• 제목/요약/키워드: Protection Zone

검색결과 373건 처리시간 0.027초

Designation and Management of Water Source Protection Areas for Indirect Intakes

  • Choi, Ji-Yong;Hwang, Dae-Ho
    • Environmental Engineering Research
    • /
    • 제15권4호
    • /
    • pp.231-237
    • /
    • 2010
  • With increased chemical and economic development activities in upstream areas, the amounts of pollutants released have increased, and as such, so has the need for positive management of water supply source areas. Although more than 90% of the water supply sources in Korea depend on direct intake from surface water, the interest in indirect intake, such as riverbank filtration water, has recently risen, with some local governments currently undertaking indirect intake. Even in cases of indirect intake, water supply source protection zones need to be assigned for the comprehensive control of pollutants. To establish water quality protection zones for indirect intake, the scope of the protection zones needed to reflect the hydrological features of the water-bearing deposits of each site. Water source protection areas were estimated and presented as the 1st (within a 100 m radius from an intake well) and 2nd (within a 2 km radius from an intake well) zones. The 1st zone was more sensitive; hence, the installation of various facilities should be prohibited, and the area should be regarded as off-limits. For the 2nd zone, appropriate management should prohibit and restrict activities already present in the water source protection zone.

토양칼럼을 이용한 초기우수 중 염양염류의 수변녹지 토양에서의 제거도 평가 (Soil Column Experiment to Evaluate Removal of Nutrients in Stormwater Runoff by Soil of Riparian Protection Zone)

  • 윤석표;최지용
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.231-235
    • /
    • 2004
  • To investigate removal effects of nutrients in stormwater runoff by soil of riparian protection zone, soil column experiment was conducted for 20 months. Artificial stormwater runoff containing phosphate and nitrate was applied on the surface of soil column twice a week, and phosphate and nitrate concentrations were measured from the leached water. Soil of riparian protection zone reduced the released amount of infiltrated water to the surrounding water. After infiltration of 1m depth of soil column, average removal rates of phosphate and nitrate were 97.7 % and 74.7 %, respectively. As main mechanisms of phosphate are adsorption to soil particle and utilization by plants, periodical replacement of soil and harvesting of plant at the end of growing season are required. For the removal of nutrients in stormwater runoff by the soil layer, soil of riparian protection zone has higher hydraulic conductivity to infiltrate stormwater. Sandy soil having hydraulic conductivity of about $1{\times}10^{-2}cm/s$ range might be appropriate for this purpose.

GIS를 이용한 상수원 보호를 위한 수변구역 지정에 관한 연구 (The Delineation of Water-Pollutant Buffering Zone for Sustaining Better Drinking Water Quality Using a GIS)

  • 김계현;윤호석;권우석
    • 환경영향평가
    • /
    • 제9권3호
    • /
    • pp.239-248
    • /
    • 2000
  • The aggravating water quality from the expansion of industrialization along with increasing population lead to develop more intensive physical measures to secure better drinking water quality. This study was mainly initiated to establish a water-pollutant buffering zone for the upper stream basin of Paldang--the major source area of drinking water for the metropolitan Seoul and suburban areas with a population more than 13 million. Two different criteria were considered in determining the buffering distance from the edge of the streamflow : 1km-width buffer zone for the special protection area which has been strictly controlled by the conventional laws for the protection of drinking water supply, and 500m-width buffer zone for the rest of the area. To delineate the exact boundaries of the water-pollutant buffering zone, GIS database was created integrating topography, hydrography, cadastral, and other related layers. The newly designated water-pollutant buffering zone would contribute to improve the water quality in a long term along with the conservation of the wet land. More study, however, should be made within the water-pollutant buffering zone such as the detailed survey of the pollutants, vegetation, and ecosystem for more effective management of the buffering zone.

  • PDF

어린이 보호구역 주·정차 방지시스템 구축에 관한 연구 (A Study on the Establishment of a Parking and Stopping Prevention System in Child Protection Zone)

  • 오은열
    • 산업융합연구
    • /
    • 제20권8호
    • /
    • pp.69-75
    • /
    • 2022
  • 초등학교 주변에는 교통약자인 어린이 교통사고를 예방하기 위하여 어린이 보호구역내 스쿨존(school zone)을 지정하여 이 구역내에서는 차량 운행속도를 30km/h 미만으로 운행함에 따라 주·정차가 금지되어 있다. 하지만 우리나라는 OECD 국가 중 어린이 교통사고 사망률이 1위라는 불명예를 안고 있다. 이와 같은 배경하에 본 연구는 어린이 보호구역에서의 다양한 도로여건에 따라 불법 주·정차 차량으로 인한 운전자 시야확보 및 주행차량에 대한 인지의 어려움 등이 상존하고 있어, 이에 어린이 보호구역 내에 불법 주·정차방지 시스템을 구축함으로써 교통약자인 어린이들에 대해 교통사고방지와 운전자 안전운전에 대한 경각심 증진에 기여하기 위함에 연구의 목적을 두었다. 연구 방법으로는 주요선행연구와 문헌조사 및 분석을 바탕으로 주·정차방지시스템에 대한 구축방안을 제시하였다. 구축방안을 통해 교통사고 방지, 스마트한 운전자의 안전운행 유도, 보행자 안전의식 강화, 운전자의 안전의식 경각심 유도 등 효과를 기대할 수 있다.

조선용 고장력강재와 보통강도강재간의 용접부위의 부식피로와 전기방식에 관한 연구 (A study on the corrosion fatigue and cathodic protection of the welded zone between high tensile strength steel and general strength steel used for the shipbuilding)

  • 전대희;김원녕;이의호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.39-50
    • /
    • 1984
  • The plane bending corrosion fatigue test was performed on the welded zone between SM58 steel plate and SM41 steel plate jointed with submerged arc welding in the air and in the natural sea water with various conditions. The main results obtained from the test are summarized as follows: 1) The welded zone of the steel plates has the lowest impact strength and the highest electrode potential, but the hardness was mediate of SM58 base and SM41 base. 2) The cathodic protection of the welded zone was also effective for the plane bending corrosion fatigue, and the optimum protection potential of the welded zone was -1,000 mV SCE. 3) The corrosion fatigue strength under the various stress conditions of the steel plate could be estimated and also the require safety factors on the design could be obtained from the plane bending fatigue limit diagram.

  • PDF

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘 (An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

외부전원법을 적용한 철근콘크리트의 방식효과 (The Method Effect of Reinforced Concrete by Applying Impressed Current Cathodic Protection)

  • 이해승;조규환;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.60-61
    • /
    • 2013
  • For reinforced concrete structures located in a sea environment, the Impressed Current Cathodic Protection (ICCP) is mostly used as a signature method to prevent steel corrosion. For this research, specimens to which the ICCP is applied were manufactured under the assumption of two following cases the specimens are exposed to various salt damage environments (submerged zone, tidal zone), and deteriorative factors (crack) occur in concrete. For the specimens manufactured, an enhancement experiment for deterioration was conducted through regular cycle change under the temperature between 15 ~ 70℃ with 70 ~ 90% humidity. Afterwards, the method effect was verified through a half-cell method and application of the ICCP derived from salt damage environments was investigated.

  • PDF

다단계 바이러스 차단 구조 연구 (Multi-level Protection Infrastructure for Virus Protection)

  • 노시춘;김귀남
    • 한국사이버테러정보전학회:학술대회논문집
    • /
    • 한국사이버테러정보전학회 2004년도 제1회 춘계학술발표대회
    • /
    • pp.187-198
    • /
    • 2004
  • virus방역 체계 관리는 network infra구조관리, traffic소통경로관리. 방역 zone설정, gateway구간 방역관리이다. 본 논문은 일반적인 방역체계 구조의 성격과 취약점을 진단하고 이를 개선할 수 있는 대책으로서 개선된 방역체계를 설계하였다. 또한 설계된 방역체계와 configuration, mechanism하에서는 어느 정도의 개선효과 나타나고 있는지 분석하였다. 개선된 다단계 방역체계 하에서는 gateway 단계에서 불필요한 mail을 걸러주므로서 server에 주는 부하는 감소하며 virus wall상의 CPU부하의 감소와 virus 치료율의 상승으로 송신 적체 건수는 감소하고 시스템 process수는 증대하고있다.

  • PDF

바이러스 차단 인프라 구조에 관한 연구 (A study on an Infrastructure for Virus Protection)

  • 노시춘;김수희;김귀남
    • 융합보안논문지
    • /
    • 제5권1호
    • /
    • pp.53-62
    • /
    • 2005
  • virus 방역 체계 관리는 network infra 구조관리, traffic 소통경로관리, 방역 zone 설정, gateway구간 방역관리이다. 본 논문은 일반적인 방역체계 구조의 성격과 취약점을 진단하고 이를 개선할 수 있는 대책으로서 개선된 방역체계를 설계하였다. 또한 설계된 방역체계와 configuration, mechanism하에서는 어느 정도의 개선효과 나타나고 있는지 분석하였다. 개선된 다단계 방역체계 하에서는 gateway 단계에서 불필요한 mail을 걸러줌으로서 server에 주는 부하는 감소하며 virus wall상의 CPU 부하의 감소와 virus 치료율의 상승으로 송신 적체 건수는 감소하고 시스템 process수는 증대하고 있다.

  • PDF