• Title/Summary/Keyword: Projection Statistics

Search Result 154, Processing Time 0.022 seconds

Feasibility of Single-Shot Whole Thoracic Time-Resolved MR Angiography to Evaluate Patients with Multiple Pulmonary Arteriovenous Malformations

  • Jihoon Hong;Sang Yub Lee;Jae-Kwang Lim;Jongmin Lee;Jongmin Park;Jung Guen Cha;Hui Joong Lee;Donghyeon Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.794-802
    • /
    • 2022
  • Objective: To evaluate the feasibility of single-shot whole thoracic time-resolved MR angiography (TR-MRA) to identify the feeding arteries of pulmonary arteriovenous malformations (PAVMs) and reperfusion of the lesion after embolization in patients with multiple PAVMs. Materials and Methods: Nine patients (8 females and 1 male; age range, 23-65 years) with a total of 62 PAVMs who underwent percutaneous embolization for multiple PAVMs and were subsequently followed up using TR-MRA and CT obtained within 6 months from each other were retrospectively reviewed. All imaging analyses were performed by two independent readers blinded to clinical information. The visibility of the feeding arteries on maximum intensity projection (MIP) reconstruction and multiplanar reconstruction (MPR) TR-MRA images was evaluated by comparing them to CT as a reference. The accuracy of TR-MRA for diagnosing reperfusion of the PAVM after embolization was assessed in a subgroup with angiographic confirmation. The reliability between the readers in interpreting the TR-MRA results was analyzed using kappa (κ) statistics. Results: Feeding arteries were visible on the original MIP images of TR-MRA in 82.3% (51/62) and 85.5% (53/62) of readers 1 and 2, respectively. Using the MPR, the rates increased to 93.5% (58/62) and 95.2% (59/62), respectively (κ = 0.760 and 0.792, respectively). Factors for invisibility were the course of feeding arteries in the anteroposterior plane, proximity to large enhancing vessels, adjacency to the chest wall, pulsation of the heart, and small feeding arteries. Thirty-seven PAVMs in five patients had angiographic confirmation of reperfusion status after embolization (32 occlusions and 5 reperfusions). TR-MRA showed 100% (5/5) sensitivity and 100% (32/32, including three cases in which the feeding arteries were not visible on TR-MRA) specificity for both readers. Conclusion: Single-shot whole thoracic TR-MRA with MPR showed good visibility of the feeding arteries of PAVMs and high accuracy in diagnosing reperfusion after embolization. Single-shot whole thoracic TR-MRA may be a feasible method for the follow-up of patients with multiple PAVMs.

Analysis of effect of global uncertainty on domestic uncertainty using connectedness index (연계성 지수를 이용한 대외 경제 불확실성이 국내 경제 불확실성에 미치는 영향 분석)

  • Sanguk Kwon;Sun Ho Hwang
    • The Korean Journal of Applied Statistics
    • /
    • v.37 no.4
    • /
    • pp.509-523
    • /
    • 2024
  • This study estimates connectedness index among the US, China, Europe, Japan, and South Korea using monthly economic policy uncertainty (EPU) data from January 2000 to December 2023. The connectedness index allows us to analyze the effect of global economic uncertainty on domestic economic uncertainty. The EPU is used as a proxy for economic uncertainty. Inter-country connectedness index is computed from variance decomposition. The findings from forecast error variance decomposition show that three-fourths of total uncertainty comes from economic uncertainty in the own country and one-fourth of total uncertainty comes from economic uncertainty in the others. The analysis on net pairwise connectedness reveals that, even though the extent of the effect of economic uncertainty in one country from economic uncertainty in another country varies over time, economic uncertainty in South Korea, a small-open economy, is mainly affected by economic uncertainty in the others. The reverse situation rarely happens except in the specific occurrence such as the collapse of the credit bubble in 2003 and the subsequent years, the inter-Korean summit and North Korea-the US summit in 2018, and the period from the first outbreak of COVID-19 on the implementation of the government's severe regulation against COVID-19.

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Streamflow response to climate change during the wet and dry seasons in South Korea under a CMIP5 climate model (CMIP5 기반 건기 및 우기 시 국내 하천유량의 변화전망 및 분석)

  • Ghafouri-Azar, Mona;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.spc
    • /
    • pp.1091-1103
    • /
    • 2018
  • Having knowledge regarding to which region is prone to drought or flood is a crucial issue in water resources planning and management. This could be more challenging when the occurrence of these hazards affected by climate change. In this study the future streamflow during the wet season (July to September) and dry season (October to March) for the twenty first century of South Korea was investigated. This study used the statistics of precipitation, maximum and minimum temperature of one global climate model (i.e., INMCM4) with 2 RCPs (RCP4.5 and RCP8.5) scenarios as inputs for The Precipitation-Runoff Modelling System (PRMS) model. The PRMS model was tested for the historical periods (1966-2016) and then the parameters of model were used to project the future changes of 5 large River basins in Korea for three future periods (2025s, 2055s, and 2085s) compared to the reference period (1976-2005). Then, the different responses in climate and streamflow projection during these two seasons (wet and dry) was investigated. The results showed that under INMCM4 scenario, the occurrence of drought in dry season is projected to be stronger in 2025s than 2055s from decreasing -7.23% (-7.06%) in 2025s to -3.81% (-0.71%) in 2055s for RCP4.5 (RCP8.5). Regarding to the far future (2085s), for RCP 4.5 is projected to increase streamflow in the northern part, and decrease streamflow in the southern part (-3.24%), however under RCP8.5 almost all basins are vulnerable to drought, especially in the southern part (-16.51%). Also, during the wet season both increasing (Almost in northern and western part) and decreasing (almost in the southern part) in streamflow relative to the reference period are projected for all periods and RCPs under INMCM4 scenario.