• 제목/요약/키워드: Protection Zone

검색결과 373건 처리시간 0.025초

전압붕괴 측면에서의 Zone3 보호동작 억제를 위한 제어방안 (Control strategy against undesirable zone 3 protection with respect to voltage collapse)

  • 송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.24-26
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions of relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. The proposed approach comes up with control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information which is valuable for both the timing and amount of control. The methodology is demonstrated through the modified New England 39-bus system.

  • PDF

굴삭기 장애물 인식 및 접촉방지 시스템에 관한 연구 (A Study on an Obstacle Recognition and Contact Protection System for Excavator)

  • 김성호;천종현;박경섭;임종형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.398-398
    • /
    • 2000
  • Since there is a blind zone in driver's view around the excavator, industrial accidents between the equipment and the workers within the zone have been occurred frequently. The purpose of this paper is to develop a obstacle recognition system which can prevent such an accident by providing the driver with the information on direction and distance of the obstacle within the blind zone. We designed the ultrasonic sensor based obstacle recognition system which consists of sensor arrays and a control unit connected via CAN(controller area network). The Cross-correlation technique and histogramic probability distribution method are used as a reliable obstacle detection algorithms to remove the environmental noise. The experimental results using a real excavator show the effectiveness of the system.

  • PDF

거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구 (A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System)

  • 허예림;김윤성;김혜원;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF

스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발 (Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator)

  • 이종훤
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구 (A Study on Protection of Generator Asynchronization by Impedance Relaying)

  • 이종훤
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

UN해양법 협약상의 추적권에 관한 연구 (A Study on the Right of hot pursuit of UNCLOS)

  • 성윤창
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2006년도 추계학술발표회
    • /
    • pp.15-24
    • /
    • 2006
  • 추적권은 추적국의 영해, 접속수역 기타 관할수역내에서 외국선박이 추적국의 법령을 위반한 경우 동 선박을 나포하기 위하여 공해상까지 계속하여 추적할 수 있는 권리로서 연안국이 영해나 기타 일정수역내에서 위법행위를 한 외국선박을 공해로 도주하기 전에 나포하는 것 이 용이하지 않으므로 도주하는 범법외국선박을 공해상까지 추적하여 나포하고 동선박을 연안국에 인도하여 연안국의 재판관할권을 행사하는 제도가 인정되어 왔으며 이러한 권리를 해양법상의 추적권 (the Right of hot pursuit) 라고 한다. 이에 우리나라의 해양관할권의 현황과 불법행위의 특성 등을 연구하여 해상집행력을 고찰해 보고 추적권에 관한 연구를 기술해 보았다.

  • PDF

The Importance of Corrosion Control and Protection Technology in the Refinery

  • Kim, Byong Mu;Oh, Sung Lyong
    • Corrosion Science and Technology
    • /
    • 제6권3호
    • /
    • pp.112-119
    • /
    • 2007
  • This paper presents the importance of corrosion control and protection technology with a real case study of heater tube rupture damaged by High temperature H2S-H2 corrosion in the refinery. The heater was operated at the Hydrocracking unit and the operation temperature and pressure was $340^{\circ}C$ and $18kg/cm^{3}$ respectively. Top side of the convection tube was thinned by high temperature hydrogen sulfide and hydrogen gas as a uniform corrosion and finally ruptured under operation pressure. Damaged area (Convection tube zone) was blocked by protection wall, so it was impossible to inspect with conventional nondestructive examination. Instead the elbow area which is out of the protection wall was inspected regularly to evaluate the corrosion rate of convection tube indirectly. However the operation temperature and the phase of the process stream was different between inside the chamber and outside the chamber. As a result, it caused severe corrosion to the horizontal convection tube inside the chamber comparing to the elbow outside the chamber. Finally convection tube was corroded more rapidly than the elbow and ruptured after 13 years operation. Because of the rupture, the heater was totally burned and the operation was stopped for 3 months until it has been reconstructed. To prevent this kind of corrosion problem and accident, corrosion control should be strengthened and protection technology should be improved.

어선 통항 안전 확보를 위한 어업활동보호구역과 항만·항행구역의 해양사고 비교분석 (Comparative Analysis of Marine Accidents in Fishing Activity Protection Zones and Port and Navigation Zones to Improve Fishing Vessel Security)

  • 김현동;박상원;박영수;김대원;교칸 참르율트
    • 해양환경안전학회지
    • /
    • 제29권2호
    • /
    • pp.118-126
    • /
    • 2023
  • 해양을 이용하려는 수요자 증가에 따라, 해양공간을 합리적으로 배분하기 위해 해양공간계획(Marine Spatial Planning)제도가 도입되었다. 이 중 어업활동보호구역은 수산자원보호 등 어업활동 보호를 위해 지정되었다. 그러나, 어업활동보호구역을 주로 항해하는 어선은 우리나라에서 발생하는 해양사고의 약 70 %를 차지할 정도로 위험에 노출되어 관리가 필요하다. 본 연구의 목적은 어업활동보호구역 내 어선 통항 안전 확보를 위해 어업활동보호구역과 항만·항행구역에서 발생하는 해양사고를 분석하는 것이다. 이를 위해 해양용도구역의 교통량을 조사하고 선종별, 사고 유형별, 톤수별, 사고원인별, 인명피해별로 해양사고를 조사하였다. 분석 결과 각 유형별 단위 면적당 해양사고는 대부분 항만·항행구역에서 더 많이 발생하였으나 전체적으로 발생한 해양사고는 어업활동보호구역이 높았다. 특히 인명사고가 많이 발생하여 통항 안전관리가 필요한 것으로 식별되었다.

수온 변화의 영향을 고려한 방류관 플룸의 혼합역 분석 (Mixing Zone Analysis on Outfall Plume considering Influent Temperature Variation)

  • 김지연;이중우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.247-253
    • /
    • 2004
  • As a large scale port development in coastal waters proceeds step by step and populations in the vicinity of port are getting increased, the issue on "how to dispose the treated municipal water and wastewater in harbor" brings peoples′ concern. The submarine outfall system discharges the primary or secondary treated effluent at the coastline or in deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding sea water and becomes very dilute. We intended in this paper to investigate the impact on dilution of effluent and the behavior of flume under the conditions of the seasonal and spatial temperature variations, which have not been noticeable in designing effective marine outfall system. To predict and analyze the behaviour and dilution characteristics of plume not just with the effluent temperature, but also with the seasonal variation of temperature of surround water and tidal changes, CORMIX(Cornell Mixing Zone Expert System)-GI have been applied. The results should be used with caution in evaluation the mixing zone characteristics of discharged water. We hope to help for the effective operation of outfall system, probable outfall design, protection of water quality, and warm water discharges from a power plant, etc.

  • PDF