• 제목/요약/키워드: Proper posterior

검색결과 175건 처리시간 0.022초

Implant 보철물 access hole의 깊이에 관한 연구 (RELALTIONSHIP BETWEEN THE DEPTH ACCESS HOLE AND PROSTHETIC COMPONENTS IN SCREW RETAINED IMPLANTS)

  • 고석민;변태희;이재봉
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.374-385
    • /
    • 2002
  • A total of 605 implant fixture prosthesis delivered by 3 clinics and 2 laboratories were examined in this study, The object of this study was to determine the proper length of screw head. The depth of access hole were measured and compared to the type of fixture, abutment, gold screw and prosthesis. The results were as follows : 1 The average number of fixtures per patient were 2.97. 2. The number of fixture installed in the upper posterior area are 327(55.56 %), the upper posterior area 171 (28.25%). 3. The depth of access hole is 4.23 mm in shallow area, and 5.46 mm in deep area and the differences were 1.23 mm. 4. The average depth of the aceess hole of the UCLA abutment were 5.02 mm. 5. The number of 4-5 mm access hole depth were 60(22.39%) in abutment screw level and the number of 4-5 mm depth in fixture level were 101 (29.19%). 6. In the shape of screw head, hexed type were 576(95.21%), slotted type were 29(4.79%).

생강(生薑) 삼편(三片)과 대조(大棗) 이매(二枚)의 사용에 대한 고찰(考察) (방약합편(方藥合編)을 중심으로) (on Applying 3 Slices of Zingiber officinale Roscoe And 2 Pieces of Zizyphus jujuba Mill. (Mainly Oriented Bangyakhappyun))

  • 임영환;국윤범
    • 대한한의학방제학회지
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 3 Slices of Zingiber officinale and 2 pieces of Zizyphus jujuba in BangYakHapPyun play a proper role in herbal prescription. Zingiber officinal is roled in protection force(衛) and Zizyphus jujuba is roled in management force(營). 3 Slices of Zingiber officinal and 2 pieces of Zizyphus jujuba in upper location of BangYakHapPyun harmonize management and protection forces(營衛氣). 3 Slices of Zingiber officinale and 2 pieces of Zizyphus jujuba in middle and lower location of BangYakHapPyun compromise and treat inner and outer body condition. 5 or 7 Slices of Zingiber officinale purge noxious vapor and alleviate Pinellia ternata(半夏). Arisaema amurense (南星) poison. Todays, 3-Yangs and 2- Yins an apriority world(先天). use 3 Slices of Zingiber officinale and 2 pieces of Zizyphus jujuba. In the future. 2-Yangs and 3-Yins in a posterior world(後天) may use 2 Slices of Zingiber officinale and 3 pieces of Zizyphus jujuba.

  • PDF

Can Myofascial Release Techniques Reduce Stress Hormones in the Subject of Short Hamstring Syndrome? A Pilot Study

  • Cho, Sunghak
    • 국제물리치료학회지
    • /
    • 제11권4호
    • /
    • pp.2237-2243
    • /
    • 2020
  • Background: The myofascial release technique is known to be an effective technique for increasing posterior fascia flexibility in short hamstring syndrome (SHS) subjects. But therapeutic mechanism of myofascial relaxation remains unclear. Recently, the theory of autonomic nervous system domination has been raised, however, a proper study to test the theory has not been conducted. Objectives: To investigate whether the application of the myofascial release technique can induce changes in the autonomic nervous system and affect the secretion of stress hormones and myofascial relaxation. Design: Quasi-experimental study. Methods: Twenty-four subjects with SHS were randomly divided into two groups. In the experimental group, the suboccipital muscle inhibition (SMI) technique was applied to the subjects for 4 min in supine position, and in the control group, the subjects were lying in the supine position only. A forward flexion distance (FFD) was conducted, blood pressure, heart rate, and cortisol levels were measured before and after the intervention and 30 min after intervention to determine myofascial relaxation and stress hormone levels. The evaluation was conducted separately in blind by an evaluator. Results: A FFD decreased in the experimental group, no change in cortisol was observed. On the contrary, a decrease in cortisol appeared in the control group after 30 minutes. Conclusion: The myofascial release technique is an effective treatment to increase the range of motion through posterior superior myofascial chain, but there is no evidence that myofascial release technique can control the autonomic nervous system.

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

  • Lee, Eunjee;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.14-21
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS. The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS. The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anterior-posterior direction of dislodging force (P <.05). CONCLUSION. Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.

엇갈린 교합 환자의 임플란트 지지 고정성 보철물과 Kennedy class IV 가철성 국소의치를 이용한 수복 증례 (Rehabilitation of a patient with crossed occlusion using mandibular implant-supported fixed and maxillary Kennedy class IV removable dental prostheses: A case report)

  • 강석형;한중석;김성훈;윤형인;여인성
    • 대한치과의사협회지
    • /
    • 제55권12호
    • /
    • pp.842-849
    • /
    • 2017
  • The term, 'crossed occlusion' implies clinical situation in which the residual teeth in one arch have no contact with those in the antagonistic arch, resulting in the collapse of occlusal vertical dimension. The treatment goal of this pathologic condition is restoration of the collapsed vertical dimension and stabilization of abnormal mandibular position. Previously, konus removable prostheses or tooth supported overdentures were suggested to solve crossed occlusion. Nowadays, dental implants have been used for definitive support to solve this problem. In this case report, a 65 years old female patient had a crossed occlusion, in which the maxillary posterior residual teeth and mandibular anterior residual teeth cross. Interim removable and fixed dental prostheses were used to confirm the proper vertical and horizontal jaw relation. After that, the mandibular posterior edentulous region was restored with implant-supported fixed dental prostheses. Computer tomography guided implant surgery was performed according to the concept of the restoration-driven implant placement. The maxillary anterior edentulous region was restored with Kennedy class IV removable prosthesis, considering the patient's economic status. The patient's jaw position and prostheses have been well maintained at the follow-up after 6 months of definitive restoration. The antero-posterior crossed occlusion problems appeared to be effectively solved with the combination of removable in one arch and implant-supported fixed prostheses in the other.

  • PDF

앙상블 칼만 필터 기반 탄소추적시스템의 아시아 지역 탄소 순환 진단에의 적용 (Application of Carbon Tracking System based on Ensemble Kalman Filter on the Diagnosis of Carbon Cycle in Asia)

  • 김진웅;김현미;조천호
    • 대기
    • /
    • 제22권4호
    • /
    • pp.415-427
    • /
    • 2012
  • $CO_2$ is the most important trace gas related to climate change. Therefore, understanding surface carbon sources and sinks is important when seeking to estimate the impact of $CO_2$ on the environment and climate. CarbonTracker, developed by NOAA, is an inverse modeling system that estimates surface carbon fluxes using an ensemble Kalman filter with atmospheric $CO_2$ measurements as a constraint. In this study, to investigate the capability of CarbonTracker as an analysis tool for estimating surface carbon fluxes in Asia, an experiment with a nesting domain centered in Asia is performed. In general, the results show that setting a nesting domain centered in Asia region enables detailed estimations of surface carbon fluxes in Asia. From a rank histogram, the prior ensemble spread verified at observational sites located in Asia is well represented with a relatively flat rank histogram. The posterior flux in the Eurasian Boreal and Eurasian Temperate regions is well analyzed with proper seasonal cycles and amplitudes. On the other hand, in tropical regions of Asia, the posterior flux does not differ greatly from the prior flux due to fewer $CO_2$ observations. The root mean square error of the model $CO_2$ calculated by the posterior flux is less than the model $CO_2$ calculated by the prior flux, implying that CarbonTracker based on the ensemble Kalman filter works appropriately for the Asia region.

Sustantial Observation on Foot Taeyang Meridian Muscle in Human Lower Limb from a Anatomical Viewpoint

  • Park, Kyoung-Sik
    • 대한약침학회지
    • /
    • 제12권2호
    • /
    • pp.21-29
    • /
    • 2009
  • Objective : This study was carried to identify the anatomical component of FTMM(Foot Taeyang Meridian Muscle) in human lower limb, and further to help the accurate application to real acupuncture. Methods : FTM at the surface of the lower limb was labelled with latex. And cadaver was stripped off to demonstrate muscles, nerves and the others and to display the internal structures of FTMM, being divided into outer, middle, and inner layer. Results : FTMM in human lower limb is composed of muscles, nerves, ligaments etc. The internal composition of the FTMM in human lower limb are as follows : 1) Muscle : Gluteus maximus. biceps femoris, semitendinosus, gastrocnemius, triceps calf, fibularis brevis tendon, superior peroneal retinacula, calcaneofibular ligament, inferior extensor retinaculum, abductor digiti minimi, sheath of flexor tendon at outer layer, biceps femoris, semimembranosus, plantaris, soleus, posterior tibialis, fibularis brevis, extensor digitorum brevis, flexor digiti minimi at middle layer, and for the last time semimembranosus, adductor magnus, plantaris, popliteus, posterior tibialis, flexor hallucis longus, dorsal calcaneocuboidal ligament at inner layer. 2) Nerve : Inferior cluneal nerve, posterior femoral cutaneous n., sural cutaneous n., proper plantar branch of lateral plantar n. at outer layer, sciatic nerve, common peroneal n., medial sural cutaneous n., tibial n. at middle layer, and for the last time tibial nerve, flexor hallucis longus branch of tibial n. at inner layer. Conclusions : This study proves comparative differences from already established studies from the viewpoint of constituent elements of FTMM in the lower limb, and also in the aspect of substantial assay method. We can guess that there are conceptional differences between terms (that is, nerves which control muscles of FTMM and those which pass near by FTMM) in human anatomy.

퇴행성 요추 질환에서 후방경유 추체간 유합술과 360° 고정술의 비교 (Posterior Lumbar Interbody Fusion Versus 360° Fixation in Degenerative Lumbar Diseases)

  • 이녹영;오성훈;이우택;배재성;이형중;김영수;고용;김광명;오석전
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1193-1199
    • /
    • 2001
  • Objectives : The goal of operation for degenerative lumbar diseases is to relieve radiculopathy and low back pain and to prevent further degeneration. The authors analyzed the surgical results of posterior lumbar interbody fusion(PLIF) and $0^{\circ}$ fixation to evaluate the proper treatment policy in spinal stenosis, degenerative spondylolisthesis and low grade isthmic spondylolisthesis. Material and Methods : The authors performed PLIF on 92 patients and $0^{\circ}$ fixation on 138 patients with spinal stenosis, degenerative spondylolisthesis and low grade isthmic spondylolisthesis. We retrospectively studied clinical outcomes and subjective satisfaction of these patients by several criteria such as visual analog scale(VAS), Prolo's economic and functional outcome scale, medication usage after operation and questionaire for overall outcome. Result : Pre- and postoperative VAS on back pain and leg pain showed decrease of pain from 6.5, 6.7 to 2.2, 2.4 in PLIF group and from 7.0, 7.2 to 2.5, 2.7 in $0^{\circ}$ fixation group. Excellent and good outcomes on Prolo's scale were 81.5% in PLIF group and 82.6% in $0^{\circ}$ fixation group. Medication usage after operation was reduced in 79.3% of PLIF group and in 78.3% of $0^{\circ}$ fixation group. Patients' self-reported overall success of their procedure showed 82% in PLIF group and 84% in $0^{\circ}$ fixation group. Conclusion : Both PLIF and $0^{\circ}$ fixation showed good outcomes and provided biomechanically stable fusion in spinal stenosis, degenerative spondylolisthesis and low grade isthmic spondylolisthesis. Therefore, only PLIF seems necessary and considered a proper surgical treatment for these disorders.

  • PDF

성장기 아동의 single tooth scissors bite의 교정 치료: 증례 보고 (ORTHODONTIC TREATMENT OF SINGLE TOOTH SCISSORS BITE IN GROWING CHILDREN: CASE REPORTS)

  • 김지인;현홍근;김영재;김정욱;장기택;이상훈;한세현;김종철
    • 대한소아치과학회지
    • /
    • 제38권4호
    • /
    • pp.427-434
    • /
    • 2011
  • 중심교합위의 상태에서 편측 혹은 양측으로 상악 구치부의 치아가 하악 구치부의 협측으로 위치한 경우를 scissors bite라고 한다. 이는 상악의 폭경이 크거나 하악의 폭경이 좁은 경우 발생한다. Scissors bite의 경우 방치하게 되면 하악의 성장이 방해받게 되고 그 결과, 악궁 폭경의 부조화가 심해져 저작 장애를 일으킬 수 있으므로 조기 차단 교정이 반드시 필요하다. 실제 임상에서는 여러 치아의 scissors bite보다 최후방 구치 혹은 그 외 하나의 구치만의 single tooth scissors bite(STSB)을 보이는 경우가 많다. 이러한 STSB의 경우도 방치하게 되면 저작력으로 인하여 구치의 각도가 더욱 악화되므로 즉각적인 치료가 필요하다. 본 증례에서는 STSB를 보이는 7세, 14세, 12세, 16세의 환자에게 각각 criss-cross elastic, 고정성 장치, 가철성 장치, miniscrew를 사용하여 치료한 증례를 보고하였다. 각 환자의 증례에 적합한 장치를 잘 선택하여 사용한다면 치아를 정출시키는 등의 부작용을 야기하지 않고 양호한 결과를 얻을 수 있을 것이다.

III급 부정교합 환자에서 상악 가철성 국소 의치와 하악 임플란트 지지 고정성 보철물을 이용한 구강 회복 증례 (Rehabilitation of posterior support and vertical dimension in a class 3 malocclusion patient: A case report)

  • 오지환;표세욱;장재승;김선재
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.175-186
    • /
    • 2022
  • 상, 하악에 잔존 치아가 있음에도 불구하고 교합 접촉이 가능한 대합 치아가 없어서 교두 감합위를 상실하게 되는 엇갈린 교합은 결과적으로 수직 고경의 붕괴를 초래한다. 본 증례에서는 엇갈린 교합 및 전치부 반대교합을 동반하는 III급 부정교합 환자를 상악 가철성 국소 의치와 하악 임플란트 지지 고정성 보철물을 이용하여 구강 회복을 진행하였다. 3개월 동안 임시의치의 착용 기간을 거쳐 수직 고경 안정화 및 심미성 개선을 위한 임시 보철물을 제작하였고, 이를 최종 수복물에 반영하기 위하여 전방 유도 테이블의 제작과 수직 고경 및 교합 관계의 유지를 위한 교차 마운팅을 시행하였다. 하악 임플란트 및 상악의 지대치는 금속 도재관을 이용하여 수복하였고, 상악의 편측성 무치악 부위는 국소 의치를 제작하였다. 단계적인 치료 과정을 통해 구치부의 적절한 지지 및 전치부의 반대교합의 해소를 통한 상호보호교합의 교합관계를 형성하였으며, 환자에게 심미적, 기능적인 치과 보철물을 장착함으로써 만족스러운 치료결과를 얻을 수 있었다.