• Title/Summary/Keyword: Prosthesis implantation

Search Result 84, Processing Time 0.024 seconds

Human Acellular Dermis versus Submuscular Tissue Expander Breast Reconstruction: A Multivariate Analysis of Short-Term Complications

  • Davila, Armando A.;Seth, Akhil K.;Wang, Edward;Hanwright, Philip;Bilimoria, Karl;Fine, Neil;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • v.40 no.1
    • /
    • pp.19-27
    • /
    • 2013
  • Background Acellular dermal matrix (ADM) allografts and their putative benefits have been increasingly described in prosthesis based breast reconstruction. There have been a myriad of analyses outlining ADM complication profiles, but few large-scale, multi-institutional studies exploring these outcomes. In this study, complication rates of acellular dermis-assisted tissue expander breast reconstruction were compared with traditional submuscular methods by evaluation of the American College of Surgeon's National Surgical Quality Improvement Program (NSQIP) registry. Methods Patients who underwent immediate tissue expander breast reconstruction from 2006-2010 were identified using surgical procedure codes. Two hundred forty tracked variables from over 250 participating sites were extracted for patients undergoing acellular dermis-assisted versus submuscular tissue expander reconstruction. Thirty-day postoperative outcomes and captured risk factors for complications were compared between the two groups. Results A total of 9,159 patients underwent tissue expander breast reconstruction; 1,717 using acellular dermis and 7,442 with submuscular expander placement. Total complications and reconstruction related complications were similar in both cohorts (5.5% vs. 5.3%, P=0.68 and 4.7% vs. 4.3%, P=0.39, respectively). Multivariate logistic regression revealed body mass index and smoking as independent risk factors for reconstructive complications in both cohorts (P<0.01). Conclusions The NSQIP database provides large-scale, multi-institutional, independent outcomes for acellular dermis and submuscular breast reconstruction. Both thirty-day complication profiles and risk factors for post operative morbidity are similar between these two reconstructive approaches.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.

Prognosis following dental implant treatment under general anesthesia in patients with special needs

  • Kim, Il-hyung;Kuk, Tae Seong;Park, Sang Yoon;Choi, Yong-suk;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.3
    • /
    • pp.205-213
    • /
    • 2017
  • Background: This study retrospectively investigated outcomes following dental implantation in patients with special needs who required general anesthesia to enable treatment. Method: Patients underwent implant treatment under general anesthesia at the Clinic for the Disabled in Seoul National University Dental Hospital between January 2004 and June 2017. The study analyzed medical records and radiographs. Implant survival rates were calculated by applying criteria for success or failure. Results: Of 19 patients in the study, 8 were males and 11 were females, with a mean age of 32.9 years. The patients included 11 with mental retardation, 3 with autism, 2 with cerebral palsy, 2 with schizophrenia, and 1 with a brain disorder; 2 patients also had seizure disorders. All were incapable of oral self-care due to serious cognitive impairment and could not cooperate with normal dental treatment. A total of 27 rounds of general anesthesia and 1 round of intravenous sedation were performed for implant surgery. Implant placement was performed in 3 patients whose prosthesis records could not be found, while 3 other patients had less than 1 year of follow-up after prosthetic treatment. When the criteria for implant success or failure were applied in 13 remaining patients, 3 implant failures occurred in 59 total treatments. The cumulative survival rate of implants over an average of 43.3 months (15-116 months) was 94.9%. Conclusion: For patients with severe cognitive impairment who are incapable of oral self-care, implant treatment under general anesthesia showed a favorable prognosis.

Long-term implant success at the Academy for Oral Implantology: 8-year follow-up and risk factor analysis

  • Busenlechner, Dieter;Furhauser, Rudolf;Haas, Robert;Watzek, Georg;Mailath, Georg;Pommer, Bernhard
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.3
    • /
    • pp.102-108
    • /
    • 2014
  • Purpose: Rehabilitation of the incomplete dentition by means of osseointegrated dental implants represents a highly predictable and widespread therapy; however, little is known about potential risk factors that may impair long-term implant success. Methods: From 2004 to 2012, a total of 13,147 implants were placed in 4,316 patients at the Academy for Oral Implantology in Vienna. The survival rates after 8 years of follow-up were computed using the Kaplan-Meier method, and the impact of patient- and implant-related risk factors was assessed. Results: Overall implant survival was 97% and was not associated with implant length (P=0.930), implant diameter (P=0.704), jaw location (P=0.545), implant position (P=0.450), local bone quality (P=0.398), previous bone augmentation surgery (P=0.617), or patient-related factors including osteoporosis (P=0.661), age (P=0.575), or diabetes mellitus (P=0.928). However, smoking increased the risk of implant failure by 3 folds (P<0.001) and a positive history of periodontal disease doubled the failure risk (P=0.001). Conclusions: Summing up the long-term results of well over 10,000 implants at the Academy for Oral Implantology in Vienna it can be concluded that there is only a limited number of patients that do not qualify for implant therapy and may thus not benefit from improved quality of life associated with fixed implant-retained prostheses.

Influence of the implant abutment types and the dynamic loading on initial screw loosening

  • Kim, Eun-Sook;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at $30^{\circ}$ to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for $10^5$ cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (${\alpha}$=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after $10^5$ cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.

Oral rehabilitation using implant supported fixed dental prostheses in a growing patient who underwent mandibulectomy and fibular free flap (하악골 절제술 및 비골유리피판을 시행한 성장기 환자에서 임플란트를 이용한 고정성 보철 수복 증례)

  • Lee, Hag-Young;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.268-274
    • /
    • 2020
  • Functional and esthetic recovery through reconstruction of the oral and maxillofacial system is important for patients who underwent mandibulectomy due to lesions such as oral cancer. The fibula free flap, which is frequently used in the reconstruction of the mandible, is easy to prosthetic restoration with implant placement. However, patients with growing periods have difficulty in treatment with implants when the size of the fibula is small and residual growth remains. This case is an 11-year-old female patient who underwent mandibulectomy due to osteosarcoma and reconstruction of the mandible using a fibular free flap. Functional and esthetic recovery were obtained through prosthetic restoration using implant-supported fixed prostheses. Implantation site, number of implants, and type of prostheses were considered. Implant-supported fixed prostheses were delivered at 13 years old, and after an additional 1 year observation, stable results were obtained. However, observing changes in the maxillofacial system through further examinations is necessary.

Implantation of a permanent pacemaker through the coronary sinus in a patient who underwent mechanical valve replacement for infective endocarditis with a complete atrioventricular block (완전방실차단을 동반한 감염성 심내막염 환자에서 판막치환술 후 관정맥동을 통해 좌심실을 조율하는 심박조율기 시술)

  • Jo, Kwan Hoon;Kim, Inho;Ann, Soe Hee;Oh, Yong Seog
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.113-116
    • /
    • 2014
  • A 52-year-old man was referred to our hospital due to fever and myalgia that occurred 2 weeks earlier. He showed a complete atrioventricular block on his electrocardiogram, and his vital signs were unstable. On his transthoracic echocardiograph, the 1.5 cm vegetation in the aortic valve with severe aortic regurgitation suggested infective endocarditis. His transesophageal enchocardiograph showed abscess in his mitral-aortic intervalvular fibrosa and vegetation was suspected on his anterior mitral valve leaflet. The patient underwent an emergent operation for valve replacement with temporary epicardial pacing. Intraoperatively, the septal leaflet of his tricuspid valve was injured during the debridement of the abscess pocket that was extended to the membranous septum. The aortic, mitral, and tricuspid mechanical valves were replaced with annular reconstruction without complications. After 14 days of intravenous antibiotics, we successfully changed the epicardial pacemaker into a transvenous DDD-type permanent pacemaker by placing a left ventricular lead via the coronary sinus and an atrial lead in the right atrium appendage. The patient was discharged in a tolerable state and was examined uneventfully in our hospital's outpatient clinic for 8 months.

Effect of tightening torque on the connection stability of a custom-abutment implant system: 3D finite element analysis (지대주 나사 조임 토크가 맞춤형 지대주 임플란트 시스템의 연결부 안정성에 미치는 영향: 3차원 유한 요소 해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.99-105
    • /
    • 2021
  • Purpose: This study aims to examine the stress distribution effect of tightening torques of different abutment screws in a custom-abutment implant system on the abutment-fixture connection interface stability using finite element analysis. Methods: The custom-abutment implant system structures used in this study were designed using CATIA program. It was presumed that the abutment screws with a tightening torque of 10, 20, and 30 N·cm fixed the abutment and fixture. Furthermore, two external loadings, vertical loading and oblique loading, were applied. Results: When the screw tightening torque was 10 N·cm, the maximum stress value of the abutment screw was 287.2 MPa that is equivalent to 33% of Ti-6Al-4V yield strength. When the tightening torque was 20 N·cm, the maximum stress value of the abutment screw was 573.9 MPa that is equivalent to 65% of Ti-6Al-4V yield strength. When the tightening torque was 30 N·cm, the maximum stress value of the abutment screw was 859.6 MPa that is similar to the Ti-6Al-4V yield strength. Conclusion: As the screw preload rose when applying each tightening torque to the custom-abutment implant system, the equivalent stress increased. It was found that the tightening torque of the abutment influenced the abutment-fixture connection interface stability. The analysis results indicate that a custom-abutment implant system should closely consider the optimal tightening torque according to clinical functional loads.

Surgical Treatment of Degenerative Mitral Valve Regurgitation in the Elderly: Comparison of Early and Long-Term Outcomes Using Propensity Score Matching Analysis

  • Lee, Joon Seok;Kim, Kyung Hwan;Choi, Jae Woong;Hwang, Ho Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.367-375
    • /
    • 2018
  • Background: It is unclear whether mitral valve (MV) repair for degenerative mitral regurgitation (MR) provides the same advantages in the elderly that it does in the general population. Methods: From 1994 to 2016, 188 elderly patients (mean age, $68.3{\pm}5.50years$) underwent MV repair (n=153) or MV replacement (n=35) for primary degenerative MR. Early and long-term outcomes were compared before and after propensity score matching (PSM). Results: Before PSM, there was a significant difference in operative mortality (p=0.011). Overall survival and freedom from cardiac-related death (CRD) at 5, 10, and 15 years were significantly higher in patients who underwent MV repair (p=0.039 and p=0.007, respectively). In the multivariable analysis, MV replacement was an independent risk factor of CRD. After PSM, operative mortality was not significantly lower in patients who underwent MV repair (p=0.125). Overall survival and freedom from CRD at 5, 10, and 15 years showed no significant difference between the 2 groups in the PSM cohort (p=0.207, p=0.47, respectively). There was no significant difference in freedom from reoperation before or after PSM (p=0.963 and p=0.575, respectively). Conclusion: MV repair for primary degenerative MR might be a valid option in the elderly population if successful repair is possible.

A population-based study of breast implant illness

  • Magno-Padron, David A.;Luo, Jessica;Jessop, Terry C.;Garlick, Jared W.;Manum, Joanna S.;Carter, Gentry C.;Agarwal, Jayant P.;Kwok, Alvin C.
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.353-360
    • /
    • 2021
  • Background Despite evidence supporting the safety of breast implants, some women associate their implants with adverse health effects and have called this syndrome "breast implant illness." We sought to characterize breast implant illness symptoms and to report how implant removal affects their symptoms. Methods An anonymous 20 question survey was administered to the Facebook group: "UTAH Breast Implant Illness" to characterize the symptoms these women attributed to their breast implants. Several questions allowed us to evaluate how implant removal affected women's symptoms. Results Of the 182 respondents, 97% report that implants negatively affect their health and 95% identify these symptoms with breast implant illness. Ninety-six percent of respondents had implants placed for cosmetic reasons and 51% had silicone implants. The most common symptoms associated with breast implant illness are brain fog (95%), fatigue (92%), joint pain (80%), and hair loss (74%). Sixty percent of respondents learned about breast implant illness from family/friends and/or social media platforms (56%), 40% of respondents had their implants removed, and 97% report relief of their symptoms post-removal (23% complete, 74% partial). Following explantation, there was a significant improvement in all but one reported symptom. An association was found between the number of symptoms reported prior to explantation and the number of symptoms resolving following explantation. Conclusions Breast implant illness is a syndrome characterized by fatigue, decreased focus, hair loss, and joint pain after the placement of breast implants. Nearly all patients report improvement of symptoms after implant removal. Significant efforts should be made to better understand breast implant illness and its etiology.