• Title/Summary/Keyword: Projection reconstruction

Search Result 265, Processing Time 0.032 seconds

Tomographic reconstruction of Asymmetric Spray by Direct Sampling Method (직접샘플링에 의한 비대칭 분무의 토모그래피 재구성)

  • Lee, C.H.;Won, J.C.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2002
  • Convolution Fourier transformation tomographically reconstructs the spatially resolved spray injection rate from direct measuring cells. Asymmetric sprays generated from a twin-hole air shroud injector are tested with 12 equiangular projections of measurements. For each projection angle, line of sight integrated injection rate was measured at 35 positions with equal spacing measuring cells of 3 mm in width, 100 mm in length, 55 mm in depth and 0.5 mm thickness of separating wall. Interpolated data between the projection angles effectively increase the number of projections, which significantly enhances the signal-to-noise level in the reconstructed data. This modified convolution Fourier transformation scheme predicts well the structure of asymmetric sprays. Comparative study has been made between sprays with and without air shrouding. Tomograhpic reconstruction of injection rate from direct measuring cells obtained can be used to estimate the accuracy of volume fraction of spray from the LDPA tomographic reconstruction.

  • PDF

3D Reconstruction using three vanishing points from a single image

  • Yoon, Yong-In;Im, Jang-Hwan;Kim, Dae-Hyun;Park, Jong-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1145-1148
    • /
    • 2002
  • This paper presents a new method which is calculated to use only three vanishing points in order to compute the dimensions of object and its pose from a single image of perspective projection taken by a camera and the problem of recovering 3D models from three vanishing points of box scene. Our approach is to compute only three vanishing points without this information such as the focal length, rotation matrix, and translation from images in the case of perspective projection. We assume that the object can be modeled as a linear function of a dimension vector ν. The input of reconstruction is a set of correspondences between features in the model and features in the image. To minimize each the dimensions of the parameterized models, this reconstruction of optimization can be solved by the standard nonlinear optimization techniques with a multi-start method which generates multiple starting points for the optimizer by sampling the parameter space uniformly.

  • PDF

A Comparative Study of Reconstruction Methods for LDV Spectral Analysis (LDV 스펙트럼 분석을 위한 재생방법의 비교 연구)

  • 이도환;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.166-174
    • /
    • 1994
  • A critical evaluation is made of the spectral bias which occurs in the use of a laser doppler velocimeter(LDV). Two processing algorithms are considered for spectral estimates: the sample and hold interpolation method(SH) and the nonuniform Shannon reconstruction technique(SR). Assessment is made of these for varying data densities $(0.05{\le}d.d.{\le}5)$ and turbulence levels(t.i.=30%, 100%). As an improved version of the spectral estimator, the utility of POCS (the projection onto convex sets) has been tested in the present study. This algorithm is found useful to be in the region when $d.d.{\gep}3.$

Tomographic Reconstruction of Two-Phase Flows

  • Ko, Han-Seo;Kim, Yong-Jae
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.571-580
    • /
    • 2003
  • Tomography has been investigated to observe bubble behaviors in two-phase flows. A bubbly flow and an annular flow have been reconstructed by tomography methods such as an algebraic reconstruction technique (ART) and a multiplicative algebraic reconstruction technique (MART) . Computer synthesized phantom fields have been used to calculate asymmetric density distributions for limited cases of 3, 5, and 7 projection angles. As a result of comparison of two tomography methods, the MART method has shown a significant improvement in the reconstruction accuracy for analysis of the two-phase flows.

Reducing Donor Site Morbidity When Reconstructing the Nipple Using a Composite Nipple Graft

  • Lee, Taik Jong;Noh, Hyung Joo;Kim, Eun Key;Eom, Jin Sup
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.384-389
    • /
    • 2012
  • Background Numerous procedures are available for nipple reconstruction without a single gold standard. This study presents a method for reducing donor-site morbidity in nipple reconstruction using a composite nipple graft after transverse rectus abdominis musculocutaneous flap breast reconstruction. Methods Thirty-five patients who underwent nipple reconstruction using a composite nipple graft technique between July of 2001 and December of 2009 were enrolled in this study. To reduce the donor site morbidity, the superior or superior-medial half dome harvesting technique was applied preserving the lateral cutaneous branch of the fourth intercostal nerves. The patients were asked to complete a previously validated survey to rate the color and projection of both nipples, along with the sensation and contractility of the donor nipple; and whether, in retrospect, they would undergo the procedure again. To compare projection, we performed a retrospective chart review of all the identifiable patients who underwent nipple reconstruction using the modified top hat flap technique by the same surgeon and during the same period. Results Thirty-five patients were identified who underwent nipple reconstruction using a composite nipple graft. Of those, 29 patients (82.9%) responded to the survey. Overall, we received favorable responses to the donor site morbidity. Projection at postoperative 6 months and 1 year was compared with the immediate postoperative results, as well as with the results of nipples reconstructed using the modified top hat flap. Conclusions The technique used to harvest donor tissue is important. Preserving innervation of the nipple while harvesting can reduce donor site morbidity.

Reconstruction of High-Resolution Facial Image Based on Recursive Error Back-Projection of Top-Down Machine Learning (하향식 기계학습의 반복적 오차 역투영에 기반한 고해상도 얼굴 영상의 복원)

  • Park, Jeong-Seon;Lee, Seong-Whan
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.3
    • /
    • pp.266-274
    • /
    • 2007
  • This paper proposes a new reconstruction method of high-resolution facial image from a low-resolution facial image based on top-down machine learning and recursive error back-projection. A face is represented by a linear combination of prototypes of shape and that of texture. With the shape and texture information of each pixel in a given low-resolution facial image, we can estimate optimal coefficients for a linear combination of prototypes of shape and those that of texture by solving least square minimizations. Then high-resolution facial image can be obtained by using the optimal coefficients for linear combination of the high-resolution prototypes. In addition, a recursive error back-projection procedure is applied to improve the reconstruction accuracy of high-resolution facial image. The encouraging results of the proposed method show that our method can be used to improve the performance of the face recognition by applying our method to reconstruct high-resolution facial images from low-resolution images captured at a distance.

Resolution analysis of Fourier Hologram using integral imaging

  • Chen, Ni;Park, Jae-Hyeung;Kim, Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.331-332
    • /
    • 2009
  • We present an analysis on the quality factors of the Fourier hologram generated from multiple orthographic view images of three-dimensional object. In the analysis, we analyze both the maximum size of the reconstructed object and its spatial resolution. For the maximum size of the reconstruction, we found that the main factor is the orthographic projection angle interval. Too large projection angle interval causes overlapping in the reconstruction space domain. For the spatial resolution, there are three factors, i.e. the capturing lens array pitch which determines the spatial sampling rate of the original three-dimensional objects, the maximum orthographic projection angle, and the spatial frequency bandwidth of the object. The dominant factor is determined by the relationship between those three factors.

  • PDF

PROJECTION ALGORITHMS WITH CORRECTION

  • Nicola, Aurelian;Popa, Constantin;Rude, Ulrich
    • Journal of applied mathematics & informatics
    • /
    • v.29 no.3_4
    • /
    • pp.697-712
    • /
    • 2011
  • We present in this paper two versions of a general correction procedure applied to a classical linear iterative method. This gives us the possibility, under certain assumptions, to obtain an extension of it to inconsistent linear least-squares problems. We prove that some well known extended projection type algorithms from image reconstruction in computerized tomography fit into one or the other of these general versions and are derived as particular cases of them. We also present some numerical experiments on two phantoms widely used in image reconstruction literature. The experiments show the importance of these extension procedures, reflected in the quality of reconstructed images.

Reconstruction of High-Resolution Facial Image Based on A Recursive Error Back-Projection

  • Park, Joeng-Seon;Lee, Seong-Whan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04b
    • /
    • pp.715-717
    • /
    • 2004
  • This paper proposes a new reconstruction method of high-resolution facial image from a low-resolution facial image based on a recursive error back-projection of top-down machine learning. A face is represented by a linear combination of prototypes of shape and texture. With the shape and texture information about the pixels in a given low-resolution facial image, we can estimate optimal coefficients for a linear combination of prototypes of shape and those of texture by solving least square minimization. Then high-resolution facial image can be obtained by using the optimal coefficients for linear combination of the high-resolution prototypes, In addition to, a recursive error back-projection is applied to improve the accuracy of synthesized high-resolution facial image. The encouraging results of the proposed method show that our method can be used to improve the performance of the face recognition by applying our method to reconstruct high-resolution facial images from low-resolution one captured at a distance.

  • PDF

A Study on the 3D Representation of 2D Projection Data using Epipolar Geometry (Epipolar 기하학을 이용한 2차원 투영 데이터의 3차원 표현에 관한 연구)

  • Yu, Seon-Guk;Wang, Ge;Kim, Nam-Hyeon;Kim,Yong-Uk;Kim, Hui-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.212-219
    • /
    • 2002
  • In this paper, the epipolar geometry, genera17y used as a pin-hole camera model, is newly adapted to our proposed method that enables the affine reconstruction of the 3D object from two projected views. The proposed method models the projective projection of inherent X-ray imaging system, obviates the need to attach artifirially constructed material on the body, and requires none of the prior-knowledge regarding to intrinsic and extrinsic parameters of two X-ray imaging systems. The optimum numerical solution is obtained by applying the least mean square estimator to corresponding points on two projected X-ray planes. The performance of this proposed method is Quantitatively analyzed using computer synthesized model of Cochlear implantation electrodes. In simulated experiments, the propnsed method is insensitive to the added random noise, the scaling factor change, the center point change, and rotational angular change between two projection planes, as well as enables the stable 3D reconstruction in least square sense even in worst testing cases.