• 제목/요약/키워드: Process Tomography

검색결과 373건 처리시간 0.025초

Bubbly, Slug, and Annular Two-Phase Flow in Tight-Lattice Subchannels

  • Prasser, Horst-Michael;Bolesch, Christian;Cramer, Kerstin;Ito, Daisuke;Papadopoulos, Petros;Saxena, Abhishek;Zboray, Robert
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.847-858
    • /
    • 2016
  • An overview is given on the work of the Laboratory of Nuclear Energy Systems at ETH, Zurich (ETHZ) and of the Laboratory of Thermal Hydraulics at Paul Scherrer Institute (PSI), Switzerland on tight-lattice bundles. Two-phase flow in subchannels of a tight triangular lattice was studied experimentally and by computational fluid dynamics simulations. Two adiabatic facilities were used: (1) a vertical channel modeling a pair of neighboring sub-channels; and (2) an arrangement of four subchannels with one subchannel in the center. The first geometry was equipped with two electrical film sensors placed on opposing rod surfaces forming the subchannel gap. They recorded 2D liquid film thickness distributions on a domain of $16{\times}64$ measuring points each, with a time resolution of 10 kHz. In the bubbly and slug flow regime, information on the bubble size, shape, and velocity and the residual liquid film thickness underneath the bubbles were obtained. The second channel was investigated using cold neutron tomography, which allowed the measurement of average liquid film profiles showing the effect of spacer grids with vanes. The results were reproduced by large eddy simulation + volume of fluid. In the outlook, a novel nonadiabatic subchannel experiment is introduced that can be driven to steady-state dryout. A refrigerant is heated by a heavy water circuit, which allows the application of cold neutron tomography.

Radiological assessment and follow-up of a nonsurgically treated odontoid process fracture after a motor vehicle accident in Egypt: a case report

  • Ahmad Mokhtar Abodahab
    • Journal of Trauma and Injury
    • /
    • 제36권4호
    • /
    • pp.411-415
    • /
    • 2023
  • An odontoid process fracture is a serious type of cervical spine injury. This injury is categorized into three types based on the location of the fracture. Severe or even fatal neurological deficits can occur due to associated cord injury, which can result in complete quadriplegia. Computed tomography is the primary diagnostic tool, while magnetic resonance imaging is used to evaluate any associated cord injuries. These injuries can occur either directly from the injury or during transportation to the hospital if mishandled. There are two main treatment approaches: surgical fixation or external nonsurgical fixation, with various types and models of fixation devices available. In this case study, computed tomography follow-up confirmed that external fixation can yield successful results in terms of complete healing, even in cases complicated by other factors that may impede healing, such as pregnancy.

흉부 전산화 단층촬영을 이용한 혈흉의 정량분석 (Quantitative analysis of hemothorax by computed tomography)

  • 강청희
    • Journal of Chest Surgery
    • /
    • 제28권3호
    • /
    • pp.228-232
    • /
    • 1995
  • Computed tomography[CT is an effective technique for the evaluation of the thorax following blunt trauma. To evaluate multiply injured 30 patients who were diagnosed as hemothorax in emergency room, computed tomography of thorax was done. The thickness of slice was one centimeter and the entire pleural cavity from the apex to the costophrenic angle was included in the evaluation. Integration and addition of the hemothorax area for each CT slice was made and amount of blood in the pleural cavity was estimated. The slice which showed largest area of hemothorax was selected and the height and width of the hemothorax area were measured. The number of slices which showed radiographic evidence of hemothorax was counted. Regression analysis was done and measured amount of hemothorax, the height and width of the hemothorax area for each slice and number of slices were put as variables. And following equation was derived. V=108.3A-0.8B-7.4C+84.7 [R2=0.74 [ V: amount of hemothorax, A: height, B: width, C: number of slices Total amount of blood from thoracic drainage was compared to the measured amount by computed tomography and the relation between the two values was statistically significant.[p=0.001 In conclusion, quantitative estimation of size of hemothorax was possible by the above equation and the process was very helpful for determination policy of treatment of individual patient.

  • PDF

전산화단층 촬영상의 임계치가 3차원 의학모델 정확도에 미치는 영향에 대한 연구 (Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model)

  • 이병도;이완
    • Imaging Science in Dentistry
    • /
    • 제32권1호
    • /
    • pp.27-33
    • /
    • 2002
  • Purpose: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model Material and Methods : CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works/sup TM/ 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. Results: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm (2.52%) between linear measurements of dry skull and 800 RP model. Conclusion: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.

  • PDF

개의 비강 편평상피세포종의 컴퓨터단층촬영상의 특징 (Computed Tomographic Characteristics Of Nasal Squamous Cell Carcinoma In a Dog)

  • 권정국;송경진;이기창;이희천;최민철
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.399-402
    • /
    • 2003
  • A female unknown aged Yorkshire terrier, weighing 3.5 kg with nasal discharge, left facial swelling and severe inflammation was referred to Veterinary Medical Teaching Hospital, Seoul National University. Radiographic findings were lytic change and soft tissue swelling of left zygomatic process and increased radiopacity of nasal cavity. In computed tomography, turbinate bone destruction was observed as well as lytic change of left zygomatic process and left maxilla indicating aggressive lesion. Then 3-dimensional reconstruction was also performed. Biopsy of tissue mass revealed it as squamous cell carcinoma. For this patient, euthanasia was performed guarded prognosis. Generally, tumors of the nasal cavity in dogs account for approximately 1 % to 2% of all neoplasms. The prevalence of these tumors increased with age and exposure to the ultraviolet. About two thirds of all nasal tumors are malignant tumors such as squamous cell carcinoma and adenocarcinoma. As these tumors of nasal cavity are locally invasive, and external beam radiotherapy is the current treatment of choice. Unfortunately, diagnosis of these tumors often occurs late in the course of disease, resulting in a poor prognosis for outcome in many patients. It is considered that computed tomography could be used as an aid modality for the exact evaluation of extend and degree of bone lysis of nasal cavity and metastasis.

투과 컴퓨터 단층촬영을 위한 모델 기반 반복연산 재구성에서 투사선 구동 시스템 모델의 성능 비교 (Performance Comparison of Ray-Driven System Models in Model-Based Iterative Reconstruction for Transmission Computed Tomography)

  • 정지은;이수진
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.142-150
    • /
    • 2014
  • The key to model-based iterative reconstruction (MBIR) algorithms for transmission computed tomography lies in the ability to accurately model the data formation process from the emitted photons produced in the transmission source to the measured photons at the detector. Therefore, accurately modeling the system matrix that accounts for the data formation process is a prerequisite for MBIR-based algorithms. In this work we compared quantitative performance of the three representative ray-driven methods for calculating the system matrix; the ray-tracing method (RTM), the distance-driven method (DDM), and the strip-area based method (SAM). We implemented the ordered-subsets separable surrogates (OS-SPS) algorithm using the three different models and performed simulation studies using a digital phantom. Our experimental results show that, in spite of the more advanced features in the SAM and DDM, the traditional RTM implemented in the OS-SPS algorithm with an edge-preserving regularizer out-performs the SAM and DDM in restoring complex edges in the underlying object. The performance of the RTM in smooth regions was also comparable to that of the SAM or DDM.

Coronoid Process Hyperplasia: A Rare Case of Restricted Mouth Opening Masquerading as Temporomandibular Disorder

  • Juhyun Cha;Jin Woo Chung
    • Journal of Oral Medicine and Pain
    • /
    • 제48권3호
    • /
    • pp.112-117
    • /
    • 2023
  • Coronoid process hyperplasia (CPH) of the mandible is a rare condition in which abnormal elongation of the coronoid process leads to chronic mandibular hypomobility. CPH causes impingement or impedance of the coronoid process on the inner surface of the frontal part of the zygomatic bone during mouth opening. The lack of significant symptoms makes the diagnosis difficult. Its etiology remains inconclusive despite several theories being suggested. In this report, three reviewed cases are presented. All three patients visited our clinic with limited mouth opening as the chief complaint. Standard clinical and radiographic examinations were conducted under the initial impression of temporomandibular disorders (TMDs), and restricted jaw movements were confirmed in all cases. The absence of improved signs and symptoms following conservative treatment for TMDs or the indeterminate plain radiographs required the attending clinicians to consider three-dimensional imagery. Computed tomography revealed bilateral coronoid hyperplasia in all cases and impingement on the zygomatic bone in two of the three cases. After concluding that this condition caused the patients' limited mouth opening, the patients were referred to the Department of Oral and Maxillofacial Surgery for possible bilateral coronoidectomy or coronoidotomy. CPH usually presents no symptoms apart from a progressive reduction of mouth opening over time. Diagnosis is often delayed, and patients may undergo unnecessary treatment procedures. Clinicians should be aware of this condition and exercise caution in the differential diagnosis of patients with chronic mandibular hypomobility.

Comparison of interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns using cone-beam computed tomography

  • Khumsarn, Nattida;Patanaporn, Virush;Janhom, Apirum;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.117-125
    • /
    • 2016
  • Purpose: This study evaluated and compared interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns, using cone-beam computed tomography (CBCT). Materials and Methods: Pretreatment CBCT images of 24 Thai orthodontic patients with Class I and Class II skeletal patterns were included in the study. Three measurements were chosen for investigation: the mesiodistal distance between the roots, the width of the buccolingual alveolar process, and buccal cortical bone thickness. All distances were recorded at five different levels from the cementoenamel junction (CEJ). Descriptive statistical analysis and t-tests were performed, with the significance level for all tests set at p<0.05. Results: Patients with a Class II skeletal pattern showed significantly greater maxillary mesiodistal distances (between the first and second premolars) and widths of the buccolingual alveolar process (between the first and second molars) than Class I skeletal pattern patients at 10 mm above the CEJ. The maxillary buccal cortical bone thicknesses between the second premolar and first molar at 8 mm above the CEJ in Class II patients were likewise significantly greater than in Class I patients. Patients with a Class I skeletal pattern showed significantly wider mandibular buccolingual alveolar processes than did Class II patients (between the first and second molars) at 4, 6, and 8 mm below the CEJ. Conclusion: In both the maxilla and mandible, the mesiodistal distances, the width of the buccolingual alveolar process, and buccal cortical bone thickness tended to increase from the CEJ to the apex in both Class I and Class II skeletal patterns.

전자기 토모그래피를 이용한 액체 금속 속도장 측정 (Measurement of velocity Pronto in Liquid Metal Flow Using Electromagnetic Tomography)

  • 안예찬;김무환;최상호
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1271-1278
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output fur a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was 54$^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

EZTOMO 시추공 토모그래피 소프트웨어 시스템 보완 (EZTOMO CROSSWELL TOMOGRAPHY SOFTWARE SYSTEM UPDATE)

  • 이두성
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.69-72
    • /
    • 2008
  • EZTOMO는 시추공 주시토모그래피 소프트웨어 시스템이다. 이 시스템은 초동발췌, 파선추적, 역산, 오차분석 및 시각화 기능을 보유하고 있다. 이 연구에서는 시스템의 초동발췌 와 역산법을 개선 보완하였다. 초동의 파형정보를 사용한 초동발췌 방법과 초동신호의 S/N(신호 대 잡음비)을 사용한 역산법의 보완이다.

  • PDF