• Title/Summary/Keyword: Proportional-resonant controller

Search Result 65, Processing Time 0.023 seconds

DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator (냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구)

  • Kim, Ho-Jin;Kim, Hyeong-Jin;Kim, Dong-Youn;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

Controller Design of Stand-Alone or Grid-Connected Inverter to Compensate Harmonics Caused by Nonlinear Load (비선형부하에 의해 발생하는 고조파 보상을 위한 독립형 또는 계통연계형 인버터 제어기 설계)

  • Sin, Chanho;Lim, Kyungbae;Petrus, Simatupang Desmon;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.440-448
    • /
    • 2017
  • This paper proposes a controller design of a distributed source inverter in stand-alone mode or grid-connected mode to compensate the current or voltage harmonics caused by local nonlinear load. The PR-based multi loop controller has been used to improve the dynamic performance of the system and to compensate the output voltage or grid current harmonics. The multi-loop controller consists of an outer current controller and an inner voltage controller for the output voltage control in stand-alone mode. In grid-connected mode, an outer current controller is added to the output voltage controller for the grid current control. The design performance of each controller is described through the Root locus and Bode plot of the transfer functions. The validity of the proposed control algorithm and design parameters has been verified through the PSiM simulation and experimental results.

A Comprehensive Harmonic Rejection for DFIG Feeding Non-Linear Loads in Stand-Alone Applications

  • Nguyen, Ngoc-Tung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.258-259
    • /
    • 2012
  • This paper proposes a new control strategy to eliminate the harmonic components of stator current for stand-alone DFIG system feeding non-linear loads. In this method, the LSC operates as an active filter which is controlled by employing a proportional-integral and a resonant controller. And also, the stator current is used as the feedback signal for the compensator instead of the load current, so that the additional current sensor at the load side can be removed. The experiment is verified to validate the effectiveness of the proposed compensating method.

  • PDF

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.

Research on a Multi-Objective Control Strategy for Current-source PWM Rectifiers under Unbalanced and Harmonic Grid Voltage Conditions

  • Geng, Yi-Wen;Liu, Hai-Wei;Deng, Ren-Xiong;Tian, Fang-Fang;Bai, Hao-Feng;Wang, Kai
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.171-184
    • /
    • 2018
  • Unbalanced and distorted grid voltages cause the grid side current of a current source PWM rectifier to be heavily distorted. They can also cause the DC-link current to fluctuate with a huge amplitude. In order to enhance the performance of a current-source PWM rectifier under unbalanced and harmonic grid voltage conditions, a mathematical model of a current-source PWM rectifier is established and a flexible multi-objective control strategy is proposed to control the DC-link current and grid-current. The fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic components of the grid voltage are first separated with the proposed control strategy. The grid current reference are optimized based on three objectives: 1) sinusoidal and symmetrical grid current, 2) sinusoidal grid current and elimination of the DC-current $2^{nd}$ order fluctuations, and 3) elimination of the DC-current $2^{nd}$ and $6^{th}$ order fluctuations. To avoid separation of the grid current components, a multi-frequency proportional-resonant controller is applied to control the fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic current. Finally, experimental results verify the effectiveness of proposed control strategy.

Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.469-478
    • /
    • 2013
  • This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.

The Proportional Resonant Controller for Improving the Current Distortion of the Dual buck inverter in DCM Section Connected grid system with harmonic voltage (고조파 전압이 포함된 계통과 연계된 듀얼벅 인버터의 DCM 구간에서 전류 왜곡 개선을 위한 비례공진 제어기)

  • Choi, Minjae;Cho, Younghoon;Choi, Jinuk;Moon, Youngmin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.286-287
    • /
    • 2018
  • Recently, the development of renewable energy using solar energy is drawing attention. One of these PV systems, the Dual buck Inverter, is one of the topologies used in conjunction with the system, characterized by high efficiency and shoot-through reduction. However, current distortion appears severely in grid connection. So, in this paper, the method of compensation through PR controller was verified through simulation as an analysis of current distortion components and a control method to improve them.

  • PDF

Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters

  • Han, Yang;Shen, Pan;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.297-309
    • /
    • 2016
  • Grid-connected inverters (GCIs) with an LCL output filter have the ability of attenuating high-frequency (HF) switching ripples. However, by using only grid-current control, the system is prone to resonances if it is not properly damped, and the current distortion is amplified significantly under highly distorted grid conditions. This paper proposes a synchronous reference frame equivalent proportional-integral (SRF-EPI) controller in the αβ stationary frame using the parallel virtual resistance-based active damping (PVR-AD) strategy for grid-interfaced distributed generation (DG) systems to suppress LCL resonance. Although both a proportional-resonant (PR) controller in the αβ stationary frame and a PI controller in the dq synchronous frame achieve zero steady-state error, the amplitude- and phase-frequency characteristics differ greatly from each other except for the reference tracking at the fundamental frequency. Therefore, an accurate SRF-EPI controller in the αβ stationary frame is established to achieve precise tracking accuracy. Moreover, the robustness, the harmonic rejection capability, and the influence of the control delay are investigated by the Nyquist stability criterion when the PVR-based AD method is adopted. Furthermore, grid voltage feed-forward and multiple PR controllers are integrated into the current loop to mitigate the current distortion introduced by the grid background distortion. In addition, the parameters design guidelines are presented to show the effectiveness of the proposed strategy. Finally, simulation and experimental results are provided to validate the feasibility of the proposed control approach.

A 2nd Order Harmonic Compensation Method for Wind Power System Using a PR Controller

  • Jeong, Hae-Gwang;Lee, Jong-Hyun;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.507-515
    • /
    • 2013
  • This paper proposes a compensation method for the $2^{nd}$-order harmonic of single-phase grid-connected wind power generation systems. Theoretically, a single-phase grid-connected inverter system has no choice but to cause the $2^{nd}$-order harmonic to DC-link voltage. The reference active current is affected by the DC-link voltage. The output current from the reference active current is distorted by the $1^{st}$ and $3^{rd}$-order harmonic. The proposed method can compensate, conveniently, the reference active current with the $2^{nd}$-order harmonic. To reduce the $2^{nd}$-order ripple in the reference active current, proposed method takes a PR controller as a feed-forward compensator. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulation and experimental results agree well with the theoretical analysis.