• Title/Summary/Keyword: Probe measurements

Search Result 399, Processing Time 0.022 seconds

Experimental Study on Flows within a Shrouded Centrifugal Impeller Passage -at the Shockless Condition- (밀폐형 원심회전차의 내부유동장에 관한 실험적 연구-무충돌 유입 조건에서-)

  • Kim, Seong-Won;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3262-3271
    • /
    • 1996
  • Flow patterns were measured in a shrouded centrifugal impeller. The flow rate in measurements was fixed at the value corresponding to a nearly zero incidence at the blade inlet. By using a single slanted hot-wire probe and a Kiel probe mounted on the impeller hub disk, the 3-D relative velocities and the rotary stagnation pressures were measured in seven circumferential planes from the inlet to the outlet of impeller rotating at 700 rpm, and the static pressure distribution along flow passage and the slip factor at impeller outlet were calculated from the measured values. From these measured data, the primary and secondary flows, the wake production and the static pressure rise in the impeller passage were investigated. Furthermore, the secondary flow patterns and the wake's location in this impeller passage were compared with those of the unshrouded impeller.

Measurements of the Burning Velocities of Flamelets in a Turbulent Premixed Flame

  • Furukawa, Junichi;Noguchi, Yoshiki;Hirano, Toshisuke;Williams, Forman A.
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.62-68
    • /
    • 2002
  • To investigate statistics of flamelet in a turbulent premixed flame and to obtain components of their burning velocities in a vertical plane above a pipe-flow burner, the local motion of flamelets with respect to gas are measured by specially arranged diagnostics, composed of an electrostatic probe with four identical sensors and a two-color four-beam LDV system. With this technique, the three-dimensional local flame- front-velocity vector is measured by the electrostatic probe for the first time, and simultaneously the axial and radial components of the local gas-velocity vector in a vertical plane above the vertically oriented burner are measured by the LDV system. Two components of burning velocities of planar flamelets can be obtained from these results and are found to be distributed over different directions and to range in magnitude from nearly zero to a few times the planar, un strained adiabatic laminar burning velocity measured in the unburnt gas. It may be concluded from these results that turbulence exerts measurable influences on flamelets and causes at least some of them to exhibit increased burning velocity.

  • PDF

The Role of Synovial Fluid in the Micro-scale Frictional Response of Bovine Articular Cartilage from Atomic Force Microscopy (원자힘 현미경을 이용한 활액이 소 연골의 미세 마찰특성에 작용하는 역할)

  • Park, Seong-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.11
    • /
    • pp.119-125
    • /
    • 2008
  • The objective of this study was to compare micro-scale friction coefficients with and without synovial fluid, and micro-scale measurements were performed using atomic force microscopy (AFM) with a $5{\mu}m$ spherical probe. Four cylindrical cartilage specimens were harvested from two fresh bovine humeral heads (4-6 months old). $Average{\pm}standard$ deviation values of the micro-scale AFM frictional coefficients calculated from the liner fit of friction versus normal force was $0.177{\pm}0.012$ and $0.130{\pm}0.010$ with and without synovial fluid coating on AFM probe respectively, showing its reduction by ${\sim}27%$ with synovial fluid. To the best of our knowledge, this experimental study investigates the first such comparisons of frictional response of articular cartilage with and without synovial fluid coating on AFM probe, and provides significant insights into the role of synovial fluid in the articular cartilage friction and lubrication independently of the confounding effect of fluid pressurization in the articular cartilage.

Measurement using Low-temperature Scanning Hall Probe Microscopy and Analysis of Local Current Distribution using Inversion Problem Technique (저온 주사 홀소자 현미경과 역변환 방법을 이용한 국소적 전류 분포 분석)

  • Cho, B.R.;Park, S.K.;Park, H.Y.;Ri, H.C.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.34-39
    • /
    • 2011
  • We have performed measurements of the local magnetic field distribution of YBCO coated conductors using Low-temperature Scanning Hall Probe Microscopy (LT-SHPM). Distribution of stray magnetic field of various types of YBCO coated conductors in the superconducting state was measured in presence of external magnetic fields. We analyzed one dimensional and two dimensional local current distribution using inversion technique from the magnetic field distribution.

pH Measurements with a Microcantilever Array-Based Biosensor System

  • Hur, Shin;Jung, Young-Do
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.186-191
    • /
    • 2012
  • In this paper, we present a pH measurement method that uses a microcantilever-array-based biosensor system. It is composed of microcantilever array, liquid cell, micro syringe pump, laser diode array, position sensitive detector, data acquisition device, and data processing software. Four microcantilevers are functionalized with pH-sensitive MHA(mercaptohexadecanoic acid) as a probe, while three microcantilevers are functionalized with HDT(hexadecane thiol) as reference. We prepare PBS(phosphate buffered saline) solutions of different pH and inject them into the liquid cell with a predefined volumetric speed at regular time intervals. The functionalized mircocantilevers in the liquid cell deflect as a self-assembled monolayer on the microcantilever binds with probe molecules in the solution. The difference in deflection between the MHA-covered probe microcantilever and the HDT-covered reference microcantilever was used to compensate for thermal drift. The deflection difference clearly increases with increasing pH in the solution. It was shown that when the pH values of the PBS solutions are high, there were large variations in the deflection of microcantilevers, whereas there were small variations for low pH value. The experimental results show that the microcantilever array functionalized with MHA and HDT can detect pH value with good repeatability.

4 Electrical Resistivity Probe for Investigating soft offshore soils (해안연약 지반 조사를 위한 4전극 전기비저항 프로브)

  • Kim, Joon-Han;Yoon, Hyung-Koo;Bae, Myeong-Ho;Jung, Soon-Hyuck;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.464-475
    • /
    • 2009
  • Electrical resistivity can be used for porosity estimation. In order to improve previously developed ERCP(Electrical Resistivity Cone Probe), 4ERP(4 Electrical Resistivity Probe), which has Wenner array at the tip of probes, has been developed. In properties of current flow Wenner array measures electrical properties of undisturbed area during penetration and relatively correct measurements are guaranteed without polarization. Furthermore, Wenner array equation can estimate electrical resistivity without extra calibration. 4ERP is developed into 2 types, penetration and fixation. Penetration type has wedge-shaped tip. Considering disturbance minimization, fixed type has plane tip. Fixed type 4ERP in consolidation cell measure electrical resistivity increment along porosity decrease, and penetration type 4ERP measured resistivity profile along the depth in chamber. Applying Archie's law, porosity profile was estimated with electrical resistivity. The tests result suggests that 4ERP can be new site investigation equipment with little disturbance.

  • PDF

Soft x-ray magneto-optical effect as a nanometer scale probe of heteromagnetic structures widely used in spintronics devices

  • Kim, Sang-Koog
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2003.05a
    • /
    • pp.7-7
    • /
    • 2003
  • Heteromagnetic nanostructures, which consist of two or more different layers such as nonmagnet, insulator, ferromagnet, antiferromagnet, and superconductor, have been widely used in current and likely future spintronics devices. Their many intriguing magnetic properties are originated from a variety of magnetic interactions at relevant length scales at or near interfaces and between different constituent layers as well as laterally different regions in chemical and magnetic heterogeneity. The fundamental properties can thus differ along depth and laterally in the film plane, depending on their relevant coupling length scales. The entire properties may be characterized by interface properties and/or the depth-varying properties of the individual constituent layers, and lateral inhomogeneity as well. It is a challenge to investigate both depth-varying properties and lateral heterogeneity in such heteromagnetic nanostructures. In this talk, soft x-ray magneto-optical effect as a nanometer scale probe of a variety of heteromagnetic structures is presented and its related noble techniques are introduced. For instances, magnetization vector imaging to investigate vector spin configurations in the film plane is presented, as well as the Kerr rotation, ellipticity, and intensity measurements as a depth sensitive probe on the atomic scales.

  • PDF

Changes in Hydrophobic Surface of Collagen by Chondroitin Sulfate : Fluorescence Intensity Measurements with Bis-ANS as the Probe

  • Kim, Sung-Koo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.3
    • /
    • pp.446-453
    • /
    • 1995
  • The improtant components of extracellular matrix(ECM) are collagen and chondroitin sulfate. The hydrophobic surface of collagen is one of the determining factors of diameter of collagen fiber and also is closely related to the aging phenomena. The controlling mechanism of the diameter of collagen fiber influenced by the interaction with chondroitin sulfate was evaluated using bis-ANS as a hydrophobic probe. Hydrophobic surface area of collagen molecule shielded by chondroitin sulfate was evaluated. Relative fluorescence intensity of collagen in thepresence of chondroitin sulfate was measured using bis-ANS as a hydrophobic probe. The fluorescence intensity decreased with the increase in chondroitin sulfate up to 3.8 chondroitin sulfate/collagen(mole/mole). Further increase in the ratio of chondroitin sulfate to collagen did not change the fluorescence intensity. Similar changes in the relative fluorescence intensity were observed for both rat tail and lathyrific rat skin collagen. The fluorescence intensity indicated by the binding between bis-ANS and hydrophobic sites of collagen was pH dependent, and the shielding effect of collagen-chondroitin sulfate interaction could not be detected at pH above 6.0. This is probably due to the charge repulsions caused by negative charged collagen molecules at higher pH.

  • PDF

Ground Subsidence Estimation in a Coastal Reclaimed Land Using JERS-1 L-band SAR Interferometry (JERS-1 L-band SAR Interferometry 를 이용한 연안매립지 지반침하 관측)

  • 김상완;이창욱;원중선
    • Economic and Environmental Geology
    • /
    • v.35 no.5
    • /
    • pp.465-478
    • /
    • 2002
  • We measured subsidences occurred in a coastal reclaimed land, Noksan industrial complex, from May 2, 1996 to February 21, 1998, using 5 interferograms of JERS-1 L-band SAR. SAR with a spatial resolution of about 16 m can detect the two-dimensional distribution of subsidence that is difficult to be estimated from in situ measurements. Accuracy of the subsidences estimated by 2-pass DInSAR was evaluated using the measurements of Magnetic Probe Extensometer (accuracy of :${\pm}$1 mm) installed at 42 stations. DInSAR measurements were well correlated with the field measurements showing an average correlation coefficient of 0.77. The correlation coefficient was further improved to be 0.87 (with RMSE of 1.44 cm) when only highly coherenced (>0.5) pixels were used. The slope of regression line was 1.04, very close to the unit value. In short, DInSAR measurements have a good linear relation with field measurements so that we can effectively detect a subsidence in the coastal reclaimed area especially using pixels of high coherence (>0.5). The maximum accumulated subsidence was about 60 cm in the study area, while the subsidence in the northern and south western areas were less than 20 cm. The resuts show that DInSAR is extremely useful for geotechnical applications as well as observation of natural deformation.

Concentration measurements of the premixed mixture by using a hot wire concentration probe (열선농도 프로우브를 이용한 여혼합기의 순간농도 측정에 관하여)

  • 박경석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.1
    • /
    • pp.12-17
    • /
    • 1985
  • 주위기체와 다른 기체를 간헐적으로 또는 단발로 분사한 경우, 분류내의 분사체의 농도는 시간에 따라 급격히 변화한다. 수ms인 전자식기체 채취밸브를 이용해서 기체를 채취하고, 가스마토그 라프 등에 의해 가스분석을 행하는 방법이 있고 주로 피스톤식 내연기관의 연소실내 농도의 측 정에 이용되고 있다. 이 방법은 밸브 열립시간을 단축시켜도 약 1ms가 한도이고 시간분해능력도 1ms정도가 최단시간이다. 또 동일한 장소에서 농도의 시간경과를 얻는 데에는 각각의 시간에 대해서 기체의 채취와 분석을 행하지 않으면 안되어 실제시간의 농도측정이 불가능하다는 결점이 있다. 최근 레이저 응용기술의 진보에 의해 라만산란, 레리산란, CARS법 등의 농도순간측정이 가능해지고 있고, 점차 현실화되어가고 있다. 이들의 방법은 국소의 순간농도뿐만 아니라 온도의 동시측정도 가능하게 하는 특징을 갖고있다. 그러나 레이저에 의한 측정장치는 현시정에서는 아직 가격이 고가이고 광학계의 설치 등, 실험상의 조작이 복잡한 것 등의 결점을 갖고 있다. 본 고에서는 최근 진전이 현저하고 실용화에 대한 확신을 갖고 있는 열선농도Probe에 의한 순간농 도의 측정방법을 소개하고자 한다.

  • PDF