• 제목/요약/키워드: Protection function

검색결과 1,145건 처리시간 0.022초

Application of Multi-Attribute Utility Analysis for the Decision Support of Countermeasures in Early Phase of a Nuclear Emergency (원자력 사고시 초기 비상대응 결정지원을 위한 다속성 효용 분석법의 적용)

  • Hwang, Won-Tae;Kim, Eun-Han;Suh, Kyung-Suk;Jeong, Hyo-Joon;Han, Moon-Hee;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제29권1호
    • /
    • pp.65-71
    • /
    • 2004
  • A multi-attribute utility analysis was investigated as a tool for the decision support of countermeasures in early phase of a nuclear accident. The utility function of attributes was assumed to be the second order polynomial expressions, and the weighting constant of attributes was determined using a swing weighting method. Because the main objective of this study focuses on the applicability of a multi-attribute utility analysis as a tool for the decision support of countermeasures in early phase of a nuclear accident, less quantifiable attributes were not included due to lack of information. In postulated accidental scenarios for the application of the designed methodology, the variation of the numerical values of total utility for the considered actions, e.g. sheltering, evacuation and no action, was investigated according to the variation of attributes. As a result, it was shown that the numerical values of total utility for the actions are distinctly different depending on the exposure dose and monetary value of dose. As increasing in both attributes, the rank of the numerical values of total utility increased for evacuation, which is more extreme action than for sheltering, while that of no action decreased. As expected probability of high dose is higher, the break-even values for the monetary value of dose, which are the monetary value of dose when the ranking of actions is changed, were lower. In audition, as aversion psychology for dose is higher, the break-even values for dose were lower.

Improvement of a Dynamic Food Chain Model Considering the Influence of Radioactive Contamination of Foods by Rainfall During a Nuclear Emergency (원자력 사고 중 강우에 의한 음식물 오염영향을 고려한 역동학적 섭식경로모델 개선)

  • Hwang, Won-Tae;Kim, Eun-Han;Han, Moon-Hec;Choi, Yong-Ho;Lee, Han-Soo;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.21-26
    • /
    • 2002
  • For the consideration of the influence on radioactive contamination of foods due to rain during the release period of radionuclides in a nuclear accident, the previous dynamic food chain model was improved. Wet interception coefficients for the agricultural plants were derived as a function of radionuclide and rainfall amount, and mathematical formula of the model was also re-established. In the results for the same time-integrated radioactive concentrations on the ground, radioactive contamination of foods decreased greatly by rainfall, and it decreased dramatically according to increasing rainfall amount. It means that predictive contamination in foods using the previous dynamic food chain model, in which dry interception to the agricultural plants is only considered, can be overestimated. Among radionuclides considering in this study ($^{137}Cs,\;^{90}Sr,\;^{131}I$), influence of rainfall for food contamination was the most sensitive to $^{131}I$, and the least sensitive to $^{90}Sr$.

The Estimated Model of Wave Overtopping Volume according to Wave Characteristic (파랑특성(波浪特性)에 따른 월파량산정(越波量算定)에 관한 연구(硏究))

  • Park, Sang Kil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.113-128
    • /
    • 1990
  • In recent years, various types of coastal protection scheme have been studied around the coastal region. Among them, so-called zonal protection systems are being watched with interest from various points of view. In this paper, wave overtopping rate from overflowing the vertical seawall is investigated by conducting two dimensional model on the horizontal bed experiment. Hereafter this system is referred to as a artificial reef system. One is the foundation to control wave height near the surfzone and the other is function to prevent coastal disaster by suppressing net overtopping rate. The main results obtained in this study are summarized as follows. 1) Wave attenuation taken place on the artificial reef can be predicted numerically by using energy dispersion model due to wave breaking proposed by Battjes. 2) To evaluate the wave overtopping rate from a vertical seadike on various coastal constructions by weir model, a numerical procedure for prediction of overtopping is confirmed.

  • PDF

Blood Protein Adsorption and Platelet Activation on an Ultra-hydrophilic Substrate (초친수성 표면에서 혈장 단백의 흡착 및 혈소판의 변화에 관한 연구)

  • Park, Nam-Hee;Chun, Bae-Hyeock;Je, Hyung-Gon;Lee, Jun-Wan;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • 제40권4호
    • /
    • pp.273-279
    • /
    • 2007
  • Background: We evaluate the efficacy of ultra-hydrophilic coated bypass circuits in comparison with uncoated bypass circuits in a porcine cardiopulmonary bypass model. Material and Method: Normothermic cardiopulmonary bypass was peformed in 10 anesthetized pigs via the left atrium and ascending aorta with a centrifugal biopump. Ultra-hydrophilic coated bypass circuits wore used in 5 pigs (the study group) and uncoated bypass circuits were used for the control group. Platelet counts and platelet aggregation tests were peformed. The thrombin-antithrombin(TAT) complex level and total protein level were evaluated. Result: There were no significant changes En the platelet counts and aggregation ability of both groups. The TAT complex levels were not different between the two groups. The total protein level was significantly lower in the control group after cessation of cardiopulmonary bypass. Conclusion: The clinical effects of ultra-hydrophilic coating circuits were not remarkable, in terms of reducing inflammatory reaction and protection of platelet function. However, the effect of protection for blood protein adsorption might be acceptable.

A case study for the dispersion parameter modification of the Gaussian plume model using linear programming (Linear Programming을 이용한 가우시안 모형의 확산인자 수정에 관한 사례연구)

  • Jeong, Hyo-Joon;Kim, Eun-Han;Suh, Kyung-Suk;Hwang, Won-Tae;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • 제28권4호
    • /
    • pp.311-319
    • /
    • 2003
  • We developed a grid-based Gaussian plume model to evaluate tracer release data measured at Young Gwang nuclear site in 1996. Downwind distance was divided into every 10m from 0.1km to 20km, and crosswind distance was divided into every 10m centering released point from -5km to 5km. We determined dispersion factors, ${\sigma}_y\;and\;{\sigma}_z$ using Pasquill-Gifford method computed by atmospheric stability. Forecasting ability of the grid-based Gaussian plume model was better at the 3km away from the source than 8km. We confirmed that dispersion band must be modified if receptor is far away from the source, otherwise P-G method is not appropriate to compute diffusion distance and diffusion strength in case of growing distance. So, we developed an empirical equation using linear programming. An objective function was designed to minimize sum of the absolute value between observed and computed values. As a result of application of the modified dispersion equation, prediction ability was improved rather than P-G method.

Assessment of Effective Doses in the Radiation Field of Contaminated Ground Surface by Monte Carlo Simulation (몬테칼로 시뮬레이션에 의한 지표면 오염 방사선장에서의 유효선량 평가)

  • Chang, Jai-Kwon;Lee, Jai-Ki;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • 제24권4호
    • /
    • pp.205-213
    • /
    • 1999
  • Effective dose conversion coefficients from unit activity radionuclides contaminated on the ground surface were calculated by using MCNP4A rode and male/female anthropomorphic phantoms. The simulation calculations were made for 19 energy points in the range of 40 keV to 10 MeV. The effective doses E resulting from unit source intensity for different energy were compared to the effective dose equivalent $H_E$ of previous studies. Our E values are lower by 30% at low energy than the $H_E$ values given in the Federal Guidance Report of USEPA. The effective dose response functions derived by polynomial fitting of the energy-effective dose relationship are as follows: $f({\varepsilon})[fSv\;m^2]=\;0.0634\;+\;0.727{\varepsilon}-0.0520{\varepsilon}^2+0.00247{\varepsilon}^3,\;where\;{\varepsilon}$ is the gamma energy in MeV. Using the response function and the radionuclide decay data given in ICRP 38, the effective dose conversion coefficients for unit activity contamination on the ground surface were calculated with addition of the skin dose contribution of beta particles determined by use of the DOSEFACTOR code. The conversion coefficients for 90 important radionuclides were evaluated and tabulated. Comparison with the existing data showed that a significant underestimates could be resulted when the old conversion coefficients were used, especially for the nuclides emitting low energy photons or high energy beta particles.

  • PDF

A Study on the Recovery Process of Career Capital for Rehabilitation Protection Recipient (법무보호대상자의 진로자본 회복과정에 관한 연구)

  • Park, Hye-Gyeong;Han, Sun-Ok;Park, Si-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제18권12호
    • /
    • pp.400-413
    • /
    • 2017
  • It is necessary for inmates released from prison to recover their career capital in order to function normally in society. Failure to adapt to the society may not only make them unhappy but could also aggravate social safety nets. Therefore, it is critical to examine the recovery of career capital. For this study, we conducted in-depth interviews of 10 rehabilitation recipients who were supported by Korea Rehabilitation Agency. For qualitative analysis, several career topics were analyzed, such as obstacles in recovering career capital, efforts in overcoming these obstacles, what is helpful for them to overcome the obstacles and what is required for them to adapt to the career life and others. Analysis results found that the rehabilitation beneficiaries suffered loses to their career capital due to their incarceration, suffered from the loss of pride and became despondent in the process of recovery of career capital due to the negative social perception toward their social self, fear of social stigma and devaluation of themselves. In addition, the fear of possible negative evaluation was a critical factor in making their social activities more challenging. Conversely, it was found that social support in the recovery process of career capital has a positive effect. In particular, emotional support from spouses, employers, family members and friends are the most positive factors. Concerning efforts at adapting to careers, it was found that an active, leading and positive attitude toward the career were critical, showing that positive evaluation and recognition in family and social relations and the experience of success in the career were positive elements in enhancing a sense of pride. In summary, it was found that in the recovery process of career capital, dysfunctional beliefs had a negative effect, while social support had a positive effect, on the recovery of career capital.

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • 제30권4호
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.

Estimation of Instream Flow in Han River (한강에서의 하천유지유량 산정)

  • 오규창;정상만
    • Water for future
    • /
    • 제24권1호
    • /
    • pp.119-128
    • /
    • 1991
  • This study was focused on establishing the concepts of the instream flow to prevent the problems for the conceptual ambiguity and the difference in the instream flow estimation methods. The average drought flow is defined as the flow required to guarantee the minimum function of the river such as prevention of drying. The environmental control flow is defined as the flow required to control optimal river environment, the flow required for navigation, prevention of sea water-intrusion, protection of river management facilities, conservation of water Quality, fishing, prevention of river mouth closure, control of groundwater level, protection of animals and plants, and landscape. The average drought flow was obtained by flow duration analysis for the natural flows in the Han River at Indo-Bridge gaging station. When considering the 9 factors related to environment conservation, the conservation of water quality was proved to be most important. The pollutants for the river flows were estimated and the water qualities were forecasted. After comparing the water qualities in the future and water quality standards, there quired optimal dilution flow was estimated. The average drought flow and environmental control flow are all non-consumptive flows. Therefore larger flow between them, i.e., Max. (average drought flow, environmental control flow) can be the instream flow. The river management flow can be added to the flows for water utilization in the downstream. The results from this study are expected to be very helpful in the systematic river management on the other main rivers in Korea.

  • PDF

Field Experimental Study on a Soft Protecting Method for Coastal Erosion Prevention (유연재를 이용한 연안잠식방지에 대한 현장실험 연구)

  • Peng, Ta-Hsiung;Jan, Chyan-Deng
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • 제13권3호
    • /
    • pp.216-222
    • /
    • 2010
  • The structural methods used to protect coastal erosion are usually very expensive in construction as well as in spending on maintaining the structures from damage. Those structures like embankments, breakwaters, jetties etc. are commonly constructed with concretes (rigid methods) to protect coastal erosion. But those rigid methods are not effective always, because the wave energy and impact force on the structures could not be effectively reduced by those methods. For avoiding sediment erosion on coastal areas by the way of reducing wave energy, a flexible breakwater is introduced which will reduce energy and protect coastline economically and environmentally. The flexible device is a combination of flexible wire nets and stack of rings made of used vehicle tires and soft blades on surfaces. This flexible wire net is placed in between two stacks of rings. The stack of rings is mainly used to hold the flexible wire nets and the flexible wire net is mainly used to reduce wave energy and helps to deposit sediments in coastal area. For a field experiment study, the above-mentioned flexible breakwater of coastal protection has been set up at the Shuang-Chun coastal area in Tainan County since June 10, 2009. The length of the flexible device is 50.0 meters and the height is 2.0 meters. The function of the device has been examined by Typhoon Linfa during June 19~22, 2009 and by Typhoon Morakot during August 6~10, 2009. The result shows that the flexible breakwater has effectively trapped sediments and let them deposit on coastal. The depth of sediment deposition around the device was about 0.5 to 0.8 meters.