• 제목/요약/키워드: Prime & Bond NT

검색결과 24건 처리시간 0.02초

레진 시멘트와 상아질접착제를 사용한 콤포지트 레진 코아의 전단결합강도에 관한 연구 (SHEAR BOND STRENGTH OF COMPOSITE RESIN CORE USED IN COMBINATION WITH VARIOUS RESIN CEMENTS AND DENTIN BONDING AGENTS)

  • 김현오;방몽숙
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.30-40
    • /
    • 2004
  • Purpose : The purpose of this study was aimed to compare the shear bond strength on dentin of three dentin bonding agents and two resin cements used in conjunction with self-cured composite resin core material. Material and method : Control group and six experimental groups were divided for this study. Control group was designated as specimens bonded with Tenure$ A&B^{(R)}$. Experimental groups were as follows : PB-BL group : specimens bonded with Prime&Bond $NT^{(R)}$, $BondLink^{(R)}$ SB-BL group : specimens bonded with $^{(R)}$, BondLink$SingleBond^{(R)}$ PB group : specimens bonded with Prime&Bond $NT^{(R)}$ SB group : specimens bonded with $SingleBond^{(R)}$ PF group : specimens bonded with $Panavia-F^{(R)}$ BI group specimens bonded with Bistite $II^{(R)}$ All specimens were stored in $37^{\circ}C$ distilled water for 24 hours, followed by the shear bond strength was tested by universal testing machine. The data was analysed statistically by Mann-Whitney test. Results : 1. For Prime&Bond $NT^{(R)}$ and $SingleBonde^{(R)}$, the shear bond strength was 0.24 MPa and 7.19 MPa each by each, while Tenure $A&B^{(R)}$ group control was measured at 13.93 MPa (p<0.05). Especially for Prime&Bond $NT^{(R)}$ it did not get conjunction with dentin. 2. For Prime&Bond $NT^{(R)}$ and $SingleBond^{(R)}$ using $BondLink^{(R)}$, there was no significant difference as a result of 11.73 MPa and 14.00 MPa each by each (p<0.05). 3. For $Panavia-F^{(R)}$ and Bistite $II^{(R)}$, they showed the highest shear bond strength as measured by 18.24 MPa and 16.09 MPa each (p<0.05).

상아질 접착제에 포함된 활성제의 사용 유무가 자가중합 복합레진의 상아질에 대한 전단결합강도에 미치는 영향 (Effects of activators contained in adhesives on dentin bond strengths)

  • 강혜경;신주희;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.511-519
    • /
    • 2008
  • 연구목적: 본 연구의 목적은 자가중합 또는 이중중합을 위한 활성제가 포함된 상아질 접착제에서 활성제의 사용 유무가 자가중합 복합레진과 상아질 접착제간의 전단결합강도에 미치는 영향을 평가하는 것이다. 연구 재료 및 방법: 실험을 위하여 우식 및 충전물이 없는 건전한 대구치 50개를 주문제작한 아크릴릭 레진블록에 포매한 후, 모델 트리머로 연마하여 평활한 상아질면을 만든 후, 600grit 실리콘 카바이드 페이퍼로 연마하고 증류수에 보관하였다. 50개의 시편을 10개씩 5개 군으로 나눈 후, 상아질 접착제를 제조사의 지시대로 도포한 후, 플라스틱 주형을 이용하여 자가중합 복합레진 (Luxacore)을 접착시켰다. 상아질 접착제는 One-Step (OS군), Prime&Bond NT, AdheSE를 이용하였는데 Prime&Bond NT와 AdheSE는 단독으로 사용한 군 (PB군, AS군)과 활성제를 같이 사용한 군 (PBA군, ASA군)으로 다시 나누었다. 증류수에 24시간 보관 후, 인스트론 만능시험기를 사용하여 시편에 1 mm/min의 전단속도로 하중을 가하여 시편이 분리되는 최대 하중을 측정한 뒤, 단위 면적 당 결합강도 (MPa)로 환산하여 One-way ANOVA를 이용하여 비교, 분석하고 5% 유의수준에서 Tukey HSD 검정을 이용하여 분석하였다. 결과: 각 군의 전단결합강도의 평균을 보면, OS군이 18.6 MPa로 가장 높았고 그 다음이 PBA군 (10.3 MPa)과 ASA군 (10.2 MPa)이었고, PB군과 AS군이 각각 5.9 MPa, 6.0 MPa로 가장 낮은 전단결합강도를 나타내었다. 결론: 본 실험을 통해 Prime&Bond NT와 AdheSE에서 활성제를 같이 사용한 경우, 활성제를 사용하지 않은 경우보다 전단결합강도가 높아짐을 알 수 있었지만, 활성제가 포함되어 있지 않은 One-Step보다는 낮은 수치였다.

수종의 단일병 접착제의 적용 시간 연장이 건조 상아질의 미세인장 결합강도에 미치는 영향 (EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN)

  • 김학근;김동준;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.435-441
    • /
    • 2005
  • 본 연구는 친수성 용매가 함유되어 있는 3종의 단일병 접착제의 적용 시간을 증가시켰을 때, 건조 상아질에 대한 재습윤의 효과가 있는지를 미세인장 결합강도의 측정을 통해 알아보고자 시행하였다. 실험대상은 최근에 발거한 상하악의 대구치로, 교합면 1/3부위의 치질을 치아 장축에 수직으로 절단하여 상아질을 노출시킨 후, $32\%$인산 (Unietch, Bisco Inc., Schaumburg, IL, USA)으로 15초간 산부식 하고 수세하였다. 치아는 무작위로 S군 (Single Bond), O군 (One-Step), P군 (Prime & Bond NT)으로 분류하였고, 각 군은 다시 3군 (W: 상아질 표면의 남아있는 과잉의 물을 수분에 적신 거즈를 이용하여 제거한 후, 즉시 단일병 접착제를 적용하고 광중합, D : 30초간 건조 한 후 즉시 단일병 접착제를 적용하고 광중합, 30: 30초간 건조 한 후 단일병 접착제를 30초간 적용하고 광중합)으로 소 분류하였다. 접착제 도포 후, 복합레진을 축조하고 접착계면이 $1mm^2$가 되도록 절단하여 각 군당 20개의 표본을 사용하여 미세인장 결합강도를 측정하였다. 5군,0군의 30초 적용군 (S-30, O-30)은 건조군 (S-D, O-D)보다 높은 미세인장 결합강도를 보였으며, S-30군의 경우 S-D군보다 통계학적으로 유의성 있게 높았다 (P<0.05). 하지만, P군의 30초 적용군 (P-30)은 건조군 (P-D)에 비해 미세인장 결합강도가 통계학적으로 유의성 있게 감소하였다 (P<0.05).

One-Bottle 상아질 결합제의 유치 상아질에 대한 전단 결합 강도에 관한 연구 (SHEAR BOND STRENGTH OF "ONE-BOTTLE ADHESIVE" SYSTEM IN PRIMARY DENTIN.)

  • 김종빈;김종수
    • 대한소아치과학회지
    • /
    • 제27권3호
    • /
    • pp.444-456
    • /
    • 2000
  • 치아 교환시기에 발거된 치관이 건전한 유구치 상아질 표면을 One-Bottle 상아질 결합제인 Primer & Bond NT(DeTrey/Dentsply, Konstanz, Germany)와 Single Bond(3M Co. U.S.A.) 그리고 대조군으로 Scotchbond Multipurpose System(3M Co. U.S.A.)를 이용하여 각 제조자의 지침에 따라 처리하여 레진을 충전하고 광중합하였다. 1. 전단 결합 강도의 측정결과 Primer & Bond NT군인 1군, Single Bond군인 2군, 그리고 대조군으로 사용된Scotchbond Multipurpose System군인 3군의 순서로 1군에서 다소 높은 전단 결합 강도를 보였으나, 모든 군들간에는 통계적 유의차가 없었다(p>.05). 2. 주사 전자현미경 소견에서 1군 2군에서 서로 유사한 양상의 잘 형성된 혼화층이 관찰되었으며, 레진 테그와 측방 가지 또한 다수 관찰되었다. 반면 3군에서는 혼화층이나 측방가지의 형성이 1, 2군에 비해 다소 미약한 양상을 보였다.

  • PDF

타액 오염이 One bottle 상아질 결합제의 전단결합강도에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECT OF SALIVA CONTAMINATION ON THE BOND STRENGTH OF ONE-BOTTLE ADHESIVE SYSTEM)

  • 전형준;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.566-574
    • /
    • 2001
  • 법랑질과 상아질에 대한 접착시스템의 결합력은 타액이나 혈액에 의하여 저하될 수 있다. 제 5세대 상아질 결합제 적용시에 산부식된 치면이 타액에 오염될 경우, 보다 효율적인 치면 처리 방법을 알아보기 위해 여러 가지 치면 처리 방법과 조건을 설정한 다음 수복물의 유지력을 전단결합강도 측정으로 서로 비교 분석하고, 치아와 수복물 사이의 계면을 주사전자 현미경을 이용해 관찰하였다. 그 결과 우치상아질의 산부식후 타액오염된 경우, 물로 10초간 세척한 후 공기로 가볍게 건조하여 수복하면 전단결합강도의 감소가 일어나지 않았으나, Prime & Bond NT의 광중합후에 타액오염된 경우에는 물로 10초간 세척한 후 공기로 완전히 건조를 하여도 레진과의 결합력이 매우 약해지며 Prime & Bond NT를 재적용하더라도 전단결합강도의 상당한 감소를 보였으며, 주사전자 현미경 관찰결과 모든 군에서 유사한 혼화층과 레진태그의 형성을 보였으며 특이할만한 각 군간의 차이를 관찰할 수 없었다.

  • PDF

상아질 접착제의 성상이 미세인장결합강도에 미치는 영향 (THE EFFECT OF ADHESIVE PROPERTY ON MICROTENSILE BOND STRENGTH TO HUMAN DENTIN)

  • 김현진;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.281-287
    • /
    • 2004
  • The purposes of this study were to evaluate the effect of adhesive property on microtensile bond strength and to determine the failure mode. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. The dentin was etched with 37% phosphoric acid. The following adhesives were applied to the etched dentin to manufacturer's directions: Scotchbond Multi-Purpose in group SM, Prime&Bond NT in group NT, Scotchbond Multi-Purpose followed by Tetric-flow in group TR. After adhesive application, a cylinder of resin-based composite was built up on the occlusal surface. Each tooth was sectioned vertically to obtain the $1{\;}{\times}{\;}1\textrm{mm}^2$ "sticks". Microtensile bond strength were determined. Each specimen was observed under stereomicroscope and scanning electron microscope (SEM) to examine the failure mode. Data were analyzed using one way ANOVA. The results of this study were as follows:1. The microtensile bond strength value were:group SM ($18.98{\pm}3.01MPa$). group NT ($16.01{\pm}4.82MPa$) and group TR ($17.56{\pm}3.22MPa$). No significant statistical differences were observed among the groups (P>0.05). 2. Most of specimens showed mixed failure. In group TR, there was a higher number of specimens showing areas of cohesive failure in resin.

치아 맹출 유무에 대한 자가부식 접착제에 의한 교정용 부착장치의 접착강도 (Effects of conventional and self-etching adhesive systems on bond strength of orthodontic attachments bonded to erupted and unerupted teeth)

  • Nur, Metin;Uysal, Tancan;Yesilyurt, Cemal;Bayram, Mehmet
    • 대한치과교정학회지
    • /
    • 제40권4호
    • /
    • pp.267-275
    • /
    • 2010
  • 이번 연구의 목적은 맹출 또는 미맹출된 치아에 교정용 버튼을 부착 후 자가부식 접착제(self-etching adhesive)의 사용 유무에 대한 전단결합강도(shear bond strength)와 탈락모드를 비교하고자 함이다. 각각 84개의 맹출 또는 미맹출된 제3대구치를 사용하였다. 각각 치아의 협측면을 다음의 부착시스템 그룹으로 할당하였다. A, 기존방식: 1, Transbond XT (3M Unitek); 2, Prime & Bond NT (Dentsply/Caulk); 3, Single Bond (3M ESPE); B, 자가부식 접착제; 4, Clearfil SE Bond (Kuraray); 5, Transbond Plus (3M Unitek); 6, Clearfil S3 (Kuraray); 7, G Bond (GC). 부착물의 전단강도와 접착제 잔류지수를 측정하였으며 결과값은 ANOVA와 independent t-test 및 chi-square 검증을 통해 분석되었다. 맹출 또는 미맹출된 치아의 전단결합강도를 비교하였을 때 Clearfil SE와 G Bond에서 유의한 차이가 관찰되었다. Single Bond를 제외한 모든 접착시스템에서 맹출보다는 미맹출 치아면에서 높은 접착강도가 관찰되었다. 기존 접착제를 사용하는 경우 맹출 또는 미맹출 치아에 대한 접착강도에는 차이가 없을 수 있다. 그러나 임상의사는 사용 전에 self-etching system의 종류를 고려할 필요가 있다.

수복재에 함유된 불소가 치질의 미세경도와 불소 함유량에 미치는 영향 (INFLUENCE OF MICROHARDNESS AND FLUORIDE CONTENT OF TOOTH STRUCTURE BY FLUORIDE-CONTAINING RESTORATIVE MATERIALS)

  • 이수종;조영곤;김종욱;박병철
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.36-43
    • /
    • 2004
  • The purpose of this study was to compare the microhardness and the fluoride content of enamel and dentin around fluoride- or non fluoride-containing restorations. Forty extracted human teeth were used and prepared cervical cavities on proximal surface. Experimental teeth were divided into five groups . Group 1 : Prime & Bond NT and Z100, Group 2 Prime & Bond NT and F2000, Group 3 : Scotchbond Multi-purpose and Z100, Group 4 : Scothcbond Multi-purpose and F2000, Group 5 : Fuji II LC. The cavities were filled with dentin adhesives and restorative materials. After each tooth was bisected, one half was tested microharaness and the other half was analyzed the fluoride at the enamel and dentin by an EPMA-WDX device. The results were as follows; 1. There was no statistical difference among the microhardness of enamel surface in all group. 2. The microhardness at dentin of $100{\;}\mu\textrm{m}$ point in Group 2 and $20{\;}\mu\textrm{m}$ point in Grocup 4 was lower than that of normal dentin (p>0.05). 3. There was no statistical difference among the fluoride content of enamel surface in all group. 4. The fluoride content at the dentin of $30{\;}\mu\textrm{m}$ point in Group 2 and 5 were higher than those at $100{\;}\mu\textrm{m}{\;}and{\;}200{\;}\mu\textrm{m}$ point in Group 2 and normal dentin (p<0.05). 5. At the dentin of $30{\;}\mu\textrm{m}$ point, Group 2 showed higher fluoride content than Group 1 and 3, and Group 5 showed higher fluoride content than other groups.

The Effect of Cavity Configuration on the Mechanical Properties of Resin Composites.

  • Ryu, G.J.;Park, S.J.;Choi, K.K.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.576.1-576
    • /
    • 2001
  • The objective of this study was to evaluate the effect of configuration of cavity on the mechanical properties such as flexural strength and elastic modulus of resin composites. The materials used were $Clearfil^{TM}$ AP-X(Kuraray, Japan) and $Esthet-X^{TM}$(Dentsply, USA) as resin composite. Dentin-bonding systems used in the study were $Clearfil^{TM}$ SE Bond(Kuraray, Japan) and Prime & Bond $NT^{TM}$(Dentsply, USA). The specimens were prepared as 6 groups with 2 control groups and 4 experimental groups.(omitted)

  • PDF

미세-전단 결합 강도 시험을 이용한 상아질 접착제와 수복용 복합 레진의 호환성에 관한 연구 (IN VITRO MICRO-SHEAR BOND STRENGTH OF FIVE COMPOSITE RESINS TO DENTIN WITH FIVE DIFFERENT DENTIN ADHESIVES)

  • 정진호;노병덕
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.353-364
    • /
    • 2004
  • The purpose of this study was to compare and to evaluate the combination use of 5 kinds of dentin adhesive systems and 5 kinds of composite resins using micro-shear bond test. Five adhesive systems (Prime & Bond NT (PBN). Onecoat bond (OC), Excite (EX), Syntac (SY), Clearfil SE bond (CS)) and five composite resins (Spectrum (SP), Synergy Compact (SC), Tetric Ceram (TC), Clearfil AP-X (CA), Z100 (Z1)) were used for this study ($5{\;}{\times}{\;}5{\;}={\;}25group$, n =14/group). The slices of horizontally sectioned human tooth were bonded with each bonding system and each composite resin, and tested by a micro-shear bond strength test. These results were analyzed statistically. The mean micro-shear bond strength of dentin adhesive systems were in order of CS (22.642 MPa), SY (18.368 MPa), EX (14.599 MPa). OC (13.702 MPa). PBN (12.762 MPa). The mean bond strength of self-etching primer system group (CS, SY) in dentin was higher than that of self-priming adhesive system groups (PBN, EX, OC) significantly (P<0.05). The mean bond strength of composite resins was in order of SP (19.008 MPa), CA (17.532 MPa). SC (15.787 MPa), TC (15.068 MPa). Z1 (14.678 MPa). Micro-shear bond strength of SP was stronger than those of other composite resins significantly (P < 0.05). And those of TC and Z1 were weaker than other composite resins significantly (P < 0.05). No difference was found in micro-shear bond strength of composite resin in self-etching primer adhesive system groups (CS, SY) statistically. However, there was significant difference of micro-shear bond strength of composite resin groups in self-priming adhesive systems group (PBN, EX, OC). The combination of composite resin and dentin adhesive system recommended by manufacturer did not represent positive correlation. It didn't seem to be a significant factor.