• 제목/요약/키워드: Probe location

검색결과 123건 처리시간 0.022초

GPS 휴대폰을 이용한 차량경로용 도로망 데이터베이스 수정 방안 (A Road Database Update Method for Vehicle Routing Using GPS Cellular Phone)

  • 장영관
    • 대한안전경영과학회지
    • /
    • 제9권5호
    • /
    • pp.97-101
    • /
    • 2007
  • As the use of vehicle route application and LBS(location based service) are fast grew, the importance of maintaining road network data is also increased. To maintain road data accuracy, we can collect road data by driving real roads with probe vehicle, or using digital image processing for the extraction of roads from aerial imagery. After compare the new road data to current database, we can update the road database, but that job is mostly time and money consuming or can be inaccurate. In this paper, an updating method of using GPS(global positioning system) enabled cell phone is proposed. By using GPS phone, we can update road database easily and sufficiently accurately.

다양한 측정방법을 적용한 대지의 전기적 구조해석 (Electrical Structure Analysis of Ground using Various Methods for Resistivity Measurement)

  • 조성철;이태형;엄주홍;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1492-1493
    • /
    • 2006
  • Wenner 4-probe arrangement is used most widely by the method to measure soil resistivity and the measured data with the Wenner method are apparent resistivities of the soil. Therefore, the soil structure can be analyzed easily from the measured apparent resistivity, but the real soil resistivity is difficult to know correctly at a particular depth or at a specific location on earth surface. This paper introduces a method that can be used to decide the suitable burial depth and the electrode scale of a grounding rod effectively using soil structure analysis equipment based on the dipole-dipole method.

  • PDF

2중방진 시스템의 실험적 거동해석 (Experimental Behavior Analysis of Double Isolated Anti-Vibration System)

  • 이홍기;이신언
    • 소음진동
    • /
    • 제2권4호
    • /
    • pp.281-292
    • /
    • 1992
  • Two types of vibration problems are encountered in industrial field: active isolation and passive isolation. In a passive type of vibration isolation, a foundation of a delicated machinery such as TEM, SEM, inspection- probe test, photolithograph, etc. is designed to have a vibration amplitude lower than an acceptable limit. In an active type, the isolation is focused on the vibration reduction caused by the machine itself(pump, motor, press, compressor, etc.). The foundation for such a machine should be so designed as to reduce the transmitted vibration below the permissible level prescribed. At any case, a transmissibility and stability must to be considered. Since an active isolation type is aimed for a vibration source, it is useful to isolate the transmitted vibrations energy from a major vibration source at the specific location. In this paper, a designed methodology of double anti-vibration system has been examined in order to have low transmissibility and reliable stability. Also experiment of scale model behavior has been conducted. Finally, the experiment output of the transfer function is compared to the analytical data.

  • PDF

가상 용접부내의 결함으로부터 반사된 초음파의 지향성 해석 (Directivity Analysis of Ultrasonic Wave Reflected from the Artificial Defect in Simulated Butt Welded Joint)

  • 남영현
    • 비파괴검사학회지
    • /
    • 제15권2호
    • /
    • pp.378-385
    • /
    • 1995
  • 초음파검사는 초음파 펄스가 한 방향으로 진행한다고 하는 지향성을 이용하고 있다. 초음파의 지향성은 전파 방향과 음압 분포의 관계를 나타내고 있으며 탐촉자의 배치, 탐상 감도 및 주사 간격, 결함의 위치 및 특성의 결정에 밀접한 관계가 있다. 본 논문은 초음파가시화법을 이용하여 pyrex glass로 만든 가상 맞대기 용접부내의 용접 금속부에 위치한 인공 결함으로부터 산란한 반사 횡파의 지향성을 측정하였다. 2 MHz와 4 MHz의 사각탐촉자가 인공 결함에서의 반사파의 지향성 조사에 사용되었다. 인공 결함으로부터 반사된 횡파의 지향성은 사각탐촉자의 위치 및 가상 용접부의 형상에 따라 달랐으며 2 MHz와 4 MHz의 사각 탐촉자에 따라 반사파의 지향성은 큰 차이를 나타내고 있었다. 또한 가상 용접부의 높이가 커짐에 따라 반사각과 입사각은 비슷하게 되었다.

  • PDF

A Study on the Profile Change Measurement of Steam Generator Tubes with Tube Expansion Methods

  • Kim, Young-Kyu;Song, Myung-Ho;Choi, Myung-Sik
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.543-551
    • /
    • 2011
  • Steam generator tubes for nuclear power plants contain the local shape transitions on their inner or outer surface such as dent, bulge, over-expansion, eccentricity, deflection, and so on by the application of physical force during the tube manufacturing and steam generator assembling and by the sludge (that is, corrosion products) produced during the plant operation. The structural integrity of tubes will be degraded by generating the corrosive crack at that location. The profilometry using the traditional bobbin probes which are currently applied for measuring the profile change of tubes gives us basic information such as axial locations and average magnitudes of deformations. However, the three-dimensional quantitative evaluation on circumferential locations, distributional angle, and size of deformations will have to be conducted to understand the effects of residual stresses increased by local deformations on corrosive cracking of tubes. Steam generator tubes of Korean standard nuclear power plants expanded within their tube-sheets by the explosive expansion method and suffered from corrosive cracks in the early stage of power operation. Thus, local deformations of steam generator tubes at the top of tube-sheet were measured with an advanced rotating probe and a laser profiling system for the two cases where the tubes expanded by the explosive expansion method and hydraulic expansion. Also, the trends of eccentricity, deflection, and over-expansion of tubes were evaluated. The advanced eddy current profilometry was confirmed to provide accurate information of local deformations compared with laser profilometry.

Escherichia coli의 시티딘/디옥시시틴딘 디아미나제를 코드하는 cdd 유전자의 클로닝 (Molecular Cloning of Escherichia coli cdd Gene Encoding Cytidine/Deoxycytidine Deaminase.)

  • 권택규;김태호;황선갑;김종국;송방호;홍순덕
    • 한국미생물·생명공학회지
    • /
    • 제18권6호
    • /
    • pp.640-646
    • /
    • 1990
  • E.coli의 cytidine deaminase(cytidine/2'-deoxy-cytidine aminohydrolas` EC 3.5.4.5)를 코딩하는 cdd 유전자를 E.coli cdd- pyr- 결손 변이주를 cloning host로 하여 southern blotting과 colony hybridization을 통하여 클로닝하였다. cdd 유전자가 단편인, cdd 유전자의 transcription initiation 부위의 23개 nucleotide를 합성한 후 probe로 사용하여 Southern hybridization에 의해 회수된 cdd 유전자를 함유한 단편을 얻었으며, 이를 pBR322에 삽입한 후 형질전환하여 colony hybridization한 결과 cdd+ cell을 얻었다. 삽입된 DNA 단편의 size는 27kb이었으며 이를 결실 및 subcloning을 연속 수행한 결과 2.1kb의 SalI/ DraI fragment(pTK605)에 cdd 유전자가 location 되어 있음을 알게 되었다. Mini cell 실험결과 합성된 cytidine deaminase의 활성이 pBR322에서 증폭시킴으로서 37배 정도 배가되었으며, pBR322에 비해 pUC vector계에서 다시 활성이 7배 정도 증가됨을 알 수 있었다.

  • PDF

김치 유래 젖산균의 Cell-envelope Proteinase 존재 확인 (Identification of the Cell-envelope Proteinase of Lactic Acid Bacteria Isolated from Kimchi.)

  • 이유진;최재연;이형주;장해춘;김정환;정대균;김영석;김소미;이종훈
    • 한국미생물·생명공학회지
    • /
    • 제30권2호
    • /
    • pp.116-122
    • /
    • 2002
  • 김치로부터 분리된 젖산균들의 16S rDNA 부분 염기서열 결정 결과, 6균주 중 2균주는 Leuconostoc mesenteroides로, 나머지 균주는 Lactobacillus속으로 재동정되었다. 이들 김치유래 젖산균들은 유제품 유래 젖산균과 마찬가지로 cell-envelope proteinase (CEP)로 추정되는 세포외 proteinase 활성을 보유하고 있는 것으로 나타났고, 젖산균의 CEP 특이적 primer를 제작하여 PCR을 수행한 결과, Leu. mesenteroides로부터는 예상 크기의 PCR 산물이 증폭되지 않았지만 Lactobacillus속 균주들로부터는 예상되는 1.2 kb 의 DNA 단편이 증폭되었다. Lactobacillus pentosus KFR1821의 genomic DNA로부터 증폭된 PCR 산물의 추정 아미노산서열은 Lactococcus lactis subsp. cremoris의 PrtP와 95%, Labtobacillus paracasei subsp. paracasei이 PrtP와 92%의 높은 상동성을 보였다. 증폭된 PCR 산물을 probe로 하여 Southern hybridization을 수행한 결과, Lb. pentosus KFR1821의 CEP 유전자는 chromosomal DNA에 암호화 되어있는 것으로 확인되었다.

체내 소형 이물질 진단에서 초음파 검사의 유용성 (Usefulness of Ultrasonography in Diagnosis of Small Foreign Bodies)

  • 김철진;정양국;박태용
    • 대한정형외과 초음파학회지
    • /
    • 제5권2호
    • /
    • pp.75-80
    • /
    • 2012
  • 목적: 체내 소형 이물질이 있는 것으로 의심되나 이학적 검사 및 단순 방사선 검사로 확인이 되지 않을 때, 이물질의 유무, 위치, 크기와 성상을 확인하고 제거하는데 있어 초음파 검사의 유용성을 알아보고자 하였다. 대상 및 방법: 2007년 3월부터 2012년 2월까지 수부 및 족부의 소형 이물질을 수술적으로 제거 받은 환자 중 수술 전 초음파 검사를 시행한 9명을 대상으로 하였다. 수상일로부터 수술일까지 이환 기간은 평균 32개월이었으며 부위는 수지 5예, 수장부 2예, 수배부 1예 및 족저부 1예였다. 2예에서 수술 전 단순 방사선 검사상 이물질을 확인할 수 있었으나 7예에서는 확인되지 않았으며 초음파 검사로 진단할 수 있었다. 고해상 선형 탐색자를 이용하여 초음파 검사를 시행하였으며 이물질의 유무, 위치 및 크기에 대해서 수술 소견과 비교하였다. 결과: 수술 전 초음파 검사에서 확인된 위치와 수술 소견이 잘 부합하였다. 이물질은 유리조각이 4예, 가시가 4예, 연필심이 1예였으며 평균 크기는 3.9 mm (2~7 mm) 였다. 결론: 체내에 소형 이물질이 잔류하는 것으로 의심되는 환자에서 초음파 검사는 진단 및 치료에 있어 유용한 검사로 사료된다.

  • PDF

유방암환자 전초림프절의 유방 림프신티그라피에 관한 연구 (The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in breast cancer)

  • 김화곤;김창수;김명준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권2호
    • /
    • pp.75-81
    • /
    • 2006
  • 과거 유방암 환자에서 대부분을 수술로 불필요한 액와림프절 절개술을 하였지만, 그 결과로 부작용이 발생하였다. 본 논문에서는 유방암 환자에게 $^{99m}Tc-Tincolloid$를 이용하여 수술 전 유방림프절 검사를 먼저 시행한 뒤 처음 나오는 전초림프절을 영상화한 뒤 전초림프절의 전이 여부에 따라 수술범위를 달리 결정함으로써 환자의 수술 시간 및 수술 후의 부작용 최소화가 목적이다. 논문의 실험 결과는 실험대상 20명의 환자 중 15명에서는 액와림프절 절개술을 시행하지 않아도 되기에 수술로 인한 부작용을 줄일 수 있다. 그러나 아직까지 표준방법, 즉 방사성의약품 주사부위, 방사선량, 주사량, 마사지여부, 림프신티그라피 시행여부 등이 결정되지 않았으므로, 환자에 대한 고통경감과 부작용을 최소화 하고 수술부위를 최소화하기 위해서는 유방암 림프절검사법이 유용할 것이라 생각된다. 실험의 대상이 되는 환자는 초음파, 유방촬영술, 생검에서 유방암 진단을 받고 수술할 예정인 환자 20명으로, 환자의 연령 범위는 $31{\sim}71$세로 평균 연령은 45.4세이며, 임상 병기 I이 9명, 임상병기 II가 11명이다. 실험 장비로는 전초림프절을 묘출시켜주는 추적자로 $^{99m}Tc-Tincolloid(Amesham)$과 전초림프절의 위치를 찾는 장비로 Micro Probe : Neoprobe 2000(이하 감마 프로브), 영상 묘출 장비로 MS-II Gamma Camera : SIEMENS (이하 MS-II Gamma Camera)가 사용되었다. 실험 방법은 3가지 방법을 사용하며, 그 중 하나를 선택해 전초림프절 검사 및 수술실에서 감마프로브를 이용하여 생검을 실시한 결과의 20명 모두에서 전초림프절을 영상화 했다. 그리고 감마프로브로 전초림프절을 찾아 조직 생검 결과 20명 중에서 전초림프절의 전이가 발견된 환자는 5명이다. 본 실험에서 전이가 발견된 환자 5명을 다시 액와림프절을 생검한 결과의 3명에서 액와림프절 전이가 발견되었다.

  • PDF

유방암 검출을 위한 생계 어드미턴스 스캐너의 개발 (Development of Trans-Admittance Scanner (TAS) for Breast Cancer Detection)

  • 이정환;오동인;이재상;우응제;서진근;권오인
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권5호
    • /
    • pp.335-342
    • /
    • 2004
  • 암세포가 정상세포에 비해 전기적 도전율이 세배에서 열배까지 높다는 점을 이용하여 본 논문에서는 유방암 검출을 위한 생체 어드미턴스 스캐너를 개발하고, 시스템의 성능검사를 수행하여 유방암 검출의 가능성을 제시하였다. 전압인가전극을 이용하여 정현파의 정전압을 인가하고 유방의 표면에 부착된 평면배열 접지전극을 통하여 배출되는 전류를 측정한다. 측정된 전류값과 인가한 전압사이의 전달 어드미턴스로부터 측정 부위의 도전율을 표현할 수 있으며, 전달 어드미턴스의 실수부와 허수부의 크기로부터 유방암의 유무와 크기, 위치를 판별하는 데이터를 획득한다. 개발한 생체 어드미턴스 스캐너는 주제어부, 인가전압 발생부, 유기전류 측정부, 전압인가전극 및 평면배열 접지전극과 컴퓨터로 구성된다. 개발한 디지털 인가전방 발생기의 진폭 안정도는 0.2445%의 오차를 가지며, 총 고조파 왜곡은 0.03% 이다. 유기전류 측정부는 실수부의 경우 68dB, 허수부의 경우 54dB이상의 SNR블 가지며, 1nA정도의 작은 전류도 측정이 가능하도록 제작되었다. 저항 펜텀을 이용하여 실험한 결과 측정된 핀달 어드미턴스는 Pspice 시뮬레이션 결과와 비교할 때 93% 이상의 정확도를 나타내었다. 이러한 측정의 정확도를 갖는 생체 어드미턴스 스캐너를 가지고 저항 팬텀 및 전해질용액 펜텀을 이용하여 실험한 결과 도전율이 다른 물체를 식별할 수 있는 전달 어드미턴스 분포 영상을 획득할 수 있음을 확인하였다. 향후 시스템의 성능을 향상시키고, 여러 가지 다른 핀범을 제작하여 이를 정확히 찾아내는지를 실험할 예정이며, 도전율이 다른 물체의 크기, 위치 및 깊이를 찾는 알고리즘을 시스템에 적용하여 알고리즘을 실험적으로 검증하고 유방암의 조기 검진을 위해 활용이 가능한 시스템을 개발하는 연구를 수행할 예정이다.