• Title/Summary/Keyword: Primary dentin

Search Result 72, Processing Time 0.023 seconds

Detection of Hidden Proximal Caries using Q-ray view in Primary Molars (Q-ray view를 이용한 유구치의 숨은 인접면 우식증 탐지)

  • Jeong, Younwook;Lee, Hyoseol;Choi, Hyungjun;Lee, Jaeho;Choi, Byungjai;Kim, Seongoh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.209-217
    • /
    • 2015
  • The purpose of this study was to evaluate the ability of Q-ray view (All-in-one Bio, Seoul, Korea) in detection of proximal caries in primary molars with sound marginal ridges. Thirty two children aged 3-9 years (average $5.6{\pm}1.3$ years old) were chosen, and two examiners evaluated 100 proximal surfaces of primary molars with sound marginal ridges. The teeth were examined with; (a) visual examination, (b) Q-ray view, (c) DIAGNOdent (KaVo, Biberach, Germany) and (d) digital periapical radiography. Kappa statistic was used to assess the agreement between each examination method and the degree of caries progression. The kappa values for enamel caries were 0.15 (visual examination), 0.10 (Q-ray view), 0.25 (DIAGNOdent) and 0.68 (digital periapical radiography). The kappa values for dentinal caries were 0.34 (visual examination), 0.56 (Q-ray view), 0.44 (DIAGNOdent) and 0.70 (digital periapical radiography). Although Q-ray view showed low diagnostic ability in detection of enamel caries, it was effective in detection of hidden proximal caries extended into dentin. Q-ray view would be a useful and simple device which could aid pediatric dentists in detection of hidden proximal caries in primary molars especially when examining uncooperative children or disabled persons.

Detecting of Proximal Caries in Primary Molars using Pen-type QLF Device (펜-타입 QLF 장비의 임상적 유구치 인접면 우식 탐지 성능)

  • Cho, Hyejin;Kim, Hyuntae;Song, Ji-Soo;Shin, Teo Jeon;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.405-413
    • /
    • 2021
  • The purpose of this in vivo study was to assess the clinical screening performance of a quantitative light-induced fluorescence (QLF) device in detecting proximal caries in primary molars. Fluorescence loss, red autofluorescence and a simplified QLF score for proximal caries (QS-proximal) were evaluated for their validity in detecting proximal caries in primary molars compared to bitewing radiography. Three hundred and forty-four primary molar surfaces were included in the study. Carious lesions were scored according to lesion severity assessed by visual-tactile and radiographic examinations. The QLF images were analyzed for two quantitative parameters, fluorescence loss and red autofluorescence, as well as for QS-proximal. For both quantitative parameters and QS-proximal, the sensitivity, specificity and area under receiver operating curve (AUROC) were calculated as a function of the radiographic scoring index at enamel and dentin caries levels. Both quantitative parameters showed fair AUROC values for detecting dentine level caries (△F = 0.794, △R = 0.750). QS-proximal showed higher AUROC values (0.757 - 0.769) than that of visual-tactile scores (0.653) in detecting dentine level caries. The QLF device showed fair screening performance in detecting proximal caries in primary molars compared to bitewing radiography.

THE EFFECTS OF FORMOCRESOL AND GLUTARALDEHYDE ON THE PERFORATED INTERRADICULAR TISSUES AND TOOTH GERMS OF PRIMARY TEETH IN DOGS (Formocresol, Glutaraldehyde가 유견 계승치 치배 및 주위조직에 미치는 영향에 관한 병리조직학적 연구)

  • Choi, Byung-Jai;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.8 no.1
    • /
    • pp.55-63
    • /
    • 1981
  • The purpose of this study is to observe the effect of formocresol and glutaraldehyde to tooth germs and periapical tissues after perforation of interradicular portion of pulpal floor and application of physiological saline solution in control groups, formocresol and glutaraldehyde in experimental groups. The following results were obtained 1. In control groups, normal healing processes were seen, and, on the sixteenth day, the epithelization of injured areas was completed. Inflammatory reactions were limited to the injured surface, and the underlying alveolar bone were normal and successive tooth germs were normal. 2. In both formocresol groups and glutaraldehyde groups, tissue reactions were identical. Inflammatory reactions were slightly compared with control groups, but the surface epithelizations were delayed compared with control group. 3. In both formocresol and glutaraldehyde groups, necrosis was seen in superficial tissue of bone marrow, and, at 24th day, center area of bone marrow on the successive tooth germs were losed and replaced with connective tissue, and superficial soft tissue of the injured area was connected with soft tissue on the successive tooth germ. In remaining alveolar bone, osteoclastic reaction was remarkable. 4. In both formocresol and glutaraldehyde groups, there is no injury to the successive tooth germs. 5. In both formocresol and glutaraldehyde groups, periodontal membrane was normal, but the partial resorption of cementum and dentin near the injured area were seen.

  • PDF

CLINICAL, RADIOGRAPHIC AND HISTOPATHOLOGIC ANALYSIS OF ODONTOMA (치아종의 임상적, 방사선학적, 조직병리학적 분석)

  • Jang, Hyun-Seon;Kim, Su-Gwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.4
    • /
    • pp.332-337
    • /
    • 2001
  • An odontoma is a slow growing and nonaggressive odontogenic tumor composed of enamel, dentin, cementum, and pulp tissue. The etiology of odontomas is unknown, although local trauma, infection, and genetic factors have been suggested. Odontomas are classified as compound odontoma or complex. A 20-year retrospective study was performed on 36 odontomas from the files of the Department of Oral Pathology at Chosun University School of Dentistry. Fifty-six percent of the patients were compound odontoma and 44% were complex odontoma. 56 percent of the patients were female and 44% were male. The odontoma is most often diagnosed in the second decade of life, during routine radiographic examination. The usual presenting symptoms are an impacted or and unerupted tooth, a retained primary tooth. Other less frequent signs and symptoms are pain, swelling, suppuration, foul odor, tooth mobility. In our patients were treated by enucleation of the tumor, and related teeth were treated by surgical extraction or orthodontically assisted eruption.

  • PDF

A STUDY ON THE BONDING OF COMPOMER TO DECIDUOUS DENTIN (컴포머와 유치 상아질의 결합에 관한 연구)

  • Kim, Jee-Tae;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • The purpose of this study was to evaluate the bonding of compomer to deciduous dentin which is known to have been developed to improve the weak properties of glass ionomer cement and composite resin. 120 sound primary molars were used for the shear bond strength test and another 24 for the scanning electron microscopic evaluation. Each material was ailed into polyethylene mold attached to exposed dentinal surface($3{\times}4mm$ in diameter) of sample blocks. Shearbond strength was measured using Universal testing machine and data were analyzed statistically with Oneway-ANOVA and Scheffe test. Scanning electron microscopic observation was performed in order to evaluate the pattern of distribution and penetration of resin tags and hybrid layer. Compomer groups(II-V) showed significantly higher bond strength values than glass ionomer group(I)(p<.05). Etching-compomer groups(III, V) showed the significantly higher bond strength than non-etching compomer groups(II, IV)(p<.05), but slightly lower values than composite resin group(VI) with no statistically significant difference(p>.05). No significantly different bond strength was found between compomer groups of different bonding system(p>.05). Scanning electron micrographs showed more irregular distribution of short and thin resin tags in non-etching compomer groups(II, IV) whereas the more regular and intimate distribution of long and thick tags in etching compomer groups(III, V) and composite resin group(VI). The evaluation of hybrid layer also showed more regular formation of thicker layer in etching compomer groups(III, V). Based on the results of present study, the use of compomer as an esthetic restorative material for primary molars might be justified.

  • PDF

MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITIONS AND CURING LIGHTS IN CLASS I CAVITY OF PRIMARY MOLAR (유구치 I급 와동에서 와동벽 위치와 중합광원에 따른 Microtensile Bond Strength 비교 연구)

  • Lee, Hyeon-Heon;Jang, Chul-Ho;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.62-72
    • /
    • 2007
  • The purpose of present study was to determine whether different kinds of curing lights can alter microtensile bond strength(MTBS) of class I cavity pulpal and axial wall specimens in primary molar. Thirty clean mandibular 2nd primary molar's occlusal enamel were removed and class I cavity, size of $2{\times}4{\times}2mm$ was prepared. Dentin bonding agent was applied according to manufacturer's manual. Each group was cured with Halogen Curing Unit, Plasma Curing Unit and LED Curing Unit. Composite resin was bulk filled and photo cured with same curing unit. MTBS specimens which size is $0.7{\times}0.7{\times}4mm$ were prepared with low speed saw. Specimens were coded by their curing lights and wall positions (Halogen - Axial wall group, Halogen - Pulpal wall group, Plasma - Axial wall group, Plasma - Pulpal wall group, LED - Axial wall group, LED - Pulpal walt group). MTBS were tested at 1 mm/min cross Head speed by Universal Testing Machine. Fractured surface and bonding surface was observed with SEM. T-test between axial and pulpal specimens in each curing lights, one-way ANOVA among different curing light specimens in each wall positions were done. Weibull distribution analysis was done. The results were as follows : Mean MTBS of pulpal wall specimens were significantly greater than that of axial wall specimens at each curing units(p<.05). There was no significant difference in the MTBS among three curing units at axial wall and pulpal wall. In Weibull distribution, pulpal wall specimens were more homogeneous than axial wall specimens.

  • PDF

MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITION IN CLASS I CAVITY OF PRIMARY MOLAR (유구치 1급 와동에서 와동벽 위치에 따른 microtensile bond strength 비교 연구)

  • Lee, Hyeon-Heon;Jung, Tae-Ryun;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.693-698
    • /
    • 2006
  • In Class I cavity, the highest C-factor could be obtained and it means the highest polymerization shrinkage stress. In this study, high C-factor model was designed. The pulpose of present study was to determine differences of Microtensile bond strength (MTBS) of class I cavity pulpal and axial wall specimens in primary molar. Twenty clean mandibular 2nd primary molars were randomly divided into two groups Different composite Resins (Filtek Z250, 3M ESPE & Filtek Supreme, 3M ESPE) were bulk filled and photo cured. Axial wall specimens and pulpal specimens were prepared at the same teeth, All specimens were divided into 4 groups and MTBS were evaluated. Group ZP : Filtek Z250-Pulpal wall Group ZA : Filtek Z250-Axial wall Group SP : Filtek Supreme - Pulpal wall Group SA : Filtek Supreme - Axial wall The results were as follows: 1. Mean MTBS of ZP & ZA and SP & SA were significantly different(p<.001). 2. There was no significant difference between MTBS of ZP & SP and ZA & SA.

  • PDF

EFFECT OF SELF-ETCHING PRIMER APPLICATION ON THE CHARACTERISTICS & STRENGTH OF DENTIN BONDING IN PRIMARY TOOTH (자가부식 프라이머의 처리가 유치의 상아질과 레진 간의 결합 형태와 강도에 미치는 효과)

  • Lee, Jun-Haeng;Kim, Yong-Kee;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.595-607
    • /
    • 1999
  • The purpose of this in vitro study was to evaluate the efficacy of self-etching primer which was developed to simplify the bonding procedures by measuring the shear bond strength and observing the interfacial morphology. 90 flat dentinal surfaces were prepared by grinding the buccal and lingual areas of caries-free human deciduous molars. After bonding of composite resin to sample surfaces according to the manufacturer's direction and thermocycling, shear bond strengths were measured using Universal testing machine(Instron). Another groups of specimens were treated by hydrochloric acid to secure the resin only and those tags were evaluated under SEM for their length and forms and the morphology of the bonding sites were also observed. The result as follows. 1. Group III showed higher shear bond strength than group I and II but no statistically significant difference was founded between group I and II(p>.05). 2. Adhesive failure was predominant in group II whereas dentin detachment was the main failure pattern in group I and III. 3. Relating long resin tags of $100-200{\mu}m$ were observed in samples of all groups under SEM. In group I, homogeneously long resin tags were arranged rather tight whereas rather loosely arranged resin tags of various length were found in group II. Lateral branching of resin tags was the characteristic finding observed in group III.

  • PDF

A STUDY ON THE FORMATION OF SHEAR BONDING STRENGTH AND HYBRID LAYER ACCORDING TO THE APPLICATION TIME AND FREQUENCY OF AN ALL-IN-ONE SYSTEM IN PRIMARY TEETH. (유치에서 All-In-One system의 적용 시간과 적용 횟수에 따른 전단 결합 강도 및 혼성층 형성에 관한 연구)

  • Hong, Sang-Jin;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.263-271
    • /
    • 2003
  • The purpose of the present study was to evaluate the patterns of hybrid layer according to the application time and the frequency and its effects on the shear bonding strength of All-In-One system in primary teeth. A single bonding agent(Scotchbond Multi-Purpose Plus, 3M) and an All-In-One system(Prompt L-pop, 3M ESPE) were applied on the dentin varying the application time and the frequency in primary teeth. Shear bond strength was measured and the patterns of hybrid layers were observed by SEM. The following results were obtained ; 1. The shear bonding strength of single bonding agent was significantly higher than that of All-In-One system(P<0.05). 2. The shear bonding strength of All-In-One system applied twice or 3 times were higher than that of applied once (P<0.05). And thickness of the hybrid layer was increased when applied twice or 3 times compared to once. 3. The shear bonding strength of All-In-One system when applied for 15 second and 30 second were higher than that of 7 second (P<0.05). And the hybrid layer thickness of 15 second and 30 second's application time were higher than that of 7 second. 4. Thickness of hybrid layer applied with single bonding agent was $2-4{\mu}m$ and that of All-In-One system was $1-2{\mu}m$.

  • PDF

SHEAR BOND STRENGTH OF SELF-ETCHING PRIMER SYSTEMS TO CONTAMINATED DENTIN IN PRIMARY TEETH (오염된 유치 상아질에 대한 자가 부식 프라이머의 결합강도에 관한 연구)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eup
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.107-114
    • /
    • 2002
  • The purpose of this study was to determine and compare the shear bond strength of two self-etching primer systems to primary teeth contaminated with saliva and blood. Clearfil SE Bond and AQ Bond were evaluated. One hundred specimens were made by seventy-five deciduous teeth(fifty anterior and twenty-five posterior teeth) and divided randomly into ten groups. Small flat dentinal surfaces were prepared by grinding the buccal, lingual and labial areas. Specific surface treatments were applied to each group: (1) a self-etching primer application(control group), (2) saliva contamination followed by primer(Group I), (3) primer curing followed by saliva contamination (Group II), (4) blood contamination followed by primer(Group III), (5) primer curing followed by blood contamination(Group IV). After bonding of composite resin(Z100, 3M, USA) to contaminated sample surfaces and thermocycling(1,000 cycles), shear bond strengths were measured using Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results were as follows; 1. Group I showed lower shear bond strength than control group but no statistically significant difference was found(P>0.05). 2. Group II and blood contamination group(Group III & IV) showed significantly lower shear bond strength than control group(P<0.01). 3. The shear bond strength of Clearfil SE Bond was significantly higher than that of AQ Bond(P<0.05).

  • PDF