• Title/Summary/Keyword: Production Test site

Search Result 129, Processing Time 0.022 seconds

The Strength Properties of Concrete Used Stone Powder Sludge as Siliceous Material (실리카질 재료로서 석분 슬러지를 사용한 콘크리트의 강도 특성)

  • Jeong Ji Yong;Choi Sun Mi;Kawg Eun Gu;Choi Se Jin;Lee Seong Yeon;Kim Jin Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.85-88
    • /
    • 2005
  • The stone powder sludge occurred at aggregate production process is classified the specified waste, so it is disposed by appropriate method. But the problems of the shortage of the disposal-site, the environment pollution, and the increase of disposal cost can be occurred in handling process, therefore the stone powder sludge is required the development of recycling technique. The stone powder sludge includes SiO2 of about $63\%$. This characteristic is important at the production of hardened specimens under condition of hydro-thermal reaction. In this study, we investigated the strength properties of concrete used stone powder sludge as siliceous material. The test results under condition of hydro-thermal reaction shows the two main facts. The first, the stone powder sludge is affected to fluidity because the surface of the stone powder sludge has characteristics of flakily and angularity. The second, weight content of the stone powder sludge, is not effective factor to the properties of strength.

  • PDF

Evaluation of the Performance on WindPRO Prediction in the Northeast Region of Jeju Island (제주 북동부지역을 대상으로 한 WindPRO의 예측성능 평가)

  • Oh, Hyun-Seok;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.22-30
    • /
    • 2009
  • In order to clarify predictive accuracy for the wind resource predicted by running WindPRO(Ver. 2.5) which is software for wind farm design developed by EMD from Denmark, an investigation was carried out at the northeast region of Jeju island. The Hangwon, Susan and Hoichun sites of Jeju island were selected for this study. The measurement period of wind at the sites was for one year. As a result, when the sites had different energy roses, though the two Wind Statistics made by STATGEN module were used for the prediction, it was difficult to exactly predict the energy rose at a given site. On the other hand, when the two Wind Statistics were used to predict the average wind speed, the wind power density and the annual energy production, the relative error was under ${\pm}20%$ which improved more than that when using only one Wind Statistics.

Power Curve Measurements on the 6kW Wind Turbine (6kW 풍력발전기의 출력곡선 측정)

  • Yoo, Neung-Soo;Nam, Yoon-Su;Lee, Jung-Wan;Cho, Joo-Suk
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.149-157
    • /
    • 2005
  • The power performance monitoring system for a small class of wind turbine is established. The wind turbine power performance characteristics are determined by measured power curve and the estimated annual energy production (AEP). The measured power curve is determined by collecting simultaneous measurements of wind speed and power output at the test site under varying wind conditions. In order to determine the power performance characteristics of the wind turbine accurately, the data are of sufficient quantity and quality shall be corrected according to defined criteria. In this study, the 6kW wind turbine made by Germany Inventus GmbH is examined.

  • PDF

Comparative Analysis of Commercial Softwares for Wind Climate Data Analysis (풍력자원 계측자료 분석용 상용 소프트웨어 비교분석)

  • Kim, Hyun-Goo
    • New & Renewable Energy
    • /
    • v.6 no.2
    • /
    • pp.5-11
    • /
    • 2010
  • This paper reviews three commercial softwares for wind climate data analysis in wind resource assessment; WAsP/Observed Wind Climate, WindRose and Windographer. Windographer is evaluated as the best software because of its variety of input data format, analysis functions, easiness of user interface, etc. For a quantitative understanding of uncertainty depending on software selection, a benchmark is carried out with the met-mast observation dataset at the Gimnyeong Wind Turbine Performance Test Site. It is found that Weibull parameter calculation and air density correction have a dependency on the software so that such uncertainty should be considered when an analysis software is selected. It is confirmed that annual energy production calculated by WAsP using a statistical table of frequency of occurrence may have some error compared to a time-series calculation method used by the other softwares.

A Study on Characteristics of Normal Strength Concrete adapted to Concrete Filled Steel Tube (콘크리트 충전강관구조(CFT) 적용을 위한 일반강도 콘크리트 물성에 관한 실험적 연구)

  • 강동현;강용학;정근호;김우재;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1071-1076
    • /
    • 2001
  • As a rule, in case of CFT for high-rise building, high strength concrete is required since it should have high fluidity, segregation resistance and large proportion of cement per unit considering the filling beneath the diaphragm. However, regarding the low-rise building under 20 stories, it is somewhat difficult to use high strength concrete. This is a fundamental study to develop a concrete with normal strength and high fluidity for CFT of low-rise building, whose Purposes are in speculating several kinds of changes in concrete's characteristics through various experiments and offering basic documents for practicalization in site and production through mock-up test.

  • PDF

The Result of 2500kW Induction Smelting System Trial Running and Basic Design of 5000kW Induction Smelting System (2500kW 용해설비 시운전 결과 및 5000kW 용해로용 인버터 설계)

  • Yoo Hyo-Yol;Shim Eun-Yong;Jung Dae-Hwhan;Kimm Sang-Jung;Kang Jae-Bong;Kang Ho-Hyun;Kim Wang-Rae
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.288-291
    • /
    • 2006
  • The authors, R&D member of DAWONSYS and Soongsil University, are developing 5000kW smelting inverter system by 2007 under the sponsor from Korea Energy Management Corporation. As a part of the project, 2500kW inverter system has developed in 2005[6], and installed in real production site, and has been running for 7 months successfully. This report deals with the test result of 2500kW smelting inverter system and design for 5000kW smelting inverter system which is final target of this project.

  • PDF

- Development of the multi axis whetstone system in the stone polishing process for the work environment improvement - (작업환경개선을 위한 석재연마공정에 있어서의 다축마석연마장치 개발)

  • Kang Ji Ho;Hong Dong Pyo
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.4
    • /
    • pp.171-181
    • /
    • 2004
  • A multi axis whetstone polishing system, which uses the flow system of the stone polishing machine head, has been developed. The test results show that the defect by line contact polishing does not occur in both ends of the stone and that it came to trim smoothly. In terms of the surface roughness, the corresponding index was decreased by 3.6 times, improving the polishing effect greatly. It decreased significantly the dust and noise with the wet polishing. The factors of the duty evasion at production site can thus be solved with the work environment improvement against the polishing process of the stone industry and work intensive reduction.

A Proposal for Generation of Digital Elevation Models in Korea

  • Lee, Chang-Kyung;Park, Byung-Gil;Kim, Young-An;Min Heo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.02a
    • /
    • pp.73-81
    • /
    • 2004
  • National Geographic Information Institute (NGII) in Korea, through National Geographic Information System (NGIS) Program, has prepared to generate and disseminate digital elevation data for Korea. This is a pilot research to propose a policy for generation, maintenance, and supply of Korea Digital Elevation Data (KDED). Customer demands for accuracy and resolution of DEM was surveyed through questionnaire. In order to investigate the quality, the technical efficiency and the production cost, a tentative DEM in a small test site was generated based on digital topographic maps (original paper map scale 1 :5,000), analytical plotter, and LIDAR. Accuracy standard for KDED was derived based on source data and generation methods. As results of this research, we recommend uniformly spaced grid model for KDED. Its preferable grid space is 5m in urban and its vicinity; and 10m in field and mountainous area. LIDAR has been valuated as a proper KDED generation method fulfilling customers demand for the accuracy.

  • PDF

Proposed Development and Evaluation System for Existing Standardized Waterproof Technology Assessment Methods(Production technology, maintenance evaluation) (표준화된 방수기술 평가기법 개발 및 평가체계 구축 (생산기술, 유지관리 평가 중심))

  • Song, Je-Young;Seo, Hyun-Jae;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.235-236
    • /
    • 2019
  • Waterproofing materials and construction methods have been developed and applied to various construction sites since the past. However, there many cases where the waterproofing performance is not satisfactory, leading to continuous water leakage. It has been observed that a key reason for this is because waterproofing method and material selection is not optimized in terms of the appropriate application area and environmental degradation factors. This paper proposes that future selection of waterproofing methods should consider the following evaluation criteria; 1) waterproof performance evaluation according to site conditions, 2) evaluation of construction method, 3) manufacturing and maintenance of waterproofing systems.

  • PDF

A Study on the Development of Microorganism Test Strips (대장균군 검사용 간이 시험지 개발)

  • 이인애;김재화;이희구;성창근;최인성;정태화
    • Biomedical Science Letters
    • /
    • v.2 no.1
    • /
    • pp.49-55
    • /
    • 1996
  • The objective of this study was to develop a paper strip which could determine E. coli qualitatively and quantitatively in water, wastewater, drinks, or food. This paper strip method was a simple and rapid test method that determine E. coli by visual identification. In this study, nutrient culture media were formulated and characterized for optimum conditions. Paper strips were then prepared by impregnating into the media and dried at $60^\circ$C. The test procedure is quite simple to use. The paper strip was dipped into a sample, and excess sample was removed. The strip was then incubated at $37^\circ$C for 16 to 20 hours and the number of colonies on the strip was counted. The color of the colony spots produced by microorganisms varied depending on the media formulation. Violet-red spots were produced by E. coli. The test method was simple, rapid and no special laboratory equipment was necessary for visual identification. Therefore, this test method is applicable to on-site tests such as field tests or home tests. The paper strip method was compared with the standard agar plate method and Japanese commercial product. The method of the economical preparation of test strips was studied for production on industrial scale.

  • PDF