• 제목/요약/키워드: Protection Zone

검색결과 373건 처리시간 0.028초

열 모델을 이용한 전동기 보호성능 개선 (Improving Motor Protection Using Thermal Model)

  • 장중구
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.473-479
    • /
    • 2015
  • Thermal relays are sometimes used instead of long time overcurrent relays for motor protection. But, it is difficult for any relay design engineer to adequately approximate motor heating curves which represent the average of a difficult-to-define thermal zone. Thermal relays frequently may not provide sufficient protection on heavy overloads. Digital multifunction relays are microprocessor-based devices. These relays offer highly reliable and advanced protection of motors. If a situation can be mathematically described, the microprocessor in a digital relay can be programmed to tackle that problem. Today's motor protection is accomplished with digital protective relays. Digital relays offer additional, highly important features to complement protection. The best way to prevent short in motor is to not overheat and degrade the insulation.

IEC 61850 기반 후비보호계전시스템 보호협조 개선방안 (Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850)

  • 김형규;강상희
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.

변압기의 선간 단락사고 보호를 위한 지락비율차동 계전 알고리즘의 성능향상 방법 (Improved Ground differential relaying algorithm for the protection of a line-to-line fault of transformer)

  • 강해권;김진호;김세창;박종수;박종은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.760-761
    • /
    • 2011
  • Ground differential relay is used to provide fast, sensitive, and selective protection for the wye connected and grounded electrical power equipment such as generators, power transformers, and grounding transformers. The ground differential protection only protects the ground faults within the protection zone, so that it can't protect the line-to-line fault. This paper proposes the algorithm to provide the protection for the line-to-line fault through the ground differential protection. The proposed algorithm detects the line-to-line fault of transformer using the comparison between the positive and the negative current, when the ground differential relay dose not operate. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various case studies.

  • PDF

오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰 (Examination with Transmission Line Distance Relay Setting Rule Considering Error)

  • 조성진;최면송;현승호;김종욱;이주왕;조범섭;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

경량항공기용 착수대 안전성 확보에 대한 연구 (The study on the safety of Sea Lane for LSA)

  • 신대원
    • 한국항공운항학회지
    • /
    • 제25권2호
    • /
    • pp.1-11
    • /
    • 2017
  • In this study, we surveyed the regulations of the Seaplane base and Sea Lane for the Light Sport Aircraft(LSA), and analyzed the water landing/takeoff roll distance of LSA in Korea. Based on the information, we presented the situation of the Sea Lane and the Sea Lane Protection Zone concept, to ensure the Rectangle type Sea Lane and the Omni direction type Sea Lane. We analyzed the availability elements of the safety of Sea Lane for LSA in Korea. A Rectangle type Sea Lane 350 meters long and 40 meters wide, the diameter 350 meters for the An Omni direction type Sea Lane.

위성영상 분석기술을 이용한 시흥갯벌의 지형 및 노출시간 분석 (Analysis on Topography and Exposure Duration of Siheung Tidal Flat Using Remote Sensing Techniques)

  • 구본주;김민규
    • Ocean and Polar Research
    • /
    • 제35권4호
    • /
    • pp.291-298
    • /
    • 2013
  • In order to investigate the topography and exposure duration of the Siheung tidal flat, tidal ranges and DEM constructed by remote sensing techniques were analyzed. A cross-sectional diagram of the intertidal area reveals that it is relatively flat in the upper zone and then abruptly plunges into the bottom of the main channel where elevations increase in an upstream direction. The waterline during the Highest Low Water (HLW) is drawn back to the bottom of the channel at the middle part of the tidal flat and is formed along the slant of the channel during the Lowest High Water (LHW). The intertidal zone is located between -410 cm and 510 cm in terms of elevation and its total area is $0.65km^2$. An area between the Highest High Water (HHW) and Lowest High Water (LHW), occupying about 80% of the total area, occupies $0.52km^2$ of total area and accounts for 56% of the exposure duration. The boundary of wetland protection area in the Siheung tidal flat did not exactly coincide with the intertidal regime and differs by more than 15%. This study, which precisely analyzed the tidal flat area, tidal environment, and topography, would be useful in making a conservation plan and in learning how to use a wetland protection area in a sustainable manner.

통합연안관측 시스템의 개발과 적용(수공) (Development and Application of the Integrated Coastal Observing System)

  • 박종화;이순혁
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.359-364
    • /
    • 2000
  • The paper presents the results of a study on the desired observing system which setting the high-level objectives for an integrated, sustained, national coastal observing system. Knowledge of the coastal zone is demanded by many constituencies, including fishermen, fisheries managers and climatologist, harbor pilots, coastal zone managers, environmental protection professionals etc. Many of these needs are being partially met by coastal zone observing system elements, both satellite and in situ. Nevertheless, these have not enough developed in an integrated manner and have been funded and operated to meet their own purpose. Thus, this study presents the development and application method for a national coastal zone observing system, which is integration of disparate observational systems and data sets to maximize their utility for many users and purposes.

  • PDF

디지털 거리계전기의 Zone 설정에 관한 연구 (A Study on the Zone Setting of Digital Distance Relay)

  • 이재규;정창호;정병태;안복신;김석일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.946-948
    • /
    • 1998
  • The distance relay is very important for transmission line protection. A quadrilateral zone shape is used mainly for a modern digital distance relay. The shape of quadrilateral is vendor specific. At the stage of design, the shape is determined considering all possible types of faults and diverse configurations of system. Also this type relay must be designed to avoid the operation by a sound phase at single-Phase-to-ground fault, by a sound phase at two-phase-to-ground fault. The effect of a source impedance and a load impedance is another important factor to design. In this paper, a reliable zone shape which is appropriate for the KEPCO's transmission system is provided.

  • PDF

해외 상수원 보호구역 정책에 관한 고찰 (A review of water protection zone policies in other countries)

  • 류문현
    • 한국수자원학회논문집
    • /
    • 제53권1호
    • /
    • pp.83-88
    • /
    • 2020
  • 상수원수질보호는 국민의 건강과 생존에 관한 중요한 문제이기 때문에 어느 나라 할 것 없이 상수원 수질오염을 방지하기 위해 여러 가지 정책적 노력을 기울이고 있다. 본 논고에서는 미국, 유럽 등 해외의 상수원보호구역제도와 관련된 정책을 고찰함으로써 우리나라의 상수원보호구역 제도의 정책대안을 모색하고자 한다.

A Probabilistic Approach to the Protection Capability Evaluation of Distance Relay in Transmission Systems

  • Zhang, Wen-Hao;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.407-414
    • /
    • 2010
  • This paper proposes a probability measure for the evaluation of relay performance from two aspects, namely, correct trip and no-unwanted trip. They are developed based on the relationship between relay settings and relay measurements, which follow a Gaussian probability model. The proposed method based on strict mathematical derivation is applied to protection capability evaluation of distance relays under various settings. Considering the specific attributes of each protection zone, the optimal settings are also determined accordingly. The protection capability could demonstrate clearly the relay performance under various settings and the optimal settings could provide good references for engineering applications.