• 제목/요약/키워드: Probe angle

검색결과 229건 처리시간 0.028초

열선에 사용되는 새로운 요각함수의 제안 (Proposition of a new yaw function for the use of hot wire)

  • 김정훈;유정열;조성권
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.131-138
    • /
    • 1998
  • Conventional yaw functions are compared with actual response of a hot wire to various yaw angles, and a new function is proposed, which can be applied at large yaw angles and low velocities. To compare the accuracy of the new yaw function with those of the conventional ones, measurements are made for the jet flow at the nozzle exit and at .chi./D=15 with an X hot-wire probe. In the potential core, the flow angles reduced by the present function, ideal angle method and full velocity-angle method are shown to be more accurate than those reduced by the cosine function and Hinze's formula. No matter which yaw functions are used, the profiles of mean velocity and turbulence intensity show little discrepancy at .chi./D=15. However, there is a significant difference between the probability density functions obtained by the present function, ideal angle method and full velocity-angle method and those obtained by the cosine function and Hinze's formula.

반류 계측용 5공 피토관의 캘리브레이션 방법에 관한 연구 (Study on the calibration of a five-hole Pitot-tube for the wake measurement)

  • 김우전;김도현;윤현세;문덕용;반석호
    • 대한조선학회논문집
    • /
    • 제34권2호
    • /
    • pp.11-19
    • /
    • 1997
  • 선미 반류분포를 계측하기위해 수조에서 흔히 사용하는 5공 피토관의 새로운 캘리브레이션 방법을 제안하였다. 기존의 한 각도(수평 또는 수직)만을 고려하는 1차원 캘리브레이션 방법과는 달리, 본 논문에서 제안한 2차원 차트 캘리브레이션 방법은 수평각과 수직각을 동시에 변화시켜 얻어진 2차원 차트를 이용하여 종전에 큰 각도에서 발생하던 오차를 줄임으로써 계측 정도를 크게 향상시켰다. 또한 종래의 1차원 방법에 맞추어 구성된 계측 시스템을 수정 없이 사용할 수 있도록 상관계수를 정의함으로써 사용의 편의를 도모하였다.

  • PDF

수직관에서 2상선회유동이 보이드분포와 압력강하에 미치는 영향 (The Effects of Two - Phase Swirling Flow on Void Distribution and Pressure Drop in a Vertical Tube)

  • 김인석;손병진;신현동;곽기태
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.190-201
    • /
    • 1989
  • This experimental investigation has been conducted to determine the effects of swirling angle and flow patterns on distributions of void fraction, bubble velocity and two-phase pressure drop in a vertical straight tube. Swirling angles of $0^{\circ}$ (non swirling), $30^{\circ}$, and $45^{\circ}$ were tested with air-water two components over a range of superficial air velocities. A transparent lucite tube of 38mm in internal diameter was used for the test section. The void fraction and bubble velocities were measured by means of a optical fiber probe at the upper part of the swirler in the test section. Pressure drops which seem to be closely related with flow patterns and swirling angle were measured by a differential pressure transducer. It is shown that the probability density functions of pressure drop demonstrate peculiar features for both swirling angles and flow patterns, whereas the distributions of void fraction and bubble velocities are parabolic and flat shape in the vicinity of tube center, respectively except bubbly flow in any swirling angle cases, and the void fraction increases with increasing swirling angle around the center of tube.

  • PDF

열선유속계를 이용한 좁은 유로 내 유속 측정법 (Velocity Measurement Technique in a Narrow Passage by Hot-wire Anemometer)

  • 김원갑;한성호;최영돈
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.191-201
    • /
    • 2007
  • It was noted by the several researchers that the voltage outputs in response to a single yawed hot-wire sensor in a flow perpendicular to the axis deviate from the theoretical voltage output by King's law and Jorgensen's relation. This study noticed that the calibration coefficients of original Grande's method are not constant and fairly sensitive to the radial angle (${\alpha}_{R}$). For more accuracy, this study interpolated the parameters of the Grande relation as a function of radial angle and compared velocity components with ones by Jorgensen and original Grande relation in the calibration jet flow. Finally, as a test case, 3-dimensional turbulent flows of the inlet plane of 180 degree bend are measured and compared the velocity components by above three methods and showed the characteristics of the flows.

1차원 배열 탐촉자의 방사빔추적기법을 이용한 정적 3차원 초음파진단영상 구성 (Construction of Static 3D Ultrasonography Image by Radiation Beam Tracking Method from 1D Array Probe)

  • 김용태;도일;안봉영;김광연
    • 비파괴검사학회지
    • /
    • 제35권2호
    • /
    • pp.128-133
    • /
    • 2015
  • 원격진료를 요하는 응급현장에서 사용을 위하여 1차원 배열 탐촉자를 손으로 조작하는 동안 변하는 방사빔의 위치를 추적하여 정적인 3차원 초음파영상을 구성하였다. 탐촉자에 고정된 모션센서의 병진운동 및 회전운동에 대한 정보를 기준직교좌표계로 변환하는 이론적 모델을 제시하였으며, 신호 증폭과 시리얼 통신을 위한 인터페이스 용도의 모듈을 상용의 센서를 사용하여 제작하였다. 실리콘 퍼티로 제작된 시험용 팬텀에 대한 B-모드의 동영상과 센서의 신호를 동기화하여 기록하였다. 동영상으로부터 주기적으로 추출한 B-모드 영상과 각 영상내의 픽셀 각각의 그레이 레벨을 이용하여 3차원 복셀의 그레이 레벨을 재구성하였다. 이 복셀의 데이터를 이용하여 3차원 영상과 임의단면의 B-모드 방식의 2차원 영상을 구성하였으며, 이 영상들은 시험용 팬텀의 형상과 잘 일치하였다.

Reynolds 수가 2단 원추형 5공프로브를 이용한 3차원 유동 측정에 미치는 영향 - 저속 유동장에서의 보정 결과 - (The Effect of Reynolds Number on the Three-Dimensional Flow Measurements with a Two-Stage Cone-Type Five-Hole Probe in a Non-Nulling Mode)

  • 이상우;전상배
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.27-38
    • /
    • 2002
  • The effects of Reynolds number on the non-nulling calibrations of a cone-type ave-type probe in low-speed flows have been investigated at Reynolds numbers of 2.04$\times$10$^3$, 4.09$\times$10$^3$and 6.13$\times$10$^3$. The calibration is conducted at the pitch and yaw angles in ranges between -35 degrees and 35 degrees with an angle interval of 5 degrees. In addition to the calibration coefficients, reduced pitch and yaw angles, static and total pressures, and velocity magnitude are obtained through a typical non-nulling reduction procedure. The result shows that each calibration coefficient, in general, is a function of both the pitch and yaw angles, so that the pre-existing calibration data in a nulling mode are not enough in accounting far the full non-nulling calibration characteristics. Due to interference of the probe stem, the calibration coefficient are more sensitive to Reynolds number at positive pitch angles than at negative ones. The calibration data reduced in this study may serve as a guide line in the estimation of uncertainty intervals resulted from the Reynolds number effects at low Reynolds numbers.

Thiol-ene 반응을 이용한 UV경화형 SIS/SBS계 점착제의 점착물성 (Pressure Sensitive Adhesion Performances of SIS/SBS based UV-curable Pressure Sensitive Adhesives using Thiol-ene Reaction)

  • 임동혁;도현성;김현중;윤관희;방정석
    • 접착 및 계면
    • /
    • 제6권3호
    • /
    • pp.19-25
    • /
    • 2005
  • 합성 고무계 점착제는 일반적으로 SIS나 SBS 블록 공중합체와 점착부여수지, 가소제, 기타 첨가제를 함유한다. SIS/SBS 계 점착제는 우수한 접착력에도 불구하고 내용제성이나 내열성이 낮아서 그 사용에 한계가 있다. 이에 이러한 단점을 보완하고자 SIS/SBS 점착제에 가교제, 광개시제를 주성분으로 하는 자외선 경화 시스템을 도입하였다. 제조된 점착제는 thiol-ene 광중합 반응에 의해 가교하였으며 점착제의 프로브 택(probe tack), 박리강도(peel strength) 전단접착파괴온도(shear adhsion failure temperature, SAFT)를 측정하여 UV 경화형 점착특성을 고찰하였다. 또한 UV 경화형 점착제의 택 성질을 프로브 택을 이용하여 프로브 재료별, 점착제의 두께별의 영향을 살펴보았고 접촉각 측정을 통해 점착제 표면 변화를 살펴보았다.

  • PDF

전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향 (Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method)

  • 이복희;어주홍;김성원
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.97-104
    • /
    • 2001
  • 본 논문에서는 전위강하법에 의한 접지저항 측정시 전위보조전극 위치의 영향에 대하여 기술하였다. 전위강하법에서 접지저항은 이론적으로 전위보조전극을 피측정 접지전극과 전류보조전극이 이루는 일직선상에 위치시킬때 61.8[%]법칙을 적용하여 측정한다. 하지만 측정현장의 사정상 전위보조전극의 위치를 피측정 접지전극과 전류 보조전극이 이루는 일직선과 어느 정도의 각도를 가지도록 시설하여 접지저항을 측정하게 될 경우에 측정오차가 발생하게 되고 보정이 필요하다. 본 연구에서의 측정대상 전극은 길이 2.4 [m]의 봉형 접지전극으로 하였으며, 피측정 접지전극, 전위보조전극, 전류보조전극이 일직선상에 놓이지 않은 상태에서 접지저항을 측정하면 측정값은 항상 (-)의 오차를 나타내었고, 이들 전극이 이루는 각도가 증가함에 따라 측정 오차도 증가하였다.

  • PDF

모래지반에서 원형기초의 수직-수평 조합하중 지지력과 경사계수에 대한 수치해석 연구 (Numerical Studies on Combined VH Loading and Inclination Factor of Circular Footings on Sand)

  • 김동준;윤준웅;지성현;최재형;이진선;추연욱
    • 한국지반공학회논문집
    • /
    • 제30권3호
    • /
    • pp.29-46
    • /
    • 2014
  • 모래지반의 지표면에 위치한 거친 바닥면을 가진 강체 원형기초에 대하여 삼차원 수치해석을 통하여 수직-수평 조합하중 조건에서의 지지력을 구하였다. 조합하중 상관도를 효율적으로 산출할 수 있는 swipe 재하방법과 실제 구조물의 하중 조건과 유사한 probe 재하방법을 모사할 수 있는 수치모델을 구현하였으며 요소망의 조밀도에 의한 오차를 소거할 수 있는 분석 절차를 개발하였다. Mohr-Coulomb 소성모델을 사용하고 관련흐름법칙을 적용하여 지반의 내부 마찰각에 따른 수직-수평 조합하중에 대한 지지력 상관도와 경사계수를 산출하였다. Swipe 재하방법의 결과는 probe 재하방법을 사용한 결과와 유사함을 확인하였으며, 거친 바닥면 조건에서 수직-수평 조합하중 지지력 상관도의 내부 마찰각에 따른 변화는 미미하고, 원형기초에 대해서 연속기초 및 사각형기초와 동일한 경사계수를 적용할 수 있는 것으로 나타났다. 하중의 경사가 큰 경우에는 수치모델링을 통해 산출된 원형기초에 대한 지지력 상관도와 경사계수는 기존의 연구 결과보다 작게 평가되었으며, 수치모델링 결과에 영향을 미치는 요인과 향후 연구 방향에 대하여 고찰하였다.

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • 한국전문물리치료학회지
    • /
    • 제18권4호
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.