• Title/Summary/Keyword: Procedure time

Search Result 5,413, Processing Time 0.03 seconds

Time accurate method for low speed compressible flows using dual time stepping and preconditioning procedure (이중 시간전진법과 Preconditioning을 이용한 저속의 압축성유동에 대한 비정상 해석기법)

  • Choe, Yun-Ho;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.788-802
    • /
    • 1998
  • A numerical method using dual time stepping and preconditioning procedure for efficient computations of unsteady low speed compressible flow problems is developed. The time-derivative preconditioning method which is valid at low speed flow conditions cannot maintain temporal accuracy because of the modification of the time-derivative term in Navier-Stokes equations. The dual time stepping procedure is incorporated to enable the time accurate computations and this procedure introduces a pseudo-time derivative in addition to the physical time derivative. At a given physical time, an inner iteration can be carried out until a steady state in pseudo-time is achieved. This will effectively yield a time accurate solution. Computational capabilities of the above algorithm are demonstrated through computation of a variety of practical fluid flows and it is shown that the algorithms is efficient in the essentially incompressible flows and low Mach number compressible flows with heat source.

Combining Regression Model and Time Series Model to a Set of Autocorrelated Data

  • Jee, Man-Won
    • Journal of the military operations research society of Korea
    • /
    • v.8 no.1
    • /
    • pp.71-76
    • /
    • 1982
  • A procedure is established for combining a regression model and a time series model to fit to a set of autocorrelated data. This procedure is based on an iterative method to compute regression parameter estimates and time series parameter estimates simultaneously. The time series model which is discussed is basically AR(p) model, since MA(q) model or ARMA(p,q) model can be inverted to AR({$\infty$) model which can be approximated by AR(p) model. The procedure discussed in this articled is applied in general to any combination of regression model and time series model.

  • PDF

A Procedure for Computing Conduction Time Series Factors for Walls and Roofs with Large Thermal Capacity by Finite Difference Method (열용량이 큰 벽체나 지붕재의 전도시계열 계수를 유한차분법으로 구하는 과정)

  • Byun, Ki-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.27-36
    • /
    • 2018
  • The purpose of this paper is to apply the numerical solution procedure to compute conduction time series factors (CTSF) for construction materials with large thermal capacities. After modifying the procedure in Ref. [9], it is applied to find the CTSF for the wall type 19 and the roof type 18 of ASHRAE. The response periods for one hr pulse load are longer than 24hrs for these wall and roof. The CTSF generated using modified procedure agree well with the values presented in the ASHRAE handbook. The modified procedure is a general procedure that can be applied to find CTSF for materials with complex structures. For the large thermal capacity materials, it should be checked whether thermal response period of the material is over 24hr or not. With suggested solution procedure, it is easy to check the validity of the CTSF based on 24hr period.

Formulation, solution and CTL software for coupled thermomechanics systems

  • Niekamp, R.;Ibrahimbegovic, A.;Matthies, H.G.
    • Coupled systems mechanics
    • /
    • v.3 no.1
    • /
    • pp.1-25
    • /
    • 2014
  • In this work, we present the theoretical formulation, operator split solution procedure and partitioned software development for the coupled thermomechanical systems. We consider the general case with nonlinear evolution for each sub-system (either mechanical or thermal) with dedicated time integration scheme for each sub-system. We provide the condition that guarantees the stability of such an operator split solution procedure for fully nonlinear evolution of coupled thermomechanical system. We show that the proposed solution procedure can accommodate different evolution time-scale for different sub-systems, and allow for different time steps for the corresponding integration scheme. We also show that such an approach is perfectly suitable for parallel computations. Several numerical simulations are presented in order to illustrate very satisfying performance of the proposed solution procedure and confirm the theoretical speed-up of parallel computations, which follow from the adequate choice of the time step for each sub-problem. This work confirms that one can make the most appropriate selection of the time step with respect to the characteristic time-scale, carry out the separate computations for each sub-system, and then enforce the coupling to preserve the stability of the operator split computations. The software development strategy of direct linking the (existing) codes for each sub-system via Component Template Library (CTL) is shown to be perfectly suitable for the proposed approach.

An Adaptive Procedure in Finite Element Analysis of Elastodynamic Problems (적응적 방법을 이용한 동적 유한요소해석)

  • 최창근;정흥진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.04a
    • /
    • pp.1-8
    • /
    • 1994
  • An automated procedure which allows adaptation of spatial and time discretization simultaneously in finite element analysis of linear elastodynamic problems is presented. For dynamic problems having responses dominated by high frequency modes, such as those with impact, explosive, traveling and earthquake loads high gradient stress regions change their locations from time to time. And the time step size may need to vary in order to deal with whole process ranging from transient phase to steady state phase. As the sizes of elements in space vary in different regions, the procedure also permits different time stepping. In such a way, the best performance attainable by the finite element method can be achieved. In this study, we estimate both of the kinetic energy error and stran energy error induced by spatial and time discretization in a consistent manner. Numerical examples are used to demonstrate the performance of the procedure.

  • PDF

A simple computational procedure to obtain the queue-length distribution of the discrete-time GI/G/1 queue

  • Kim, Nam-Ki
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.1129-1132
    • /
    • 2005
  • Based on a discrete-time version of the distributional Little's law, we present a simple computational procedure to obtain the queue-length distribution of the discrete-time GI/G/1 queue from its waiting-time distribution that is available by various existing methods. We also discuss our numerical experience and address a couple of remarks on possible extensions of the procedure.

  • PDF

Influence of UV Irradiation Procedures on the Concentration of Vitamin $D_{3}$ and 25-Hydroxyvitamin $D_{3}$ in the Liver and Skeleton of Broiler Chicks (자외선 조사방법이 육계 병아리의 간장과 골격중 Vitamin $D_{3}$ 및 25-Hydroxyvitamin $D_{3}$ 농도에 미치는 영향)

  • ;;M.F.Holick
    • Korean Journal of Poultry Science
    • /
    • v.21 no.3
    • /
    • pp.157-168
    • /
    • 1994
  • This study was carried out to elucidate the time course variation of vitamin $D_{3}$ (V$D_{3}$) and 25-hydroxyvitamin $D_{3}$ [25(OH)$D_{3}$] contents in the liver and skeleton of 3-wk old broiler chicks when treated with different UV irradiation procedure. Day-old Hubbard chicks were fed vitamin D deficient diet for 3 wk and exposed to medium wave ultraviolet(UVB) light with different irradiation procedures. Procedure I was 30 min continuous irradiation(O.204 mJ /$cm^{2}$) and Procedure II was three seperate 10 min irradiation with 12 h intervals, and Procedure III was three seperate 10 min irradiation with 24 h intervals. The liver and skeleton samples were collected at 10 different times between 0000~2400 h after the last irradiation. The V$D_{3}$ and 25(OH)$D_{3}$ fractions wereseparated by Sep-Pak silica cartridge and the concentrations were determined by normal phase HPLC. The mean content of V$D_{3}$ in the liver of the birds treated by Procedure II was 6.68 ng /g, which was higher than 5.60 and 5.30 ng /g from Procedure I and Ill, respectively(P<.O5). With regard to the effect of elapsed time after UVB irradiation on the V$D_{3}$ concentration of the liver, 96 h treatment showed the highest value(13.08 ng/g)(P<.05). There was a significant(P$D_{3}$ were significantly(P$D_{3}$ in the skeleton of tibia and femur, there were no significant differences among Procedure I, II and III, but significant differences were found among those from various elapsed time after irradiation, The highest value was shown at 96 h(O.99 ng /g) treatment, and interaction between irradiation procedure and elapsed time was not significant. With regard to the mean content of 25(OH)$D_{3}$ in bone, the Procedure II(18.79 ng /g) and III(17.73 ng /g) showed higher values than Procedure I did (P<.05), and the 12 h elapsed time showed the highest value(31.17 ng /g) among 10 treatments (P<.05), however, there was no significant interaction between exposing procedure and elapsed time. In conclusion, the Procedure II would he more desirable than Procedure I or III to produce more V$D_{3}$ and 25(OH)$D_{3}$ in the liver and skeleton of birds by exposing to the UVB light. Also, it was verified that 25(OH)$D_{3}$ increases more quickly than V$D_{3}$ in both tissues tested and is utilized more quickly to recover from the rickets of chicks.

  • PDF

A Comparison Study of the Surgical Outcome According to the Surgical Technique (설소대단축증의 수술적 방법에 따른 비교)

  • 홍원표;서용석;송미현;양해동;김성수
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.1
    • /
    • pp.10-15
    • /
    • 2003
  • Background and Objectives : Ankyloglossia, commonly known as tongue-tie, is the result of a short, fibrous lingual frenulum or highly attached geioglossus muscle. This condition may cause sucking and swallowing problems, articulation disorders, interference with the tongue's cleansing action, increased the potential for caries, and inability to lick the lips, play a wind instrument, and 'french kiss' Treatment is surgical procedure. In the most cases, horizontal sectioning and mucosal suture(the conventional procedure) is preferred, but in some cases, the Z-plastic procedure is effective. This study is aimed to compare the result of the two procedures. Materials and Methods : Twenty tongue-tie patients underwent operation. Ten patients were treated with the Z-plastic procedure and ten patients were treated with the conventional method randomly. We checked preoperative mobile tongue length, postoperative mobile tongue length, operation time and postoperative wound states. Results : Among the 20 cases of tongue-tie, 2 cases are excepted due to pre-operative state, thus we compared 18 cases of tongue-tie patients. There is no statistically significant difference between the two procedures except in operation time. The Z-plastic procedure apparently needs a little more operating time. Conclusion : Patients treated with the Z-plastic procedures appeared to have better outcomes, but the data shows no statistical significance except in operating time. Consequently, the Z-plastic procedure is indicated in a limited amount of cases.

  • PDF

Simulation Procedure for Estimating the Reliability of a System with Repairable Units+

  • S. Y. Baek;T.J. Lim;J. S. Hong;C. H. Lie;Park, Chang K.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.691-698
    • /
    • 1996
  • This paper propose a procedure to estimate the system lifetime distribution using simulation method in a parametric framework and also develop the criterion for terminating the simulation. We assume that a system is composed of many components whose lifetime and repair time distributions are general, and repair of each component is imperfect or not. General simulation algorithms can not be adopted for this case, due to the dependency of successive operating times and the discontinuity in base line intensity function of failure process. Then we propose algorithms for generating failure times subject to imperfect repair. We develop the event time tracking logic for identifying the system failure time, and also develop the criterion for terminating the simulation. Our procedure is composed of two phases. The first phase of the procedure is to generate the system failure times from the inputs. The second phase is to estimate the lifetime distribution of the system. The best model is selected by a fully automated procedure among well-known parametric families, and the required parameters are estimated. We give examples to show the accuracy of our procedure and the effect of repair effect of components to system MTTF(Mean Time To Failure).

  • PDF

Optimal Life Testing Procedure for a System with Exponentially Distributed Failure Times

  • Yun, Sang-Un
    • Journal of the Korean Statistical Society
    • /
    • v.11 no.2
    • /
    • pp.77-87
    • /
    • 1982
  • The choice if constants that define a life testing procedure is considered in terms of the test termination time (censoring time) and the number of items to be tested subject to a given range of variance of the expected life time, where the failure time of life testing is exponentially distributed.

  • PDF