• Title/Summary/Keyword: Prosthesis design

Search Result 226, Processing Time 0.023 seconds

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Implant restoration considering maintenance for a patient with excessive crown height space (과도한 치관높이 공간을 가진 환자에서 유지관리를 고려한 임플란트 수복증례)

  • Ma, Juri;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • Complications increases when crown height space is excessive and one should be careful of choosing type of fixed prosthesis in case crown height space is over 12 mm. In this condition, tooth seems to be longer, therefore, it is needed to use gingival shade in aesthetically important area for fixed prosthesis. In this case, fixed prosthesis which has inappropriate maintenance and hygiene could hold food, plaque, calculus, thus increase incidence of inflammation and infection. Moreover, it could lead to chronic inflammation and infection and in that case surgical improvement could be necessary. In present case report, gingival inflammation and swelling developed around prosthesis after having made it considering articulation and aesthetic view in patient who had excessive crown height space. Finding out that design of prosthesis is a factor to make it hard to maintain oral hygiene, a temporary prosthesis which has enough interproximal space and proper emergence profile was fabricated. After two months of observation, significant abnormal symptoms are not found and oral reconstruction is performed using fixed prosthesis with zircornia infrastructure and porcelain build-up based on convenient self hygiene design. Through serial treatment, inappropriate soft tissue response is not observed and satisfactory result in functional aspect comes out.

A Study on The Dental field of Present Health Insurance for custom-made Prosthetic implant by Dental technicians (건강보험 급여화 관련 치과임플란트보철물 제작실태 연구)

  • Lee, Heekyung;Cho, Mihyang
    • Journal of Technologic Dentistry
    • /
    • v.38 no.1
    • /
    • pp.9-22
    • /
    • 2016
  • Purpose: The Purpose of this study are to describe the Dental field of present health insurance for custom-made prosthetic implant by dental technicians' work. Results: A total of 300 dental technicians working at dental laboratories in Korea were randomly selected and surveyed, 206(68.7%) of them were used for the statistical analysis. Conclusion: Average daily working time was 10 hours 66%. The average cumulative credit of the clinic for dental prosthesis fabrication rates was Less than 10 million won(21.8%), 10~80 million won(11.7%), more than one hundred million won(1.5%). Remake dental prosthesis was one more than the monthly average of 98.5%. Causes of remake dental prosthesis was dentist impression 83% but did not pay 62.5%. Dental technicians Implant production period was 7 days(48.5%), 10 days(35%) was commissioned by dentists production time is 5 days(46.1%), 7 days(36.5%). President of dental laboratories 3.86 points and dental technicians 3.06 points knew differently about starting of implant health insurance coverage(p<.001). They alike were in favor of insurance coverage for the implant. Dental technicians were lower by 2.36 points for work do you know whether your health insurance application of dental prostheses. Dental technicians are 2.16 points on whether confidence in the pores payment of insurance coverage dental prosthesis, dental laboratory president was lower by 1.85 points. They are very low with 1.97 points on whether confidence in the rate payment of health insurance coverage dental prosthesis(p<.01). The implant prosthesis abutment selected, the abutments designed, design of the implant upper prosthetic, the upper prosthetic fitting dental technicians participate of dental laboratory president showed higher score (p <.05). Conclusion: Hours of dental technicians were making this short period of remake dental prosthesis-related dental prosthesis. Dental clinic and a detailed representation of the dental prosthodontic fabrication request is required for communication between the laboratory in order to reduce the remake of a dental prosthesis, dental insurance coverage written dental prosthodontic fabrication request should be legislated. Implant classification standard medical practice 1-3 Step conduct a thorough costing a total of no. 73 of the correct classification standard medical practice in addition to eight times defined by the act of dental technicians should be defined.

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

Efficient Merging of Range Images to Reduce Dental Treatment Time (치과 치료 기간 단축을 위한 효율적인 거리 영상 융합 방법)

  • Kye, Heewon
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.179-187
    • /
    • 2017
  • The fourth industrial revolution is a phenomenon where productivity is improved in each field by the convergence of IT technology and existing industries. In the dental treatment process, prosthetic treatment time is drastically shortened through AI and expert software. Oral imaging, prosthesis design, and prosthesis manufacturing are performed continuously, so the treatment can be completed in a few hours. In this paper, we introduce the research trend of multimedia technology in the prosthetic process. We also propose a new method for accelerating the fusion of surface data during the optical impression. Proposed method enables high-speed optical impression and accelerates the overall automated production process of dental prosthesis.

Chair-side CAD/CAM fabrication of a single-retainer resin bonded fixed dental prosthesis: a case report

  • Jurado, Carlos Alberto;Tsujimoto, Akimasa;Watanabe, Hidehiko;Villalobos-Tinoco, Jose;Garaicoa, Jorge Luis;Markham, Mark David;Barkmeier, Wayne Walter;Latta, Mark Andrew
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.15.1-15.7
    • /
    • 2020
  • This clinical report describes designing and fabricating a single-retainer resin-bonded fixed dental prosthesis with a chair-side computer-aided design/computer-aided manufacturing system. The whole procedure, from tooth extraction to final placement of the prosthesis, was completed in one day, and a single clinic visit. No clinical complications were found at the 2-year follow-up after placement of the restoration, and satisfactory functional and esthetic results were achieved.

Effect of the Sprue Design on the Fitness of Implant Prosthesis (주입선의 설계가 임플란트 보철물의 적합도에 미치는 영향)

  • Hwang, Sung-Taek;Ahn, Jae-Seok;Shin, Sang-Wan
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.57-63
    • /
    • 2008
  • Statement of problem: Conventional techniques for implant framework fabrication produce significant error that is inconsistent with passive-fit requirement for osseointegrated implants. One of the etiologic factors which cause the errors is a sprue which may deform the framework during solidification and contraction. Purpose: This study was aimed to evaluate objectively effect of the sprue design on the accuracy of fit of implant prosthesis. Materials and method: Three different designs were considered relative to effect of casting accuracy. The first design had straight sprues and a button of excess alloy at the non-casting end of the sprues. The second was runner bar design(with the button). The last was straight sprues design(without the button). Gold cylinder and laboratory analogue had been used to diminish variables affecting to casting accuracy. Gold alloy and pressure-vacuum casting machine had been used. Marginal gap had been measured by SEM. One-way ANOVA and Duncan test had been used for statistical analysis. Results: The first design showed $79.87{\pm}13.95{\mu}m$ marginal gap. The second and third were $40.17{\pm}15.8{\mu}m$ and $35.17{\pm}9.95{\mu}m$ respectively. Conclusion: Straight sprues without button and runner bar designs were more accurate than straight sprues with button design(P<.05).

  • PDF

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS (3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구)

  • Byun, Sang-Ki;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis (대퇴부 거동 해석 및 복합재료 보철물 설계)

  • 임종완;하성규
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.119-130
    • /
    • 2002
  • The nonlinear finite element program has been developed to analyze the design performance of an artificial hip prosthesis and long term behavior of a treated femur with stems made of composite material after cementless total hip arthroplasty(THA). The authors developed the three dimentional FEM models of femoral bone with designed composite stem which was taken with elliptic cross section of 816 brick elements under hip contact load and muscle farce in simulating single leg stand. Using the program, density changes, stress distributions and micromotions of the material femoral bone were evaluated by changing fiber orientation of stems for selected manufacturing method such as plate cut and bend mold. The results showed that the composite materials such as AS4/PEEK and T300/976 gave less bone resorption than the metallic material such as cobalt chrome alloy, titanium alloy and stainless steal. It was found that increasing the long term stability of the prosthesis in the femur could be obtained by selecting the appropriate ply orientation and stacking sequence of composite.