• Title/Summary/Keyword: Properties of floor

Search Result 313, Processing Time 0.034 seconds

Structural characteristics of railway vehicle floors with joints (연결체결부를 갖는 철도차량 바닥재의 구조특성)

  • Shin, Bum-Sik;Choi, Yeon-Son
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.809-815
    • /
    • 2007
  • The floor structure of railway vehicles consists of plywood, rubber, and wood keystone plate which affects on the comfort of passengers. Its structural characteristics has been investigated experimentally and numerically for samples of beam and plate structure, and the real floor structure in this paper. The material properties of etch part measured directly by experiments. The deformation and stress distribution of the sample beams for 6 different joints were sought experimentally and calculated using a commercial software. The numerical calculation shows that the effect of friction and clearance between joints is crucial. The DMU/EMU plates were also experimented and compared for different loading conditions. The structural characteristics of the whole floor structure were calculated numerically. The results show that the method of joint between plywoods is an important factor to decide the strength of the floor structure of railway vehicles.

  • PDF

The study on the dynamic characteristics of steel structure system for vibration estimation in hospital building (철골조 고층 병원건물의 진동예측을 위한 동적특성 및 설계인자에 관한 연구)

  • Jang, Kang-Seok;Kim, Young-Chan;Ahn, Sang-Kyung;Na, Woon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.458-461
    • /
    • 2008
  • The primary objective of this study is to provide simple analytical tools to estimate dynamic characteristics of steel framed floor system in hospital building for vibration serviceability due to human activities, bogie, medical equipment. and so on. In order to evaluate the dynamic characteristics and vibration levels according to steel framed floor system, we had executed impact test and measurement on steel structure floor system in various hospital buildings. But perhaps most importantly, how to make the most of deduced design factor for design of hospital building. therefore we presented the access method such as the three-dimensional F.E. numerical analysis on the basis of the design drawing, and the properties of all floors for estimation of vibration level in hospital building.

  • PDF

Study on Structural Behavior of Multi-layered Concrete Floor Structure (콘크리트 다층바닥판 구조의 구조거동에 관한 해석적 연구)

  • 유영준;송하원;변근주;정성철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.474-479
    • /
    • 1998
  • In this paper, the structural behavior of R.C. multi-layered floor structure including foam concrete layer is numerically analyzed. For the analysis, 3D interface element has been implemented to finite element analysis program to consider the interfacial behavior of multi-layered floor structure which consists of rubber layer, foam concrete layer and mortar layer on RC slab. Based on analysis results on multi-layered structure, its structural behavior is analyzed according to geometrical and material properties of foam concrete. Optimum material property of each layer of the floor structure is proposed to get optimum multi-layered concrete structure.

  • PDF

A Study on the Reduction Characteristics of Floor Impact Sound Insulation Due to the Ceiling Frame Structures in Apartment Houses (공동주택의 천장틀구조 변화에 따른 바닥충격음 차음특성 연구)

  • 정환욱;기노갑;송민정;김선우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.573-580
    • /
    • 2002
  • Generally the ceiling frame of apartment house is made of wood. But the wood frame has several problems due to the natural properties such as distortion by shrink, low fire resistance and material loss in the construction field. And it has some defections in sound insulation performance. Therefore it is necessary to develop a new method that can be used as a ceiling frame. This study aims to analyze and to compare the sound insulation characteristics against the floor impact sound between wood ceiling frame and M-bar frame which is made of steel. The results of this study are like these. M-bar frame is more effective than wood ceiling frame in sound insulation. And sound absorbing or sound insulation materials which can be Put on gypsum board are helpful to improve floor impact sound insulation performance.

Water Storage Characteristics of Surface Soil by the Different Forest Floor Conditions(II) (지피상태(地被狀態)에 따른 임지(林地)의 수저유(水貯留) 특성(特性)(II))

  • Lee, Heon Ho;Lee, Chang Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.4
    • /
    • pp.473-479
    • /
    • 1994
  • This study was carried out to get the basic data for obtaining water resources continuously. Water storage of forest land was estimated by effective water storage based on classifying soil pore. The results were summarized as follows ; 1. Percentage of coarse pores were in the order : Forest>Bare land>Grasses. As soil depth increased, total pores, coarse pores, and maximum water content were decreased, while fine pores increased. 2. Soil pore percentage and physical properties of surface layer(0~20cm) were significantly different among forest floor conditions. However, there were no difference in soil pore percentage and physical properties in 20~40cm and 40~60cm according to forest floor conditions. In the same plot, on the other hand, soil pore percentage and physical properties were significantly different between surface layer(0~20cm) and 20~40cm, but there were no differences between 20~40cm and 40~60cm. 3. Effective water storage was highly correlated with coarse pore in all plots. 4. The model for water storage capacity of each forest floor condition expressed by effective water storage was produced using coarse pores and soil depth.

  • PDF

Evaluation of Properties and Stability to use Floor Materials for Cogeneration Power Plant as Fine Aggregates for Concrete (열병합 발전소 바닥재를 콘크리트용 잔골재로 활용하기 위한 기초 물성 및 안정성 평가)

  • Kang, Suk-Pyo;Hong, Seong-Uk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.321-326
    • /
    • 2022
  • In this study, cogeneration power plants that use biomass as a raw material to convert them into energy have recently received a lot of attention worldwide and are gradually increasing in South Korea. Therefore, in order to confirm the possibility of using the generated floor material as a fine aggregate for concrete, properties and stability evaluation experiments were performed. Compared to standard sand, the compressive strength of wood chip aggregate was improved by 11 % to 111 %, the length change rate was 89 %, and the waste processing test results met all criteria for hazardous substances. All of these are satisfied, and it is judged that the floor materials by the cogeneration power plant can be used as a fine aggregate for concrete.

A Study on Properties of PVA/$SiO_2$ Organic-inorganic Hybrid Materials Barrier Layer Coated on Flexible Substrate (PEN)

  • Koo, Tae-Wook;Farva, Umme;Yu, Eric S.H.;Kim, Yun-Su;Park, Chin-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.657-659
    • /
    • 2008
  • Barrier coating properties of PVA/$SiO_2$ on the flexible substrates (PEN) have been investigated. Thin layer of PVA/$SiO_2$ organic-inorganic hybrid materials were deposited on PEN substrate by the spin-coating. The optical properties and surface roughness of barrier layer on flexible substrate were characterized by AFM, UV-Vis and WVTR/ OTR.

  • PDF

Probability Based Determination of Slab Thickness Satisfying Floor Vibration Criteria (수직진동 사용성 기준을 고려한 바닥판 두께 제안)

  • Lee Min-Jung;Nam Sang-Wook;Han Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.687-694
    • /
    • 2005
  • In current design practice, the thickness of the floor slab has been determined to satisfy requirement for deflection control. However, previous study shows that the floor thicknesses in residential buildings may not satisfy the floor vibration criteria, even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. This study attempts to propose slab thickness for flat plate slab systems that satisfies floor vibration criteria against occupant induced floor vibration(heel drop load). Two boundary conditions(simple and fixed support), three square flat plates(4, 6, 8m), and five concrete strength($18\~30$ MPa) are considered. Since there are large uncertainties in loading and material properties, probabilistic approach is adopted using Monte-Carlo simulation procedures.

Influences of Doping Methods on Microstructure and Fracture Toughness of Mo-La Alloys

  • Wang, Lin;Sun, Yuanjun;Luo, Jianhai;Zhu, Yongan;Niu, Pingwen
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1327-1328
    • /
    • 2006
  • Lanthanum oxide was introduced to molybdenum powder by liquid-liquid doping and liquid-solid doping respectively. Mo alloys were prepared by powder metallurgy technology. The size distribution and feature of dopant particles and the fractographs of Mo alloys were investigated by TEM and SEM respectively. The results indicated that liquid-liquid doping method is favorable for refining and dispersing $La_2O_3$ particles uniformly in matrix. Fracture toughness of Mo alloys prepared by liquid-liquid doping showed better results than that of liquid-solid doping. Furthermore, the influences of the size distribution of $La_2O_3$ on properties of Mo alloys was discussed by dislocation pile-up theory.

  • PDF

Preparation and Quality Evaluation of Kimchi using Mineral Water in Sea Rock (천연 해저 암반수 김치의 제조 및 품질 평가)

  • Hahn Young-Sook
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.1
    • /
    • pp.119-125
    • /
    • 2005
  • A kind of mineral water obtained from the basing of deep under the sea was reported to have a characteristic mineral composition and its effect on the quality of Kimchi was evaluated in this study. Kimchi samples were prepared with NaCl and the mineral water under rock floor as sources of salt together with fermented seafoods and fermented at 20 for 6 days. The qualities of Kimchi were evaluated by analyzing the pH, acidity, number of viable cell, lactic acid bacteria, sensory properties and texture profiles during fermentation. The pH and total acid contents were not different among Kimchi samples. The microbiological changes were not observed in the samples. The sensory scores of Kimchi containing NaCI and fermented sandlance sauce, and of Kimchi containing the mineral water under sea rock floor with fermented seafoods were significantly higher than those of the others. On the other hand, Kimchis prepared with NaCl alone or mineral water under sea rock floor alone earned the lowest sensory scores among the tested samples with an exception of firmness of the sample made with the mineral water. As the Kimchi fermentation proceeds, the hardness value of Kimchi prepared with the mineral water became higher than that of Kimchi with NaCl. This study suggests that the mineral water under sea rock floor could be useful to keep the texture of Kimchi firm during the fermentation.

  • PDF