• Title/Summary/Keyword: Product flow

Search Result 1,154, Processing Time 0.03 seconds

An Estimation of Roughness Coefficient in a Channel with Roughness Correction Blocks (조도보정 블록 수로에서의 조도계수 추정)

  • Choi, Heung Sik;Kim, Si Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.107-116
    • /
    • 2014
  • A volume density of roughness correction blocks in a channel is defined and the corresponding roughness coefficient(n) is estimated by analyzing the diverse hydraulic characteristics of VR, the product of the average velocity and the hydraulic radius, block Reynolds number ($Re^*$), drag coefficient ($\acute{C}_D$), and the roughness coefficient ($n_b$) of bottom shear. The increase of VR and block Reynolds number causes the exponential decrease of roughness coefficient converged to a constant value as expected. The drag coefficient also exponentially decreases as block Reynolds number increases as well. The drag force is governed by the block shape defined by volume density in high block Reynolds number of turbulent flow region. For more accurate estimation of roughness coefficient the use of the correlation equation of it is required by block Reynolds number and volume density. The regression equations for n-VR, $\acute{C}_D-Re^*$, and $n_b-\acute{C}_D$ are presented. The regression equations of roughness coefficient are also presented by block Reynolds number and volume density. The developed equation of roughness coefficient by block Reynolds number and volume density has practical use by confirming the coincidence between the experimental results and the results of HEC-RAS using the developed equation.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

A Study on B Class Fire Extinguishing Performance of Air Ratio in the Compressed Air Foam System (압축공기포 소화설비의 공기포비에 따른 B급 소화성능 연구)

  • Lee, Jang-Won;Lim, Woo-Sub;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.8-14
    • /
    • 2013
  • This research is to evaluate the fire extinguishing performance at a mixing ratio of pressurized air in the fire extinguishing system of compressed air foam (CAF) which injects compressed air into foam liquid and then discharging. The experimental device is made use of exclusive foam extinguishing facility for compressed air foam that is produces based on Canada National Laboratory and UL 162 standard, apply model of oil fire (B Class) 20 unit in accordance with "Standard of Model Approval and Product Inspection for Fire Extinguishing Agent" to the fire Extinguishing model. Compressed air is injected through the air mixture and study the tendency depending on increasing air foam ratio 1 : 4, 1 : 7, 1 : 10. In addition, the comparison experiments between synthetic surfactants foam and AFFF carry out with it at the air foam ratio 1 : 4. As a result, in the condition of same discharging flow, fire extinguishing effect of AFFF is the fastest at the air foam ratio 1 : 7 and the slowest at 1 : 10. Moreover, the fire extinguishing effect of AFFF in the comparison expeiments between AFFF and synthetic surfactants foam is faster than the other.

Development of the DNA Sequencing Chip with Nano Pillar Array using Injection Molding (Nano Pillar Array 사출성형을 이용한 DNA 분리 칩 개발)

  • Kim S.K.;Choi D.S.;Yoo Y.E.;Je T.J.;Kim T.H.;Whang K.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1206-1209
    • /
    • 2005
  • In recent, injection molding process for features in sub-micron scale is under active development as patterning nano-scale features, which can provide the master or stamp for molding, and becomes available around the world. Injection molding has been one of the most efficient processes for mass production of the plastic product, and this process is already applied to nano-technology products successfully such as optical storage media like DVD or BD which is a large area plastic thin substrate with nano-scale features on its surface. Bio chip for like DNA sequencing may be another application of this plastic substrate. The DNA can be sequenced using order of 100 nm pore structure when making the DNA flow through the pore structure. Agarose gel and silicon based chip have been used to sequence the DNA, but injection molded plastic chip may have benefit in terms of cost. This plastic DNA sequencing chip has plenty of pillars in order of 100 nm in diameter on the substrate. When the usual features in case of DVD or BD have very low aspect ratio, even less than 0.5, but the DNA chip will have relatively high aspect ratio of about 2. It is not easy to injection mold the large area thin substrate with sub-micron features on its surface due to the characteristics of the molding process and it becomes much more difficult when the aspect ratio of the features becomes high. We investigated the effect of the molding parameters for injection molding with high aspect ratio nano-scale features and injection molded some plastic DNA sequencing chips. We also fabricated PR masters and Ni stamps of the DNA chip to be used for molding

  • PDF

The Conversion of Methane with Oxygenated Gases using Atmospheric Dielectric Barrier Discharge (배리어방전을 이용한 메탄전환반응에서 함산소 가스가 전환율 및 생성물변화에 미치는 영향)

  • Lee Kwang-Sik;Yeo Yeong-Koo;Choi Jae-Wook;Lee Hwa-Ung;Song Hyung-Keun;Na Byung-Ki
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.52-59
    • /
    • 2006
  • This paper examined the conversion of methane to hydrogen and other higher hydrocarbons using dielectric barrier discharge with AC pulse power. Two metal electrodes of a coaxial-type plasma reactor were separated by gas gap and an alumina tube. The inner electrode was located inside the alumina tube. The alumina tube was located inside the stainless steel tube, which was used as the outer electrode. Effect of feed gas composition (methane, oxygen, argon, water and helium), flow rate, applied frequency, input volt-age on methane conversion and product distribution were studied. The major products of plasma chemical reactions were ethylene, ethane, propane, buthane, hydrogen, carbon monoxide and carbon dioxide. The increment of applied voltage and the usage of inert gas as the background (helium and argon) enhanced the selectivity of hydrocarbons and methane conversion. The addition of water in the feed stream enhanced the conversion of methane and yield of hydrogen. Higher voltage leads to higher yield of $C_2H_6,\;C_3H_8,\;C_4H_{10}$ and yield or $C_2H_2\;and\;C_2H_4$ appeared highly in lower voltage.

The Microbiological Assessment of a University Foodservice Establishment, and Hazard Analysis for Quality Control of Fried Fish Cake Soup Preparation (대학 급식시설의 위생 실태조사 및 품질관리를 위한 연구 - 제 1 보 : 오뎅국을 중심으로 -)

  • Rew, Kyung;Kim, Jeong-Mi;Kwak, Tong-Kyung
    • Journal of Nutrition and Health
    • /
    • v.18 no.4
    • /
    • pp.283-292
    • /
    • 1985
  • A sanitary quality of a university foodservice establishment was assessed in terms of time and temperature, pH and Aw, and microbiological evaluation. Critical control points during various phases in product flow of fried fish cake soup were identified using hazard analysis concept. The results are summarized as follows : 1) Time and temperature data indicated that phases of holding ingredients at room temperature after cooking, and hot - holding of soup before assembly were critical. 2) pH and Aw values were in favorable for microbial growth. 3) Microbiological data indicated that microbial quality of ingredients was in poor condition. A holding practice of cooked ingredients at room temperature might provide the chance for microbial contamination and multiplication. Hot - holding time and temperature of soup should be strictly controlled to assure the food safety, since the microbial quality of serving food can be directly influenced by the hot - holding temperature of soup. 4) Microbiological test results for food containers, equipments, working surfaces, and supplies indicated that sanitary conditions of earthenware, gloves, wiping cloths and cutting board should be improved promptly. 5) Critical control points identified were : ingredients, pre - preparation, post - preparation, and holding before assembly and service. 6) Guidelines for the effective quality control program for this operation were suggested.

  • PDF

IN-LINE NIR SPECTROSCOPY AS A TOOL FOR THE CONTROL OF FERMENTATION PROCESSES IN THE FERMENTED MEATS INDUSTRY

  • Tamburini, Elena;Vaccari, Giuseppe;Tosi, Simona;Trilli, Antonio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3104-3104
    • /
    • 2001
  • The research described here was undertaken with the aim of monitoring, optimizing and ultimately controlling the production of heterofermentative microbes used as starters in the salami industry. The use of starter cultures in the fermented meats industry is a well-established technique used to shorten and standardize the ripening process, and to improve and control the organoleptic quality of the final product. Starter cultures are obtained by the submerged cultivation of suitable microorganisms in stirred, and sometimes aerated, fermenters where monitoring of key physiological parameters such as the concentration of biomass, substrates and metabolites suffers from the general lack of real-time measurement techniques applicable to aseptic processes. In this respect, the results of the present work are relevant to all submerged fermentation processes. Previous work on the application of on-line NIR spectroscopy to the lactic acid fermentation (Dosi et al. - Monreal NIR1995) had successfully used a system based on a measuring cell included in a circulation loop external to the fermenter. The fluid handling and sterility problems inherent in an external circulation system prompted us to explore the use of an in-line system where the NIR probe is immersed in the culture and is thus exposed to the hydrodynamic conditions of the stirred and aerated fluid. Aeration was expected to be a potential source of problems in view of the possible interference of air bubbles with the measurement device. The experimental set-up was based on an in-situ sterilizable NIR probe connected to the instrument by means of an optical fiber bundle. Preliminary work was carried out to identify and control potential interferences with the measurement, in particular the varying hydrodynamic conditions prevailing at the probe tip. We were successful in defining the operating conditions of the fermenter and the geometrical parameters of the probe (flow path, positioning, etc.) were the NIR readings were reliable and reproducible. The system thus defined was then used to construct and validate calibration curves for tile concentration of biomass, carbon source and major metabolites of two different microorganisms used as salami starters. Real-time measurement of such parameters coupled with the direct interfacing of the NIR instrument with the PC-based measurement and control system of the fermenter enabled the development of automated strategies for the interactive optimization of the starter production process.

  • PDF

Experimental Investigation on Cracks and Defects of a Valve Sealing Components for a LPG Cylinder (LPG 용기용 밸브의 밀봉부품 크랙 및 결함에 관한 실험적 고찰)

  • Kim, Chung-Kyun;Lee, Byung-Kwan;Kim, Tae-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.23-28
    • /
    • 2007
  • This paper presents an experimental investigation on the sealing defects and cracks of O-rings and a valve packing of a gas valve for a LPG cylinder. O-ring in which stops a gas leakage of a liquefied petroleum gas is very important for a LPG valve safety. Valve packing is to open and close a gas flow port for supplying and charging a LPG fuel. The sealing performance of two sealing units ism related to the leak safety and long lift of a gas valve. The investigated results show that most of O-rings was failed due to a circumferential crack in which is caused by partial press bonding failure near the partition zone and an excess compression rate. Some of the O-ring failure was originated by an extrusion of an excessive leak pressure of a LP gas. Thus, this paper strongly recommends a tight quality control and a safety guarantee system of O-rings and valve packing to guarantee a leak safety and to extend a service lift of a gas valve. At the end, a warranty policy of the sealing units should be adopted for increasing a product quality and safety of a gas valve.

  • PDF

Development of Slurry Flow Control and Slot Die Optimization Process for Manufacturing Improved Electrodes in Production of Lithium-ion Battery for Electric Vehicles (전기자동차 리튬이온 배터리 제조공정에서 Loading Level 산포최소화 코팅을 통한 전극 품질개선에 관한 연구)

  • Jang, Chan-Hee;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.14-20
    • /
    • 2018
  • Electric vehicles are environmentally friendly because they emit no exhaust gas, unlike gasoline automobiles. However, since they are driven by the electric power from batteries, the distance they can travel based on a single charge depends on their energy density. Therefore, the lithium-ion battery having a high energy density is a good candidate for the batteries of electric vehicles. Since the electrode is an essential component that governs their efficiency, the electrode manufacturing process plays a vital role in the entire production process of lithium-ion batteries. In particular, the coating process is a critical step in the manufacturing of the electrode, which has a significant influence on its performance. In this paper, we propose an innovative process for improving the efficiency and productivity of the coating process in electrode manufacturing and describe the equipment design method and development results. Specifically, we propose a design procedure and development method in order to improve the core plate coating quality by 25%, using a technology capable of reducing the assembly margin due to its high output/high capacity and improving the product capacity quality and assembly process yield. Using this method, the battery life of the lithium-ion battery cell was improved. Compared with the existing coating process, the target loading level is maintained and dispersed to maintain the anode capacity (${\pm}0.4{\rightarrow}{\pm}0.3mg/cm^2r$ reduction).

A Study on GPU Computing of Bi-conjugate Gradient Method for Finite Element Analysis of the Incompressible Navier-Stokes Equations (유한요소 비압축성 유동장 해석을 위한 이중공액구배법의 GPU 기반 연산에 대한 연구)

  • Yoon, Jong Seon;Jeon, Byoung Jin;Jung, Hye Dong;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.597-604
    • /
    • 2016
  • A parallel algorithm of bi-conjugate gradient method was developed based on CUDA for parallel computation of the incompressible Navier-Stokes equations. The governing equations were discretized using splitting P2P1 finite element method. Asymmetric stenotic flow problem was solved to validate the proposed algorithm, and then the parallel performance of the GPU was examined by measuring the elapsed times. Further, the GPU performance for sparse matrix-vector multiplication was also investigated with a matrix of fluid-structure interaction problem. A kernel was generated to simultaneously compute the inner product of each row of sparse matrix and a vector. In addition, the kernel was optimized to improve the performance by using both parallel reduction and memory coalescing. In the kernel construction, the effect of warp on the parallel performance of the present CUDA was also examined. The present GPU computation was more than 7 times faster than the single CPU by double precision.