• Title/Summary/Keyword: Prompt L-Pop

Search Result 48, Processing Time 0.022 seconds

THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS (All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향)

  • Son, Sung-Ae;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

INFLUENCE OF MULTIPLE ADHESIVE COATINGS ON THE SHEAR BONDING STRENGTH OF COMPOSITE RESIN (접착제의 다층적용이 복합레진의 전단결합강도에 미치는 영향)

  • Park, Heon-Dong;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.377-387
    • /
    • 2006
  • The objective of this study was to evaluate the influence of multiple adhesive coatings on the thickness of hybrid and adhesive layer and shear bond strength(SBS) of self-etch adhesives and self-etch primer adhesives. The buccal or lingual crown dentin of extracted human molars was used. Self-etch adhesives or self-etch primer adhesives were applied 1, 2 and 3 times on the dentin before light curing. In another group adhesives were reapplied after light curing first layer. Treated surfaces were prepared to measure the thickness of hybrid and adhesive layer with SEM, and shear bond strength to dentin using an Instron machine. The following results were obtained : 1. The adhesive layers increased with the number of coatings(p<0.05) with all adhesives. Adpor Prompt L-Pop and Xeno III were significantly thinner than self-etch primer adhesives (p<0.05). 2. The thickness of hybrid layers increased with the number of coatings (p<0.05). 3. The shear bonding strength of Unifil Bond and Clearfill SE Bond were higher than Scotchbond Multipurpose Plus and Adpor Prompt L-Pop (p<0.05), and similar with Xeno III. 4. The shear bond strength increased significantly with the number of coatings in Adpor Prompt L-Pop(p<0.05), but decreased at 3 times in AdheSE Bond(p>0.05). 5. In Adpor Prompt L-Pop and Xeno III, the shear bond strength decreased when adhesives were reapplied after curing the first adhesive layer.

  • PDF

The Effect of Aging Treatment for Microleakage within Composite Resin Restoration (시효처리가 복합레진 수복물의 미세누출에 미치는 영향에 관한 연구)

  • Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.283-295
    • /
    • 2013
  • In this study, researchers tried to find the effect, if any, of aging treatment to the specimens with three different dentin bonding agents using MicroCT. One, 5th generation - [Adper$^{TM}$ Single bond Plus] and two 6th generation [AdheSE$^{(R)}$, Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$] dentin bonding agents were used in this study. Specimens were divided into 4 groups according to aging treatment method used. Group I : control group, Group II : thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 60 seconds dwell time 5,000 times, Group III : aged as Group II and artificially brushed 20,000 times, Group IV : aged as Group III and were stored in artificial saliva for 6 months. With Single bond Plus, Group II showed more microleakage than Group I (p < 0.05). Group II and Group III showed more microleakage than Group IV (p < 0.05). There were no statistically significant differences among the groups using AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ (p > 0.05). Among Group I, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group II, there were no statistically significant differences (p > 0.05). Among Group III, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group IV, AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ showed more microleakage than Single bond Plus (p < 0.05).

The Study of the Effect of Thermocycling on Microleakage within Various Dentin Bonding Agents (열순환이 상아질접착제 처리 후 미세누출에 미치는 영향에 관한 연구)

  • Yoo, Seung-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.147-155
    • /
    • 2008
  • Three groups of dentin bonding agents (5th generation Single Bond 2.0 and two 6the generation Prompt L-Pop, AdheSE) applied to class V cavities (upper portion with enamel margin and lower portion with dentin margin) prepared at buccal and lingual portion of premolars and molars. Each groups consist of 30 teeth. Devide into two groups, one without thermocycling and the other thermocycled. After then, infiltrate methylene blue into the gap between restoration and tooth. Within non-thermocycled groups, Single Bond 2.0 group shows lesser leakage at enamel margin than other two bonding agents (p <.05) but shows more leakage at dentin margin than other two bonding agents. (p <.05) Within thermocycled groups, Single Bond 2.0 group shows lesser leakage at both enamel and dentin margins. (p <.05)

In vitro cytotoxicity of self-etching primers (자가 산부식 프라이머의 세포독성에 관한 실험적 연구)

  • Rhee, Chang-Hoon;Kim, In-Ryeon;Kim, Gyoo-Cheon;Kim, Seong-Sik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.422-433
    • /
    • 2006
  • Objective: Several ions and components are released from self-etching primers in the oral cavity. This may cause injury to the periodontal tissues throughout orthodontic treatment. The purpose of this study was to assess the cytotoxicity of self-etching primers to HGF-1, HaCaT, and RHEK cells. Method: Transbond XT Primer (3M Unitek, Monrovia, CA, USA), and self-etching primers, Clearfil SE Bond (Kuraray, Osaka, Japan), Transbond Plus SEP (3M Unitek, Monrovia, CA, USA), and Adper Prompt L-Pop (3M Unitek, Monrovia, CA, USA), were evaluated by MTT assay, and cellular changes were also observed. Results: In all cells after 72 hours with all primers, severe morphological changes such as atrophy and necrosis were observed. In the MTT assay using HGF-1, Clearfil SE Bond, Transbond XT Primer, Transbond Plus SEP, and Adper Prompt L-Pop were lined up in order of ascending cytotoxicity When using HaCaT, Clearfil SE Bond, Adper Prompt L-Pop, Transbond Plus SEP, and Transbond XT Primer were lined up in order of ascending cytotoxicity. When using RHEK, Clearfil SE Bond, Transbond XT Primer, Adper Prompt L-Pop, and Transbond Plus SEP were lined up in order of ascending cytotoxicity. Conclusion: The result of this study shows that care is needed because self-etching primers show cytotoxic properties similar to conventional primers.

A STUDY ON THE FORMATION OF SHEAR BONDING STRENGTH AND HYBRID LAYER ACCORDING TO THE APPLICATION TIME AND FREQUENCY OF AN ALL-IN-ONE SYSTEM IN PRIMARY TEETH. (유치에서 All-In-One system의 적용 시간과 적용 횟수에 따른 전단 결합 강도 및 혼성층 형성에 관한 연구)

  • Hong, Sang-Jin;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.263-271
    • /
    • 2003
  • The purpose of the present study was to evaluate the patterns of hybrid layer according to the application time and the frequency and its effects on the shear bonding strength of All-In-One system in primary teeth. A single bonding agent(Scotchbond Multi-Purpose Plus, 3M) and an All-In-One system(Prompt L-pop, 3M ESPE) were applied on the dentin varying the application time and the frequency in primary teeth. Shear bond strength was measured and the patterns of hybrid layers were observed by SEM. The following results were obtained ; 1. The shear bonding strength of single bonding agent was significantly higher than that of All-In-One system(P<0.05). 2. The shear bonding strength of All-In-One system applied twice or 3 times were higher than that of applied once (P<0.05). And thickness of the hybrid layer was increased when applied twice or 3 times compared to once. 3. The shear bonding strength of All-In-One system when applied for 15 second and 30 second were higher than that of 7 second (P<0.05). And the hybrid layer thickness of 15 second and 30 second's application time were higher than that of 7 second. 4. Thickness of hybrid layer applied with single bonding agent was $2-4{\mu}m$ and that of All-In-One system was $1-2{\mu}m$.

  • PDF

MICROTENSILE BOND STRENGTH OF SINGLE STEP ADHESIVES TO DENTIN (상아질에 대한 단일 단계 접착제의 미세인장 결합강도)

  • Cho, Young-Gon;Kee, Young-Jae
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.312-318
    • /
    • 2005
  • This study compared the microtensile bond strength $({\mu}TBS)$ of three single step adhesives to dentin. Occlusal superficial dentin was exposed in fifteen human molars. They were assigned to three groups by used adhesives: Xeno group (Xeno III). Prompt group (Adper Prompt L-Pop). AQ group (AQ Bond). Each adhesive was applied to dentin surface. and composite of same manufacturer was constructed. The bonded specimens were sectioned into sticks with an interface area approximately $1mm^2$, and subjected to $\mu$ TBS testing with a crosshead speed of 1mm/minute. The results of this study were as follows; 1. The ${\mu}TBS$ to dentin was $48.78\pm9.83MPa$ for Xeno III. $30.22\pm4.52MPa$ for Adper Prompt L-Pop. and $26.31\pm7.07MPa$ for AQ Bond. 2. The mean ${\mu}TBS$ of Xeno group was significantly higher than that of Prompt group and AQ group (p<0.05). 3. There was no significant difference between the ${\mu}TBS$ of Prompt group and AQ group.

Evaluation of Microleakage with Retrograde Filling Materials in Blood Contamination (혈액 오염된 역충전 재료의 미세누출 평가)

  • Cho, Hye-Jin;Moon, Jhong-Hyun;Chon, Seong-Min;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2007
  • The purpose of this study was to evaluate the microleakage of root-end filling material filled in blood contaminated root-end cavity and self-etching adhesive placed over blood contaminated resected root apices without root-end preparation. Extracted, human maxillary incisors, canines and mandibular premolar were randomly divided into four groups of 15 teeth each. After canal preparation, resection of the apex and root-end preparation, MTA and IRM were filled in the root-end cavity (A and B group). After canal preparation and resection of the apex, Clearfil SE Bond and Prompt L-Pop were applied over the contaminated root-end surfaces (C and D group). The roots were then subjected to 15cm of water pressure to simulate periapical microleakage stress. Data were analyzed using one-way ANOVA. The results were as follows : 1. All groups showed a tendency of decreasing microleakage in process of time after 2weeks later except IRM group. 2. After 2 weeks and 1 month, MTA group showed less microleakage significantly than other groups(p<0.05). After 2 months, Prompt L-Pop group showed less microleakage significantly than other groups(p<0.05). 3. After 9 months, there were no significant differences among four groups(p>0.05). Thus it is considered that apical sealing using adhesives system without root-end preparation is good method in endodontic surgery.

A STUDY OF SHEAR BOND STRENGTH OF ER:YAG LASER-IRRADIATED PRIMARY DENTIN (Er:YAG 레이저를 조사한 유치 상아질의 전단결합강도에 관한 연구)

  • Lee, Jin-Hwa;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.569-578
    • /
    • 2007
  • This study was performed to compare the shear bond strength of self etching system and two bottle bonding system with or without laser preparation. Group I was prepared with high speed rotary instrument and $Prompt^{TM}$ L-$Pop^{TM}$, group II with Er:YAG laser and $Prompt^{TM}$ L-$Pop^{TM}$, group III with Er:YAG laser, 37% phosphoric acid and Single bond, group IV with Er:YAG laser and Single bond and group V with high speed, etching and Single bond. And also observation of the prepared and etched dentin surface were performed under scanning electro-microscope. The possibility of clinical application of laser preparation which might have an advantage to reduce pain for children with less unfavorable noise were evaluated. The results obtained are as follows; 1. Group V showed significantly higher bond strength than other groups. And group IV showed significantly lower bond strength than other groups. 2. There was no significant difference between group I and group III. 3. Group II showed significantly lower bond strength than group I, III, V, but showed significantly higher bond strength than group IV. 4. Under scanning electro-microscope, laser-preparated dentin surface showed high irregularity and no smear layer. The surface showed less irregularities and more exposed dentinal tubules with etching. Laser preparation has many advantages over conventional tooth preparation. But this method showed lower resin bonding strength. Laser preparated tooth surface differed from the conventionally preparated tooth surface. More researches are needed on suitable methods for laser preparated dentin surface.

  • PDF

MICRO-SHEAR BOND STRENGTH TO DENTIN UNDER SIMULATED PULPAL PRESSURE (치수압이 상아질 접착제의 미세전단 결합강도에 미치는 영향에 관한 In vitro 연구)

  • Song, Yun-Jung;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.339-345
    • /
    • 2004
  • The aim of this study was to measure and compare the micro shear bond strengths of the following dentin bonding systems to the dentin surfaces under simulated pulpal pressure: All Bond $2^{\circledR},{\;}Second^{\circledR},{\;}AdheSE^{\circledR}$, Adper Prompt $L-Pop^{\circledR}$. The occlusal surfaces of 180 extracted human molars were prepared so the dentin bonding surfaces could be exposed. The teeth were randomly assigned to 3 equal groups of 60 each and subdivided. The dentin surfaces were treated with the above mentioned bonding system and resin composite cylinders were built up under a simulated pulpal pressure when saline (Group II) or diluted bovine serum (Group III) was used as the pulpal fluid. As a control. the same procedures were performed in the dried dentin surfaces (Group I). After one day of storage in water. the micro shear bond strengths were measured using an EZ tester. Group II and III showed significantly lower shear bond strength than Group I statistically (p < 0.05). $SEbond^{\circledR}{\;}and{\;}AdheSE^{\circledR}$ showed no difference among the different dentin condition. In the Adper Prompt $L-Pop^{\circledR}$. a simulated pulpal pressure were applied to the specimens using diluted bovine serum. which showed a higher strength than the specimens in which saline was used (p < 0.05).