• Title/Summary/Keyword: Prosthetic and implants

Search Result 217, Processing Time 0.019 seconds

Full mouth rehabilitation with fixed prostheses by increased vertical occlusal dimension using 3D printed splint in a patient with excessive tooth wear (과도한 치아 마모 환자의 3D 프린팅 교합안정장치를 이용한 수직 교합 고경 증가를 동반한 고정성 보철물 전악 수복 증례)

  • Se-Young Kim;Soo-Yeon Shin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.215-226
    • /
    • 2023
  • Severe wear of the anterior teeth facilitates the loss of anterior guidance, which protects the posterior teeth from wear during excursive movement. Additionally, when treating patients with collapsed occlusion due to multiple tooth loss and tooth wear, it is important to determine the presence of vertical dimension loss through accurate clinical and radiographic examinations and diagnostic wax-up. The patient of this case is a 44-year-old female patient who complained of overall tooth wear and loss of posterior teeth due to bruxism and clenching habits, visited the hospital with the address of restoring masticatory function and improving aesthetic appearance through prosthetic treatment. Through model analysis and diagnostic wax-up, an increase in vertical dimension was determined, and full mouth restoration with fixed prostheses was planned. The degree of adaptation to the vertical dimension was confirmed step by step using an occlusal splint designed with CAD (Computer aided design) software and 3-D (3-Dimensional) printed, and then restored with provisional restoration and after a 4-month adaptation period, the entire dentition was restored with metal ceramic crowns and implants. Through this procedure, satisfactory treatment results were obtained in terms of function and aesthetics.

Relationship of Oral Health Status and Oral Health Care to the Quality of Life in Patients of Dental Hospitals and Clinics (치과내원 환자들의 구강건강상태와 구강건강관리 행태에 따른 삶의 질)

  • Yoon, Hyun-Seo
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.594-602
    • /
    • 2015
  • The purpose of this study was to examine the relationship of oral health status and oral health care to life. The subjects in this study were the patients who visited dental hospitals and clinics in several regions for seven months from March 2013. They got dental checkups, and a survey was conducted. The patients who received general treatment scored highest in Oral Health Impact Profile-14. Among the subfactors, the patients who received general treatment scored higher in functional limitation (8.27), physical pain (7.24), physical restrictions (7.90), social restrictions (7.79), physical limitations (8.14) and social difficulties (8.24). The patients who received orthodontic treatment scored higher in handicap (8.78). All the differences were statistically significant. As for gender gaps, the men scored higher in every factor. By age group, the older patients led a worse quality of life. By occupation, the homemakers mostly led a worse quality of life, and the patients who had no systemic diseases lived a better quality of life. All the differences were significant. Concerning self-rated health status and self-rated oral health state, the patients who found themselves to be in better health and in better oral health led a better quality of life. The differences were significant. Regarding oral health care, the patients who didn't get regular dental checkups and who could visit a dental clinic whenever they had a pain lived a better quality of life. The differences were significant. In terms of oral health status, a higher quality of life was found among the patients who had sound teeth, whose teeth received no sealant treatment, whose teeth received no filling therapy, who had no missing tooth, whose teeth received no prosthetic treatment and who had no dental implants teeth.

Functional and Radiological Results of Intermediate-term Follow Up in $MUTARS^{(R)}$ Tumor Endoprostheses ($MUTARS^{(R)}$ 종양 대치물을 이용한 사지 구제술의 기능적 및 방사선학적 중기 추시 결과)

  • Kang, Dong-Joon;Kim, Jeung-Il;Oh, Jong-Seok;Moon, Tae-Yong;Lee, In-Sook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • Purpose: This study was designed to verify intermediate-term functional and radiological results of limb salvage operation using endoprosthetic replacement system ($MUTARS^{(R)}$) used in patients with a malignant bone tumor. Materials and Methods: Thirty one cases which used $MUTARS^{(R)}$ tumor prosthesis were reviewed. The mean age of the patients was 49.2 years and the mean follow up was 39.8 months. We retrospectively reviewed complications, and evaluated functionally and radiologically by Enneking functional score, ISOLS radiological implants evaluation system at last follow-up. Results: 3 patients had died of disease, distant metastasis was seen in 4 patients and local recurrence was seen in 1 patients. Complications were developed in 12 patients. (infection 6, leg length discrepancy 2, aseptic loosening 2, periprosthetic femoral fracture 1, screw loosening 1) Mean value of total functional scores were 81.2% in proximal femur, 77.4% in distal femur, 78.1% in proximal tibia, and 80.2% in proximal humerus. The overall radiological result was relatively satisfactory. Conclusion: Our results suggest limb salvage with the $MUTARS^{(R)}$ endoprosthesis is successful with good functional and radiological results. But we should be careful with complications such as infection.

Artificial Trachea Covered by Ipithelium (상피세포 피복 인공기관의 개발)

  • 김광택;이윤신
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.739-746
    • /
    • 1997
  • A variety of experiments concerning the development of ideal prosthetic grafts for correcting circumferential tracheal defects have been performed. The requirements for an ideal tracheal prosthesis are impermeability to air, consistency to prevent collapse, and acceptance by the host tissue causing a minimum inflammatory reaction, allowing fibroblastic infiltration and epithelialization. The synthetic material, polyurethane(PU), is known as a biocompatible polymer with an inert component. In this study, the tracheal prosthesis was made from microporous PU(30 micrometer in diameter) coated with gelatin and reinforced with isoplastic rings. This procedure provides the prosthesis with a compression strength. The out side diame er of the prosthesis was 20 mm with a length of 30 mm. The gelatin used in the study was obtained from pig skin and immobilized and cross-linked by irradiation(60 Co gamma ray) to promote host tissue incorporation and render the prosthesis epithelization after implantation. Animal experiments using 10 mongrel dogs were performed to compare three kinds of prosthesis; gelatin coated polyurethane graft, uncoated polyurethane graft, and prosthesisf pericadium complex graft. After 6 weeks of implantation, the epithelialization of implants was seen on the gelatin-coated and prosthesisfpericadium complex grafts. Implanted prosthesis were complicated by airway obstruction due to anastomosis granuloma. Early tracheal stenosis was found in the uncoated graft group. Two kind of anastomosis techniques were tested on the gelatin-coated prosthesis. Everted anastomosis resulted severe granuloma than the inverted anastomosis. In the prosthesislpericadium complex graft, bacteria and inflammation at a anastomotic site was found. Based on these results, gelatin coated porous polyurethane trachea prosthesis is biocompatible and may be useful in clinical application with further investigation.

  • PDF

Digital workflow for prosthetic restoration in the pan facial fracture patient: A case report (다발성 안면 골절 환자의 보철 수복을 위한 디지털 워크플로우: 증례보고)

  • Kim, Seung-Wan;Park, Geun-Taek;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra;Ko, Kyung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.395-403
    • /
    • 2022
  • In the fracture operation of pan facial fracture, there are many cases where the shape and position of the occlusal and oral structures are abnormally changed because the index for repositioning to the original position is insufficient. And trismus and gag reflex in patients with pan facial fractures increase the difficulty of dental treatment, and the difference in the position of the jaw bone makes it difficult to restore aesthetically and functionally. In this case, digital workflows for minimal intraoral work could be selected to reduce patient discomfort and the difficulty of dental treatment. This case is using a digital workflow from implant planning to final prosthesis production in a patient with acquired skeletal grade III, trismus, and gag reflex due to pan facial fracture 15 years ago. In this case report, the use of digital workflow in a patient who has difficulty in dental treatment was able to minimize patient discomfort and obtain esthetic and functionally appropriate results.

Multiple fixed implant-supported prosthesis using temporary denture and scannable healing abutment: a case report (임시의치와 스캔가능한 치유지대주를 이용한 고정성 임플란트 보철 수복 증례)

  • Hyung-Jun Kim;Hyeon Kim;Woo-hyung Jang;Kwi-dug Yun;Sang-Won Park;Hyun-Pil Lim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.250-259
    • /
    • 2023
  • The use of digital technology in fixed prosthetic treatment using implants enables predictive treatment through diagnosis and virtual surgery by integrating clinical and radiological information of patients. Existing digital scanning methods require several components to be removed, such as removing the healing abutment and connecting the scan body. In the scannable healing abutment developed in consideration of this point, scanning is performed directly on the healing abutment, maintaining soft tissue sealing and simplifying scanning. Digital technology can also be used when obtaining the intermaxillary relationship. Recently, various digital technologies have been reported to acquire the intermaxillary relationship of edentulous patients using surgical guides, patient-specific scanning devices, or scans of the inside of temporary dentures. In this case, the implant-supported fixed prosthesis treatment was performed through scanning the scannable healing abutment and the inner side of the temporary denture to obtain the intermaxillary relationship, thereby simplifying the treatment process and obtaining aesthetically and functionally excellent clinical results.

All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report (무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례)

  • Lee, SeungJin;Jeong, Seung-Mi;Chung, Chae-Heon;Fang, YiQin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.497-507
    • /
    • 2021
  • All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.

Implant supported removable dental prosthesis with magnetic attachment in crossed occlusion: A case report (엇갈린 교합에서 implant와 magnetic attachment를 이용한 국소의치 증례)

  • Lee, Yu Jin;Lee, Richard sungbok;Lee, Suk Won;Park, Su Jung;Ahn, Su Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.53-60
    • /
    • 2017
  • When attempting to restore the oral function of a partially edentulous patient, there are a number of prosthetic treatment options available, depending on the structure of remaining teeth. For example, when only one set of maxillary and mandibular teeth are diagonally in place across from each other, it is difficult to gain stable occlusion. In this case, implants can be put in place at the corresponding edentulous area to achieve balance. By doing so, a stable occlusion can be achieved. For this case report, a patient with crossed occlusion after extraction was treated with maxillary RDP (removable dental prosthesis) and mandibular implant-supported RDP (removable dental prosthesis). Moreover, an implant fixture was placed under the posterior molar of the distal extension base diagonally across from the remaining maxillary teeth. Then, magnetic attachment was implemented. According to the patient who received the treatment, the result was functionally and aesthetically satisfactory.

A case of maxilla implant overdenture using Pekkton telescopic attachment with severe alveolar bone resorption (심한 치조골 소실이 있는 상악 무치악 환자에서 Pekkton telescopic attachment를 이용한 임플란트 피개의치 증례)

  • Park, Ha Eun;Lee, Won Sup;Lee, Cheol Won;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.189-194
    • /
    • 2019
  • It is necessary to set the correct occlusal plane and to distribute the occlusal force uniformly considering the state of the opposing dentition during the prosthetic of the single edentulous patient with severe alveolar bone resorption. Implant supported overdenture is superior to complete denture in terms of maintenance and stability, and limited implants are used in fully edentulous patients with high alveolar bone resorption. Telescopic attachments using a newly introduced material based on poly-aryl-ether-ketone (PAEK) have the advantages of typical telescopic copping, excellent abrasion resistance, and are lighter and more economical than conventional implant overdentures. In this case, we restored maxillary arch with a implant retained overdenture using the telescopic attachment made of Pekktonand the mandible was restored with fixed implant prosthesis. Through these procedures esthetic aspects and functional outcomes were satisfactorily achieved.

Comparison of Metal Artifact Reduction Algorithms in Patients with Hip Prostheses: Virtual Monoenergetic Images vs. Orthopedic Metal Artifact Reduction (고관절 인공치환술 환자에서 금속 인공물 감소 방법의 비교: 가상 단일에너지영상 대 금속 인공물 감소기법)

  • Hye Jin Yoo;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1286-1297
    • /
    • 2022
  • Purpose To assess the usefulness of various metal artifact reduction (MAR) methods in patients with hip prostheses. Materials and Methods This retrospective study included 47 consecutive patients who underwent hip arthroplasty and dual-energy CT. Conventional polyenergetic image (CI), orthopedic-MAR (OMAR), and virtual monoenergetic image (VMI, 50-200 keV) were tested for MAR. Quantitative analysis was performed in seven regions around the prostheses. Qualitative assessments included evaluation of the degree of artifacts and the presence of secondary artifacts. Results The lowest amount of image noise was observed in the O-MAR, followed by the VMI. O-MAR also showed the lowest artifact index, followed by high-keV VMI in the range of 120-200 keV (soft tissue) or 200 keV (bone). O-MAR had the highest contrast-to-noise ratio (CNR) in regions with severe hypodense artifacts, while VMI had the highest CNR in other regions, including the periprosthetic bone. On assessment of the CI of pelvic soft tissues, VMI showed a higher structural similarity than O-MAR. Upon qualitative analysis, metal artifacts were significantly reduced in O-MAR, followed by that in VMI, while secondary artifacts were the most frequently found in the O-MAR (p < 0.001). Conclusion O-MAR is the best technique for severe MAR, but it can generate secondary artifacts. VMI at high keV can be advantageous for evaluating periprosthetic bone.