• Title/Summary/Keyword: Primary link

Search Result 196, Processing Time 0.022 seconds

Variable Charger of Vehicle using Relay (릴레이를 이용한 차량용 배터리의 가변 충전기)

  • Song, Sung-Geun;Chung, Seung-Tae;Kang, Sung-Gu;Lee, Sang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.47-56
    • /
    • 2012
  • This research is to develop satiable battery charger with a variety of capacity and voltage specifications of battery. For this, voltage or current were controlled through buck converter which is DC voltage that already received three-phase at primary side and passed bridge rectifier diode. And, it was comprised of full-bridge converter and HFTR for insulation and a square wave AC. The transformer primary side was comprised in series to divide certain charging current and the secondly side was comprised of 6 fixed transformers so that they can generate certain amount of power and various output voltage through relay parallel compound 6 DC Link outputs. To confirm such structure's verification and validity, simulation with PSIM was conducted, and validity of proposed variable charger system was verified through 3kW stack production.

Multihoming Effect of SCTP Over TCP in the Link-down Environment (링크다운 환경에서 TCP어| 대한 SCTP의 멀티호밍 효과)

  • Choi, Yong-Woon;Lee, Yong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.8
    • /
    • pp.73-83
    • /
    • 2009
  • TCP(Transmission Control Protocol) is currently used connection-oriented protocol as a typical transport layer protocol in the Internet. However, it has deficiency not be able to communicate with other TCP entities when any link included in the path is down because of single-homing on single path. SCTP(Stream Control Transmission Protocol) suggested as the new transport layer protocol supports multi-homing feature, which provides several paths between source and destination. It can communicate with other SCTP entities using alternate path even when any link on the primary path is down. This paper aims to measure and analyze the multi-homing effect of SCTP over TCP in case of link-down using NS-2 simulator. We classify SCTP into $SCTP_{single-homing}$ and $SCTP_{multi-homing}$ because SCTP with single-homing can also be used like TCP. We measured throughput and bandwidth utilization varying link-down duration, bandwidth, and RTT(round trip time), Simulation results show that throughput of $SCTP_{multi-homing}$ is more than that of TCP by 18 % on average. It is also shown that $SCTP_{multi-homing}$ on varying RTT and bandwidth increases the throughput of TCP by 'l7% and 9% on average, respectively in the link-down environment. In above cases, more or less difference between $SCTP_{single-homing}$ and TCP on throughput and bandwidth utilization was found To summarize, multi-homing effect of SCTP over TCP on throughput is about 18 % on average in the link-down environment This experimental result can be used as the benchmark in order to estimate the multi-homing effect of SCTP over TCP when the link-down happens in the real Internet.

Security-Aware Optimized Link Routing Protocol for Mobile Ad-Hoc Networks

  • Dhir, Amandeep;Sengupta, Jyotsna
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.1
    • /
    • pp.52-83
    • /
    • 2009
  • In this technical report, we have examined the basic building blocks of mobile ad-hoc networks. The paper discusses various security requirements of ad-hoc networks, attacks in ad-hoc networks, Security Implementation and Routing Protocols. The primary purpose of the paper is to address the Optimized Link State Routing (OLSR) protocol in detail, along with the various possible attacks. Finally, algorithms for securing OLSR are proposed, via the addition of digital signatures, as well as more advanced techniques such as cross checking of advertised routing control data with the node's geographical position. The main aim of this research work is the addition of security features to the existing OLSR protocol. In order to effectively design a secure routing protocol, we present a detailed literature survey of existing protocols, along with the various attacks. Based on the information gathered from the literature survey, a secure routing protocol for OLSR is proposed. The proposed secure routing protocol involves the addition of a digital signature as well as more advanced techniques such as the reuse of previous topology information to validate the actual link state. Thus, the main objective of this work is to provide secure routing and secure data transmission.

Numerical investigation on the flexural links of eccentrically braced frames with web openings

  • Erfani, S.;Vakili, A.;Akrami, V.
    • Steel and Composite Structures
    • /
    • v.39 no.2
    • /
    • pp.171-188
    • /
    • 2021
  • Plastic deformation of link beams in eccentrically braced frames is the primary dissipating source of seismic energy. Despite the excellent compatibility with the architectural designs, previous researches indicate the deficiency of flexural yielding links compared to the shear yielding ones because of their localized plastic deformation. Previous investigations have shown that implementing web openings in beams could be an efficient method to improve the seismic performance of moment-resisting connections. Accordingly, this research investigates the use of flexural links with stiffened and un-stiffened web openings to eliminate localized plasticity at the ends of the link. For this purpose, the numerical models are generated in finite element software "Abaqus" and verified against experimental data gathered from other studies. Models are subjected to cyclic displacement history to evaluate their behavior. Failure of the numerical models under cyclic loading is simulated using a micromechanical based damage model known as Cyclic Void Growth Model (CVGM). The elastic stiffness and the strength-based and CVGM-based inelastic rotation capacity of the links are compared to evaluate the studied models' seismic response. The results of this investigation indicate that some of the flexural links with edge stiffened web openings show increased inelastic rotation capacity compared to an un-perforated link.

Numerical investigation on the flexural links of eccentrically braced frames with web openings

  • Erfani, S.;Vakili, A.;Akrami, V.
    • Steel and Composite Structures
    • /
    • v.44 no.2
    • /
    • pp.183-198
    • /
    • 2022
  • Plastic deformation of link beams in eccentrically braced frames is the primary dissipating source of seismic energy. Despite the excellent compatibility with the architectural designs, previous researches indicate the deficiency of flexural yielding links compared to the shear yielding ones because of their localized plastic deformation. Previous investigations have shown that implementing web openings in beams could be an efficient method to improve the seismic performance of moment-resisting connections. Accordingly, this research investigates the use of flexural links with stiffened and un-stiffened web openings to eliminate localized plasticity at the ends of the link. For this purpose, the numerical models are generated in finite element software "Abaqus" and verified against experimental data gathered from other studies. Models are subjected to cyclic displacement history to evaluate their behavior. Failure of the numerical models under cyclic loading is simulated using a micromechanical based damage model known as Cyclic Void Growth Model (CVGM). The elastic stiffness and the strength-based and CVGM-based inelastic rotation capacity of the links are compared to evaluate the studied models' seismic response. The results of this investigation indicate that some of the flexural links with edge stiffened web openings show increased inelastic rotation capacity compared to an un-perforated link.

Robust Power Control for Cognitive Radio in Spectrum Underlay Networks

  • Zhao, Nan;Sun, Hongjian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.7
    • /
    • pp.1214-1229
    • /
    • 2011
  • Power control is a key technique in spectrum underlay cognitive network to guarantee the interference temperature limit of the primary users (PUs) and the quality of service of the secondary users (SUs). In this paper, a robust power control scheme via link gain pricing with $H_{\infty}$ estimator is proposed. The scheme guarantees the interference temperature of the PUs through operating in the network-centric manner, and keeps the fairness between the SUs through link gain pricing. Furthermore, the $H_{\infty}$ filter is also used in the proposed scheme to estimate the channel variation, and thus the power control scheme is robust to the severe channel fading. Plenty of simulations are taken, and prove its superior robust performance against the channel fading, and its effectiveness in guaranteeing the interference temperature limit of the PUs.

An Efficient Throughput Improvement through Bandwidth Awareness in Cognitive Radio Networks

  • Le, Tung Thanh;Kim, Dong-Seong
    • Journal of Communications and Networks
    • /
    • v.16 no.2
    • /
    • pp.146-154
    • /
    • 2014
  • This paper proposes a bandwidth-aware localized-routing algorithm that is capable of sensing the available spectrum bands within a two-hop neighboring for choosing the highly opportunistic routes. A mixed-integer linear programming (MILP) is utilized to formulate the optimization problem. Then, the proposed algorithm is used to determine the maximum bandwidth possible of link pairs via a bandwidth approximation process of relaxed variables. Thereby, the proposed algorithm can allow selected routes corresponding to maximum bandwidth possible between cognitive radio (CR) users through link pairs in cognitive radio networks. By comparing the solution values to previous works, simulation results demonstrate that the proposed algorithm can offer a closed-optimal solution for routing performance in cognitive radio networks. The contribution of this paper is achieved through approximately 50% throughput utilized in the network.

Control Technique for High Frequency Link Current-Fed Inverter (고주파 링크 전류원 인버터의 제어기법)

  • Kim Seok-Hwan;Lim Jung-Gyu;Chung Se-Kyo;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.795-798
    • /
    • 2004
  • This paper describes a control technique for a high frequency (HF) link current-fed inverter with a single power conversion stage. The switching and control techniques for the primary full-bridge inverter and secondary cycloconverter are presented for generating a sinusoidal output voltage. The simulation and experimental results are provided to show the validity of the proposed control technique.

  • PDF

The Comparison of Running Performances between Various Steering-type Guideway Vehicles (조향방식 안내궤도 차량들의 주행 안정성 비교)

  • 윤성호
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.1
    • /
    • pp.18-25
    • /
    • 2002
  • This paper is to study a comparison of ride stabilities for the guideway vehicle between its three primary steering types; the front-rear wheel steering type, tile independent wheel steering and the front wheel steering. A numerical model were built to investigate various factors to have an influence on the vehicular stability. It was shown that dynamic stabilities of the three types were dependent on the steering gain ratio of front wheel steering to rear. The front-rear wheel steering type was more stable for the value of positive steering gains and the shorter distance between front axle and guide link showed better stabilities. On the contrary, the independent wheel steering was more stable for the value of negative gains and the longer distance between front axle and guide link showed better stabilities. Ride characteristics of he front wheel steering seemed to be found midway. Ride behaviors due to time delay from front steering to rear were very different from steering type to type.

A PI-based Control Scheme for Primary Cascaded H-Bridge Rectifier in Transformerless Traction Converters

  • Tao, Xing-Hua;Li, Yong-Dong;Sun, Min
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.360-365
    • /
    • 2012
  • Cascaded H-Bridge rectifier (CHBR) is a more attractive solution in traction application for its transformerless structure. Because of the currents of different cells are exactly the same one, it is a challenge job to regulate the voltages of cells with only one current controller. In this paper, a PI-based control scheme is presented to deal with the voltages balance issue in CHBR. To satisfy the demand of rectifier such as unity power factor and regulated output DC voltages, the proposed control scheme consists of two parts. One is for shaping the grid current waveform and regulating the sum of DC-link voltages of all the cells; the other one is for balancing DC-link voltages. The latter is more concerned in this paper and is discussed in detail especially. Simulations and experiments are carried on. The results verified the feasibility and effectiveness of the proposed scheme.