.167-176
    • /
    • 2007
  • In multimedia communication systems, efficient transmission system design should incorporate the use of matching unequal error protection (UEP), since source coders exhibit unequal bit error sensitivity. In this paper, we present UEP schemes which exploit differences in bit error protection levels in orthogonal frequency division multiplexing (OFDM) systems over frequency selective fading channels. We introduce an UEP scheme which improves the link performance with multiple transmit and receive antennas. Especially, we propose a new receiver structure based on two stage Maximum Likelihood detection (MLD) schemes which can approach the performance of a full search MLD receiver with much reduced computational complexity. In the performance analysis, we derive a generalized pairwise error probability expression for the proposed UEP schemes. Simulation results show that the proposed schemes achieve a significant performance gain over the conventional equal error protection (EEP) scheme.

MPLS망의 보호 복구 기술의 비교 (A Comparison of Restoration Schemes in Multiprotocol Label Switching Networks)

  • 오승훈;김영한
    • 한국통신학회논문지
    • /
    • 제27권4C호
    • /
    • pp.316-325
    • /
    • 2002
  • This paper investigates the restoration schemes which are applied to the MPLS domain upon a network failure. We define the following three restoration service models by combining the various restoration schemes: "FIS-based protection service" (FIS: failure indication signal), "inversion traffic protection service" and "1+1 protection service". After a qualitative analysis of the performance in them, we have analyzed it on quantitative basis by the simulation. According to the simulation results, "1+1 protection service" guarantees the fastest and most lossless restoration service among them; however, it results in consuming considerable bandwidth and producing an amount of control traffic, which means poor network utilization. On the other hand, "FIS-based protection service" spends less bandwidth and generates less control traffic, which means better network utilization, but produces poor restoration service. "Inversion traffic protection service" provides the medium restoration service and utilization between "1+1 protection service" and "FIS-based protection service."

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.

AC and DC Microgrids: A Review on Protection Issues and Approaches

  • Mirsaeidi, Sohrab;Dong, Xinzhou;Shi, Shenxing;Wang, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2089-2098
    • /
    • 2017
  • Microgrid is a convenient, reliable, and eco-friendly approach for the integration of Distributed Generation (DG) sources into the utility power systems. To date, AC microgrids have been the most common architecture, but DC microgrids are gaining an increasing interest owing to the provision of numerous benefits in comparison with AC ones. These benefits encompass higher reliability, power quality and transmission capacity, non-complex control as well as direct connection to some DG sources, loads and Energy Storage Systems (ESSs). In this paper, main challenges and available approaches for the protection of AC and DC microgrids are discussed. After description, analysis and classification of the existing schemes, some research directions including coordination between AC and DC protective devices as well as development of combined control and protection schemes for the realization of future hybrid AC/DC microgrids are pointed out.

에이전트 기반 컬러 페트리 넷을 이용한 전력 계통의 정보 흐름 모델링: 광역 보호 시스템에의 적용 (Agent-based Colored Petri Net Modeling of Grid Information Flows : Modeling of Wide Area Protection System)

  • 박병성;허견
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1347-1353
    • /
    • 2011
  • While most of the existing protection schemes have been designed with local information around individual components, these local schemes are not considered capable of protecting the modern electric power gird with growing complexity. Recent blackouts in North America and Europe have renewed the emphasis on coordinated protection and control actions to avoid systemwide blackouts, utilizing all of the available grid information. Thus, this paper proposes a new methodology, Agent-based Colored Petri Net (ACPN) modeling for systematically representing, modeling and analyzing information flows and interactions among the entities of the electric power grid. The paper demonstrates its efficacy and accuracy by investigating an ACPN model of a wide area protection system for a typical power grid. The proposed modeling and analysis schemes may further provide a framework to help assure reliability and interoperability of diverse smart grid components.

NMOS 트랜지스터와 싸이리스터 보호용 소자를 이용하는 입력 ESD 보호방식의 비교 연구 (A comparison study of input ESD protection schemes utilizing NMOS transistor and thyristor protection devices)

  • 최진영
    • 전기전자학회논문지
    • /
    • 제13권1호
    • /
    • pp.19-29
    • /
    • 2009
  • 보호용 NMOS 소자 또는 lvtr_thyristor 소자를 사용하는 고주파 CMOS IC용 입력 ESD 보호회로 방식을 대상으로, 2차원 소자 시뮬레이터를 이용하는 DC 해석, 혼합모드 과도해석 및 AC 해석을 통해 보호용 소자내 격자온도 상승 및 입력버퍼단의 게이트 산화막 인가전압 측면에서의 HBM ESD 보호강도에 대한 심도 있는 비교 분석을 시도한다. 이를 위해, 입력 ESD 보호회로가 장착된 CMOS 칩의 입력 HBM 테스트 상황에 대한 등가회로 모델링 방법을 제시하고, 5가지 HBM 테스트 모드에 대해 최대 4개의 보호용 소자를 포함하는 혼합모드 과도 시뮬레이션을 시행하고 그 결과를 분석함으로써 실제 HBM 테스트에서 발생할 수 있는 문제점들에 대한 상세한 분석을 시도한다. 이러한 과정을 통해 고주파용 입력 보호회로로서의 두 가지 보호방식의 장단점에 대해 설명하는 한편, 각 보호용 소자의 설계와 관련되는 기준을 제시한다.

  • PDF

IEC 61850 기반 후비보호계전시스템 보호협조 개선방안 (Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850)

  • 김형규;강상희
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.

Flush Optimizations to Guarantee Less Transient Traffic in Ethernet Ring Protection

  • Lee, Kwang-Koog;Ryoo, Jeong-Dong
    • ETRI Journal
    • /
    • 제32권2호
    • /
    • pp.184-194
    • /
    • 2010
  • Ethernet ring protection (ERP) technology, which is defined in ITU-T Recommendation G.8032, has been developed to provide carrier grade recovery for Ethernet ring networks. However, the filtering database (FDB) flush method adopted in the current ERP standard has the drawback of introducing a large amount of transient traffic overshoot caused by flooded Ethernet frames right after protection switching. This traffic overshooting is especially critical when a ring provides services to a large number of clients. According to our experimental results, the traditional FDB flush requires a link capacity about sixteen times greater than the steady state traffic bandwidth. This paper introduces four flush optimization schemes to resolve this issue and investigates how the proposed schemes deal with the transient traffic overshoot on a multi-ring network under failure conditions. With a network simulator, we evaluate the performance of the proposed schemes and compare them to the conventional FDB flush scheme. Among the proposed methods, the extended FDB advertisement method shows the fastest and most stable protection switching performance.