• 제목/요약/키워드: Process Performance Measurement

검색결과 1,003건 처리시간 0.025초

일 대학의 간호교육목표 달성도 평가를 위한 간호실무능력 평가도구 개발 (Development of the Nursing Practice Capacity Scale for Evaluating Achievement of Nursing Education Objectives)

  • 현명선;유문숙;송미숙;박진
    • 가정간호학회지
    • /
    • 제22권2호
    • /
    • pp.246-255
    • /
    • 2015
  • Purpose: The study was conducted to develop the Nursing Practice Capacity scale for evaluating achievement of education objectives among students in nursing school. Methods: This was a methodological study. The scale development process included generation of initial items, verification of content validity, selections of secondary items, preliminary study, and extraction of final items. The participants were five graduates 1 to 4 years after graduation (for the preliminary study) and 125 graduates 1 to 4 years after graduation from the nursing school at A University, South Korea. Item analysis, criterion validity, and internal consistency were used to analyze the data. Results: Twenty-six items were selected for the final scale. The scores on the scale were significantly correlated with the Nursing Competency Scale(r=.62, p<.001) and Nursing Performance Scale(r=.63, p<.001). Chronbach's alpha coefficient for the 26 items was .87. Conclusion: The Nursing Practice Capacity scale for evaluating achievement of nursing education objectives has good validity and reliability. The measurement scale can be useful for evaluating the nursing practice capacity of nurses as well as measuring the extent to which graduates have achieved the established education objectives in the education fields.

천연가스의 열용량을 측정하기 위한 촉매가스센서의 특징 (Characterization of A Catalystic Gas Sensor for Measuring Heat Content of Natural Gas)

  • 이기용
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.1-6
    • /
    • 1998
  • 전력을 적재 소모하는 (300 mW 이하) 촉매가스센서가 개발되었고, 천연가스에 열용량을 측정하기 위해 컴퓨터로 작동되는 샘플링 시스템에 사용되었다. 가스의 열용량은 촉매자스센서가 감지되는 연소가스에 노출되었을 때 발생된 에너지에 비례된다. 36.30 - 39.88 $MJ/m^3$ 범위의 정격 열용량을 갖는 천연가스의 열용량은 약 $1\%$ 에러 내에서 측정되었다. 각 가스들은 센서의 온도에 대하여 약간씩 다른 감응곡선을 갖고 있다. 따라서 한 온도에서 모든 감응이 같을 수는 없다. 작동 온도는 측정장치의 전 성능에 영향을 미치기 때문에 교정과정에서 최적의 작동 온도를 찾는 것은 중요하다.

  • PDF

개선된 이진화와 형상분석 기법을 응용한 콘크리트 표면 균열의 화상처리 알고리즘 개발 (Development of Image Processing for Concrete Surface Cracks by Employing Enhanced Binarization and Shape Analysis Technique)

  • 이방연;김윤용;김진근
    • 콘크리트학회논문집
    • /
    • 제17권3호
    • /
    • pp.361-368
    • /
    • 2005
  • 이 연구의 목적은 디지털 카메라나 비디오 카메라로 촬영된 콘크리트 표면 균열 화상에서 컴퓨터가 자동으로 균열을 검출하고 균열의 폭, 길이, 방향을 계산할 수 있는 알고리즘을 개발하는 것이다. 개발한 알고리즘의 기본 구조는 기존의 연구 결과들과 유사하며, 기존 연구들과의 차이점은 다음과 같다 (1) 빈의 영향을 제거하기 위한 모폴로지 기법의 적용, (2) 개선된 이진화 기법과 형상 분석을 통한 검출 성능 향상, (3) 폭, 길이, 방향 계산을 위한 세부 알고리즘을 제시한 것이다. 제시한 알고리즘의 유효성을 검증하기 위하여 MATLAB 언어를 이용하여 알고리즘을 구현하였으며, 디지털 카메라를 통하여 얻은 실제 균열 화상을 사용하여 시험하였다. 시험결과는 제시한 알고리즘이 균열을 정확히 검출할 수 있음을 나타냈으며, 이 연구에서 제시한 방법으로 계산한 균열의 폭, 길이, 그리고 방향의 값을 균열 폭 측정 현미경, 자, 그리고 각도기로 계측한 값과 비교한 결과 거의 일치된 결과가 나타났다.

LCD 구동 IC를 위한 Power-Up 순차 스위치를 가진 Latch-Up 방지 기술 (Latch-Up Prevention Method having Power-Up Sequential Switches for LCD Driver ICs)

  • 최병호;공배선;전영현
    • 대한전자공학회논문지SD
    • /
    • 제45권6호
    • /
    • pp.111-118
    • /
    • 2008
  • 액정 구동 IC에서 발생하는 기생 p-n-p-n 회로의 래치업 문제를 개선하기 위해 power-up 순서상에 순차 스위치를 삽입하는 방법을 제안하였다. 제안된 순차 스위치는 2차-승압회로와 3차-승압회로 내에 삽입되며, power-up 순서상에서 해당 승압회로가 동작하기 전에 기생 p-n-p-n 회로의 분리된 에미터-베이스 단자를 순차적으로 연결하게 된다. 제안된 구조의 성능을 검증하기 위해 0.13-um CMOS 공정을 이용하여 테스트 IC를 설계 제작하였다 측정 결과, 기존의 경우 $50^{\circ}C$에서 액정 구동 전압이 VSS로 수렴하면서 과전류를 동반하며 래치업 모드로 진입하였으나, 제안 회로를 삽입한 경우는 고온($100^{\circ}C$)에서도 정상 전류 0.9mA와 정상 액정 구동 전압을 나타내어 래치업이 방지되고 있음을 확인하였다.

위성통신용 MSM을 위한 흡수형 SPST MMIC 스위치의 설계 및 제작 (Design of Absorptive Type SPST MMIC Switch for MSM of Satellite Communication)

  • 염인복;류근관;신동환;이문규;오일덕;오승엽
    • 한국전자파학회논문지
    • /
    • 제16권10호
    • /
    • pp.989-994
    • /
    • 2005
  • 위성통신 시스템의 초고주파 스위치 메트릭스(MSM)를 위한 MMIC 스위치 칩을 InGaAs/GaAs p-HEMT 공정을 이용하여 설계 및 제작하였다. MMIC 스위치는 on과 off상태에서 우수한 입출력 반사계수를 위해 흡수형으로 설계되었다. 또한, 스위치 칩의 크기를 줄이기 위해 MIM 커패시터와 spiral 인덕터의 집중소자를 이용하여 3 GHz 대역에서의 ${\lambda}/4$ 임피던스 변환기를 구현하였다. 설계된 MMIC 스위치는 $3.2\~3.6\;GHz$ 대역에서 사용할 수 있으며 $1.6\;mm{\times}1.3\;mm$의 칩 크기를 갖는다. On-wafer 측정 결과, 2 dB 이하의 삽입 손실과 56.8 dB 이상의 격리도 특성을 나타내었다. 이와 같은 측정 결과는 시뮬레이션 결과와 잘 일치하는 것이다.

핵의학 영상기기의 최근 진보 (Recent Advances in Nuclear Medicine Imaging Instrumentation)

  • 정진호;최용;홍기조;민병준;호위;강지훈
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.

초음파 가스 유량계 개발과 활용 (Development and Application of an Ultrasonic Gas Flowmeter)

  • 황원호;박상국;정희돈;장경영
    • 비파괴검사학회지
    • /
    • 제22권3호
    • /
    • pp.246-253
    • /
    • 2002
  • 제철공정에서 발생하는 열악한 환경의 가스를 계측하기 위해서 개발한 초음파 가스 유량계와 현장 적용 결과에 대해서 기술한다. 개발된 초음파 유량계는 제철공정에 생산되는 부생가스인 LDG, COG, BFG 등의 활용에 적합하도록 개발했다. 그리고 본 초음파 유량계는 초음파 전달시간차 방식을 채택하고 있다. 전달 시간차 방식의 초음파 유량계를 구현하기 위한 초음파 신호의 송수신 알고리즘 및 초음파 신호처리 알고리즘을 개발했다. 유량계의 성능을 검증하기 위해서 대용량 유량 검 교정 장치를 자체 제작하여 유량계 검 교정 실험을 행했고 Venturi Type의 기준유량계와 비교실험을 통해서 측정오차를 평가했다. 실제 제철공정에 1년 이상의 적용 테스터를 통해 초음파 유량계의 신뢰성을 확인했으며 현재 상업화 모델이 개발되어 현장에서 활용 중에 있다.

식스 시그마 기법을 활용한 고밀도 정보저장 매체 개발 (Development of High-Density Information Storage Media by Employing the Six Sigma Methodology)

  • 이명복
    • 한국융합학회논문지
    • /
    • 제9권9호
    • /
    • pp.41-46
    • /
    • 2018
  • 식스 시그마 기법은 제품과 서비스의 품질관리와 원가 절감을 통한 생산성 향상 뿐만 아니라, 연구개발을 비롯한 기업 경영의 다양한 영역에 적용할 수 있는 관리 기법이다. 또한 정보 융합 시대의 실현을 위하여 고밀도 정보저장 매체 및 장치의 개발은 필수적 요건이다. 본 논문에서는 고밀도 정보저장 매체 개발 과제에 식스 시그마 방법론과 기법을 적용한 사례에 대하여 보고하고자 한다. 식스 시그마 프로세스는 표준적으로 사용되는 DMAIC 프로세스를 적용하였으며 각 단계별로 달성하고자 하는 목표와 적용한 도구 및 결과에 대하여 상세히 설명하였다. 본 기법을 활용함으로써 $250Gb/in^2$ 이상의 높은 기록밀도를 갖는 정보저장 매체를 균일하고 재현성 있게 형성할 수 있는 제조 방법을 확립하였으며, 제조된 매체의 자기적 특성과 성능을 자기이력곡선을 통하여 확인하였다.

Twin-well Non-epitaxial CMOS Substrate에서의 노이즈 분석을 위한 Substrate Resistance 및 Guard-ring 모델링 (A Substrate Resistance and Guard-ring Modeling for Noise Analysis of Twin-well Non-epitaxial CMOS Substrate)

  • 김봉진;정해강;이경호;박홍준
    • 대한전자공학회논문지SD
    • /
    • 제44권4호
    • /
    • pp.32-42
    • /
    • 2007
  • [ $0.35{\mu}m$ ]twin-well non-epitaxial CMOS 공정에서의 substrate noise에 의한 아날로그 회로의 성능 저하를 예측하기 위하여 substrate 저항을 모델링하였다. Substrate 저항 모델 방정식은 P+ guard-ring isolation에 적용되어 측정값과 일치함을 확인하였다. Substrate 저항을 네 가지 형태로 구분하고 각각에 대하여 semi-empirical 모델 방정식을 확립하여, 측정값과 비교하여 rms 오차가 10% 미만이 되었다. 이 substrate 저항 모델을 guard-ring에 의한 isolation 구조에 적용하기 위하여 모델 방정식과 ADS(Advanced Design System) 회로 시뮬레이션에 의한 결과와 Network Analyzer의 측정 결과를 비교하였고, 비교적 잘 일치함을 확인하였다.

이층 기판용 3 dB 커플러 (A 3 dB Coupler for Double Sided Printed Circuit Boards)

  • 이동호
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.559-565
    • /
    • 2014
  • 가장 많이 쓰이는 FR4 이층 기판을 사용하여 3 dB 커플러를 설계하고 제작하였다. 커플러 일부의 겹치는 면적을 키워서 커플링을 증가시키고 대역폭을 증가시키는 구조를 제안하였다. 설계를 위한 주요 파라미터 값들을 여러 조건에 따라 도시하였고, 시뮬레이션과 측정을 통해 검증하였다. 제작된 커플러의 크기는 $30{\times}14mm^2$이고, 중심 주파수 2.5 GHz 에서 0.6 dB의 삽입 손실과 $90.5^{\circ}$의 위상차를 측정으로부터 얻었다. 측정된 삽입 손실 $3.6{\pm}0.5dB$에 대한 주파수 범위는 1.72 GHz에서 3.08 GHz이다. 제안한 커플러는 기존의 랭 커플러와 유사한 성능을 보였고, 와이어 본딩 공정이 필요 없어 추가 비용이 들지 않고 도선의 폭과 간격이 넓어서 제작이 용이하다.