• 제목/요약/키워드: Propane-Air

검색결과 192건 처리시간 0.024초

정적 연소실에서 성층화된 혼합기 조건하의 점화 전극사이 당량비 측정과 연소 특성에 미치는 영향 (Measurements of Equivalence Ratio in the Spark Plug Gap and Its-Effects on Combustion Under Stratified Mixture Conditions in a Constant Volume Chamber)

  • 배상수;이기철;민경덕
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1311-1317
    • /
    • 2001
  • To investigate only the effects of the stratified mixture distribution on initial flame propagation and combustion characteristics, the instantaneous equivalence ratio in the spark plug gap and combustion pressure were measured simultaneously In a constant volume chamber, To induce the stratified propane-air mixture distribution near the spark plug, counter-flow typed mixture injection system was used under the constant mean equivalence ratio $\Phi$$\_$mean/= 1.0 The instantaneous equivalence ratio was measured by a single-shot Raman scattering with narrow-band KrF excimer laser. The measuring error was within the limit of $\pm$ 3.5% provided that the proposed method was applied to the measured Raman signals. Judging from mass fraction burned derived from the measured pressure, the optimum combustion characteristics were shown under the condition that the local equivalence ratio in the spark plug was near 1.28$\pm$0.04, and these characteristics were more remarkable at the initial stage of combustion.

영상처리에 의한 화염 발광 라디칼의 가시화 (Visualization of luminescent radicals in the flame by image processing)

  • 김경찬;김영민;정주영;김태권
    • 한국광학회지
    • /
    • 제9권4호
    • /
    • pp.264-269
    • /
    • 1998
  • 분젠버너에서 당량비에 따른 연료부족, 적정, 과잉의 경우로 예혼합된 프로판-공기 화염에서 발생된 C2, CH, OH 라디칼의 농도형태 측정을 영상처리법을 이용하여 가시화하였다. 영상처리 시스템에서 협대역 통과필터, 영상증폭장치, CCD 및 PC를 사용하여 라디칼의 발광 파장대의 영상을 처리하였다. 영상처리 시스템을 통하여 화염에서 라디칼의 반응영역을 관찰하고, 라디칼의 농도분도를 예측할 수 있었다. 반응영역에서 각각의 라디칼의 공간적 분포는 CmHn 계열 화염의 반응 메카니즘을 이해할 수 있는 충분한 정보를 제공하였다. 이 정보로부터 C2 라디칼의 형광은 반응영역 앞부분에 먼저 나타나며 CH와 OH 라디칼의 형광은 화염의 하류부분에 분포함을 알 수 있었다.

  • PDF

초고압수를 이용한 노면표시 자동제거 장비개발을 위한 제어시스템 및 노면최적조건에 대한 연구 (DEVELOPMENT OF A CONTROL SYSTEM FOR AN AUTOMATIC ROAD SIGN REMOVING EQUIPMENT USING HIGH PRESSURE WATER-JET)

  • 권순욱;김균태;한재구
    • 한국건설관리학회논문집
    • /
    • 제5권4호
    • /
    • pp.139-146
    • /
    • 2004
  • Resent removal work for road signs has been labor intensive and required times since it has been done manually using shaving type equipment. While traditional process is conducting, there are traffic jams caused by the passing control, and happened unexpected accidents to workers working at dangerous road circumstance. Besides, in current shaving method, there are high potentialities on the air pollution as well as the explosive accident occurred by using a propane gas. So, as an alternative, we have studied to develop the automatic erasing equipment made up with a high pressure water-jet system and automatic control system, mobile system; Wate-rjet system consists of an intensifier and nozzles to give a high pressure and spray on the sign, and automatic control system is composed of one axis robot using a hydraulic servo actuator controlled by a lever, And as a mobile system, a truck plays an important role for the transport of equipment and the forward movement in a removal process. In this paper, we have analyzed the characteristics of road signs and have investigated current erasing methods in the field. And we have organized and designed automatic erasing equipment, and we have made a basic experiment to find out the optimal spray condition as like the spray distance, spray angle and injection pressure.

고온에서의 예혼합 초소형 화염의 연소안정한계 연구 (Stability limits of premixed microflames at elevated temperatures)

  • 김기백;이경호;홍영택;권오채
    • 한국수소및신에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.158-165
    • /
    • 2006
  • In order to provide the database for designing microcombustors, the combustion characteristics of premixed methane and propane air microflames at normal and elevated temperatures and atmospheric pressure generated on a microtube were studied experimentally and computationally. The stability limits of premixed microflames and the propensity of the microflames near the stability limits were experimentally determined, while the structure of the microflame at the fuel-leanest limit was obtained using a two-dimensional CFD simulation with a reduced kinetic mechanism. For all the microflames, the stability limits were observed only in the fuel-rich region. Results also show substantial extension of stability limits with elevated temperature that is realistic condition for micro fuel processing and significant fuel dilution immediately near the tube exit due to a low Peclet number times Lewis number effect.

안전소자를 이용한 유도회로의 점화한계 개선에 관한 연구 (A Study on the Improved Ignition Limit for Inductive Circuits with Safety Components)

  • 이춘합;박민영;지승욱;김충년;이광식;심광렬
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.66-71
    • /
    • 2004
  • This paper describes that the improved effects on the ignition limit are studied by parallel safety components for propane-air 5.25vol.% mixture gas in low voltage inductive circuits. The experimental devices are used in the IEC type spark ignition test apparatus. The improved effects on the ignition limit are respectively obtained as the maximum rising rate of 650%, 1,080% by composing parallel circuits between inductance and safety components (condenser and diode) as compared with disconnecting inductance with the safety components. The more values of inductance the higher improved effects of ignition limit rise. This improving method for the ignition limit is not concerned with the safety components. Diode appears to effect greatly better than condenser. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof machines which are applied equipment and detectors used in hazardous areas but also for data for its equipment tests.

난류 화염 내에서의 매연 입자의 생성및 재연소 (Soot Formation and Combustion in Turbulent Flames)

  • 정종수;신현동;이춘식
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.962-978
    • /
    • 1989
  • 본 연구에서는 저자들이 이미 발표한 난류 화염에서의 매연 농도 분포 해석을 포함한 화염 구조 및 복사 열전달의 해석에 대한 연구와 관련하여, 난류 화염에서의 생성된 매연 입자의 재연소 속도에 관한 새로운 모델을 제시한다.구체적인 방법 으로, 난류 화염에 대한 난류 지배 방정식의 매듭(closure) 문제로서 문제가 되고 있는 난류 모델과 반응 속도 모델에 대해서는 비교적 잘 정립되어 있다고 할 수 있는 축대칭 분류 유동을 선택하여, 난류 모델과 난류 연소 속도 모델을 고정하고, 난류 화염에서의 매연 생성 및 연소 모델을 검토하였다.

냉매 R717과 R22를 작동유체로 이용한 냉동장치의 성능특성에 관한 연구 (The Study on Performance Characteristics in Refrigeration System using R717 and R22 as working fluid)

  • 김진현;김재근;김종길;김양현;홍석주;하옥남
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.495-500
    • /
    • 2006
  • Nowadays HCFCs refrigerant are restricted because it cause depletion of ozone layer. However, natural gases such as ammonia as an organic compound, propane and propylene as hydrocarbon are easy and cheap to obtain as well as environmental. Accordingly, this experiment apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 15bar to 16bar and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.

  • PDF

기포 펌프를 적용한 흡수식 열펌프용 고온 재생기의 작동 특성 실험 (Experiments on a Regenerator with Thermosyphon for Absorption Heat Pumps)

  • 박찬우;정종수;남평우
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.463-472
    • /
    • 1996
  • Experiments were carried out to study the operation characteristics of a regenerator with a thermo-syphon pump and a surface-flame burner for a lithium bromide (LiBr)-water absorption heat pump. A cylindrical-shape metal-fiber burner and commercial grade propane were used. The emission of carbon monoxide and nitric oxide was measured by a combustion gas analyzer. Ther regeneration rate of water vapor as a refrigerant was measured. It could be as a reference value showing the performance of the regenerator. The circulation rate of the LiBr-water solution was also measured from both the tanks for the weak-and the strong-solution. Using a refractometer, the LiBr concetration in the solution was calculated from the measured refractory index of the solution. Temperature of the solution and the condensed water was recorded at several points in the experimental apparatus with thermocouples, using a personal computer. This data collecting system for measuring temperature was calibrated with a set of standard thermometers. The generating rate of water vapor as refrigerant increased linearly with heat supplied. It was about 4.0g/s with the heat supplied at a rate of 16,500kcal/h. The circulation rate of LiBr solution also increases with the heat supplied. The difference in LiBr concentrations between the weak and the strong solution was in the range of 1 to 5% when the concentration of the strong solution was about 60%. It was dependent upon both the heat supplied and the circulation rate of the solution. The initial concentration and the level of the LiBr solution in the regenerator were measured and recorded before experiments. The effect of them on the generating rate of water vapor and the circulation rate of the solution was also studied. The generating rate of water vapor was not strongly dependent upon both the level of the LiBr solution and the initial LiBr concentration. However, the concentration difference of the solution increases with the initial level of the LiBr solution.

  • PDF

서울지역에서의 VOCs 오염원 기여도 추정에 관한 연구 (Estimation of Quantitative Source Contribution of VOCs in Seoul Area)

  • 봉춘근;윤중섭;황인조;김창녕;김동술
    • 한국대기환경학회지
    • /
    • 제19권4호
    • /
    • pp.387-396
    • /
    • 2003
  • A field study was conducted during the summer time of 2002 to determine compositions of volatile organic compounds (VOCs) emitted from vehicles and to develop source emission profiles that is applied to CMB model to estimate the source contribution of certain area. Source emission profile is widely used for the estimation of source contribution by the chemical mass balance model and have to be developed applicable for the target area of estimation. This study was aimed to develop source emission profile and estimation of source contribution of VOCs after application of the chemical mass balance (CMB) receptor model. After considering the emission inventory and other research results for the VOCs in Seoul, Korea, the sources like vehicle emission (tunnel), gas station (gasoline, diesel), solvent usage (painting operation, dry cleaning, graphic art), and gas fuels were selected for the major VOCs sources. Furthermore, ambient air samples were simultaneously collected from 09:00 to 11:00 for four days at eight different official air quality monitoring sites as receptors in Seoul during summer of 2001. Source samples were collected by canisters, and then about seventy volatile organic compounds were analyzed by gas chromatography with flame ionization detector (GC/FID). Based on both the developed source profiles and the database of the receptors, CMB model was intensively applied to estimate mass contribution of VOCs sources. Examining the source profile from the vehicle, the portion of alkanes of VOCs was highest, and then the portion of aromatics such toluene, m/p-xylene were followed. In case of gas fuel. they have their own components; the content of butane, propane, ethane was higher than any other component according to the fuel usage. The average of the source apportionment on VOCs for 8 sites showed that the major sources were vehicle emission and gas fuels. The vehicle emission source was revealed as having the highest contribution with an average of 49.6%, and followed by solvent with 21.3%, gas fuel with 16.1%, gasoline with 13.1%.

ASTM E681-04 표준에 따른 가연성 냉매의 희박가연한계 (Lower Flammability Limits of Flammable Refrigerants According to ASTM E681-04 Standard)

  • 박기정;우승규;정동수
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.726-734
    • /
    • 2007
  • In this study, lower flammability limits (LFLs) of three hydrocarbon refrigerants (R600a, R290, R1270) and two hydrofluorocarbon refrigerants (R152a, R32) and DME (RE170) are measured by the method proposed by ASTM E681-04 Standard. Flammability tests are carried out at three temperatures of $23^{\circ}C,\;60^{\circ}C\;and\;100^{\circ}C$ and relative humidity 50%. Test results show that the present data for isobutane and propane obtained at $23^{\circ}C$ are similar to those found in the literature, confirming indirectly the reliability of the present test method and facility. For propylene, R152a, and R32, LFLs found in the literature differ considerably. Especially, the deviation of LFL of propylene is more than 30% among the literature data. The present data for propylene, R152a, and R32 agree with either of the data sets available. As the temperature increases from $23^{\circ}C\;to\;100^{\circ}C$, LFLs of all refrigerants tested decrease. LFLs of most refrigerants tested in this study at $60^{\circ}C$ decrease by $0.1{\sim}0.3%$ as compared to those at $23^{\circ}C$. Also LFLs of most refrigerants tested in this study at $100^{\circ}C$ decrease by $0.1{\sim}0.3%$ as compared to those at $60^{\circ}C$.