• Title/Summary/Keyword: Progressive frequency

Search Result 132, Processing Time 0.036 seconds

Bovine leukocyte adhesion deficiency

  • Kehrli, Marcus E. Jr.;Park, Yong-ho;Yoo, Han-sang
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.2
    • /
    • pp.247-256
    • /
    • 1999
  • A disease of young Holstein calves characterized by recurrent pneumonia, ulcerative and granulomatous stomatitis, enteritis with bacterial overgrowth, periodontitis, delayed wound healing, persistent neutrophilia and death at an early age had been originally described in 1983 and again in 1987. Most of these calves had stunted growth and a persistent, progressive neutrophilia (often exceeding 100,000/ml). By investigation of pedigrees, all of the affected calves have now been traced to a common sire and confirmed by polymerase chain reaction (PCR) diagnostic DNA testing to be homozygous carriers of a defective allele for bovine CD18. Neutrophils from these calves have several functional deficits and, most importantly, fail to adhere in a ${\beta}_2$-integrin dependent manner. The ${\beta}_2$-integrins represent a family of glycoproteins which participate in various leukocyte adhesion reactions during host defense. The presence or absence of ${\beta}_2$-integrin molecules can be demonstrated on the surface of neutrophils, monocytes and lymphocytes from normal or affected calves using specific monoclonal antibodies and flow cytometry, or by colloidal gold immunolabeling and scanning electron microscopy in backscatter mode. Deficiency of the ${\beta}_2$-integrins on all leukocyte types in Holstein calves is analogous to leukocyte adhesion deficiency (LAD) seen in humans. Neutrophils in bovine (BLAD) and human LAD patients are unable to adhere to the endothelial lining of the cardiovascular system thus interrupting egression of neutrophils into infected tissues. Other leukocytes, while still deficient in expression of the ${\beta}_2$-integrins, are still able to efficiently egress from the blood stream due to interactions of other adhesion molecules that are not as highly expressed on neutrophils. Both BLAD cattle and LAD children (who do not receive bone marrow transplants) often die at an early age as a result of the failure of neutrophils to extravasate into infected tissues. In 1991, Shuster, et $al^{27}$, identified two point mutations within the alleles encoding bovine CD18 in a Holstein calf afflicted with leukocyte adhesion deficiency. One mutation causes an aspartic acid to glycine substitution at amino acid 128 (D128G) in an extracellular region of this adhesion glycoprotein that is highly conserved (> 95% identity) between humans, cattle and mice. The other mutation is silent. Numerous calves with clinical symptoms of leukocyte adhesion deficiency have since been tested and all have been found homozygous for the D128G allele. In addition, calves homozygous far the D128G allele have been identified during widespread DNA testing in the United States. All cattle with the mutant allele are related to one bull, who through artificial insemination (A.I.), sired many calves in the 1950's and 1960's. The carrier frequency of the D128G CD18 allele among U.S. Holstein cattle had reached approximately 15% among active A.I. bulls and 8% among cows. By 1993, the organization of the dairy industry and the diagnostic test developed to genotype cattle, enabled virtually complete eradication of bovine leukocyte adhesion deficiency among current and future A.I. bulls.

  • PDF

The Etiology of the Diffuse Infiltrative Disease of the Lung in Korea (한국에서의 미만성 침윤성 폐질환의 원인별 분포)

  • Kim, J.H.;Choi, S.J.;Kim, D.S.;You, J.H.;Kang, H.M.;You, S.H.;Jo, D.I.;Kim, J.W.;Han, S.K.;Kim, K.Y.;Kim, Y.S.;Park, C.S.;Kim, W.S.;Kim, W.D.;Jang, J.;Lee, W.Y.;Choi, B.H.;Hue, S.H.;Shin, D.H.;Lee, J.H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.38 no.1
    • /
    • pp.1-7
    • /
    • 1991
  • To study the frequency of the underlying disease of the diffuse pulmonary infiltrates in korea, we ansalyzed retrospectively 982 patients who were seen at nine university hospitals and one general hospital in Seoul area. The results are folloing: 1) Among the total 982 patients, 490 patients were male and 492 patients were female. The mean age was 44.3 years. 2) The most common etiology was milliary tuberculosis (38%), which was followed by, idopathic pulmonary fibrosis (27%), pulmonary fibrosis associated with collagen-vascular disease (15%), and diffuse pulmonary infiltrates by malignancy (10%). 3) Amon the connective tissue disease which was accompanied by the interstitial lung disease, rheumatoid arthritis was the most common disease (43%), systemic lupus erythematosus was the 2nd (28%), and progressive systemic sclerosis was the 3re (16%). 4) Among 101 cases of malignant disease, lung was the most frequent primary site (31%), which was followed by stomach (28%), thyroid (16%), and breast (6%). 5) For the diagnosis of the underlying disease of pulmonary infiltrates, the transbronchial lung biopsy was performed in 21% of the patients and open lung biopsy was done in 7%.

  • PDF

A Scene Boundary Detection Scheme using Audio Information in MPEG System Stream (MPEG 시스템 스트림상에서 오디오 정보를 이용한 장면 경계 검출 방법)

  • Kim, Jae-Hong;Nang, Jong-Ho;Park, Soo-Yong
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.8
    • /
    • pp.864-876
    • /
    • 2000
  • This paper proposes a new scene boundary detection scheme for the MPEG System stream using MPEG Audio information and proves its usefulness by extensive experiments. A scene boundary has a characteristic that the audio as well as video information are changed rapidly. This paper first classifies this scene boundary into three cases ; Radical, Gradual, Micro Changes, with respect to the audio changes. The Radical change has a large-scale changing of decibel value and pitch value at a scene boundary, the Gradual change shows the long-time transition of decibel and pitch values from max to min or vice versa, and the Micro change displays a some change of pitch or frequency distribution without decibel changes. Upon this analysis, a new scene change detection algorithm detecting these three cases is proposed in which a progressive window with a time line is used to trace the changes in the audio information. Some experiments with various movies show that proposed algorithm could produce a high detection ratio for Radical change that is the most popular scene change in the movies, while producing a moderate detection ratio for Gradual and Micro changes. The proposed scene boundary detection scheme could be used to build a database for visual information like MPEG System stream.

  • PDF

Parasympathetic Modulation Plays a Key Role in Initiation of Paroxysmal Atrial Fibrillation

  • Lee, Won-Jae;Shin, Dong-Gu;Hong, Geu-Ru;Park, Jong-Sun;Kim, Young-Jo
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.216-231
    • /
    • 2007
  • Background : An acceleration or deceleration of the heart rate (HR), which reflects autonomic effects, is observed before the onset of paroxysmal atrial fibrillation (PAF). The purpose of this study was to assess the discrepancy in the autonomic interactions before the onset of PAF for different patterns of change in the HR. Materials and Methods : From 105 Holter tapes with the PAF recorded, 55 episodes (42 patients, 34 men, $58{\pm}12$ years) of PAF (>5 min), preceded by a sinus rhythm for more than 1 hour, were selected and submitted to time-domain and frequency-domain HR variability analyses. Fifty-five episodes were divided into 2 groups: group A PAF (n=30) with acceleration of the HR during the last 2 minutes before the PAF and group B (n=25) with deceleration of the HR. Results : A significant linear decrease in the mean R-R interval was observed in group A ($924{\pm}30$ to $835{\pm}28ms$, $P$=0.001) and an increase from $831{\pm}32$ to $866{\pm}31ms$ in group B PAF episodes ($P$=0.046). In the frequency-domain analyses, the LF/HF ratio exhibited a progressive linear increase before the PAF in group A ($P$=0.005). The HF normalized units (HFnu) and natural logarithm-transformed HF ($In$HF) values decreased from $30.8{\pm}4.0$ to $16.1{\pm}1.8$ ($P$=0.003) and $4.49{\pm}0.25$ to $4.07{\pm}0.22$ ($P$=0.001), respectively. Contrary to the results in group A, a significant increase in the HF components (HFnu and $In$HF) (from $22.6{\pm}3.2$ to $30.2{\pm}4.0$, $P$=0.005, and $4.27{\pm}0.27$ to 4.75 0.33, $P$=0.001, respectively) and a resultant decrease in the LF/HF ratio were observed in group B PAF episodes. No significant changes were observed in the LF components in either PAF group. Conclusion : Autonomic stimuli leading to an acceleration or deceleration of the HR before the onset of AF are due to parasympathetic modulation. Parasympathetic modulation plays a key role in the initiation of PAF.

  • PDF

A Comparative Analysis of the Clinical and Pathological features of IgA Nephropathy and Thin Glomerular Basement Membrane Disease (IgA 신병증과 비박형 기저막 신증의 임상 및 병리학적 비교 분석 - 사구체 기저막의 비박화를 중심으로 -)

  • Chi, Geun-Ha;Ha, Chang-Woo;Kim, Young-Ju;Yoon, Hye-Kyung;Chung, Woo-Yeong
    • Childhood Kidney Diseases
    • /
    • v.5 no.2
    • /
    • pp.147-155
    • /
    • 2001
  • Purpose : IgA nephropathy(IgAN) and thin glomerular basement membrane disease(TGBMD) are common glomerular diseases that cause hematuria in childhood. IgAN has characteristics of IgA deposit as the sole or predominantly localized to the mesangium Recently, it has been reported that thinning of glomerular basement membrane(GBM) is commonly accompanied with precipitation of electron dense deposits in IgAN. We performed this study to examine the frequency of thinning of GBM among children with IgAN and to analysis tile correlation between urinary abnormalities and GBM thickness and furthermore to conduct comparative analysis of the clinical and pathological features of IgAN and TGBMD. Methods : This study summarizes data collected from Department of Pediatrics, Busan Paik Hospital, Inje Medical College. Data include 51 cases who were diagnosed as IgAN from 1995 to 2000, and 26 cases who were diagnosed as TGBMD from 1990 to 2000 by percutaneous renal biopsy. Results : Males accounted for 29/51($56.9\%$) patients with IgAN and 8/26($30.8\%$) of those with TGBMD. The clinical and laboratory features between IgAN and TGBMD were significantly different regarding the incidence of proteinuria(IgAN vs TGBMD: $43.1\%\;vs\;3.8\%$, p=0.001), the incidence of co-appearance of proteinuria with hematuria ($41.2\%\;vs\;3.8\%$, p=0.001), total amount of protein in 24 hours collected urine ($808{\pm}\;mg\;vs\;251{\pm}200.7\;mg$, p=0.001) and the incidence of proteinuria more than 1 gm in 24 hours collected urine ($23.5\%\;vs\;3.8\%$, p=0.01). On the contrary, there were no significant differences in the levels of serum albumin, creatinine, BUN, and Ccr between two groups. The mean thickness of GBM in patients with IgAN was $293.0{\pm}79.2\;nm$(139.7-461.9 nm) and $180.9{\pm}35.8\;nm$(110.5-229.5 nm) in patients with TGBMD. The mean GBM thickness revealed significantly thinner in TGBMD compared than those with IgAN (P=0.0001). The frequency of thickness being less than 250 nm was $37.4{\pm}34.4\%$ in IgAN and $93.0{\pm}7.0\%$ in TGBMD (P=0.0001). But there were no correlations between urinary abnormalities and GBM thickness in patients with IgAN. Conclusion : The thinning of GBM would be one of the common pathological findings in IgAN Moreover, there is no significant correlations between urinary abnormalities and GBM thickness in patients with IgAN, However, patients with IgAN tend to have significantly higher possibilities of proteinuria, co-appearance of proteinuria with hematuria and higher total amount of protein in 24 hours collected urine compared those with TGBMD. These differences might be play all important role as progressive prognostic indicators in patients with IgAN. (J Korean Soc Pediatr Nephrol 2001;5 : 136-46)

  • PDF

A Study of Community Awareness in Local Residents after the Restoration of Seongnaecheon (성내천 복원 후 지역주민의 커뮤니티 의식에 대한 연구)

  • Kim, Nam-Su;Lee, In-Hwan;Kim, Yong-Geun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.4
    • /
    • pp.74-82
    • /
    • 2011
  • During the industrialization and urbanization of the country, urban rivers have been covered over and developed without forethought and thus became estranged from spaces utilized by area residents in everyday life. Recently, an influx of people and uses have increased largely because accessibility improved through restoration projects which have transformed these river areas into pleasant environments. It thus appears that these projects have an impact on community consciousness for area residents who live near the restored rivers to some extent. The purpose of this study was to determine via questionnaire the effects and influences of urban river restoration on area residents targeting visitors to Seongnaecheon(stream), Songpa-gu, Seoul, which has been restored recently. Factors in the questionnaire analysis included such items as the use status of Seongnaecheon, community consciousness(feeling of belonging, solidarity, feeling settled), and a before and after comparison of the restoration(change of consciousness, regional effects), etc. According to the results of analysis, visitors who have utilized the stream more than 1~2 times per week after the restoration project accounted for the greatest portion. The main purposes of these visits were to 'rest' and 'exercise' while the ratio of using it as a 'meeting space with neighbors and strangers' was low. Community consciousness of area residents using Seongnaecheon was generally high. As a result of an analysis of consciousness differences between groups after dividing visitors into 3 groups according to the frequency of visits, there were significant differences in the consciousness level between groups with high community consciousness levels in visitors who visited frequently. In consideration of these results, the provision of programs along with proper facilities that can be used is deemed important for area residents so as to inspire community consciousness of the area by means of activating both community activities and the progressive use of the restored river.

A Study on the Consumer's Service Quality Perception Based on the Types of Life-style (소비자의 라이프스타일에 따른 서비스품질 지각 차이에 관한 연구)

  • Park, Yoon-Seo;Lee, Seung-In;Choi, In
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.2
    • /
    • pp.53-67
    • /
    • 2009
  • For the last decades, service quality has been studied as one of the most important tools for a service company to compete with the other companies. Based on these past researches, it has been agreed that the service quality is a basic and powerful tool to create the competitive advantage. Due to similar reason, many service marketing practitioners have been also focused on the service quality to retain the existing consumers and collect the new consumers. However, service quality is subjectively perceived by individual consumers. Consumer evaluation of service quality can be different from each other. Especially consumers with one life-style may evaluate the service quality differently from the consumers with the other life-styles. Therefore we need to know whether there are differences in service quality perception on the categories of life-style. Life-style refers to a distinctive mode of living in its aggregate and broadest sense. It embodies the patterns that were developed and emerged from the dynamics of living in a society. Since the concept of life-style and its relationship to marketing was introduced in 1963 by William Lazer, methods of measuring the life-style and their application have been developed. Life-style has been usually used to segment the marketplace because it offers marketers a unique and important view of the market. When Life-style is combined with clustering methods, life-style segmentation can generate identifiable whole persons rather than isolated fragment. Life-style segmentation begins with people instead of products and classifies them into different life-style types, each characterized by a unique style of living based on a wide range of activities, interests, and opinions(Plummer, 1974). In this study we applies the life-style segmentation based on the AIO(Activities, Interests, and Opinions) to the consumers of the large discount stores. In Korea, the large discount store market has entered into maturity stage so that the market differentiation strategy is becoming a more critical issue to the marketing practitioners. One of the most important tools to differentiate from the competitors in large discount store market is continuously to provide service of better quality than competitors. This study tries to find answers about the following questions: 1) How can we categorize the consumer life-styles in the large discount store? 2) What are the characteristics of the categorized groups? 3) Are there any differences in service quality perception among the consumers with different life-styles 4) Are there any differences in consumer behavior among them in the large discount store? For the purpose, we collected survey data from consumers and analyzed the data with the SPSS package where we had $X^2$-test, factor analysis, ANOVA, MANOVA, and cluster analysis. The survey was made during one month in the April of 2008. Among the collected 306 copies of questionnaires, 281 copies were chosen as the effective samples for empirical analysis except 25 copies with wrong responses. To identify the life-style patterns, we used the measures employed by Kim and Kwon(1999), where 44 items on a seven-point scale were used to measure factors of the life-style patterns. The Principal Component Method was used for factor extraction, and the VARIMAX orthogonal factor rotation was employed. The 7 items showing low factor loading were eliminated. The results of the factor analysis suggested that nine factors of the life-style patterns were identified as follows: 1) the equality-of-sexes and pursuit-of-independence tendency 2) self-management tendency 3) sociable tendency 4) self-display tendency 5) degree of a dilettante life 6) pursuit-of-information tendency 7) bargain hunter tendency 8) TV preference tendency 9) pursuit-of-leisure tendency. Next, after the K-means cluster analysis was performed with nine factors of the life-style patterns, the life-styles of the respondents were classified into four groups which are named as the 'progressive practicality-oriented group', 'positive success-oriented group', 'sociable ostentation-oriented group', 'stable conservation-oriented group'. The analysis results for usage behavior between the market segments showed statistically significant differences in the frequency of usage, duration time in the store, consumer satisfaction, and loyalty. Also, we tried to investigate whether the large discount store consumers differently perceive the quality of service based upon the types of life-style. To measure the service quality of large discount store, we adapted several measurement models measuring the service quality such as SERVPERF, BCP, R-SERVPERF, R-BCP. MANOVA and One-Way ANOVA were performed to confirm the difference in service quality perception based on the market segments. The results have also shown significant differences between life-style types in service quality perception. These findings show that the large discount store marketers should consider consumer life-style as one of the most important market segments for marketing and understand the difference in service quality perception between life-style types. Our findings give important implications to marketers of large discount stores as well as life-style researchers. First, this study showed there were significant differences in consumer's service quality perception and usage behavior between the types of life-style. It provides evidence that the life-style approach can be a important basis in segmenting the large discount store market and will make consumers perceive the service quality high. Second, most previous researches on service quality have been in aggregate level. However, our results imply that the future research on service quality have to focus on segment level.

  • PDF

Evaluation for Rock Cleavage Using Distribution of Microcrack Lengths (미세균열의 길이 분포를 이용한 결의 평가)

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.165-180
    • /
    • 2015
  • Jurassic granite from Geochang was analysed with respect to the characteristics of the rock cleavage. The phases of distribution of microcracks were well evidenced from the enlarged photomicrographs(${\times}6.7$) of the thin section. In this study, the length - cumulative frequency diagrams were used for expressing the distribution characteristics of microcrack. The diagrams for the six directions were arranged in the magnitude of density(${\rho}$). These diagrams show an order of H2 < H1 < G2 < G1 < R2 < R1 from the related chart. Among six diagrams, the diagram for hardway 2(H2) occupies the lowermost region on the left. On the contrary, the diagram for rift 1(R1) occupies the uppermost region on the right. Curve patterns of the two diagrams change from uniform to exponential distribution type in accordance with the increased density. The overall distribution characteristics of the diagrams were well evidenced from the magnitude of the exponent(${\lambda}$) and length of line oa related to the exponential straight line. The magnitude of exponent governing the values of slope(${\theta}$) is inversely proportional to the values of microcrack parameters such as number(N), length(L) and density. On the contrary, length of line oa is directly proportional to the values of the above three parameters. Above microcrack parameters related to the order of arrangement of diagrams show an order of hardway(H1 + H2) < grain(G1 + G2) < rift(R1 + R2). The distribution characteristics of progressive variation are found among the six diagrams. The order of arrangement of the diagrams indicates a relative magnitude of the rock cleavage. Meanwhile, the parameters such as slope, exponent, density and length of line oa were arranged in an order of H2 < H1 < G2 < G1 < R2 < R1. The variation curves of a smooth quadratic function are shown from the related chart. From the correlation chart between density and the above parameters, a common regularity following power-law correlation function was derived. Finally, the analysis for the rock cleavage was conducted through the combination between the diagram and microcrack parameter. This type of combination contribute to the progressivity in evaluation for the rock cleavage.

Factors affecting the Organizational Commitment of Industrial Accident Hospital Employees by Job Category (병원 구성원들의 직종별 조직몰입의 영향요인에 관한 연구)

  • Bang, Yong-Joo;Ha, Ho-Wook;Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.7 no.4
    • /
    • pp.24-56
    • /
    • 2002
  • The purpose of this study was to analyze the characteristics of socio-demographic, organizational culture, organizational conflict and organizational commitment, and to examine the interrelation of influential factors in the organizational commitment. The data for this study were collected through a self-administrated survey with a structured questionnaire to 1,027 subjects from several medical doctor staff members, nursing staff members, administration staff members, pharmacist, and technical expert of eleven hospitals. The data were collected by self-reporting questionnaire from July 29 to September 7, 2002. In this analysis frequency test, t-test, ANOVA, multiple regression were used. The main results of this research is as following; 1. According to socio-demographic characteristics the respondents' level of the organizational commitment was higher in a administration staff members than others, for males than females, and for employees aged more than forty, as working for longer time, and as higher level of the working position. 2. According to the organizational culture characteristics the progressive culture, affiliative culture, and task-focused culture among many types of organizational culture were moderately and positively correlated with the level of the organizational commitment while the hierarchical culture was negatively correlated. 3. According to the organizational conflict characteristics as the respondents who got less conflict experience in the organization, their level of the organizational commitment was higher. And, technical conflict experiences were expressed greater than hierarchical conflict experiences. 4. According to the job satisfaction characteristics as his or her satisfaction that is about the promotion, working itself, salary, and fellowship in the organizational was higher, the level of the organizational commitment was higher. The most important factor of the satisfactions was the fellowship among the respondents while the level of job satisfaction for the promotion and salary was average. 5. Overall, according to the result of Multiple Regression as older age and longer working hours, the level of the organizational commitment was higher and as a higher level of the satisfaction for the promotion, working itself, salary, and fellowship in the organization, it caused more effective factors for the organizational commitment. 6. According to the result of Multiple Regression for the doctor staff members in special hospitals rather than general hospitals the hierarchical culture and task focused culture was positively correlated with the satisfaction of working itself while hierarchical conflict factors in the organizational conflict characteristics was negatively correlated with the organizational commitment. For the nursing staff members the affiliative culture and the job satisfaction for the promotion, working itself, salary, and fellowship were positively correlated with the organizational commitment. For the administration staff members as the job satisfaction for the fellowship was positively correlated with the organizational commitment. For medical and pharmacy staff members as more working experience, correlation with the organizational commitment was positive. Besides, as he or she has a high perception of the affiliative culture, it caused statistically more effective factors for the organizational commitment. For the skill and technicians, male worker expressed greater organizational commitment in the organization than female worker. And also older age along with higher education also showed higher organizational commitment. Moreover, the job satisfaction for the fellowship was positively correlated with the organizational commitment. This study identified the major effective factors of the organizational commitment and analyzed the differences among the job category. In that respect, it is significant for the study to be able to provide a reference for managing hospital of industrial accident and organizational development. However, this study has a problem, which is not to identify a valuable model for examining the relationship between organizational factors such as organizational culture, conflict, satisfaction, and commitment. Therefore, further study is needed and strengthened in the field of organizational commitment for hospital for industrial accident.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF