The authors discuss a prototype stylus profilometer designed to measure large optics. It consists of a low contact force type probe system, laser reference system, interferometric distance measurement system, and horizontal driving system. The probe contacts the surface ; the height and the horizontal distances of the measurement points are measured by the interferometer. The freely propagated laser beam provides the reference line during the measurement. The developed stylus profilometry shows only $\pm$60 nm of P-V error for the 157 mm diameter spherical mirror.
In this study, TiCrN films were deposited on STS 316 Land Si (100) wafer by inductively coupled plasma (ICP) assisted D.C. magnetron sputtering. The effect R.F. power for ICP discharge on the mechanical properties of TiCrN films was investigated. XRD, XPS and FE-SEM were used for the structure analysis. Also the Micro-Knoop hardness tester and profilometer were used for measuring hardness of coatings and film stress respectively. As increasing the R.F. power for ICP discharge, thickness of coating was decreased from 1633 nm to 1288 nm but hardness was increased about $Hk_{5g}$ 4200 at 400 W. All of the XRD patterns showed (111), (200) and (220) peaks of TiCrN films. Surface morphology was studied using the profilometer. FE-SEM was used to know morphology and cross-section of the films. Structure of the films was changed dense as increased ICP power.
Kim, Sanghyuk;Pak, Soojong;Jeong, Byeongjoon;Shin, Sangkyo;Kim, Geon Hee;Lee, Gil Jae;Chang, Seunghyuk;Yoo, Song Min;Lee, Kwang Jo;Lee, Hyuckee
The Bulletin of The Korean Astronomical Society
/
v.39
no.2
/
pp.103-103
/
2014
Manufacturing of lens and mirror using Diamond Turning Machine (DTM) offers distinct advantages including short fabrication time and low cost as compared to grinding or polishing process. However, the DTM process can leave mid-frequency error in the optical surface which generates an undesirable diffraction effect and stray light. The mid-frequency error is expected to be eliminated by mechanical polishing after the DTM process, but polishing of soft surface of ductile aluminum is extremely difficult because the polishing process inevitably degrades the surface form accuracy. In order to increase its surface hardness, we performed electroless nickel plating on the surface of diamond-turned aluminum (Al-6061T6) off-axis mirrors, which was followed by the 6-hour-long baking process at $200^{\circ}C$ for improving its hardness. Then we polished the nickel plated off-axis mirrors to remove the mid-frequency error and measured polished mirror surfaces using the optical surface profilometer (NT 2000, Wyko Inc.). Finally, we ascertained that the mid-frequency error on the mirror surface was successfully removed. During the whole processes of nickel plating and polishing, we monitored the form accuracy using the ultra-high accurate 3-D profilometer (UA3P, Panasonic Corp.) to maintain it within the allowable tolerance range (< tens of nm). The polished off-axis mirror was optically tested using a visible laser source and a pinhole, and the airy pattern obtained from the polished mirror was compared with the unpolished case to check the influence of mid-frequency error on optical images.
Kim, Namyoon;Lee, Seung Woo;I, Yongjun;Pahk, Heui-Jae
Current Optics and Photonics
/
v.1
no.6
/
pp.604-612
/
2017
An effective and precise method using a scanning white-light interferometer (SWLI) for three-dimensional surface measurements, in particular for roughness measurements, has been proposed. The measurement of a microscopically sloped area using an interferometer has limitations, due to the numerical aperture of the lens. In particular, for roughness measurements, it is challenging to obtain accurate height data for a sloped area using the interferometer, due to diffraction of the light. Owing to these optical limitations of the interferometer for roughness measurements, the Ra measurements performed using an interferometer contain errors. To overcome the limitations, we propose a method consisting of the following two steps. First, we evaluate the height data and set the invalid height area to be blank, using the characteristics of the modulus peak, which has a low peak value for signals that have low reliability in the interferogram. Next, we interpolate the blank area using the adjacent reliable area. Rubert roughness standards are used to verify the proposed method. The results obtained by the proposed method are compared to those obtained with a stylus profilometer. For the considered sinusoidal samples, Ra ranges from $0.053{\mu}m$ to $6.303{\mu}m$, and we show that the interpolation method is effective. In addition, the method can be applied to a random surface where Ra ranges from $0.011{\mu}m$ to $0.164{\mu}m$. We show that the roughness results obtained using the proposed method agree well with profilometer results. The $R^2$ values for both sinusoidal and random samples are greater than 0.995.
Purpose: The aim of the present study was to evaluate the biological response of alkali- and heat-treated titanium-8tantalum-3niobium surfaces by cell proliferation and alkaline phosphatase (ALP) activity analysis. Methods: Commercial pure titanium (group cp-Ti) and alkali- and heat-treated titanium-8tantalum-3niobium (group AHT) disks were prepared. The surface properties were evaluated using scanning electron microscopy, energy dispersed spectroscopy and X-ray photoelectron spectroscopy (XPS). The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were also analyzed. The biological response of fetal rat calvarial cells on group AHT was assessed by cell proliferation and ALP activity. Results: Group AHT showed a flake-like morphology microprofile and dense structure. XPS analysis of group AHT showed an increased amount of oxygen in the basic hydroxyl residue of titanium hydroxide groups compared with group cp-Ti. The surface roughness (Ra) measured by a profilometer showed no significant difference (P>0.05). Group AHT showed a lower contact angle and higher surface energy than group cp-Ti. Cell proliferation on group AHT surfaces was significantly higher than on group cp-Ti surfaces (P<0.05). In comparison to group cp-Ti, group AHT enhanced ALP activity (P<0.05). Conclusions: These results suggest that group AHT stimulates osteoblast differentiation.
Kim, Young-Sung;Kim, Soo-Hwan;Kim, Won-Kyung;Lee, Young-Kyoo
Journal of Periodontal and Implant Science
/
v.39
no.4
/
pp.385-390
/
2009
Purpose: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. Methods: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. Results: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. Conclusions: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.
Kim, Kyul;Lee, Bo-Ah;Piao, Xing-Hui;Chung, Hyun-Ju;Kim, Young-Joon
Journal of Periodontal and Implant Science
/
v.43
no.4
/
pp.198-205
/
2013
Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse $MC_3T_3-E_1$ cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide ($TiO_2$) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized $TiO_2$ surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.
Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
/
2002.11a
/
pp.36-46
/
2002
The accurate characterization of paper structure may provide critical information for ideal selection of raw materials and papermaking processes as well as for predicting the behavior and the quality of final paper products. In this study, local paper structure and the relationship among the structural parameters, thickness, grammage, apparent density and surface roughness of various handsheet and commercial paper samples were evaluated by using recently developed methods. A new concept of surface roughness was also introduced. The results demonstrate that there is significant overestimation in the measured thickness when using the conventional caliper method that originates from the surface roughness and poor paper formation. A novel non-contact thickness tester, referred to as the twin laser profilometer(TLP), provided results that were not subject to these artifacts and thus provided the local intrinsic thickness and consequently the local intrinsic apparent density.
In this review article, in vivo and in vitro wear test methods which measure the wear of tooth and restorative material were discribed. In vivo test, the criteria of each test were reviewed. The merits and limitations were also commented. In vitro tests, three dimensional scanning methods which scan the occlusal tooth surface three dimensionally were described. Profilometer method, Pin on disk method, laser scanner method were reviewed and the limitations of each test were commented. Additionally, the structer of the three dimensional scanner which has been developed in Zurich university and has been reputated as the most accurate one was described. This study was partly supported by 1997 post-doctoral foreign study program.
The purpose of this study was to roughness on the polished surface of visible light composite resins and was to observe the polished surfaces under Scanning Electrom Microscope(ISI DS 130 AKASHI Co. JAPAN). The surface roughness tester(Surfcom 700A Seimtsu profilometer Tokyo, Japan) was used to measure roughness of polished surfaces. In this study, 5 brands of visible of composite resins were examined, Pyrofile light bond Anterior Lite fil anterior Photo clearfil anterior & posterior Palfique light Anterior and posterior Silux Anterior. White point, Silicure point, Super snap Sof-Lex medium disk as cutting instrument, and celluloid matrix were used. The results obtained were as follows. 1. The Celluloid matrix produced the smoothest surfaces. 2. The surfaces made by Soflex medium disk was smoother than the surfaces made by any other polishing instruments. 3. The values of surface roughness made by White point, Silicon point and Super snap were similer. 4. Palfique light (AP) visible light composite resin showed the smoothest surface after polishing with Silicone point, Super snap disk and Soflex mediuem disk in all tested materials.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.