• 제목/요약/키워드: Procedure time

검색결과 5,457건 처리시간 0.034초

A Special Case of Three Machine Flow Shop Scheduling

  • Yang, Jaehwan
    • Industrial Engineering and Management Systems
    • /
    • 제15권1호
    • /
    • pp.32-40
    • /
    • 2016
  • This paper considers a special case of a three machine flow shop scheduling problem in which operation processing time of each job is ordered such that machine 1 has the longest processing time, whereas machine 3, the shortest processing time. The objective of the problem is the minimization of the total completion time. Although the problem is simple, its complexity is yet to be established to our best knowledge. This paper first introduces the problem and presents some optimal properties of the problem. Then, it establishes several special cases in which a polynomial-time optimal solution procedure can be found. In addition, the paper proves that the recognition version of the problem is at least binary NP-complete. The complexity of the problem has been open despite its simple structure and this paper finally establishes its complexity. Finally, a simple and intuitive heuristic is developed and the tight worst case bound on relative error of 6/5 is established.

An Overview of Time Estimation in the Appraisal of Completeness for Software

  • Kim, Yukyong
    • 한국소프트웨어감정평가학회 논문지
    • /
    • 제16권1호
    • /
    • pp.21-26
    • /
    • 2020
  • The completeness appraisal of software is performed in various forms, such as assessing the completion level in the development process, calculating the defect rate, estimating the development cost, and calculating the redevelopment cost. Along with this, the problem that is often dealt with is estimation of the development time. Even in a dispute over completeness due to delays in software development, issues of calculating an appropriate development time required to develop a delivery software or a development time required for change requests are often included in the appraisal request. In this paper, we introduce the procedure and method for estimating the appropriate project time of software development so that the appraiser can be applied to the appraisal work for determining the completeness. The method is based on the manual for calculating the appropriate project period of software development project.

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials

  • Hieu, Pham-Duong;Chung, Jin-Hyung;Yim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • 제40권1호
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: The performance of implant surgery in the posterior maxilla often poses a challenge due to insufficient available bone. Sinus floor elevation was developed to increase the needed vertical height to overcome this problem. However, grafting materials used for the sinus lift technique eventually show resorption. The present study radiographically compared and evaluated the changes in height of the grafting materials after carrying out maxillary sinus elevation with a window opening procedure. This study also evaluated the difference between two xenogenic bone materials when being used for the sinus lifting procedure. Methods: Twenty-one patients were recruited for this study and underwent a sinus lift procedure. All sites were treated with either bovine bone (Bio-$Oss^{(R)}$) with platelet-rich plasma (PRP) or bovine bone (OCS-$B^{(R)}$)/PRP. A total of 69 implants were placed equally 6-8 months after the sinus lift. All sites were clinically and radiographically evaluated right after the implant surgery, 7-12 months, 13-24 months, and 25-48 months after their prosthetic loading. Results: Changes of implant length/bone length with time showed a statistically significant decreasing tendency (P<0.05). There was no significant change in the Bio-$Oss^{(R)}$ group (P>0.05). In contrast, the OCS-$B^{(R)}$ group showed a significant decrease with time (P<0.05). However, no significant difference was observed between the two groups (P>0.05). Conclusions: The results showed that there was significant reduction in comparison with data right after placement, after 7 to 12 months, 13 to 24 months, and over 25 months; however, reduction rates between each period have shown to be without significance. No significant difference in height change was observed between the Bio-$Oss^{(R)}$ and the OCS-$B^{(R)}$ groups.

진화론적 최적 자기구성 다항식 뉴럴 네트워크 (Genetically Optimized Self-Organizing Polynomial Neural Networks)

  • 박호성;박병준;장성환;오성권
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권1호
    • /
    • pp.40-49
    • /
    • 2004
  • In this paper, we propose a new architecture of Genetic Algorithms(GAs)-based Self-Organizing Polynomial Neural Networks(SOPNN), discuss a comprehensive design methodology and carry out a series of numeric experiments. The conventional SOPNN is based on the extended Group Method of Data Handling(GMDH) method and utilized the polynomial order (viz. linear, quadratic, and modified quadratic) as well as the number of node inputs fixed (selected in advance by designer) at Polynomial Neurons (or nodes) located in each layer through a growth process of the network. Moreover it does not guarantee that the SOPNN generated through learning has the optimal network architecture. But the proposed GA-based SOPNN enable the architecture to be a structurally more optimized network, and to be much more flexible and preferable neural network than the conventional SOPNN. In order to generate the structurally optimized SOPNN, GA-based design procedure at each stage (layer) of SOPNN leads to the selection of preferred nodes (or PNs) with optimal parameters- such as the number of input variables, input variables, and the order of the polynomial-available within SOPNN. An aggregate performance index with a weighting factor is proposed in order to achieve a sound balance between approximation and generalization (predictive) abilities of the model. A detailed design procedure is discussed in detail. To evaluate the performance of the GA-based SOPNN, the model is experimented with using two time series data (gas furnace and NOx emission process data of gas turbine power plant). A comparative analysis shows that the proposed GA-based SOPNN is model with higher accuracy as well as more superb predictive capability than other intelligent models presented previously.

수족부 연부조직 결손의 재건에 있어서 지방근막피판술의 유용성 (Versatility of Adipofascial Flap for the Reconstruction of Soft Tissue Defect on Hand or Foot)

  • 천남주;김철한;신호성;강상규;탁민성
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.759-764
    • /
    • 2007
  • Purpose: Various types of flaps, with their own advantages and disadvantages, have been described for reconstruction of soft tissue defect with exposure of tendons, bones, or joints in the hand or foot. Local flaps with random vascularity have a limitation by their length. Free flaps are time-consuming procedure that may require the sacrifice of some major vessels. The ideal flap for covering soft tissue defects of the hand or foot must provide subcutaneous tissue that tendons can glide through which, supply enough subcutaneous tissue for cover of vital neural, bony, vascular and joint structures, and it has to be aesthetically pleasing. The adipofascial flap fulfills these criteria. It allows immediate or early closure of difficult wound of hand and foot in an easy way, and is especially indicated for small to medium-sized defects. Methods: From October 2005 to December 2006, seven cases underwent this procedure to reconstruct soft tissue defect on hand or foot. Results: All flaps survived completely, and no complications were observed. Conclusion: The adipofascial flap is a convenient flap for coverage of soft tissue with exposure of vital structure in the hand or foot, and provide several advantages, as following; easy and safe, short operating time, one stage procedure, thinness and good pliability of the flap, preservation of the major vascular pedicles, skin preservation at the donor site, thus preserve the shape of the limb and minimize donor site scar.

Internal-External Percutaneous Transhepatic Biliary Drainage for Patients with Malignant Obstructive Jaundice

  • Xu, Chuan;Lv, Peng-Hua;Huang, Xin-En;Sun, Ling;Wang, Shu-Xiang;Wang, Fu-An
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권21호
    • /
    • pp.9391-9394
    • /
    • 2014
  • Purpose: To evaluate the effect of internal-external percutaneous transhepatic biliary drainage (IEPTBD) for patients with malignant obstructive jaundice. Methods: During the period of January 2008 and July 2013, internal-external drainage was performed in 42 patients with malignant obstructive jaundice. During the procedure, if the guide wire could pass through the occlusion and into the duodenum, IEPTBD was performed. External drainage biliary catheter was placed if the occlusion was not crossed. Newly onset of infection, degree of bilirubin decrease and the survival time of patients were selected as parameters to evaluate the effect of IEPTBD. Results: Twenty newly onset of infection were recorded after procedure and new infectious rate was 47.6%. Sixteen patients with infection (3 before, 13 after drainage) were uncontrolled after procedure, 12 of them (3 before, 9 after drainage) died within 1 month. The mean TBIL levels declined from 299.53 umol/L before drainage to 257.62 umol/L after drainage, while uninfected group decline from 274.86 umol/L to 132.34 umol/Lp (P < 0.5). The median survival time for uninfected group was 107 days, and for infection group was 43 days (P < 0.05). Conclusions: The IEPTBD drainage may increase the chance of biliary infection, reduce bile drainage efficiency and decrease the long-term prognosis, and the external drainage is a better choice for patients with malignant obstructive jaundice need to biliary drainage.

Gait analysis on the condition of arm swing in healthy young adults

  • Koo, Hyun-Min;Lee, Su-Young
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.149-154
    • /
    • 2016
  • Objective: The arm swing is associated with gait ability in healthy young adults. The purpose of this study was to examine the effects of arm swing during gait in healthy young adults. Design: Cross-sectional study. Methods: Forty-five subjects without any orthopedic or neurological injuries participated in this study. All subjects performed all three conditions according to the arm swing type as follows: first procedure (condition 1), walking as usual without arm swing constraint; second procedure (condition 2), constraint of dominant arm swing walking as usual; third procedure (condition 3), constraint of both arm swing walking as usual. Gait parameters such as gait velocity, stride length, cadence, step time, single limb support, and double limb support were measured in all arm swing conditions performed randomly, with the mean value obtained from three measurements. A rest period of 5 minutes was given to prevent repetition of each condition and learning effect. All data was analyzed using repeated measures ANOVA to notice the changes between arm swing conditions. Results: Within walking conditions, significant difference of gait velocity, stride length, cadence, and double limb support was noticed (p<0.05), except step time and single limb support. Gait velocity and stride length were significant reduced, and in cadence and double limb support were increased (p<0.05). Condition 3 had the most significant decrease of gait ability compared with condition 1 (p<0.05). Conclusions: These finding suggested that constraint arm swing conditions reduced gait ability in healthy young adults. Also, these findings can be utilized as a reference to future studies that not only pelvic, knee and ankle, but also upper limb affect to gait ability.

성견에서 차단막/골이식재 복합체를 이용한 임플란트 주위 골유도재생 효과: 임상적, 방사선학적, 조직학적 평가 (Local ridge augmentation using a composite of bone substitute and collagen membrane at peri-implant dehiscence defects: a clinical, radiographic and histological analyses.)

  • 송영우;윤소라;차재국;이중석;최성호;정의원
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.676-687
    • /
    • 2017
  • Objectives : The aim of this study was to evaluate the effects of a composite of bone substitute and collagen barrier membrane (bone patch) for local ridge augmentation at peri-implant dehiscence defects on the clinical efficacy and positional stability in dogs. Materials and methods : Implant placement and ridge augmentation procedure were performed at surgically created peri-implant dehiscence defects in canine mandible (n=6). Four treatment modalities were randomly applied: i) bone patch group, ii) Guided bone regeneration (GBR) without pin fixation group (bone graft and collagen membrane), iii) GBR with pin fixation group, and iv) negative control group. After 12 weeks, clinical, micro-CT and histological analyses were performed. Results : Histologic analysis showed that bone patch group had similar results to GBR group and GBR with fixation group in terms of new bone formation. Micro-CT analysis revealed similar results to histologic analysis in terms of total volume maintenance. Operating time was shorter in bone patch group compared to GBR group and GBR with fixation groups. Conclusions : GBR using bone patch could simplify the ridge augmentation procedure with reduced operating time and equivalent biological performance compared to the conventional procedure.

  • PDF

Giga-Bit급 DRAM을 위한 고유전 $(Ba,Sr)Tio_3$박막 커패시터의 유전완화 특성에 대한 회로 모델 (A Circuit Model of the Dielectric Relaxation of the High Dielectric $(Ba,Sr)Tio_3$ Thin Film Capacitor for Giga-Bit Scale DRAMs)

  • 장병탁;차선용;이희철
    • 대한전자공학회논문지SD
    • /
    • 제37권4호
    • /
    • pp.15-24
    • /
    • 2000
  • 고유전 커패시터의 유전완화 특성은 시간영역에서 나타나는 커패시터의 동적특성으로 이해될 수 있으며 이것은 DRAM의 재충전 시간동안 충전된 전하를 잃어버리는 가장 주된 요인으로 인식된다. 그러므로 DRAM 동작에 미치는 영향을 고려하기 위하여 고유전 커패시터의 유전완화에 대한 등가회로를 만드는 것이 필수적이다. 그러나 아직까지 등가회로를 만들 수 있는 일반적이고 이론적인 방법이 제시되지 않고 있다. 근 본 연구에서는 고유전 커패시터의 등가회로를 주파수 영역에서 모델링하는 새로운 방법을 개발하였다. 이 방법은 이론적인 체계를 갖춘 일반적인 방법이다. 또한, 본 연구에서는 실험과정을 통해서 이 방법의 타당성으로 확인하였고, 궁극적으로 새로운 방법으로 얻어진 등가회로를 활용하여 유전완화가 DRAM 동작에 미치는 영향을 고찰하였다.

  • PDF