• Title/Summary/Keyword: Probe head

검색결과 84건 처리시간 0.031초

1단 축류터빈 로터의 후류에서 비정상 전압력 측정에 관한 연구 (Measurement of Unsteady Total Pressure downstream of an 1-Stage Axial Turbine)

  • 강정식;차봉준;양수석;이대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.318-323
    • /
    • 2005
  • To evaluate the accurate performance of turbomachinery, it is important to measure the unsteady flow phenomena downstream of the rotor blade. This paper presents the development of the fast-response total pressure probe for the measurement of the total pressure field at the exit of rotor and the result of measurement in a 1-stage axial turbine. The fast-response total pressure probe was fabricated by installing a fast-response pressure sensor near the head of a Kiel probe. And it measured the phase-lock averaged total pressure downstream of an 1-stage axial turbine. The developed probe successfully measured the accurate total pressure distribution at rotor exit and made possible to evaluate the loss distribution and the accurate performance of turbomachinery.

  • PDF

Noninvasive blood glucose monitoring system based on NIR spectroscopy with a contact pressure control device

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.67.3-68
    • /
    • 2003
  • The purpose of this study is to improve repeatability of a non-invasive blood glucose measurement. The portable NIR system that was newly integrated by our lab includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector, which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of finger tip were recorded by using a fiber optic probe. The probe was fixed in the system and subjects put their finger on the probe head. (omitted)

  • PDF

Development of On -Line Work Roll Surface Monitoring System At Hot Strip Mill

  • Moon, Bae-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.53.4-53
    • /
    • 2001
  • This paper described about the system which can be inspect work roll surface for deciding a milling schedule and roll changing at hot strip mill in POSCO. Developed system consists of CCD camera, Xenon lamp with fiber bundle and mechanical control part. The water probe build up water pole between head of probe and roll surface to acquisite a good image from a work roll surface under the bad environment with steam, cooling water and high temperature. This system is possible to monitor a work roll surface of about 12${\times}$9mm. We have shown the validation of the developed system which can monitor the evolution of degradation on work roll surface.

  • PDF

I/Q 변조 풀이 방식의 헤테로다인 간섭계를 이용한 미소 전기장 및 복굴절 측정 (A new, hybrid, heterodyne, fiber-optic electric field sensor scheme and its applications)

  • 윤신영;조규만;이용산
    • 한국광학회지
    • /
    • 제8권2호
    • /
    • pp.161-164
    • /
    • 1997
  • 편광유지 광섬유를 이용한 주파수가 안정화된, 두 개의 서로 수직으로 편광된 종모우드를 갖는 He-Ne레이저 빛을 LoTa $O_{3}$ 위상변조기로 구성된 센서부(sensor head)로 전달해 줌으로써 원격에서 전기장을 측정할 수 있는 hybrid, heterodyne 간섭식 센서를 구성하였다. In/quadrature-phase위상변조풀이 방식을 이용하여 전기광학 효과에 의해 서로 수직으로 편광된 두 모우드 사이에 유도된 위상차이를 측정함으로써 항상 높은 검지율을 유지할 수 있는 전기장 센서를 구성하고, 이를 이용하여 광학 물질에 유도된 복굴절도 측정을 할 수 있었다.

  • PDF

비점수차법을 이용한 초정밀변위측정법 연구 (Precision Displacement Measurement Using Astigmatism)

  • 이상헌;정광석
    • 한국정밀공학회지
    • /
    • 제25권7호
    • /
    • pp.87-94
    • /
    • 2008
  • The displacement sensor using optical pickup head is presented. The measuring principle of optical pickup head in focusing direction is adopted to measure displacement. The preliminary tests were carried out to verify the feasibility of the optical pickup head as a displacement sensor and optical pickup head showed about $8\;{\mu}m$ measuring range and 10nm resolution. The methodology to expand measuring range is proposed and proved its validity. The proposed displacement sensors are applied to AFM(Atomic Force Microscope) probe head to measure the deflection of micro-cantilever.

Experimental Analysis of Radiative Heat Interchange on Furnace Exit Plane of a Steam Boiler

  • Ahn, Kook-Young;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.239-247
    • /
    • 2001
  • Measured radiative heat fluxes on the furnace exit plane of a heavy duty power boiler of steam output 1650 T/h are discussed. A high-ash pulverized bituminous coal was used. Such measurements are necessary to improve heat fluxes inside a steam boiler furnace was manufactured. An extra small heat radiation sensor was placed in the water cooled head of the probe. The sensor had no direct contact with furnace gases and measured only the radiant energy. There was no exposure to convective heat transfer. With the radiometric probe, one can obtain a spherical indicatrix of radiation intensity as well as hemispherical radiative heat flux incident on any surface passing through a measuring point inside the furnace. Thus, the quantity of radiation energy, passing through the furnace exit plane, to the convective heating surfaces and the quantity of radiation energy going in the opposite direction were measured. A formula for relative radiative heat flux on the furnace exit plane has been proposed.

  • PDF

SI 엔진의 텀불 유동과 화염전파 (Tumble flow motion and flame propagation in a SI engine)

  • 지명석
    • 한국산업융합학회 논문집
    • /
    • 제2권2호
    • /
    • pp.155-163
    • /
    • 1999
  • In this study, single cylinder engines with different tumble ratio were made to find out in-cylinder fluid motion and flame propagation. Tumble ratio derived from the steady state flow rig test. Flame propagation speed was obtained using cylinder head gasket ionization probe and the piston ionization probe. And the combustion pressure in cylinder was measured to analyze the combustion characteristics. In case of high tumble engine, BSFC and BSHC were decreased and BSNOx was increased at part load test. Also BMEP and combustion peak pressure was increased at full load test. Tumble flow motion had an great effects on initial burning period rather than main burning period in part load test.

  • PDF

피스톤 형상이 연소와 화염전파에 미치는 영향 (The Effect of Piston Configuration on Combustion and Flame Propagation)

  • 지명석;강기영
    • 한국산업융합학회 논문집
    • /
    • 제22권5호
    • /
    • pp.511-517
    • /
    • 2019
  • Two type pistons which had different configuration were made to find out the effects on combustion and flame propagation. Flame propagation speed was obtained by use of the cylinder head gasket ionization probe. Ionization Probe voltage output and flame propagation speed were increased according to the air fuel mixture ratio increase. Exhaust direction flame propagation speed was fastest in combustion chamber and next was front direction, rear direction and intake direction cause of tumbling motion in cylinder. In case of remove the valve pocket in piston, average flame propagation speed changed slowly and spark timing was advanced. Also emission was decreased.

최소침습 방사능 유도 부갑상선 수술 (Minimally Invasive Radio-guided Parathyroid Surgery)

  • 정웅윤;장항석;이종두;박정수
    • 대한두경부종양학회지
    • /
    • 제15권2호
    • /
    • pp.194-199
    • /
    • 1999
  • Introduction: Since 1996, Dr. James Norman has successfully performed mimimally invasive radio-guided parathyroidectomy(MIRP) using intraoperative nuclear mapping with $^{99m}Tc$ sestamibi scanning and radioactivity detection probe. Objectives: We aimed to introduce this new surgical technique and evaluate it's efficacy by our own experiences. Method: From May to October 1999, five consecutive patients with primary hyperparathyroidism underwent parathyroidectomy by using modified MIRP technique. $^{99m}Tc$ sestamibi scanning was performed 1.0 or 1.5 hour before operation. After intraoperative localization of the tumor under the guidance of quantitative gamma counting with a NEVIGATOR probe, an unilateral small skin incision(3.0-4.0cm) was placed. Without a skin flap, the strap muscle was directly divided with the use of a Harmonic scalpel. After careful dissection, the parathyroid tumor was removed. Result: In all patients, a single adenoma could be easily detected and removed by this new technique. Mean incision length was 3.2cm(3.0-4.0cm) and operative time ranged from 40 to 110minute. All the patients were discharged within 2 days of surgery without any complication. Conclusion: This new operative technique could become the most minimally invasive alternative to the standard operative procedure for parathyroid adenoma.

  • PDF