• Title/Summary/Keyword: Proofing

Search Result 219, Processing Time 0.026 seconds

Study on introduction of 'Pre-Agreement system for Additional Incidental Cost' related to construction time extension (공사기간 연장에 따른 추가간접비 사전합의 제도 도입 방안 연구)

  • Jeong, Ki-Chang;Lee, Jae-Seob;Park, Yang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.33-44
    • /
    • 2012
  • This study is as to payment improvement method of additional incidental cost to be occurred upon extension of public construction time. According to the result of analysis about the cause of non-payment of additional incidental cost of construction time extension through site examples, it was found that difficulties exist in disputes & proofing over the scope of actual cost recognition, and in this regard the result of experts opinion indicated that a construction extension pre-agreement system can be executed which agrees the scope of recognition of additional incidental cost of construction time extension once the statistical standard is clear and accurate. Accordingly, in this study, by totalling multiple sites data, calculations were implemented in terms of type of construction projects, amount of constructions, period of constructions. According to the result of calculation, the element of type of construction project and construction period appears to have none direct effect to the occurrence of additional cost of construction time extension, but direct relationship was indicated related to the contract amount element. In view of above, in this study a standard additional incidental cost of construction time extension was proposed, and presented a system improvement plan to implement the construction extension pre-agreement system.

A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis (방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구)

  • Byeon, Junghwan;Choi, Sang-won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

A Study on Evaluation of Field Applicability of Flexible Waterproofing Material with High Adhesion Using Reclaimed Natural Latex (천연 라텍스 재생고무를 활용한 고점착형 시트 방수재의 현장 적용성 평가 연구)

  • Oh, Sangkeun;Jo, Ilkyu;Kim, Jinsung;Kim, Dongbum;Lee, Jongyong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.25-32
    • /
    • 2013
  • This study has been conducted in order to propose Eco-friendly and High functional waterproofing technology available for structure by verifying application and performance of water proofing material(s) in purpose of making effective use of reclaimed rubber. As s result of 12 months evaluation, stable performance for water pressure and lateral pressure of $0.3N/mm^2$ were confirmed. Also, as the time elapsed, the amount of water absorption and adhesion performance showed only a slight difference(+0.05g, $-0.1Nmm^2$) as well, which in turn confirmed that waterproofing performance remains stable. Studies show that it is expected to expand recycling technology of natural rubber by applying reclaimed rubber on construction waterproofing field, and to hold a technical superiority by using eco-friendly material in construction waterproofing market throughout active application of these types of research.

  • PDF

The Liquid Flame Proofing Agent's Permeating Effect of Wood Using Microwave (마이크로파를 이용한 목재의 액상방염약제 침투효과 연구)

  • Park, Cheul-Woo;Her, Jae-Won;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.256-264
    • /
    • 2011
  • By implementing an analysis on the liquid flame proof agent infiltration of microwave-heated wood under soaking conditions (room temperature soaking, heat soaking), its correlation with wood temperature, and the structure of wood and permeating components after soaking in flame proof agent, which was carried out as basic research in order to improve the fire resistance performance of the wood itself, it is found that the infiltration increases as the microwave heating time increases, while for heat soaking, it is found that high infiltration as well as the stable permeability of flame proof agent is achievable. Also, when the wood temperature is more than $80^{\circ}C$, the infiltration by the flame proof agent increased, and a very even infiltration of flame proof agent was observed, which implies that the liquid flame proof agent has a dependency on temperature change of the wood as a condition to penetrate into the wood. As a result of fine structure analysis, the flame proof agent transfer between cells through pits was considered as a cause to increase the infiltration of flame proof agent, and it is also shown that for heat soaking among the permeating component analysis, as the crystallized flame proof agent around the heartwood and sapwood inner pits increases, the flame proof agent can penetrate into the the heartwood part.

Studies on the Dimensional Stabilization of Wood -Especially by the Solution of Different Composition by PEG Molecular Weight- (목재(木材)의 치수 안정화(安定化)에 관(關)한 연구(硏究) -Polyethylene Glycol의 혼합액(混合液)을 중심(中心)으로-)

  • Oh, Joung Soo;Cheon, Cheol
    • Journal of Korean Society of Forest Science
    • /
    • v.76 no.2
    • /
    • pp.119-126
    • /
    • 1987
  • This study was carried out to elucidate the desirable PEG molecular weight and it's blending methods which can promote the dimensional stabilization of Corpus controversa, Quercus variabilis and Prunus sargentii. The results may be summarized as follows: 1. PEG polymer loading in woods was affected by specific gravity of wood. And the PEG polymer loading was satisfactory except in Quercus variabilis, which shows the blending method of PEG V was proper. 2. Bulking coefficiency of PEG V was high in Corpus controversa and Prunus sargentii, and it is necessary to paint or coat water-proofing wood preservative: for high bulking coefficiency of Quercus variabilis. 3. In the treatment of PEG V, the antishrink efficiency of Prunus sargentii was 82.59% and that of Quercus variabilis 62.79%. 4. Dimensional stabilization of hardwoods did not have apparant relation with PEG blending method. 5. Judging from results, PEG-400 and PEG-1000 would be enough for dimensional stabilization of hardwood having high specific gravity if other factors are considered well.

  • PDF

A study on the state of the art on the construction and the new technology of the underground structure(underpass, underground passageways) (지하구조물(지하차도, 지하통로)건설 현황 및 관련 신기술 개발동향 연구)

  • Kim, Hyung-Tae;Han, Man-Yop;Son, Yeun-Jin;Han, Rok-Hee;Jeong, Ji-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.891-894
    • /
    • 2008
  • This study was performed to investigate how to design, where to construct, why to degrade, what plan to use systematically the underground structures such as underpass, underground passageways. About 50% of the underground structures are located on Seoul, Kyungi-Do. In design of the underground structures such as underpass, underground passageways, the required conditions are defined. And also in construction stage, the conditions of soil, required structure depth, site characteristics, reasonable construction method, are investigated. In the selection of details for underground structure, the items mainly considered, are the wall and column type, the sidewalk type, anchoring-system type, the water-proofing method, entranc shape. The reason and the adequate measures for the degradation of concrete structure are also investigated. The initial cracking properties due to the thermal characteristic are considered. The state of the art report on the new technologies are reviewed. The recent project for the systematically application to the underground structures is reviewed.

  • PDF

An analysis of the properties of mortar according to the change of the replacement rate of waste foundry sands (폐주물사의 치환율 변화에 따른 모르타르의 특성 분석)

  • Ryu, Hyun-Gi;Kwon, Yong-Ju
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.99-104
    • /
    • 2009
  • For recycling of waste foundry sands, researchers recently try to recycle them rather than depend on reclamation, and are studying on how to combine waste foundry sands with cement and use them for various kinds of construction material as the effective recycling method of waste foundry sand. In this research, The ways to find the proper replacement rate of waste foundry sands and to make use of them were suggested through the experiments on the range to apply waste foundry sands with two levels of 1:3 mixture rate of W/C 43% and 50%. The research result showed that in terms of liquidity as the characteristic of unhardened mortar, as the replacement rate of waste foundry sands increased, its flow tended to decrease. The amount of air also displayed a similar tendency to that of liquidity in that the higher the replacement rate of waste foundry sands became, the lower it became. With regard to the solidity trait of hardened mortar, it increased when the waste foundry sands were replaced more, and the replacement of waste foundry sands caused increased initial solidity. As for the amount of water permeated and that of water absorbed as the water tight proofing properties, the amount of permeated water was proved to decrease because of the gap recharge effect by the fine powder of waste foundry sands, and the replacement of waste foundry sands in the structures requiring watertightness is concluded to be very effective.

  • PDF

The Correlations among the Categorized Quality Cost Factors on SMEs (Small & Medium-sized Enterprises) (중소 제조기업의 품질비용 행태에 관한 실증 연구)

  • Lee, Sang-Choon;Koo, Il-Seob
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.731-746
    • /
    • 2011
  • The successful and sustainable growth of SMEs depends on their ability of strengthen their competitiveness in quality and cost and service more than anything else as a fundamental of operation. Among these key competitive factors of SMEs, quality is the most critical factor in manufacturing business fields. Because quality strongly influence cost and service performance on this manufacturing business field. There are many different ways to improve the quality performance but it needs proper management decision to choose the best way what can maximize outputs with minimum inputs. And it needs effective measurement methods and some indicators to analysis the quality performance properly. The quality cost is one of the simplest key indicators to measure the quality performance and the effectiveness of quality related management decisions. The major purpose of this study is to diagnose the categorized current level of actual quality cost of local SMEs to maximize their quality management effectiveness through comparing their level with others what's expressed in early studies. In this study, through survey on local SMEs, we found that their average annual quality cost ratio versus turnover - Total amount of annual quality cost divided by annual turnover - is around 3.69% excluded some SME's performances what have different quality control measures with others. And we found some results what corresponded with the early studies on the correlations between those categorized quality costs factors and some discrepancies between some of the literature model and the early case study results as follows. There were negative correlations between the Prevention costs and the External failure costs, and the Appraisal costs and the External failure costs, and there was positive correlation between the Appraisal costs and Internal failure costs same as early studies. But, we couldn't found any strong negative correlations between the Cost of control - Preventive costs & Appraisal costs - and the Cost of Failure of control - Internal & External failure costs -. It reveals not only the lack of effectiveness on their preventive or appraisal activities but also it can reveal there were so many effective ways to prevent the failure costs properly such as some innovative investment on Factory automation includes Error Proofing and more preventive actions to improve the effectiveness of the typical management methods likes CE (Concurrent Engineering), APQP (Advanced Product Quality Planning), FMEA (Failure Mode & Effect Analysis) etc.

  • PDF

A Study on the Securing Technological Safety of Mobile Electronic Notification Service in Public and Administrative Agencies (공공·행정기관 모바일전자고지서비스의 기술적인 안전성 확보 방안에 대한 연구)

  • Kim, Jong-Bae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.7-16
    • /
    • 2020
  • The mobile electronic notification service delivers notifications through mobile phone text or app-based message push to solve various problems of the paper-based mail service. And it is a service that an electronic document relay company proves to prove delivery. In order for public and administrative agencies to provide mobile electronic notification service, the user's identification information of the mobile phone number or the subscribed app is required. To overcome these limitations, ICT-regulated sandbox system was used to allow collective conversion of users' resident registration numbers into connecting information (CI). Therefore, in this paper, we propose a technical method for safe management of user CI in mobile electronic notice service, identity verification of electronic notice readers, and prevention of forgery and forgery of electronic notices. Through the proposed method, it is confirmed that the service can be activated by minimizing the adverse function of the mobile electronic notification service by securing the user's convenience and technical safety for the CI.

Commercial Wheat Flour Quality and Bread Making Conditions for Korean-style Steamed Bread (한국형 찐빵 제조에 적합한 시판 밀가루 품질 밑 적정 제빵 조건)

  • 김창순;황철명;송양순;김혁일;정동진;한재홍
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.6
    • /
    • pp.1120-1128
    • /
    • 2001
  • This study was to investigate the flour quality and bread making condition required for Korean-style steamed bread, using 5 commercial wheat flours (protein content from 8.2 to 12.5%), They were compared in making steamed bread (SB) and baked roll bread (BRB). Straight dough method was used and the temperatures of dough and fermentation were controlled at 26$^{\circ}C$ and 32$^{\circ}C$, respectively. The first fermentation was conducted at various times (0, 20, 40 and 60 min) and then forty min of proofing (2nd fermentation) was used for all bread dough. As the 1st fermentation time increased, volumes of both SB and BRB increased 4.3 ~8.7% and 27~40%, respectively, but the SB flattened and the total bread scores of SB decreased due to the lack of smoothness and shininess of the bread surface and poor grain. Contrary to that, the total bread scores of BRB increased. SB made from the flour containing 10.5% of protein, was of its highest quality: relatively high volume, smooth, semiglossy and white surface, good texture, followed by SB made from flours containing 10.9%, 9.5%, 12.5%, and 8.2% of protein content, respectively These results suggest that the 1st fermentation process was not needed for SB making. Total bread scores of SB were better correlated with farinograph dough stability than protein contents and volumes of SB were correlated with farinograph development time. Therefore, in steamed bread making, flour dough rheology is important as well as protein content.

  • PDF